Search NASA⌕ Search

SEARCH · Search NASA

Results for “PCB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

High-Speed Active Integrators for Magnetic Probes

This report discusses a low cost, easy to develop instrument to measure magnetic fields in pulsed solenoids used for the MagNIF pulse power system. The instrument is designed to integrate voltage signals from custom B-dot probes made from PCB inductor chips. The instrument is battery powered with ± 9V rails. Acceptable B-dot probe inputs range from mV to 20V with frequencies up to 4MHz. Details of the circuit design and practical considerations for working with high speed signals are discussed.

42 ENGINEERING↗

Brain-computer interfaces enabled by novel magnetometers (CRADA FP00007655 Final Report))

The work primarily focused on improving performance of magnetometers based on Acoustically Driven Ferromagnetic Resonance (ADFMR) as well as exploring and evaluating the market opportunities for such devices. Over the two year program, we were able to improve magnetometer performance by a factor of over 1000X, and were able to demonstrate the feasibility of scaling down a bench-scale implementation by developing a 4” x 4” printed circuit board (PCB) prototype. These advancements were achieved by making substantial improvements both in the core sensor technology as well as the detection circuitry that allows for readout of the sensor module.

42 ENGINEERING↗

kiloAMPS (Final Report)

This project aims to reduce the testing time of various electrochemical techniques for neural interface electrodes by developing an automated PCB design which would be capable of testing multiple interface electrodes in parallel. The system should be able to perform the full battery of electrochemical tests, though electrochemical impedance spectroscopy (EIS) will be of primary interest. Previous versions of this project have already improved upon traditional interface testing by automating many parts of the process, reducing the test time to around a day and requiring the technician to check up on the process once every six hours. A key bottleneck is that the electrode testing is still done sequentially. Testing time could be heavily reduced if electrodes could be tested in parallel.

42 ENGINEERING↗

System Response Characterization for a d–t Neutron Radiography System

We report the system response of a pixelated associated particle imaging (API) neutron radiography system. The detector readout currently consists of a 2x2 array of organic glass scintillator detectors, each with an 8x8 array of optically isolated pixels that match the size and pitch of the ARRAYJ-60035-64P-PCB Silicon Photomultiplier (SiPM) array from SensL/onsemi with 6x6 mm 2 SiPMs. The alpha screen of the API deuterium-tritium neutron generator is read out with the S13361-3050AE-08 from Hamamatsu, which is an 8x8 array of 3x3 mm 2 SiPMs. Data from the 320 channel system is acquired with the TOFPET2-based readout system. We present the predicted imaging capability of an eventual 5x5 detector array, the waveform-based energy and pulse shape characterization of the individual detectors, and the timing and energy response from the TOFPET2 system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End of Summer Presentation: What I did over the course of 13 weeks

Outline/Objective - Objective: Determining Young's Module (E) for custom PCBs where properties are unknown or are not analytically possible - E is used in bending and modular frequency calculations; Outline - PCB effective property calculations; FEA and analytical solutions comparisons; Experimental method to determine E

42 ENGINEERING↗

Ultrasound preliminary cyber-physical evaluation

In this assessment, we focused on identifying unwanted RF emissions from the subject devices. This consisted of two major approaches: 1) Monitor for emitted RF during operation and ensure it is within expected bounds. 2) Inspect circuit board construction for any geometry or design patterns that could lead to RF emissions, whether intentional or unintentional. These patterns include: a) Single-ended PCB traces that could operate as an antenna. b) Insufficient shielding around typically “noisy” components such as switching power supplies. c) Free-hanging high-speed signal wires with no shielding that could emit RF. Suspicious components and design patterns were given a plausible reason to be included in the design. Any suspicious components or patterns warranted reason for deeper investigation. After more in-depth analysis no components were found to be intentionally malicious or had unexpected functionality.

42 ENGINEERING↗

Surface Pressure Fluctuations Induced by a Hypersonic Turbulent Boundary Layer on a Sharp Cone at Angle of Attack

High-fidelity simulations are performed to characterize the turbulence-induced wall pressure fluctuations on a sharp cone at a 5.5° angle-of-attack in a Mach 8 flow. Wall-resolved large-eddy simulation (LES) and wall-modeled large-eddy simulation (WMLES) results are compared to measurements at several locations on the cone body, where comparisons with high-frequency PCB sensors are good, while comparison with low-frequency kulite sensors varies depending on the location. For a given streamwise location, simulation results show significant azimuthal variation in the wall pressure fluctuation statistics. Comparisons between LES and WMLES results indicate that WMLES can accurately reproduce the low-frequency component of the autospectra quite well, while slight sensitivity is apparent in the coherence. A grid sensitivity study for WMLES further demonstrated sensitivity in the wall pressure fluctuation coherence, but not in the autospectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of Flex-QA Arrays in HTS Magnet Testing

Flexible PCB quench antennas have been very useful in providing high-quality high-resolution data in low temperature superconducting magnet tests. Similar multi-sensor arrays have been employed recently to cover a high temperature superconductor magnet tested at FNAL. In the present work, data taking conditions and magnet features to support the analysis framework are discussed. Then observations made during complete magnet powering cycles are described and analysis of quench antenna data are presented. Based on results, improvements to instrumentation and data taking are debated. Views on the future of flexible quench antenna sensors for HTS magnet diagnostics and operational support are shared.

