Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample acquisitions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Uniformity and volume-representativity of consecutive submillimetre wafers of shale for SANS and USANS investigations

(Ultra) Small Angle Neutron Scattering (SANS/USANS) is a non-destructive technique suitable for characterization of porous structures from nano- to micro-pore size (1 nm to 20 μm), which has been widely used to characterize accessible and inaccessible porosity in tight unconventional hydrocarbon reservoirs (e.g., shales). Here, in this study, SANS and USANS are used to examine the degree of nano- to micropore uniformity of the rock body on sub-millimetre to centimetre scale. This study presents a test of the hypothesis of volume representativity of pore structure information measured by SANS and USANS for shale wafers (0.22–1 mm) cut from six North American unconventional shale cores of different maturities (New Albany Shale and Marcellus Shale). Experimental reproducibility of USANS is further investigated for two wafers measured using various acquisition times. All samples show that fluctuations of the relative intensity generally decrease from the USANS Q-range (pore size from around 200 nm to 20 μm) to most of the SANS Q-range (pore size from around 5 nm to 700 nm), and peaks in the SANS large-Q region (for pores smaller than about 5 nm). There is a positive correlation between the spatial fluctuation of the relative SANS intensity and the scattering power of shales. In addition, the scattering intensity and its fluctuations is larger for the less mature shale cores. Shale is known to be highly heterogenous and the hypothesis of uniformity does not apply at sub-millimetre scale even for samples that appear homogeneous at visual inspection. This study presents an approach to minimise the variation through sample selection, data interpretation methodology and instrumental reproducibility tests. The best values of the microstructural spatial uniformity for the apparently homogeneous sections of a core (i.e., the SANS and USANS intensity variation) is less than ±10%.

01 COAL, LIGNITE, AND PEAT↗

Evaluating Limits of Machine Learning-Assisted Raman Spectroscopy in Classification of Biological Samples

Machine learning (ML)-assisted Raman spectroscopy has become a powerful analytical tool for the classification and identification of analytes; however, technical challenges impacting its detection accuracy have not been thoroughly investigated. This study explores experimental factors affecting classification performance. Among the evaluated ML models, ML algorithms show minimal impact on classification accuracy. Instead, experimental factors, including spectral similarity between tested samples and data quality, dominate detection performance. Increases in spectral noise and spectral similarity significantly reduce classification accuracy. In well-controlled samples with low experimental noise, ML-assisted Raman spectroscopy can discriminate lipid mixtures with a composition difference of 1.85 mol %. To assess the effect of biological heterogeneity, we analyzed single-cell Raman spectra from Saccharomyces cerevisiae strains carrying single, double, or triple gene mutations. Intrinsic cell-to-cell variability introduced substantial spectral differences, severely reducing the accuracy of multiclass classification of these genetically similar strains at the single-cell level. Averaging Raman spectra across multiple cells improved classification accuracy by reducing this spectral variability. We also assess the effectiveness of transfer learning across different Raman spectrometers, specifically by applying an ML model trained on one instrument to another Raman spectrometer. Transfer learning can be improved with proper instrument calibration, highlighting the importance of instrument standardization. Overall, our results demonstrate that data quality and spectral similarity are the primary bottlenecks in ML-assisted Raman spectroscopy. Careful attention to sample preparation, data acquisition, measurement conditions, and instrument calibration is critical to achieving robust and reliable classification performance.

Fungi↗

Enhancing hyperspectral EELS analysis of complex plasmonic nanostructures with pan-sharpening

Nanoscale hyperspectral techniques—such as electron energy loss spectroscopy (EELS)—are critical to understand the optical response in plasmonic nanostructures, but as systems become increasingly complex, the required sampling density and acquisition times become prohibitive for instrumental and specimen stability. As a result, there has been a recent push for new experimental methodologies that can provide comprehensive information about a complex system, while significantly reducing the duration of the experiment. In this work, we present a pan-sharpening approach to hyperspectral EELS analysis, where we acquire two datasets from the same region (one with high spatial resolution and one with high spectral fidelity) and combine them to achieve a single dataset with the beneficial properties of both. This work outlines a straightforward, reproducible pathway to reduced experiment times and higher signal-to-noise ratios, while retaining the relevant physical parameters of the plasmonic response, and is generally applicable to a wide range of spectroscopy modalities.

