Search NASASearch

SEARCH · Search NASA

Results for “Lithium Ion Battery Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

630 records · Page 20

Bioinspired Dry‐Steam Superinsulation Straw Foam

Abstract Cellulosic materials offer sustainable advantages for building energy conservation. However, their development has been hindered by reduced thermal performance, often caused by structural collapse during the transition from solution to solid. Inspired by natural goose down, a bio‐based, lightweight insulation foam derived from agricultural waste straw is presented. Through in situ synthesis, bio‐silica fibers with branched structures capable of supporting hollow silica microspheres are fabricated. After steam‐mediated processing, the resulting foam exhibit low density (95 mg cm − 3 ), high porosity (95.5%), low thermal conductivity (0.03 ± 0.003 W mK −1 ), and a cyclic compressive strength of 90 kPa at 50% strain. Owing to the synergistic microstructure formed by branched bio‐fibers and hollow silica spheres, the bio‐silica foam exhibit outstanding thermal insulation performance relative to other bio‐based foams prepared by ambient drying. A passivated insulation panel is further developed by incorporating this material as the core component, achieving a thermal conductivity of 0.0275 W mk −1 and flexural strength of 6.85 MPa. The panel demonstrated durability with stable thermal performance throughout a 60‐day outdoor test. Moreover, the bio‐silica foam shows a carbon footprint of 7.50 kgCO₂ kg −1 at 70.2 wt.% silica, highlighting its promise as a sustainable insulation solution for green buildings.

Chemistry

How efficiently can AI recognize Wireless Devices?

This poster presents a hardware benchmarking methodology for a 3-layer CNN waveform classifier deployed using ONNX Runtime on an NVIDIA Jetson AGX Orin. The dataset consist of 9 signal types, -30 to +30 dB SNR with 5dB increments. Benchmarking on the Jetson AGX Orin gave an accuracy of 91.9% and GPU throughput of 107,120 predictions/sec (23× faster than CPU). The Jetson GPU reached approximately 27M samples/sec with stable performance but fell below the 40 MHz rate needed for real-time radio feeds. Sustained testing of 5 minutes confirmed stable performance with no memory leaks, establishing a reproducible benchmarking baseline for future edge-deployment optimization.

99 - GENERAL AND MISCELLANEOUS

Smart Charging of Fleet and Personal Electric Vehicles through Joint Vehicle-to-Grid Optimization

As electric vehicle (EV) adoption accelerates, vehicle-to-grid (V2G) strategies offer advantages over unmanaged charging (V0G) by enhancing grid stability, reducing fleet operation costs, and supporting integration of variable generation resources. This research develops a day-ahead optimization framework linked with agent-based simulations to evaluate coordinated V2G participation by fleet and personal EVs under 5 energy-pricing settings in Austin, Texas. Three scenarios (V0G, fleet-only V2G, and joint-V2G) are examined, considering real-time price and grid profiles, health-damage costs, and operational constraints for both fleet and personal EVs. Results show how V2G scenarios shift fleet EV charging to mid-day while enabling strategic battery-discharge during evening peaks, mitigating grid stress and lowering EV energy costs. V2G delivers close to 80% energy-cost savings for a 2000-EV fleet in Austin on grid-stressed days, with 55% lower charging pollutant outputs. Joint-V2G amplifies system-level benefits by complementing fleet discharge, but smart-charging equipment costs can offset those benefits.

Electric vehicle

Maximizing Free Energy Gain

Maximizing the amount of work harvested from an environment is important for a wide variety of biological and technological processes, from energy-harvesting processes such as photosynthesis to energy storage systems such as fuels and batteries. Here, we consider the maximization of free energy—and by extension, the maximum extractable work—that can be gained by a classical or quantum system that undergoes driving by its environment. We consider how the free energy gain depends on the initial state of the system while also accounting for the cost of preparing the system. We provide simple necessary and sufficient conditions for increasing the gain of free energy by varying the initial state. We also derive simple formulae that relate the free energy gained using the optimal initial state rather than another suboptimal initial state. Finally, we demonstrate that the problem of finding the optimal initial state may have two distinct regimes, one easy and one difficult, depending on the temperatures used for preparation and work extraction. We illustrate our results on a simple model of an information engine.

