Environmental Test Screening Procedure

This procedure describes the methods to be used for environmental stress screening (ESS) of the Lightning Mapper Sensor (LMS) lens assembly. Unless otherwise specified, the procedures shall be completed in the order listed, prior to performance of the Acceptance Test Procedure (ATP). The first unit, S/N 001, will be subjected to the Qualification Vibration Levels, while the remainder will be tested at the Operational Level. Prior to ESS, all units will undergo Pre-ESS Functional Testing that includes measuring the on-axis and plus or minus 0.95 full field Modulation Transfer Function and Back Focal Length. Next, all units will undergo ESS testing, and then Acceptance testing per PR 460.

Zeidler, Janet↗

Orbiter Reinforced Carbon-Carbon Advanced Sealant Systems: Screening Tests

Oxidation protection for the Orbiter reinforced carbon-carbon (RCC consists of three components: silicon carbide coating, tetraethyl orthosilicate (TEOS) impregnated into the carbon substrate and a silicon based surface sealant (designated Type A). The Orbiter Type A sealant is being consumed each mission, which results in increased carbon-carbon substrate mass loss, which adversely impacts the mission life of the RCC components. In addition, the sealant loss in combination with launch pad contamination (salt deposit and zinc oxide) results in RCC pinholes. A sealant refurbishment schedule to maintain mission life and minimize affects of pin hole formation has been implemented in the Orbiter maintenance schedule. The objective of this investigation is to develop an advanced sealant system for the RCC that extends the refurbishment schedule by reducing sealant loss/pin hole formation and that can be applied to existing Orbiter RCC components. This paper presents the results of arc jet screening tests conducted on several sealants that are being considered for application to the Orbiter RCC.

Curry, Donald M.↗

Inertial Screening in Sedimentation

Using particle image velocimetry we have measured the sedimentation dynamics of non-Brownian spheres over a wide range of Reynolds numbers (Re) between 0.001 and 2.5. Particle velocity fluctuations about the mean settling velocity show large-scale correlations whose spatial extent and magnitude Delta V/V are independent of Re up to a critical value Re less than Re(sub c). For Re greater than Re(sub c) the fluctuations substantially diminish with increasing Reynolds number due to inertial screening of the long-range hydrodynamic interactions (HI). The onset of inertial affects is found to occur when the Oseen length l(sub o)=v/V becomes of order the correlation length. In the inertial regime, the velocity fluctuations follow -(Delta V/V)(sup 2) approaching ln(Re), in agreement with an integration of the (l/r) HI over a narrow region extending up to the Oseen length l(sub o). A simple "blob" model connects the measured correlation lengths to the magnitudes of the velocity fluctuations.

Segre, P. N.↗

DMA Modulus as a Screening Parameter for Compatibility of Polymeric Containment Materials with Various Solutions for use in Space Shuttle Microgravity Protein Crystal Growth (PCG) Experiments

Protein crystals are grown in microgravity experiments inside the Space Shuttle during orbit. Such crystals are basically grown in a five-component system containing a salt, buffer, polymer, organic and water. During these experiments, a number of different polymeric containment materials must be compatible with up to hundreds of different PCG solutions in various concentrations for durations up to 180 days. When such compatibility experiments are performed at NASA/MSFC (Marshall Space Flight Center) simultaneously on containment material samples immersed in various solutions in vials, the samples are rather small out of necessity. DMA4 modulus was often used as the primary screening parameter for such small samples as a pass/fail criterion for incompatibility issues. In particular, the TA Instruments DMA 2980 film tension clamp was used to test rubber O-rings as small in I.D. as 0.091 in. by cutting through the cross-section at one place, then clamping the stretched linear cord stock at each end. The film tension clamp was also used to successfully test short length samples of medical/surgical grade tubing with an O.D. of 0.125 in.

Wingard, Charles Doug↗

Calibration of the Oscillating Screen Viscometer

We have devised a calibration procedure for the oscillating screen viscometer which can provide the accuracy needed for the flight measurement of viscosity near the liquid-vapor critical point of xenon. The procedure, which makes use of the viscometer's wide bandwidth and hydrodynamic similarity, allows the viscometer to be self-calibrating. To demonstrate the validity of this procedure we measured the oscillator's transfer function under a wide variety of conditions. We obtained data using CO2 at temperatures spanning a temperature range of 35 K and densities varying by a factor of 165, thereby encountering viscosity variations as great as 50%. In contrast the flight experiment will be performed over a temperature range of 29 K and at only a single density, and the viscosity is expected to change by less than 40%. The measurements show that, after excluding data above 10 Hz (where frequency-dependent corrections are poorly modeled) and making a plausible adjustment to the viscosity value used at high density, the viscometer's behavior is fully consistent with the use of hydrodynamic similarity for calibration. Achieving this agreement required understanding a 1% anelastic effect present in the oscillator's torsion fiber.