36 MATERIALS SCIENCE↗

Data supporting the manuscript "Nanometer Scale Imaging to Develop Quantitative Descriptors of Bipolar Membrane Junction Structure"

This dataset contains atomic force microscopy images associated with the manuscript "Nanometer Scale Imaging to Develop Quantitative Descriptors of Bipolar Membrane Junction Structure" by Maria Kelly, Emily R. Dunn, Ellis A. Spickermann, Josephine N. Gruber, César A. Lasalde-Ramírez, P. N. Romero Zavala, Éowyn Lucas, Ankur Gupta, Harry A. Atwater, and Wilson A. Smith. The dataset contains both raw images as well as segmented images produced by the image processing workflow described in the manuscript. A readme file and meta data file are included to provide additional details regarding the sample identity, image acquisition parameters, and file naming scheme.

36 MATERIALS SCIENCE↗

Real-time sparse-sampled Ptychographic imaging through deep neural networks

Ptychography has rapidly grown in the fields of X-ray and electron imaging for its unprecedented ability to achieve nano or atomic scale resolution while simultaneously retrieving chemical or magnetic information from a sample. A ptychographic reconstruction is achieved by means of solving a complex inverse problem that imposes constraints both on the acquisition and on the analysis of the data, which typically precludes real-time imaging due to computational cost involved in solving this inverse problem. In this work we propose PtychoNN, a novel approach to solve the ptychography reconstruction problem based on deep convolutional neural networks. We demonstrate how the proposed method can be used to predict real-space structure and phase at each scan point solely from the corresponding far-field diffraction data. The presented results demonstrate how PtychoNN can effectively be used on experimental data, being able to generate high quality reconstructions of a sample up to hundreds of times faster than state-of-the-art ptychography reconstruction solutions once trained. By surpassing the typical constraints of iterative model-based methods, we can significantly relax the data acquisition sampling conditions and produce equally satisfactory reconstructions. Besides drastically accelerating acquisition and analysis, this capability can enable new imaging scenarios that were not possible before, in cases of dose sensitive, dynamic and extremely voluminous samples.

Cherukara, Mathew J↗

Design and Integration of a Compact Mobile Outdoor Soil Sampling Agricultural Robot

The lack of feedback on soil management for crop systems necessitates the collection of soil samples to derive insights into prevailing soil conditions. Achieving an accurate model of these plantations requires a substantial number of soil samples, which is a labor-intensive process that can suffer from inconsistencies in both the methodology of collection and the locations from which samples are gathered. In addition, the close spacing of crop rows constrains the maneuverability of mobile agricultural equipment during sample collection. This article proposes the use of agricultural robotics to facilitate the acquisition of composite soil samples with minimal human intervention, allowing for precise data collection for a Populus plant system. More specifically, this article presents a case study on the design and construction of a compact agricultural robot for soil sample collection. The performance of the robot, including its soil collection efficacy, maneuverability, and positional accuracy, is evaluated.

42 ENGINEERING↗

Sub-10 second fly-scan nano-tomography using machine learning

Abstract X-ray computed tomography is a versatile technique for 3D structure characterization. However, conventional reconstruction algorithms require that the sample not change throughout the scan, and the timescale of sample dynamics must be longer than the data acquisition time to fulfill the stable sample requirement. Meanwhile, concerns about X-ray-induced parasite reaction and sample damage have driven research efforts to reduce beam dosage. Here, we report a machine-learning-based image processing method that can significantly reduce data acquisition time and X-ray dose, outperforming conventional approaches like Filtered-Back Projection, maximum-likelihood, and model-based maximum-a-posteriori probability. Applying machine learning, we achieve ultrafast nano-tomography with sub-10 second data acquisition time and sub-50 nm pixel resolution in a transmission X-ray microscope. We apply our algorithm to study dynamic morphology changes in a lithium-ion battery cathode under a heating rate of 50 o C min −1 , revealing crack self-healing during thermal annealing. The proposed method can be applied to various tomography modalities.