Physics

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY

A Full-Induction Magnetohydrodynamics Solver for Liquid Metal Fusion Blankets in Vertex-CFD

Multiphysics modeling of liquid metal fusion blankets, which produce tritium and convert energy of neutrons created via fusion reactions into heat, is crucial for predicting performance, ensuring structural integrity, and optimizing energy production. While traditional blanket modeling of liquid metal flows during normal steady operating conditions commonly employs the inductionless approximation of the magnetohydrodynamics (MHD) equations, transient scenarios, when the plasma-confining magnetic field varies on millisecond time scales, require a full-induction MHD approach that dynamically evolves the magnetic field via the time-dependent induction equation. This paper presents the formulation, implementation, and initial verification of a full-induction MHD solver integrated within the open-source Vertex-CFD framework, which aims to achieve tight multiphysics coupling, a flexible software design enabling easy extension and addition of physics models, and performance portability across computing platforms. The solver utilizes finite element spatial discretization, implicit Runge–Kutta time integration, and an inexact Newton method to solve the resulting discrete nonlinear system, leveraging Trilinos packages for efficient computation. Verification against selected benchmark problems demonstrates accuracy and robustness of the solver. Furthermore, when the solver is applied to an idealized blanket model in 2.5D and full 3D, results obtained with Vertex-CFD are in good agreement with recently published quasi-2D simulations. These findings establish a computational foundation for future simulations of transient MHD phenomena in liquid metal blankets with Vertex-CFD, and open avenues for future extensions and performance optimizations.

Endeve, Eirik [ORNL] (ORCID:0000000312519507)

Assembly and Testing of Scintillator Tile Modules for the CMS High-Granularity Calorimeter Upgrade

The High-Granularity Calorimeter (HGCAL), part of the upgrade to the Compact Muon Solenoid (CMS) experiment, employs silicon and scintillator tile modules in the endcaps to maintain detector performance during the High-Luminosity Large Hadron Collider (HL-LHC) era, scheduled to operate from 2030 to 2040. The upgraded calorimeter will provide highly segmented three-dimensional imaging, energy measurements, and precise timing for particle shower reconstruction. Approximately half of the HGCal plastic scintillator tile modules (1,834 total) will be assembled at Fermilab using an automated pick-and-place (PnP) machine. Following assembly, each tile module undergoes quality control (QC) procedures such as electrical validation, thermal testing, and physics validation using cosmic rays. This poster/talk presents the QC procedures and results from the tile module production in 2026, demonstrating the performance and quality of the assembled tile modules.

Bazimya, Jean Luc [Grambling State U.]

Update on Radiochemical Assessment of High Burnup Commercially Irradiated Fuel

This work documents an effort to collect burnup measurements on a high burnup rod, designated 6XV, and first cycle accident tolerant fuel (ATF) rod, designated 47I, to enable benchmarking of fuel performance codes and neutronics codes. In addition to measurements, Virtual Environment for Reactor Applications (VERA) full-core-depletion analysis was also performed for the rods that were experimentally analyzed to provide an opportunity for code validation. This effort focuses on collecting data from rods irradiated at Byron Generating Station and shipped to the Oak Ridge National Laboratory (ORNL) hot-cells. This data will also anchor non-destructive examination evaluations of burnup of the various fuel rods undergoing postirradiation examination (PIE) at ORNL. Previous PIE of these fuel rods provides some guidance on the burnup trend across the fuel. Axial gamma spectroscopy scans provide a measure of relative changes in burnup across a fuel pin. Mass spectrometry based burnup measurements performed for this work at specific axial locations in the fuel are fully quantitative. By combining the mass spectrometry data with the gamma scans it is possible to more quantitatively evaluate axial variations in burnup across the entire fuel pin [1]. The combined set of burnup evaluations will be made available to other organizations that have an interest in high burnup radiochemistry data for validation of neutronic simulations and source term evaluation such as the Nuclear Regulatory Commission (NRC).

