Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Filter Measurement System for Nuclear Material Storage Canisters. End of Year Report FY 2013

A test system has been developed at Los Alamos National Laboratory to measure the aerosol collection efficiency of filters in the lids of storage canisters for special nuclear materials. Two FTS (filter test system) devices have been constructed; one will be used in the LANL TA-55 facility with lids from canisters that have stored nuclear material. The other FTS device will be used in TA-3 at the Radiation Protection Division’s Aerosol Engineering Facility. The TA-3 system will have an expanded analytical capability, compared to the TA-55 system that will be used for operational performance testing. The LANL FTS is intended to be automatic in operation, with independent instrument checks for each system component. The FTS has been described in a complete P&ID (piping and instrumentation diagram) sketch, included in this report. The TA-3 FTS system is currently in a proof-of-concept status, and TA-55 FTS is a production-quality prototype. The LANL specification for (Hagan and SAVY) storage canisters requires the filter shall “capture greater than 99.97% of 0.45-micron mean diameter dioctyl phthalate (DOP) aerosol at the rated flow with a DOP concentration of 65±15 micrograms per liter”. The percent penetration (PEN%) and pressure drop (DP) of fifteen (15) Hagan canister lids were measured by NFT Inc. (Golden, CO) over a period of time, starting in the year 2002. The Los Alamos FTS measured these quantities on June 21, 2013 and on Oct. 30, 2013. The LANL(6-21-2013) results did not statistically match the NFT Inc. data, and the LANL FTS system was re-evaluated, and the aerosol generator was replaced and the air flow measurement method was corrected. The subsequent LANL(10-30-2013) tests indicate that the PEN% results are statistically identical to the NFT Inc. results. The LANL(10-30-2013) pressure drop measurements are closer to the NFT Inc. data, but future work will be investigated. An operating procedure for the FTS (filter test system) was written, and future project milestones are on track for completion

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing Instrument Extremes in the TREAT Facility

TREAT is a transient power-shaping reactor whose primary mission is to enhance safety performance by testing nuclear fuels and materials under thermodynamic and neutronic conditions ranging from off-normal to extreme. Transient testing of nuclear fuels is analogous to car crash testing, in that the dramatic changes commonly seen when comparing the test specimens' initial and final state points necessitate in-situ measuring in order to interpret and understand the evolution of the experiment. TREAT’s experiment design strategy utilizes a highly reconfigurable and accessible reactor core that affords flexibility when installing experiment devices, thanks to the lack of a primary coolant boundary and the inclusion of multiple access points in the reactor bioshield. Within the experiment devices, the test specimens (which are integrated with their test environments), desired instrumentation diagnostics, and safety considerations are all contained in a single engineered package. The experiments encompass various types of environments (e.g., water, sodium, and gas at temperature and pressure), as well as a range of control options (e.g., static or flowing coolants). The experimental conditions are uniquely representative of advanced reactors, providing challenges to sensor performance but also affording a unique opportunity for development and qualification of sensors suited to these environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE AUTOIGNITION OF CYCLOPENTANE IN AN IGNITION QUALITY TESTER

Cyclopentane, a flammable hydrocarbon, is being considered as a working fluid for waste heat recovery applications using Organic Rankine Cycles with Direct Evaporators. A postulated failure mode consisting of a pinhole leak in a heat exchanger tube raises safety concerns due to autoignition of the working fluid. The ignition delay time (IDT) of cyclopentane was measured using an Ignition Quality Test™ (IQT™) device. Hot, vitiated air was used to simulate turbine exhaust gas (TEG). Experiments were conducted in accordance with ASTM D6890 (with exception to charge pressure and temperature) to determine ignition delay of the fuel at atmospheric pressure for vitiated air (13.3% oxygen). The test matrixencompassed equivalence ratios from 0.5 to 5.0 and chamber temperatures ranging from 673 to 823 K to establish a set of ignition delay curves. IDT was observed to decrease with increasing temperature and equivalence ratio. For the cases tested, no ignition was observed at temperatures at or below 723 K or at an equivalence ratio of 0.5.