36 MATERIALS SCIENCE↗

X-ray fluorescence microscopy methods for biological tissues

Abstract Synchrotron-based X-ray fluorescence microscopy is a flexible tool for identifying the distribution of trace elements in biological specimens across a broad range of sample sizes. The technique is not particularly limited by sample type and can be performed on ancient fossils, fixed or fresh tissue specimens, and in some cases even live tissue and live cells can be studied. The technique can also be expanded to provide chemical specificity to elemental maps, either at individual points of interest in a map or across a large field of view. While virtually any sample type can be characterized with X-ray fluorescence microscopy, common biological sample preparation methods (often borrowed from other fields, such as histology) can lead to unforeseen pitfalls, resulting in altered element distributions and concentrations. A general overview of sample preparation and data-acquisition methods for X-ray fluorescence microscopy is presented, along with outlining the general approach for applying this technique to a new field of investigation for prospective new users. Considerations for improving data acquisition and quality are reviewed as well as the effects of sample preparation, with a particular focus on soft tissues. The effects of common sample pretreatment steps as well as the underlying factors that govern which, and to what extent, specific elements are likely to be altered are reviewed along with common artifacts observed in X-ray fluorescence microscopy data.

Pushie, M. Jake (ORCID:0000000174945427)↗

Fast image acquisition system and method using pulsed light illumination and sample scanning to capture optical micrographs with sub-micron features

An optical inspection system for detecting sub-micron features on a sample component. The system may have a controller, a camera responsive to the controller for capturing images, an objective lens able to capture submicron scale features on the sample component, and a pulsed light source. The pulsed light source may be used to generate light pulses. The camera may be controlled to acquire images, using the objective lens, only while the pulsed light source is providing light pulses illuminating a portion of the sample component. Relative movement between the sample component and the objective lens is provided to enable at least one of a desired subportion or an entirety of the sample component to be scanned with the camera.

Yoo, Jae Hyuck↗

MARLOWE: An Untargeted Proteomics, Statistical Approach to Taxonomic Classification for Forensics

General proteomics research for fundamental science typically addresses laboratory- or patient-derived samples of known origin and composition. However, in a few research areas, such as environmental proteomics, clinical identification of infectious organisms, archeology, art/cultural history, and forensics, attributing the origin of a protein-containing sample to the organisms that produced it is a central focus. A small number of groups have approached this problem and developed software tools for taxonomic characterization and/or identification using bottom-up proteomics. Most such tools identify peptides via database search, and many rely on organism-specific peptides as markers. Our group recently introduced MARLOWE, a software tool for taxonomic characterization of unknown samples based on de novo peptide identification and signal-erosion-resistant strong peptides, which are shared peptides distributed in a taxonomy-dependent manner. In the current work, we further characterize the utility of MARLOWE using publicly available proteomics data from forensically-relevant samples. MARLOWE characterizes samples based on their protein profile, and returns ranked organism lists of potential contributors and taxonomic scores based on shared strong peptides between organisms. Overall, the correct characterization rate ranges between 44 and 100%, depending on the sample type and data acquisition parameters (with lower numbers associated with lower-quality data sets). MARLOWE demonstrates successful characterization of true contributors and close relatives, and provides sufficient specificity to distinguish certain microbial species. MARLOWE demonstrates its ability to provide insight into potential taxonomic sources for a wide range of sample types without prior assumptions about sample contents. As a result, this approach can find utility in forensic science and also broadly in bioanalytical applications that utilize proteomics approaches for taxonomic characterization.

Bacteria↗

Chemistry imaging and distribution analysis of rare earth elements in coal using LIBS and LA-ICP-MS instruments

Currently, demand for rare earth elements (REEs) increased significantly. Coal is actively evaluated as potential economic sources for extraction of REEs. Here, in this work, laser-induced breakdown spectroscopy (LIBS) was evaluated for rapid estimation of REEs content and their distribution in the natural coal samples. The results were compared with similar laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS) measurements. Thirteen coal samples (nine standard samples and five natural samples) were used in this study. Powder samples were pressed into pellets while coal chunks were directly ablated for data recording. Pellets of the powder standard samples were used to optimize the data acquisition system and then data recorded with this optimized system was used to identify the proper data acquisition and analysis models. After establishing the proper data acquisition system and analysis model using the standard samples, natural coal samples in powder form and their chunks were utilized to record LIBS and LA-ICP-MS spectra. Multivariate calibration models were developed using four of the natural samples, which were evaluated by predicting the REE content in the fifth sample. Principal component analysis was performed on the LIBS data obtained from the natural samples and it classified all the samples with high accuracy. Two-dimensional (2D) elemental mapping on coal chunk samples was also performed using both LIBS and LA-ICP-MS to study the distribution of REEs in the samples. The resulting elemental images and their correlations can be used to infer mineral distributions.