Harp, Jason [Oak Ridge National Laboratory (ORNL),

Geospatial modeling of near subsurface temperatures of the contiguous United States for assessment of materials degradation

Abstract Understanding subsurface temperature variations is crucial for assessing material degradation in underground structures. This study maps subsurface temperatures across the contiguous United States for depths from 50 to 3500 m, comparing linear interpolation, gradient boosting (LightGBM), neural networks, and a novel hybrid approach combining linear interpolation with LightGBM. Results reveal heterogeneous temperature patterns both horizontally and vertically. The hybrid model performed best achieving a root mean square error of 2.61 °C at shallow depths (50–350 m). Model performance generally decreased with depth, highlighting challenges in deep temperature prediction. State-level analyses emphasized the importance of considering local geological factors. This study provides valuable insights for designing efficient underground facilities and infrastructure, underscoring the need for depth-specific and region-specific modeling approaches in subsurface temperature assessment.

Science & Technology - Other Topics

Mechanistic Understanding of Interphase-driven Aging in Silicon Anodes

Conventional solid electrolyte interphases (SEIs) strongly adhere to micro-silicon (µ-Si) and crack under volume changes, causing poor cycling performance. Nano-silicon improves cycling performance but remains costly with limited calendar life. Here potentiostatic ageing tests demonstrate that both calendar and cycle ageing are governed by SEI cracking and dissolution with different relative contributions. When the system is not dominated by SEI dissolution, the relative calendar life of Si anodes could correlates positively with their cycle life. LiF-rich SEI that enables long cycle life in µ-Si is therefore expected to enhance calendar life as well. Using this framework, we screened electrolytes, SEIs and electrodes and validated them with full-cell storage. LiF-rich SEI minimizes cracking and dissolution, enabling μ-Si to achieve excellent calendar life, whereas nano-silicon suffers from SEI dissolution and needs reduced electrolyte–electrode contact for better calendar life. This work clarifies calendar-ageing behaviour and accelerates electrolytes and SEI development for long-life Si anodes.

Johnson, Christopher S.

Self-Leveling Inks for Printing Ultra-uniform Perovskite Solar Modules by Flexography

The report describes the development of scalable manufacturing methods for high-performance, stable perovskite solar modules using flexographic printing. The project developed self-leveling perovskite inks that exploit Marangoni flows to reduce coating defects and improve large-area film uniformity. Bayesian optimization was integrated with high-throughput photoluminescence mapping and photovoltaic measurements to efficiently optimize ink formulations and printing conditions. The resulting printed perovskite solar cells achieved champion power conversion efficiencies above 21.6%, with median efficiencies exceeding 20% across large device batches. At the module scale, printed devices achieved active-area efficiencies up to approximately 17.3% on 25 cm² substrates. The project also demonstrated improved performance and stability using additively patterned interconnections compared with laser-scribed controls. Overall, the work establishes a data-driven, roll-compatible pathway toward high-throughput, low-capital-cost manufacturing of uniform and stable perovskite photovoltaics.

14 SOLAR ENERGY

STANDARD REFERENCE MATERIAL CHARPY TESTING FROM HIGH FLUENCE SURVEILLANCE CAPSULE

The Palisades Nuclear Generating Station included in its original surveillance program a surveillance capsule, designated A-60. The capsule was removed from its surveillance position in early 1995 and has been resident in the spent fuel pool since that time. It was harvested to perform characterization of surveillance specimens in this capsule in 2023. This capsule was irradiated to a fluence of 1.96x1020 n/cm2 (E> 1MeV) that is equivalent for more than 150 effective full power years for the current US reactor pressure vessel (RPV) fleet. This capsule contained several materials, including Charpy specimens of standard reference material (SRM) from Heavy-Section Steel Technology (HSST) A533-B Plate 01. To perform Charpy testing of this highly irradiated material, the new Charpy specimen transfer system was designed and implemented on Charpy impact testing machine in the hot cell to accommodate remote testing of these specimens. This new transfer system includes integrated environmental chamber to cool or heat Charpy specimens to the desired temperature. Testing of this highly irradiated material revealed very large shift of Charpy transition temperature, 188oC.