42 ENGINEERING↗

Evaluating Impacts of Battery Energy Storage System Functionalities on Distribution Systems Using Power Hardware in-the-Loop Simulation: Preprint

In this paper, we present results from a power hardware-in-the-loop (PHIL) simulation that was performed to test and demonstrate the impact of a battery energy storage system (BESS) on a distribution feeder. The PHIL platform includes a simulated distribution grid in a real-time digital simulator (RTDS), AC and DC power amplifiers, and a battery inverter as the device under test. Guidelines of specific procedures to set up a PHIL platform are provided on how to set up a PHIL platform to evaluate the impact of grid integrated systems. Accelerated time-series PHIL simulations of peak shaving and Volt/Var functionalities were performed using a 540 kVA BESS. These experimental results illustrate how PHIL simulations can be used to evaluate the impact of BESS functionalities on the distribution grid prior to installation in the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Overview of the Hybrid Illinois Device for Research and Applications Material Analysis Test-stand (HIDRA-MAT)

The Hybrid Illinois Device for Research and Applications (HIDRA) at the University of Illinois at Urbana-Champaign is a toroidal plasma device that enables fusion plasma-material interaction testing with both stellarator and tokamak plasmas. HIDRA’s long-pulse steady state stellarator plasmas provide a testbed for plasma facing component (PFC) plasma exposures. The HIDRA Material Analysis Test-stand (HIDRA-MAT) is a material characterization module attached to HIDRA that is being designed and fabricated to include thermal desorption spectroscopy and laser induced breakdown spectroscopy systems for in-vacuo PFC characterization. A specialized rotatable sample holder positions the sample for liquid metal droplet application from a liquid metal droplet injector on HIDRA-MAT. Early experiments look to investigate the effect liquid lithium has on porous tungsten samples’ retention of H, D, and He after plasma exposure. Preliminary results from a dual residual gas analyzer system show the ability to differentiate D2 and He in HIDRA-MAT. Finally, this work aims to advance the understanding of liquid metal PFCs and further the design and development of new fusion PFCs and technologies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Device and material investigations of GaN enhancement-mode transistors for Venus and harsh environments

This Letter reports the device and material investigations of enhancement-mode p-GaN-gate AlGaN/GaN high electron mobility transistors (HEMTs) for Venus exploration and other harsh environment applications. The GaN transistor in this work was subjected to prolonged exposure (11 days) in a simulated Venus environment (460 °C, 94 bar, complete chemical environment including CO2/N2/SO2). The mechanisms affecting the transistor performance and structural integrity in harsh environment were analyzed using a variety of experimental, simulation, and modeling techniques, including in situ electrical measurement (e.g., burn-in) and advanced microscopy (e.g., structural deformation). Through transistor, Transmission Line Method (TLM), and Hall-effect measurements vs temperature, it is revealed that the mobility decrease is the primary cause of reduction of on-state performance of this GaN transistor at high temperature. Material analysis of the device under test (DUT) confirmed the absence of foreign elements from the Venus atmosphere. No inter-diffusion of the elements (including the gate metal) was observed. The insights of this work are broadly applicable to the future design, fabrication, and deployment of robust III-N devices for harsh environment operation.

Physics↗

Interaction of ultrashort laser pulses and silicon solar cells under short circuit conditions

Ultrashort pulse lasers are promising tools for numerous measurement purposes. Among other benefits their high peak powers allow for efficient generation of wavelengths in broad spectral ranges and at spectral powers that are orders of magnitude higher than in conventional light sources. Very recently this has been exploited for the establishment of sophisticated measurement facilities for electrical characterization of photovoltaic (PV) devices. As the high peak powers of ultrashort pulses promote nonlinear optical effects they might also give rise to nonlinear interactions with the devices under test that possibly manipulate the measurement outcome. In this paper, we present a comprehensive theoretical and experimental study of the nonlinearities affecting short circuit current (I{sub SC}) measurements of silicon (Si) solar cells. We derive a set of coupled differential equations describing the radiation-device interaction and discuss the nonlinearities incorporated in those. By a semi-analytical approach introducing a quasi-steady-state approximation and integrating a Green's function we solve the system of equations and obtain simulated I{sub SC} values. We validate the theoretical model by I{sub SC} ratios obtained from a double ring resonator setup capable for reproducible generation of various ultrashort pulse trains. Finally, we apply the model to conduct the most prominent comparison of I{sub SC} generated by ultrashort pulses versus continuous illumination. We conclude by the important finding that the nonlinearities induced by ultrashort pulses are negligible for the most common I{sub SC} measurements. However, we also find that more specialized measurements (e.g., of concentrating PV or Si-multijunction devices as well as highly localized electrical characterizations) will be biased by two-photon-absorption distorting the I{sub SC} measurement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improvement of Carbon Dioxide Sweep Efficiency by Utilization of Microbial Permeability Profile Modification to Reduce the Amount of Oil Bypassed During Carbon Dioxide Flood

The objective of this project was to couple microbial permeability profile modification (MPPM), with carbon dioxide flooding to improve oil recovery from the Upper Cretaceous Little Creek Oil Field situated in Lincoln and Pike counties, MS. This study determined that MPPM technology, which improves production by utilizing environmentally friendly nutrient solutions to simulate the growth of the indigenous microflora in the most permeable zones of the reservoir thus diverting production to less permeable, previously unswept zones, increased oil production without interfering with the carbon dioxide flooding operation. Laboratory tests determined that no microorganisms were produced in formation waters, but were present in cores. Perhaps the single most significant contribution of this study is the demonstration that microorganisms are active at a formation temperature of 115°C (239°F) by using a specially designed culturing device. Laboratory tests were employed to simulate the MPPM process by demonstrating that microorganisms could be activated with the resulting production of oil in coreflood tests performed in the presence of carbon dioxide at 66°C (the highest temperature that could be employed in the coreflood facility). Geological assessment determined significant heterogeneity in the Eutaw Formation, and documented relatively thin, variably-lithified, well-laminated sandstone interbedded with heavily-bioturbated, clay-rich sandstone and shale. Live core samples of the Upper Cretaceous Eutaw Formation from the Heidelberg Field, MS were quantitatively assessed using SEM, and showed that during MPPM permeability modification occurs ubiquitously within pore and throat spaces of 10-20 μm diameter. Testing of the MPPM procedure in the Little Creek Field showed a significant increase in production occurred in two of the five production test wells; furthermore, the decline curve in each of the production wells became noticeably less steep. This project greatly extends the number of oil fields in which MPPM can be implemented.

02 PETROLEUM↗

High-bandwidth, high-sampling-rate, low-noise, two-probe transient photovoltage measuring system

In this article, we present a two-probe configuration for measuring transient photovoltage (TPV) signals from photo-electronic semiconductor devices. Unlike in a conventional one-probe system, the two electrodes of the devices under test in this study are both monitored in our new measuring system, giving rise to a significantly enhanced signal-to-noise ratio. Tentative experimental data ob tained from N, N′-Di(1-naphthyl)-N,N′-diphenyl-(1,1′-biphenyl)-4,4′-diamine-based organic semiconductor devices show that the bandwidth and the sampling rate of the system reach 1.5 GHz and 50 GS/s, respectively, without degradation of the noise level. In addition, the study of TPV signals on each individual electrode is allowed. The TPV values measured by the two individual probes are not identically equal to half of the differential TPV and will not cancel each other out as expected. This abnormal phenomenon is due to the photoelectric response of the photo-electronic material. This novel two-probe TPV measuring technique and abnormal TPV behavior might be useful for studying more dynamic processes in photo-electronic semiconductors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Device for steam cladding oxidation testing at TREAT

To compare the chemical degradation of conventional zirconium alloy (Zry) cladding to advance silicon carbide (SiC) cladding in a post loss of coolant accident (LOCA) environment, new nuclear testing capabilities are necessary. The Transient Reactor Test (TREAT) Facility at Idaho National Laboratory (INL) has matured its transient fuel testing capabilities since its 2017 restart. The most recent experiment architecture is the Transient Water Irradiation System in TREAT (TWIST), which is designed to support qualification of accident tolerant fuels in light water reactors. INL has designed and analyzed a natural circulation steam flow modification for TWIST to produce prototypic conditions of cladding oxidation. The in-situ device will be electrically heated to drive natural circulation. Moreover, the SiC cladding requires heating above 1700 °C to observe failure, thus internal prototypic nuclear heating with radiation effects will be used. Thermal hydraulic analysis with RELAP5-3D (Reactor Excursion and Leak Analysis Program) estimated steam fluxes greater than 50 mg cm −2 s −1 can be achieved. These fluxes are adequate to test Zry cladding according to draft regulatory guides and to test SiC cladding according to past experiments.

Oxidation↗

Properties of HPK UFSD after neutron irradiation up to 6e15 n/cm 2

In this article we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15 and 6e15 neq/cm 2 . The UFSD used in this study are circular 50 μm thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. Hamamatsu Photonics (HPK), Japan, produced the UFSD with pre-irradiation internal gain in the range 5–70 depending on the bias voltage. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particles (MIPs) from a 90 Sr β-source. The leakage current, internal gain and the timing resolution were measured as a function of bias voltage at -20 °C and -30 °C. The timing resolution of each device under test was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction discriminator (CFD) method for both. The dependence of the gain upon the irradiation fluence is consistent with the acceptor removal mechanism; at -20 °C the highest gain decreases from 70 before radiation to 2 after a fluence of 6e15 n/cm 2 . Consequently, the timing resolution was found to deteriorate from 20 ps to 50 ps. The results indicate that the most accurate time resolution is obtained varying with fluence the CFD value used to determine the time of arrival, from 0.1 for pre-irradiated sensors to 0.6 at the highest fluence. Key changes to the pulse shape induced by irradiation, i.e. (i) the contribution of charge multiplication not limited to the gain layer zone, (ii) the shortening of the rise time and (iii) the reduced pulse height, were compared with the WF2 simulation program and were found to be in agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bond Wire Damage Detection and State of Health Estimation of a 1200V, 900A Dual Pack IGBT Power Module using the RL-Equivalent Circuit

Electrical and environmental stresses are the two dominant contributors in aging and failure of power semiconductor devices. Insulated gate bipolar junction transistors (IGBTs) and metal-oxide semiconductor field effect transistors (MOSFETs) are two most commonly used switching devices in power converter circuits. A significant portion of research effort is given in inventing innovative methods to estimate the degradation and fatigue in these devices. Until today, no other existing techniques can determine the number of lifted bond wires and their locations in a live IGBT module, although this information is extremely helpful to understand the overall state of health of an IGBT power module. In this paper, we have proposed a reflectometry-based technique to overcome this hurdle. The RL-equivalent circuit to represent a bond wire has been developed for the device under test and simulated in CST Studio Suite to measure the reflection amplitudes. Experimental results were obtained using a prototype reflectometry hardware, and both the simulation and experimental results have been compared. These results prove that with these two sets of measurements, it is possible to locate the aged device inside a module and detect the number of bond wire lift-offs associated to that device.

30 DIRECT ENERGY CONVERSION↗

Capabilities development for transient testing of advanced nuclear fuels at TREAT

The TREAT facility is a unique capability at the Idaho National Laboratory currently being prepared for resumption of nuclear transient testing. TREAT is an air-cooled reactor where the driver core is made up of urania dispersed in graphite blocks and encapsulated in zirconium alloy cans. In addition to the reactor itself, the foundation for TREAT's capabilities will also include a suite of irradiation vehicles and supporting infrastructure to provide the desired specimen boundary conditions while supporting a variety of instrumentation needs. Although TREAT historically supported all kinds of nuclear fuels, including LWR's, SFR's, space nuclear propulsion, research reactor plate-type fuels, and even fuels for use in the driver core of other transient test reactors, the majority of TREAT's more-recent experiment programs revolved around SFR's and sodium-environment test capsules and loops. MK-series loop experiment-specific test trains could be outfitted with a variety of instruments to monitor test and specimen conditions while the fast neutron hodoscope collected information about fuel movement before, during, and after transient excursions. The SERTTA (Static Environment Rodlet Transient Test Apparatuses) devices will be general purpose vehicles capable of providing inert gas, water (up to PWR conditions), steam, or perhaps even molten sodium environments within vessel-like capsules. The Multi-SERTTA vehicle design is particularly novel as it makes use of the full active core length in TREAT to test four small rodlets (∼12 cm length), each within its own hermetic boundary, it will be capable of housing pre-irradiated fuel specimens. Additional modules and adaptations of Multi-SERTTA will enable rapid loop pressure blowdown to simulate LOCA conditions. The Super-SERTTA, akin to the Multi-SERTTA will offer more possibilities for simulating transient phenomena.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