01 COAL, LIGNITE, AND PEAT↗

Design of a robot-automated flat plate/reflection geometry x-ray diffraction setup for accelerated materials discovery and structural screening

Here, we report the design, construction, and automation of a flat plate sample loading, alignment, and data acquisition system for X-ray diffraction measurements in reflection geometry implemented at the Stanford Synchrotron Radiation Lightsource. The system is built onto a single platform, enabling facile transferability, and is compartmentalized into sample storage, sample transfer, and sample position/alignment segments. The core feature of this system is a six-axis robotic arm that offers a large range of highly reproducible and programable movements. The degrees of freedom of the robot arm enable adaptability in which movements can be modified to fit various beamline environments and sample configurations. Samples are housed on 3D printed sample mounts, which are arranged onto a 6 × 2 array of sample cassettes capable of holding 7 samples. Using sample mounts designed for solid oxide electrolysis button cells (SOECs), the maximum tray capacity is 84 samples, which can be aligned and run in ~ 24 hours with long exposure scans. The sample array is additionally capable of accommodating a range of sample sizes and geometries due to the rapid 3D printed fabrication. The components of the setup will be described in detail and performance will be demonstrated with a set of representative SOEC and XRD standard samples. Opportunities for future developments and integration with the automated setup are summarized.

08 HYDROGEN↗

Tunable diode laser absorption spectroscopy with corrected laser ramping nonlinearities

A tunable diode laser absorption spectroscopy device includes a tunable diode laser. A laser driver is configured to drive the diode laser and ramp it within a particular frequency range. An analyte gas container, a reference gas container, and a fringe generating device are configured to receive the laser therethrough. An optical detector is configured to detect the laser after it has passed through the analyte gas container and/or the reference gas container, and the in-line fringe generating device. An acquisition card is configured to sample an output of the optical detector. A spectral analyzer is configured to receive output data from the acquisition card, determine a spectrum of the output data, decouple the fringe spectrum from the measured spectrum, calibrate the spectrum based on an expected ideal spectrum of both the fringe and reference gas, and determine a composition of the analyte based on the calibrated spectrum.

42 ENGINEERING↗

Nano-laminography with a transmission X-ray microscope

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MemXCT: Design, Optimization, Scaling, and Reproducibility of X-Ray Tomography Imaging

Here, this work extends our previous research entitled "MemXCT: Memory-centric X-ray CT Reconstruction with Massive Parallelization" that was originally published at SC19 conference (Hidayetoglu et al., 2019) with reproducibility of the computational imaging performance. X-ray computed tomography (XCT) is regularly used at synchrotron light sources to study the internal morphology of materials at high resolution. However, experimental constraints, such as radiation sensitivity, can result in noisy or undersampled measurements. Further, depending on the resolution, sample size and data acquisition rates, the resulting noisy dataset can be in the order of terabytes. Advanced iterative reconstruction techniques can produce high-quality images from noisy measurements, but their computational requirements have made their use an exception rather than the rule. We propose a novel memory-centric approach that avoids redundant computations at the expense of additional memory complexity. We develop a memory-centric iterative reconstruction system, MemXCT, that uses an optimized SpMV implementation with two-level pseudo-Hilbert ordering and multi-stage input buffering. We evaluate MemXCT on various supercomputer architectures involving KNL and GPU. MemXCT can reconstruct a large (11Kx11K) mouse brain tomogram in 10 seconds using 4096 KNL nodes (256K cores). The results presented in our original article at the SC19 were based on large-scale supercomputing resources. The MemXCT application was selected for the Student Cluster Competition (SCC) Reproducibility Challenge and evaluated on a variety of cloud computing resources by universities around the world in the SC20 conference. We summarize the results of the top-ranked SCC Reproducibility Challenge teams and identify the most pertinent measures for ensuring the reproducibility of our experiments in this article.