Berg, Robert F.↗

Effect of Bulk Viscosity on the Oscillating Screen Viscometer

Close to the critical temperature, the bulk viscosity of the xenon sample will exceed the shear viscosity by more than a factor of a billion. Nevertheless, the viscometer's low operating frequency ensures that the only significant force on the oscillating screen will be due to the shear viscosity.

Berg, Robert F.↗

Nonhydrodynamic Characteristics of the Oscillating Screen Viscometer

Extraction of the viscosity from the oscillating screen's response function requires knowledge of it resonance frequency omega(sub 0) and of the prefactor k(sub tr)/k(theta), where k(sub tr) is a transducer coefficient and k(sub theta) is the torsion spring constant. The determination of these parameters is described. The effect of a possible anomaly in the dielectric constant near the critical point of xenon will be negligible.

Berg, Robert F.↗

The Shuttle's Vibration Environment is Compatible with the Oscillating Screen Viscometer

The oscillating screen viscometer is designed for useful operation in the vibration environment of the Space Shuttle. The following analysis compares recently analyzed on-orbit vibration data against the viscometer's measured vibration sensitivity. During routine crew activities the effect of the resulting vibration on the precision of the viscosity measurement will be tolerable. However, there is a possible problem if the astronauts use unisolated exercise equipment for extended periods of time.

Berg, Robert F.↗

On the Use of Accelerated Aging Methods for Screening High Temperature Polymeric Composite Materials

A rational approach to the problem of accelerated testing of high temperature polymeric composites is discussed. The methods provided are considered tools useful in the screening of new materials systems for long-term application to extreme environments that include elevated temperature, moisture, oxygen, and mechanical load. The need for reproducible mechanisms, indicator properties, and real-time data are outlined as well as the methodologies for specific aging mechanisms.

Gates, Thomas S.↗

Oxygen Compatibility Screening Tests in Oxygen-Rich Combustion Environment

The identification and characterization of oxygen-rich compatible materials enables full-flow, staged combustion designs. Although these oxygen-rich designs offer significant cost, performance, and reliability benefits over existing systems, they have never been used operationally by the United States. If these systems are to be realized, it is critical to understand the long-term oxidative stability in high-temperature, high-pressure, oxygen-rich combustion environments. A unique facility has been constructed at the NASA Lewis Research Center to conduct tests of small-scale rocket engine materials and subcomponents in an oxygen-rich combustion environment that closely approximates a full-scale rocket engine. Thus, a broad range of advanced materials and concepts can be screened in a timely manner and at a relatively low cost.

Eckel, Anerew J.↗

Arc Jet Screening Tests Of Phase 1 Orbiter Tile Repair Materials and Uncoated RSI High Temperature Emittance Measurements

Arc jet tests of candidate tile repair materials and baseline Orbiter uncoated reusable surface insulation (RSI) were performed in the Johnson Space Center's (JSC) Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF) from June 23, 2003, through August 19, 2003. These tests were performed to screen candidate tile repair materials by verifying the high temperature performance and determining the thermal stability. In addition, tests to determine the surface emissivity at high temperatures and the geometric shrinkage of bare RSI were performed. In addition, tests were performed to determine the surface emissivity at high temperatures and the geometric shrinkage of uncoated RSI.

DelPapa, Steven V.↗

Screening and Identification of Cryopreservative Agents for Human Cellular Biotechnology Experiments in Microgravity

Dimethyl sulfoxide (DMSO) has been used as a standard cryopreservative agent for mammalian cell culture; however, prolonged exposure of thawed cells to DMSO can alter cell growth. While DMSO is easily eliminated in ground-based experiments, removal of DMSO in flight-based experiments is more difficult due to various on-orbit constraints. Failure of cryopreservation is due to a number of factors, including intracellular ice formation, solute effect, and apoptotic cell death following thawing. One objective of this study is to identify and characterize an alternative cryopreservative that could be used on the International Space Station (ISS). We systematically screened for potential permeating and non-permeating agents using a human colorectal carcinoma cell line, MIP-101. Cells were suspended in cryopreservation solution and frozen either following a two-step procedure involving initial cooling at -1 C/min overnight followed by storage in liquid nitrogen (LN2) vapor, or by freezing cells directly in the LN2 vapor phase at -10 C/min. Ability to preserve cellular function after one cycle of freeze-thawing was assessed by the recovery of viable cells in short and long-term cell culture experiments. Results showed that permeating preservatives glycerol (G) and ethylene glycol (EG) had an efficacy (80-110%) comparable to, if not better than, 7.5% DMSO; but, propylene glycol (PG) had a somewhat lesser efficacy. Among the non-permeating preservatives, trehalose, raffinose, and dextran exhibited significant protective effect (50-80%) relative to that offered by 7.5% DMSO, but at -10 C and not at -1 C/min cooling rate. Preliminary data thus suggest that a combination of permeating and non-permeating agents may have improved efficacy as a cryoprotectant and serve as an alternate to DMSO for experimentation on ISS.