Stoynev, S.↗

Enhancements to Lab-on-a-Fish Technology: Final Report for I3T Project 81245

PNNL has engaged in discussions with several organizations regarding potential future collaborations. PNNL has developed the Lab-on-a-Fish prototypes and produced video instructions for an organization conducting research on shark eggs. Several organizations have expressed interest in using the Lab-on-a-Fish for their studies. We’ve also updated two versions of the Lab-on-a-Fish to expand its applications to a wider range of animal studies and accelerate its commercialization. The new design of the Lab-on-a-Fish, which incorporates PCB-based electrodes, has demonstrated the ability to capture clear ECG signals without the need for additional needle-shaped electrodes. This innovation eliminates the need for implanting electrodes beneath the fish's skin at specific locations, which is required with the current version of Lab-on-a-Fish. This change significantly simplifies the manufacturing and implantation process. For the Lab-on-a-Fish design that uses an optical pulse oximeter, the measurement results were primarily influenced by respiratory activity rather than heart rate. This occurred because the oximeter was placed beneath the operculum. Further research and development are needed to explore more suitable locations and methods for accurate pulse oximeter measurements.

59 BASIC BIOLOGICAL SCIENCES↗

2.5D HI Packaging of the Power Converter using TSV interposer.

Abstract: Advantages of the 2.5D HI (Heterogeneous Integration) electronics packaging of the power electronics compared to PCB packaging will be presented. Current 2.5D packaging effort using TSV (Through Silicon Via) will be presented in terms of fabrication, microstructural analysis, reliability, and thermal simulation.

Chung, Hyunim↗

Broadband mm-Wave Substrate Integrated Waveguides [Poster]

At mm-wave frequencies, signals need to be supported by specialized, low-loss transmission lines such as waveguides. Substrate-integrated waveguides (SIWs) combine the good electrical properties of rectangular waveguides with the compactness of planar transmission lines. Additionally, SIWs can be fabricated using standard PCB manufacturing techniques and can be easily integrated with other mm-wave components. This study explores SIWs in the 50-75 GHz range, with designs optimized for simple fabrication.

42 ENGINEERING↗

Booster Cavity Damper Redesign for PIP-II

A new Higher Order Mode (HOM) damper was designed and tested for the Booster accelerator cavity at Fermilab. In anticipation of the PIP-II upgrade, it was discovered that the higher beam intensity of PIP-II may cause beam instability due to an excited mode at 106 MHz. This unfortunately corresponds with the cavity s 2nd order harmonic mode, which will sweep from 86-105.7 MHz. The new damper is a modification of an existing damper that was designed to reduce an existing static HOM at 83 MHz, with the new design intending to cover the 2nd order HOM as well. The existing damper uses an inductive coupling loop to extract RF energy from the cavity which then goes through a filter in order to reflect the fundamental frequency back into the cavity while passing HOMs to a dump load. The new damper intends to replace the filter portion of the system with a wider band variant while also changing the topology from a coaxial cable loop filter to a componentized PCB-based design. Primary design challenges include bandwidth coverage, impedance matching of the various modes, long term thermal and mechanical stability, radiation hardness, and high voltage handling. Initial designs achieved the desired damping but were found to quickly succumb to destructive arcing due to the voltages present. More finalized designs intend to address this problem through circuit design modifications as well as the use of hardier components.

Pieper, Dustin [Fermilab]↗

Quench Propagation On Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, localized losses of superconductivity, known as quenches, pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered onto a printed circuit board (PCB) with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits, but resulted in local burnout. In the second test, a heater-induced quench at 300 A propagated bidirectionally with velocities ranging from 164–226 mm/s. These results provide critical parameters for improving REBCO quench detection and protection system design while accounting for REBCO’s limited bendability.

Ju, Han [Northern Illinois U.]↗

IMPACT 2025-2026 Internship Poster

At Sandia National Laboratories, I developed a C++ program that converts printed circuit boards(PCB) and integrated circuits(IC) design files to be compatible for computed tomography (CT) simulations through Monte Carlo methods.

97 MATHEMATICS AND COMPUTING↗

Quench Propagation on Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, the localized losses of superconductivity called a quench pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, hence complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered on a PCB with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits but resulted in a local burn. In the second test, a heater-induced quench at 300 A propagated bidirectionally with measured velocities ranging from 164–226 mm/s. These measurements provide critical parameters for improving REBCO quench detection and protection system design with accounts for REBCO's limited bendability.

Ju, Han [NIU, DeKalb]↗

Adiabatic Propagation Fixture

Previous simulations have tested HTS magnets with dissipative flux flow regimens for thermal runaway. My goal was to make a system that would be able to take real world data on this for Quench Detection. My poster will show the design for a PCB I made and the test setup for conducting said experiment.