47 OTHER INSTRUMENTATION↗

Illuminating the Material World: Autonomous Microscopy to Understand Order, Disorder, and Everything In Between

Artificial intelligence (AI) holds immense promise for revolutionizing microscopy, yet its widespread adoption has been hindered by challenges ranging from user inexperience to limited model transferability and difficulties in operationalizing machine learning. This presentation showcases our approach to developing practical autonomy for materials discovery, aiming to accelerate the integration of AI into everyday microscopy workflows. As shown in Fig. 1, I will focus on three key areas: understanding order-disorder transitions, quantifying point defects, and achieving truly device-scale microscopy. First, I will demonstrate the power of multi-modal knowledge graphs for integrating diverse microscopy data. By combining imaging, spectroscopy, and diffraction data, these graphs provide a holistic view of material behavior, capturing the intricate relationships between different modalities [1,2]. I will present a case study on how these models illuminate the structural and chemical changes associated with irradiation in oxide thin films, revealing critical insights for designing materials for extreme environments like spaceflight and nuclear energy. Specifically, I will show how multi-modal analysis clarifies the evolution of order-disorder transitions under irradiation, a key factor influencing material performance in these applications. Next, I will address the challenge of quantifying point defects in 2D materials. We demonstrate the application of computer vision and transfer learning to accurately identify and classify various defect types, such as vacancies and substitutional atoms, and to quantify their concentrations. This information is crucial for understanding and tailoring the properties of 2D materials for applications in electronics, optoelectronics, and catalysis. For example, I will show how our models can characterize the topological distribution of point defects in MXene transition metal carbides, providing valuable insights for optimizing their performance in energy storage and separation science. Finally, I will discuss our progress toward autonomous device-scale microscopy [3,4]. We are fundamentally redesigning electron microscopes around the principles of machine reasoning, enabling automation beyond basic tasks like sample navigation and data acquisition to include sophisticated experimental design. This approach paves the way for truly reproducible and massively scaled analysis campaigns. I will emphasize the importance of autonomous microscopy platforms for high-throughput materials discovery and characterization, facilitating the rapid screening of materials for a broad range of applications and accelerating the development of next-generation technologies.

36 MATERIALS SCIENCE↗

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Neutrons have historically been used for a broad range of biological applications employing techniques such as small-angle neutron scattering, neutron spin echo, diffraction, and inelastic scattering. Unlike neutron scattering techniques that obtain information in reciprocal space, attenuation-based neutron imaging measures a signal in real space that is resolved on the order of tens of micrometers. The principle of neutron imaging follows the Beer-Lambert law and is based on the measurement of the bulk neutron attenuation through a sample. Greater attenuation is exhibited by some light elements (most notably, hydrogen), which are major components of biological samples. Contrast agents such as deuterium, gadolinium, or lithium compounds can be used to enhance contrast in a similar fashion as it is done in medical imaging, including techniques such as optical imaging, magnetic resonance imaging, X-ray, and positron emission tomography. For biological systems, neutron radiography and computed tomography have increasingly been used to investigate the complexity of the underground plant root network, its interaction with soils, and the dynamics of water flux in situ. Moreover, efforts to understand contrast details in animal samples, such as soft tissues and bones, have been explored. This manuscript focuses on the advances in neutron bioimaging such as sample preparation, instrumentation, data acquisition strategy, and data analysis using the High Flux Isotope Reactor CG-1D neutron imaging beamline. The aforementioned capabilities will be illustrated using a selection of examples in plant physiology (herbaceous plant/root/soil system) and biomedical applications (rat femur and mouse lung).

Bilheux, Hassina↗

Autonomous adaptive data acquisition for scanning hyperspectral imaging

Non-invasive and label-free spectral microscopy (spectromicroscopy) techniques can provide quantitative biochemical information complementary to genomic sequencing, transcriptomic profiling, and proteomic analyses. However, spectromicroscopy techniques generate high-dimensional data; acquisition of a single spectral image can range from tens of minutes to hours, depending on the desired spatial resolution and the image size. This substantially limits the timescales of observable transient biological processes. To address this challenge and move spectromicroscopy towards efficient real-time spatiochemical imaging, we developed a grid-less autonomous adaptive sampling method. Our method substantially decreases image acquisition time while increasing sampling density in regions of steeper physico-chemical gradients. When implemented with scanning Fourier Transform infrared spectromicroscopy experiments, this grid-less adaptive sampling approach outperformed standard uniform grid sampling in a two-component chemical model system and in a complex biological sample, Caenorhabditis elegans. We quantitatively and qualitatively assess the efficiency of data acquisition using performance metrics and multivariate infrared spectral analysis, respectively.

47 OTHER INSTRUMENTATION↗