Sokolov, Mikhail [ORNL] (ORCID:0000000256373346)

Mu2e Production Target Thermal Test Project

The Mu2e experiment requires a production target that is capable of operating under extreme thermal conditions caused by an 8 GeV proton beam. This project’s objective supports the development of the Mu2e Pro- duction Target by testing the Stickman model’s thermal behavior. Angel Flores Luviano has assisted Jonathan Williams in progressing this project by contributing to the development of a Radiative Cooling Test Fixture (RCTF) that will be used to evaluate the thermal behavior of the new production target model. Engineering calculations were performed to an- alyze thermal performance and pressure drop within the cold well and wa- ter cooling circuit. These calculations also determined the optimal sizing for key components of the water system. An engineering note was made to document these calculations. CAD models of the water circuit piping, thermocouple mounting bars, and radiator chimney were developed, and prototype test rig components were fabricated using 3D printing. Future work will focus on continued RCTF development which includes control system integration, heater hardware design, and interfaces that can be scaled up to increase thermal capacity.

Flores Luviano, Angel Augusto [Unlisted, US]

Field Validation of a Grid-Interactive Efficient Building Software Solution

The U.S. General Services Administration's (GSA's) Green Proving Ground (GPG) program, in partnership with the National Laboratory of the Rockies (NLR), completed a field study of a Grid-Interactive Efficient Buildings (GEB) software solution. The study focused on a single testbed facility to test the GEB functionality of the software solution, along with other features. The testbed facility - a courthouse - is a common building type in GSA's vast building portfolio, offering potentially impactful findings on a scalable level. The study evaluated Prescriptive Data's technology, Nantum OS, a connected building operating system ("GEB Solution") which aggregates multiple sources of previously siloed building data and combines that data with external sources, such as weather information or utility signals, into a single integrated platform. A GEB Solution is a type of Energy Management Information System (EMIS). EMIS is defined as a system of devices, data services, and software applications that communicates with any building system or third-party data source to aggregate and transform data into new capabilities to aid in the optimization of energy use at the building, campus, or agency level. This specific GEB Solution is an EMIS with ASO, automated system optimization, offering supervisory control of certain aspects of the Building Automation System (BAS). Multiple features were evaluated including, but not limited to, Continuous Demand Management to avoid setting new monthly kilowatt (kW) peaks, energy efficiency for reduction of kilowatt hours (kWh) and natural gas consumption, and automated demand response (ADR) for purposes of lowering demand during a utility called Demand Response (DR) event. The testbed facility was the Foley Federal Building and US Courthouse ("Foley Federal Building") located in Las Vegas, NV. This is a 209,496 sq. ft. building constructed in the 1960s with major renovations in 2004. The facility was a good candidate due to the large prevalence of office and courthouse spaces in the GSA portfolio of buildings. It also has many features which allow integration into and control of the building and a strong facilities team to assist with the study. Quantitative and qualitative performance objectives were developed using GSA's GPG GEB project template along with input from the vendor and building facility staff; these are outlined in Table 1. The quantitative performance objectives focused on continuous demand management, energy efficiency, and automated demand response. The qualitative performance objectives focused on the ease of installation and commissioning as well as the operability of the GEB solution. Other performance metrics that are reported on include carbon reduction, cost effectiveness, and occupant acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

CO2 Handling & Electrolyzer Efficiency Scaling Evaluator

CHEESE is an interactive dashboard tool for estimating the performance and material requirements of carbon dioxide electrolysis systems. It helps users evaluate how electrode area, current density, product selectivity, gas flow, cell voltage, and the number of cells in a stack affect system operation. The dashboard provides simple and advanced modes so it can be used for both quick estimates and more detailed engineering analysis. Users can estimate product output, carbon dioxide use, electrical power, electrode area, gas and liquid flow rates, energy efficiency, material cost per test, and the effect of scaling from a single cell to a multi cell stack. It also includes tools for examining carbon balance, equipment durability, component replacement, and changes in performance over time. This is intended to help both academia and industry researchers who are either getting into CO2 electrolysis on lab-scale or are trying to establish a larger footprint. CHEESE presents results through tables, charts, and simplified cell and stack diagrams. It is intended to support research planning, experimental design, comparison of operating conditions, and early stage scale up studies.

Prajapati, Aditya [Lawrence Livermore National Lab

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI