Search NASA⌕ Search

SEARCH · Search NASA

Results for “transfer standard”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Vacuum ultraviolet radiometry. III - The argon mini-arc as a new secondary standard of spectral radiance

A miniature argon arc has been designed and tested as a new transfer standard of spectral radiance for the wavelength range from 114 nm to 330 nm. Calibration has been performed using two primary standard sources: the hydrogen arc from 130 nm to 330 nm and the blackbody line radiator from 114 nm to 130 nm. The mini-arc provides an intense, stable, and reproducible UV continuum with dc power requirements of less than 1.5 kW. The arc characteristics have been investigated, and the sensitivity of the radiant power output to various operating parameters has been measured. The rms uncertainty in the spectral radiance is estimated to be 5.3% above 140 nm and 10.1% between 114 nm and 140 nm, due primarily to uncertainties in the primary standard sources.

Bridges, J. M.↗

Development of a New Departure Aversion Standard for Light Aircraft

The Federal Aviation Administration (FAA) and European Aviation Safety Agency (EASA) have recently established new light aircraft certification rules that introduce significant changes to the current regulations. The changes include moving from prescriptive design requirements to performance-based standards, transferring many of the acceptable means of compliance out of the rules and into consensus standards. In addition, the FAA/EASA rules change the performance requirements associated with some of the more salient safety issues regarding light aircraft. One significant change is the elimination of spin recovery demonstration. The new rules now call for enhanced stall warning and aircraft handling characteristics that demonstrate resistance to inadvertent departure from controlled flight. The means of compliance with these changes in a safe, cost-effective manner is a challenging problem. This paper discusses existing approaches to reducing the likelihood of departure from controlled flight and introduces a new approach, dubbed Departure Aversion, which allows applicants to tailor the amount of departure resistance, stall warning, and enhanced safety equipment to meet the new proposed rules. The Departure Aversion approach gives applicants the freedom to select the most cost-effective portfolio for their design, while meeting the safety intent of the new rules, by ensuring that any combination of the selected approaches will be at a higher equivalent level of safety than today's status quo.

Borer, Nicholas K.↗

Progress on GPS standardization

It has been clear for some time that a desirable and necessary step for improvement of the accuracy of GPS time comparisons is to establish GPS standards which may be adopted by receiver designers and users. For this reason, a formal body, the CCDS Group on GPS Time Transfer Standards (CGGTTS), was created in 1991. It operates under the auspices of the permanent CCDS Working Group on TAI, with the objective of recommending procedures and models for operational time transfer by the GPS common-view method. It works in close cooperation with the Subcommittee on Time of the Civil GPS Service Interface Committee. The members of the CGGTTS have met in December 1991 and in June 1992. Following these two formal meetings, a number of decisions were taken for unifying the treatment of GPS short-term data and for standardizing the format of GPS data files. A formal CGGTTS Recommendation is now being written concerning these points. This paper relates on the work carried out by the CGGTTS.

Thomas, C.↗

The need for GPS standardization

A desirable and necessary step for improvement of the accuracy of Global Positioning System (GPS) time comparisons is the establishment of common GPS standards. For this reason, the CCDS proposed the creation of a special group of experts with the objective of recommending procedures and models for operational time transfer by GPS common-view method. Since the announcement of the implementation of Selective Availability at the end of last spring, action has become much more urgent and this CCDS Group on GPS Time Transfer Standards has now been set up. It operates under the auspices of the permanent CCDS Working Group on TAI and works in close cooperation with the Sub-Committee on Time of the Civil GPS Service Interface Committee (CGSIC). Taking as an example the implementation of SA during the first week of July 1991, this paper illustrates the need to develop urgently at least two standardized procedures in GPS receiver software: monitoring GPS tracks with a common time scale and retaining broadcast ephemeris parameters throughout the duration of a track. Other matters requiring action are the adoption of common models for atmospheric delay, a common approach to hardware design and agreement about short-term data processing. Several examples of such deficiencies in standardization are presented.

W. Lewandowski↗

Scalable standard optical sources in the VUV: Emissions from electron impact on metals

The use of electron impact on metals in the development of a compact optical standard lamp in the vacuum ultraviolet is described. Two different mechanisms are exploited, transition radiation and bremsstrahlung. Transition radiation will be used as a primary standard from 1200A to 3000A using 10 keV electron impact on tungsten. Bremsstrahlung will be used in the soft X-ray region below 1200A to less than 5A as an optical transfer standard from 4 keV electron impact on tantalum or tungsten.

Hughes, R.↗

Verification of Nimbus 4 BUV total ozone data and the requirements for operational satellite monitoring

Data obtained from the backscattering ultraviolet instrument on Nimbus 4 are compared with standardized observations such as ground based Dobson and M83 measurements. Results of the comparison are discussed and their impact on planning for a satellite ozone monitoring program is assessed. It is suggested that the satellite data be used as a transfer standard whereby, if a discrepancy in an individual ground station is detected, that station instrument would be noted for recalibration.