Mercado, E. [NIU, DeKalb]↗

A Multi-Layer Phoswich Radioxenon Detection System, Reporting Period 07/01/07 - 09/30/07

During this quarter, the detector manufacturer (Saint-Gobain) delivered one side of the prototype two-channel phoswich detector (XEPHWICH). Once received, our Digital Pulse Processor (DPP1, 12-bit/100 MHz) was employed to capture and digitally process phoswich pulses from laboratory radioactive sources. Our previous pulse shape discrimination algorithm was modified by utilizing three trapezoidal digital filters. This algorithm provides a two-dimensional plot in which the pulse shapes of interest are classified and then can be well identified. The preliminary experimental results will be presented at the 2007 Informal Xenon Monitoring Workshop. The DPP2 (two-channel, 12-bit/ 250 MHz Digital Pulse Processor) is at the prototyping stage. The analog sections have been designed, prototyped and tested. A 6-layer Printed Circuit Board (PCB) was designed, ordered and delivered. The board components were ordered and are now being assembled and examined for proper functionality. In addition, the related FPGA hardware description code (using VHDL) is under development and simulation. Additionally, our researchers have been studying materials regarding wavelet transforms for incorporation into the project. Wavelet transform is an interesting tool for signal processing; one use for our purpose would be to de-noise the detector signal and to express the signal in a few coefficients for signal compression and increased speed. Light capture efficiency modeling and analysis was performed on the XEPHWICH design. Increased understanding of the modeling software was obtained by the discovery of a bug and successful workaround techniques with the DETECT2000 software. Further modeling and plot generation experience was had by the continued use of CERN's ROOT and GEANT4 software packages. Simulations have been performed to compare the output of points versus planes in light capture efficiency. An additional simulation was made with a runtime that was an order-of-magnitude greater than previous simulations, to confirm convergence of the solutions provided by our software methods. We have initiated our investigation into the radon signature expected in our XEPHWICH system. We intend to utilize this signature to confirm earth movement, in the event of an underground nuclear explosion, by continuously monitoring radon levels and noting increases in radon concentration in conjunction with increased levels of radioxenons. The research group is also designing and constructing a fission chamber to be used for the collection of radioxenon gases following neutron bombardment of HEU in the Oregon State University TRIGA reactor. To this point, we have completed milling the aluminum housing and have modeled fission product nuclide production associated with the fissioning of HEU. Additionally, the students have been busy compiling the appropriate information in preparation for irradiation approvals. Using beta spectra of three initial nuclides collected on the prototype phoswich detector, spectral identification by a preliminary neural network was compared to that of solvers of a linear system of equations. Pre-processing in areas such as smoothing and endpoint identification is also being investigated as a means of improving spectral identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multi-Layer Phoswich Radioxenon Detection System (7th Qtr Report), Reporting Period 10/01/07 - 12/31/07

Description of activities conducted this report period: (1) Electronics Development--To improve the overall performance of the two-channel digital pulse processor (DPP2), the PCB has been redesigned and the new printed board is now under assembly. The system is enhanced with two new fast ADCs from Analog Devices (AD9230-250), each with a sampling rate of 250 MHz and a resolution of 12 bits. The data bus uses a high performance Low Voltage Differential Signaling (LVDS) standard. The offset and gain of each channel are separately controlled digitally by the GUI software. (2) GUI Software Development--A GUI is being developed using the Python programming language. All functions from the preceding MATLAB code have been re-implemented including basic waveform readout, pulse shape discrimination, and plotting of energy spectra. In addition, the GUI can be used to control sampling runs based on the number of pulses captured, either in real or live time. Calibration coefficients and pulse shape discrimination boundaries can be changed on the fly so that the detector may be characterized experimentally. Plots generated by the GUI can be exported as graphic data. At present, the software has only been tested using one channel, pending availability of the new DPP board (DPP2). However, the functions have been written to allow easy expansion to two channels. (3) Light Collection Modeling--The XEPHWICH design has been modeled to determine its light capture efficiency. Research in the 7th quarter includes additional simulations representing significant increase in data resolution, well over an order of magnitude greater than previous simulations. The final data set represents approximately 11 billion visible photons divided equally among 110 thousand data points. A laboratory experiment is being designed and executed to experimentally determine light capture efficiency as a function of position within the scintillators. (4) Radioxenon Fission Source--We have designed and constructed a fission chamber to be used for the collection of radioxenon gases following neutron bombardment of HEU in the Oregon State University TRIGA reactor. The aluminum housing and all vacuum fittings have been assembled, awaiting an HEU transfer from PNNL. Students have worked closely with PNNL and OSU Radiation Safety personnel to facilitate transfer of the HEU. The OSU TRIGA Reactor Operations Committee has approved the experiment. (5) Spectral (beta) Recognition--Spectral identification by a neural network developed in our laboratory was compared to that of solvers of a linear system of equations. Data indicate that our neural network is capable of identifying three beta emission sources ({sup 14}C, {sup 36}Cl, and {sup 99}Tc) simultaneously with reliability to within 3%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