WE-D-BRA-03: Four-Dimensional Dose Reconstruction Through Retrospective Phase Determination Using Cine Images of Electronic Portal Imaging Device

Purpose: To test a method to reconstruct a four-dimensional (4D) dose distribution using the correlation of pre-calculated 4D electronic portal imaging device (EPID) images and measured cine-EPID images. Methods: 1. A phantom designed to simulate a tumor in lung (a polystyrene block with 3.0 cm diameter embedded in cork) was placed on a sinusoidally moving platform with 2 cm amplitude and 4 sec/cycle. Ten-phase 4D CT images were acquired for treatment planning and dose reconstruction. A 6MV photon beam was irradiated on the phantom with static (field size=5×8.5 cm{sup 2}) and dynamic fields (sliding windows, 10×10 cm{sup 2}, X1 MLC closing in parallel with the tumor movement). 2. 4D and 3D doses were calculated forwardly on PTV (1 cm margin). 3. Dose images on EPID under the fields were calculated for 10 phases. 4. Cine EPID images were acquired during irradiation. 5. Their acquisition times were correlated to the phases of the phantom at which irradiation occurred by inter-comparing calculated “reference” EPID images with measured images (2D gamma comparison). For the dynamic beam, the tumor was hidden under MLCs during a portion of irradiation time; the correlation performed when the tumor was visible was extrapolated. 6. Dose for each phase was reconstructed on the 4D CT images and summed over all phases. The summation was compared with forwardly calculated 4D and 3D dose distributions. Monte Carlo methods were used for all calculations. Results: For the open and dynamic beams, the 4D reconstructed doses showed the pass rates of 92.7 % and 100 %, respectively, at the isocenter plane given 3% / 3 mm criteria. The better agreement of the dynamic beam was from its dose gradient which blurred the otherwise sharp difference between forward and reconstructed doses. This also contributed slightly better agreement in DVH of PTV. Conclusion: The feasibility of 4D reconstruction was demonstrated.

60 APPLIED LIFE SCIENCES↗

A Novel Carotid Device for Embolic Diversion: Lessons Learned from a 'First in Man' Trial in Patients with Atrial Fibrillation

Purpose: This study was designed to investigate a novel device that was developed to direct emboli away from the internal carotid artery to the external carotid artery to prevent embolic stroke while avoiding the necessity for anticoagulation with warfarin. Methods: A stent-like, self-expandable filter was developed consisting of fine cobalt alloy mesh. After promising preclinical animal testing, the device was implanted into the common carotid artery extending into the external carotid artery in three patients with atrial fibrillation, each of whom were at high-risk for cerebral emboli and were suboptimal candidates for anticoagulation. Follow-up was performed clinically and with carotid duplex ultrasound. Results: The implantation was successful in all three patients. Unrestricted flow through the filter was demonstrated in each patient at 6 months by duplex sonography. However, at 7 months ultrasound demonstrated occlusion of the internal carotid artery filter in one patient, which was subsequently confirmed by angiography. Subtotal filter occlusion occurred in a second patient at 14 months. Neither patient had clinical symptoms. Both internal carotid arteries were successfully recanalized using standard angioplasty techniques without complication. The third patient had completely normal carotid blood flow at 29 months follow-up. Conclusions: Implantation of a novel device intended to divert emboli away from the internal carotid artery was feasible, but resulted in occlusive neointimal proliferation in two of three patients. These results demonstrate a discrepancy from the findings of preclinical animal studies and human investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A nano-structured ZnO film as diagnostic X-ray sensor