Love,J.↗

Environmental Stress Screening 2000

The following identifies the authors of this report and the organizations that sponsored the effort conducted under the National Center for Manufacturing Sciences (NCMS) Environmental Stress Screening (ESS) 2000 Project.

Environment↗

Usefulness of Derived Frank Lead Parameters in Screening for Coronary Artery Disease and Cardiomyopathy

We investigated the accuracy of several known as well as newly-introduced derived Frank-lead ECG parameters in differentiating healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. The following derived Frank lead parameters were studied for their accuracy in detecting CAD and CM: the spatial ventricular gradient (VG), including its beat-to-beat coefficient of variability (VG CV); the spatial mean QRS (SM-QRS) and T-waves (SM-T) and their beat-to-beat coefficients of variability; the spatial ventricular activation time (VAT); the mean and maximum spatial QRS-T angles; and standard late potentials parameters (RMS40, fQRSD and LAS). Several of these parameters were accurate in discriminating between the control group and both diseased groups at p less than 0.0001. For example the fQRSD, VG CV, mean spatial QRS-T angle and VG minus SM-QRS (which is similar to the SM-T) had retrospective areas under the ROC curve of 0.78, 0.78, 0.80, and 0.84 (CAD vs. controls) and 0.93, 0.88, 0.98 and 0.99 (CM vs. controls), respectively. The single most effective parameter in discriminating between the CAD and CM groups was the spatial VAT (44 plus or minus 5.8 vs. 53 plus or minus 9.9 ms, p less than 0.0001), with an area under the ROC curve of 0.80. Since subsequent prospective analyses using new groups of patients and healthy subjects have yielded only slightly less accurate results, we conclude that derived Frank-lead parameters show great promise for potentially contributing to the development of a rapid and inexpensive resting ECG-based screening test for heart disease.

DePalma, J. L.↗

Construction and Use of Resting 12-Lead High Fidelity ECG "SuperScores" in Screening for Heart Disease

We investigated the accuracy of several conventional and advanced resting ECG parameters for identifying obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. Multiple conventional and advanced ECG parameters were studied for their individual and combined retrospective accuracies in detecting underlying disease, the advanced parameters falling within the following categories: 1) Signal averaged ECG, including 12-lead high frequency QRS (150-250 Hz) plus multiple filtered and unfiltered parameters from the derived Frank leads; 2) 12-lead P, QRS and T-wave morphology via singular value decomposition (SVD) plus signal averaging; 3) Multichannel (12-lead, derived Frank lead, SVD lead) beat-to-beat QT interval variability; 4) Spatial ventricular gradient (and gradient component) variability; and 5) Heart rate variability. Several multiparameter ECG SuperScores were derivable, using stepwise and then generalized additive logistic modeling, that each had 100% retrospective accuracy in detecting underlying CM or CAD. The performance of these same SuperScores was then prospectively evaluated using a test set of another 120 individuals (40 new individuals in each of the CM, CAD and control groups, respectively). All 12-lead ECG SuperScores retrospectively generated for CM continued to perform well in prospectively identifying CM (i.e., areas under the ROC curve greater than 0.95), with one such score (containing just 4 components) maintaining 100% prospective accuracy. SuperScores retrospectively generated for CAD performed somewhat less accurately, with prospective areas under the ROC curve typically in the 0.90-0.95 range. We conclude that resting 12-lead high-fidelity ECG employing and combining the results of several advanced ECG software techniques shows great promise as a rapid and inexpensive tool for screening of heart disease.

Schlegel, T. T.↗

Subscale Ship Airwake Studies Using Novel Vortex Flow Devices with Smoke, Laser-Vapor-Screen and Particle Image Velocimetry

Ships produce vortices and air-wakes while either underway or stationary in a wind. These flow fields can be detrimental to the conduction of air operations in that they can adversely impact the air vehicles and flight crews. There are potential solutions to these problems for both frigates/destroyers and carriers through the use of novel vortex flow or flow control devices. This appendix highlights several devices which may have application and points out that traditional wind-tunnel testing using smoke, laser-vapor screen, and Particle Image Velocimetry can be useful in sorting out the effectiveness of different devices.

Lamar, John E.↗