Miller, A. J.↗

A report from the AVS Standards Committee - Comparison of ion gauge calibrations by several standards laboratories

Calibrations by four U.S. laboratories of four hot-cathode ion gauges, in the range 0.07-13 mPa, showed systematic differences among laboratories that were much larger than the expected error of any one calibration. They also suggested that any of the four gauges tested, if properly packaged and shipped, was able to serve as a transfer standard with probable error of 2%. A second comparison was made of the calibrations by two U.S. laboratories of some other gauges that had also been calibrated by the National Physical Laboratory, England. Results did not permit conclusive determination of whether differences were due to the laboratories or to changes in the gauges.

Warshawsky, I.↗

Calibration standards and field instruments for the precision measurement of insolation

The design of a fieldworthy survey instrument based on a developed radiation calibration standard is discussed. The radiometer system, a fieldworthy modification of Pacrad, is an all-weather solar radiometer, and a field test is described which demonstrates the instrument's stability in severe environments over an extended period of time. It is suggested that the instrument may be considered a transfer standard as well as a radiometer. It is hoped that future modifications might reduce the 15-deg view angle and improve the tracking system to eliminate weekly manual declination adjustments.

Reid, M. S.↗

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗

Comparison of Detector Based and Source Based Absolute Radiance Standards

A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.

radiometry↗

Compact far ultraviolet emission source with rich spectral emission 1150-3100 A

The article describes a compact hollow Pt cathode emission source for the far UV, developed for use as a high-resolution wavelength standard in laboratory work or on spacecraft (specifically, the NASA International UV Explorer - IUE). The source is small, rugged, lightweight, spectrally rich, bright in the 1150-3200 A region, features long service life, low operating voltage, and lower power drain, and stably emits a large number of very sharp lines with a spectrum lending itself to projection onto the focal plane of a spectrograph. The source has successfully passed exacting environmental tests, and serves as a transfer standard for absolute sensitivity calibration of spectrometric instruments.

Mount, G. H.↗

Some Long-Standing Issues Arising From Comparisons Between TOMS and The Ground-Based Ozone Network

Data from the series of Total Ozone Mapping Spectrometers (TOMS) have been compared to column ozone measurements taken by ground-based systems (Dobsons, Brewers and Filtermeters). On average, the comparisons show good agreement, with approximately 80% of the ground stations having less than a 2.5% standard deviation when compared to TOMS on a monthly mean basis. There are, however, differences that imply possible errors either in the TOMS ozone retrieval algorithm or in the basic assumptions used by the ground-based instruments. Some of the issues arising from these differences are: What are the relative calibrations of TOMS instruments? Why do the calibrations of the ground-based stations vary as much as they do with respect to TOMS as a transfer standard? Why are the TOMS data so much larger (approximately 6%) than the ground-based data in Antarctica and other ice-covered locations? Why is there seasonality in the difference between TOMS and ground-based stations in the Southern Hemisphere? Why are the differences a function of total ozone? Where and why are the differences a function of reflectivity? Why do some terrain and land-sea boundary features appear in the TOMS ozone data? The above issues will be highlighted by using data from TOMS and the ground stations. Plots of the individual station differences will be available.

Labow, Gordon J.↗

Radiometry using synchrotron radiation

It is possible to use synchrotron radiation from electron synchrotrons and electron storage rings as an absolute source, especially in the VUV and soft X-ray regions where other standards are difficult to find. At the NBS, an electron storage ring (SURF-II) has been used to calibrate spectrometers and photometers utilized in solar and aeronomy research and in fusion plasma diagnostics. The radiation incident on these spectrometers can be calculated to uncertainties of 3%, and a technique to exactly determine the number of electrons orbiting in the ring is currently being developed to reduce this uncertainty. Detector calibrations between 5 and 55 nm are routinely performed at SURF-II and transfer standard detectors with 6-10% uncertainties over the range 5-254 nm are supplied.

Saloman, E. B.↗

An improved rocket ozonesonde (ROCOZ-A). II - Preparation of stratospheric ozone profiles

The ROCOZ-A radiometer measures ozone by long pathlength photometry in the stratosphere and lower mesosphere. After a rocket launch to an apogee of 70 km, the instrument measures the solar ultraviolet irradiance over its four filter wavelengths as it descends on a parachute. The fundamental values from ROCOZ-A are ozone overburdens versus radar altitude from 53 to 20 km. The slope of these values gives ozone number density. At one standard deviation the repeatability of the ozone overburden measurements averages 2.4 percent. For ozone number density the repeatability averages 3.2 percent with a significant increase at altitudes below the ozone number density maximum. The accuracy limits for overburden and number density are estimated at 5-7 percent. With auxiliary measurements of pressure and temperature, ozone results are also produced in terms of ozone mixing ratio, albeit with a slight broadening of the estimated accuracy limits. The vertical response of ROCOZ-A ozone measurements (full width at half maximum) is 4 km. The assembly of ROCOZ-A profiles can be used to compare with measurements from each of the current NASA and NOAA satellite ozone instruments. In addition, the repeatability of ROCOZ-A allows the use of this instrument as a transfer standard between satellite instruments with different fundamental ozone measurements.

Barnes, Robert A.↗

Sea WiFS Technical Report Series: The fourth SeaWIFS Intercalibration Round-Robin Experiment (SIRREX-4), May 1995

This report documents the fourth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-4), which was held at the National Institute of Standards and Technology (NIST) on 3-10 May 1995. The agenda for SIRREX-4 was established by a consensus reached at the conclusion of SIRREX-3: there should be an emphasis on training and work to foster and encourage uniform use of accepted protocols for calibrating radiometric instruments in the laboratory. The goal was to host the activity in a setting where proper techniques could be discussed and demonstrated. It seemed appealing to split the day between morning lectures and afternoon laboratory exercises or practicals. The former gave the user community a chance to present what was important to them and discuss it with acknowledged experts in radiometry, while the latter presented a unique opportunity for training and evaluation in the presence of these same experts. The five laboratory sessions were concerned with (1) determining the responsivity of a spectroradiometer and the spectral radiance of an unknown integrating sphere source, (2) demonstrating spectral field calibration procedures for an integrating sphere using three different instruments, (3) measuring spectral radiance using the plaque method, (4) setting up and aligning lamp calibration transfer standards using the NIST specifications for irradiance measurements, and (5) characterizing radiometric instruments. In addition to documenting some supplemental studies performed outside the laboratory sessions, this report includes an evaluation of the hardware that has been used during the SIRREX activities plus a critical evaluation of SIRREX objectives.

Johnson, B. Carol↗

Tropospheric Ozone Assessment Report: Tropospheric Ozone From 1877 to 2016, Observed Levels, Trends and Uncertainties

From the earliest observations of ozone in the lower atmosphere in the 19th century, both measurement methods and the portion of the globe observed have evolved and changed. These methods have different uncertainties and biases, and the data records differ with respect to coverage (space and time), information content, and representativeness. In this study, various ozone measurement methods and ozone datasets are reviewed and selected for inclusion in the historical record of background ozone levels, based on relationship of the measurement technique to the modern UV absorption standard, absence of interfering pollutants, representativeness of the well-mixed boundary layer and expert judgement of their credibility. There are significant uncertainties with the 19th and early 20th-century measurements related to interference of other gases. Spectroscopic methods applied before 1960 have likely underestimated ozone by as much as 11% at the surface and by about 24% in the free troposphere, due to the use of differing ozone absorption coefficients. There is no unambiguous evidence in the measurement record back to 1896 that typical mid-latitude background surface ozone values were below about 20 nmol mol–1, but there is robust evidence for increases in the temperate and polar regions of the northern hemisphere of 30–70%, with large uncertainty, between the period of historic observations, 1896–1975, and the modern period (1990–2014). Independent historical observations from balloons and aircraft indicate similar changes in the free troposphere. Changes in the southern hemisphere are much less. Regional representativeness of the available observations remains a potential source of large errors, which are difficult to quantify. The great majority of validation and intercomparison studies of free tropospheric ozone measurement methods use ECC ozonesondes as reference. Compared to UV-absorption measurements they show a modest (~1–5% ±5%) high bias in the troposphere, but no evidence of a change with time. Umkehr, lidar, and FTIR methods all show modest low biases relative to ECCs, and so, using ECC sondes as a transfer standard, all appear to agree to within one standard deviation with the modern UV-absorption standard. Other sonde types show an increase of 5–20% in sensitivity to tropospheric ozone from 1970–1995. Biases and standard deviations of satellite retrieval comparisons are often 2–3 times larger than those of other free tropospheric measurements. The lack of information on temporal changes of bias for satellite measurements of tropospheric ozone is an area of concern for long-term trend studies.

UV absorption standard↗

Measuring X-Ray Emission Line Shapes in Neutral Species for XRISM Calibration

Space X-ray spectrometers such as the Resolve instrument on XRISM require precise calibration in order to interpret the spectra of astrophysical objects. Key components of the calibration are the energy scale and the core line spread function, both of which vary with photon energy. A major issue in the calibration of high-resolution spectrometers is locating good calibrators with well-known and stable intrinsic line shapes. Neutral fluorescence is widely used, but inner-shell transitions in neutral atoms often exhibit complex, poorly documented line shapes that vary with excitation conditions. Here, in this study, we present empirical measurements of K-shell transitions in neutral O and F below 1 keV using an engineering model XRISM calorimeter array, an electron bombardment modulated X-ray source, and an electron beam ion trap (EBIT) to provide a precise energy reference. In addition, we report measurements of the Mo Lα complex with the transition-edge microcalorimeter spectrometer (TEMS), which reveal strong satellite structure and sensitivity of the line shape to the incident exciting spectrum. Together, these results demonstrate the need for empirical line-shape models, highlight the nonstationary nature of neutral fluorescence features, and define a path toward developing transfer standards for XRISM and future precision instruments such as Athena/X-IFU.

Astronomy and AstroPhysics↗

HPXML Version Translator

HPXML is a consensus data transfer standard for residential buildings. Over several years, multiple versions of the standard have been released. This tool accepts an HPXML file in an older version and translates it to a newer version.

Merket, Noel↗