Currently some international organizations such as WHO and IAEA have shown concerns about the quality of diagnostic services in clinics and hospitals that use ionizing radiation. In fact, the IAEA recommend that the characteristics of the X-ray beam must be adjusted to obtain the highest quality of the radiographic image with the minimum exposure to the patient. Several types of detectors may be used for monitoring X-ray beams, such as: ionization chamber, photodiode, phototransistor, among others. Recently nano-structured films made of various types of metal oxide materials have been used for various technological applications. Accordingly, the purpose of this paper is to present a sort of device based on a nano-structured zinc oxide (ZnO) to operate as a diagnostic X-ray sensor. By depositing a thin film on the glass substrate some ZnO semiconductor samples were built by sputtering techniques and then mounted in a BNC type connector to perform the electrical characterization. To test the device, we choose a standard X-Ray beam, the RQR9 radiation quality, which is normally used as the tool and condition for calibrating diagnostic X-Ray instruments in the energy range of computed tomography, in accordance with the stated requirements of IEC 61267. A 6430 sub-femto-ammeter, Keithley, was used as electrometer to perform the output readings and simultaneously bias the ZnO sensor. Analysis of the angular dependence and the dose rate were performed to evaluate how the device responds under the RQR9 radiation spectra. Although the results have shown that the ZnO film presents a certain angular dependence, if an angle of incidence of photons is selected, the device displays reproducibility as X-ray sensor and has the feature of radiation hardness unlike other types of semiconductor electronic devices typically used as an X-ray detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Simplified Method for Predicting Shaker Voltage in IMMATs

Impedance Matched Multi-Axis Tests (IMMATs) can replicate in-service vibration induced stress more accurately than single axis shaker table tests as they can better match a part’s operational boundary conditions and excite it in multiple degrees of freedom simultaneously. Here, the shakers used in IMMATs are less powerful than shaker tables, so shaker force limits can be exceeded during tests if they are not placed adequately for the desired environment. The ability to predict shaker voltage and force before performing a test is, therefore, helpful in selecting shaker locations so that their limits are not exceeded. In this study, electrodynamic shakers were modeled as discrete electromechanical systems, and the shaker parameters were chosen to match experimentally obtained acceleration/voltage frequency response functions (FRFs). These models were coupled to a finite element model of the device under test (DUT) via dynamic substructuring, and the substructured model was demonstrated to accurately predict shaker voltage as well as the error in reproducing the environment at multiple accelerometer locations. A simple method called the FRF Multiplication method, in which the FRF of the substructured system is approximated as the product of two separate FRFs of the shaker and DUT respectively, was proposed and applied to the same system, yielding similar voltage and error predictions to those obtained using substructuring. Simple case studies were presented to explore the applicability of the proposed method, and it was demonstrated to have similar accuracy to the substructuring method in a range of cases. Additionally, we showed that while it was not possible to derive a unique model of the shakers from acceleration/voltage FRFs alone, the models that could be obtained were sufficient to predict test error almost perfectly and shaker voltage with less than 40 percent error.

42 ENGINEERING↗

Real-Time Testbed for Smart Grid Recloser Controller

The growing need for a low voltage recloser has become apparent due to the rise in requirements for a smart grid. This includes more detailed management of power flow forward (towards load) and backward (towards generation), source synchronization in real time, more indepth fault responses, and the use of green energy. The SEL-651R-2 relay is a device that can manage these needs, especially in fault response and synchronization, and is commonly used in systems called microgrids. Microgrids are distribution level systems that are able to operate separated from the main grid, are typically installed much closer to the load(s), and are fed by distributed energy resources (DERs), such as wind, solar or diesel generators. The SEL-651R-2 is normally used in the field with presets operative settings, but the Western Michigan University (WMU) Center for Interdisciplinary Research on Secure, Efficient and Sustainable Energy Technology (WMU InterEnergy Center) wished to test this device in its range of capabilities for microgrid application. A Hardware-In-the-Loop (HIL) testbed was implemented and used through the Real Time Digital Simulator (RTDS) using the RSCAD software to test the SEL-651R-2's use cases and functions. The testbed includes a microgrid with interconnection to a larger main grid, and the relay is meant to control the recloser at the point of common coupling (PCC) between the main grid and microgrid. The testbed shows how basic protections, reclosing, and synchronization checks function when handling faults that affect both the microgrid and the main grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