Search NASA⌕ Search

SEARCH · Search NASA

Results for “WORKING FLUID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Brayton Solar Power Conversion System

This report contains the results of work performed in on Phase 1 and Phase 2 related to the Brayton Solar Power Conversion System project. The SolarCAT (Solar Compressed Air Turbine) is dish-engine module with compressed air energy storage. It generates 200-kWe peak power, employing a 320 sq. meter dish. Designed for multi-MW arrays, the power plant provides utility load-profile shaping as well as efficient solar power conversion. At the discretion of the utility operator, the gas turbine also operates on a wide range of fuels (bio and fossil) to supplement solar power or provide non-solar operation. A brief description of the principal subassemblies follows: • The “engine” is a compact turbo-alternator operating with only air serving as the working fluid, the lubricant, and the coolant. The turbo-alternator has been designed to be maintenance-free for the 20-year (60,000 hour) life. • The solar receiver is a tubular design incorporating mature heat exchanger design practices. ORNL has been instrumental in evaluating materials for this application. • The tracking solar concentrator (Dish) was developed and installed at Southwest Solar Technologies, by private funding. The unit constructed for Phase 2 has a collection area of approximately 320 sq meters. The critical subassemblies of the system have been fabricated and tested in Phase 2 of this program. Each subsystem was purpose-built for this new power generation system. This included a special turbo-alternator system built with air bearings, a very compact recuperator, a hybrid combustor, and a solar receiver fully integrated for installation on the SST dish. The receiver was tested alone on the dish. The extensive testing of the turbomachinery, dish and receiver conducted on this program has overcome common development issues. Furthermore, the team has worked exceptionally hard to prove the performance and cost basis of the system. Reliable subsystems have been checked-out and are ready to be move into the complete engine-dish module in Phase 3. In parallel, several economically-driven component upgrades have been identified which improve efficiency and lower cost. The project was terminated prior at the end of Phase 2, to installing the special purpose recuperated turbo-alternator on the dish.

14 SOLAR ENERGY↗

Uncertainty estimation of bifurcated solutions in the Rayleigh–Bénard problem for advanced nuclear reactors applications

Multiphysics models of nuclear reactors frequently comprise nonlinear systems of equations. The nonlinear nature of these models could lead to solution bifurcations, where a small change in a certain parameter, e.g., the thermophysical properties of the coolant, can lead to a sudden change in the system’s behavior. At the point in parameter space where this happens, called a critical point, the Jacobian matrix of the model’s nonlinear operator becomes singular potentially permitting multiple solutions to coexist. In this paper, we perform uncertainty estimation (UE) in a parameter range that includes bifurcated solutions within the context of Rayleigh–Bénard problem. We perform this analysis assuming uncertain temperature difference, and tilt angle for the iterative solution algorithm with a unit Prandtl number (Pr = 1). Also, we perform this analysis under uncertain thermophysical properties for both FLiBe molten salt and liquid sodium as working fluid. We deploy two approaches to compute statistical moments for the resulting distributions of selected flow-field variables. The first approach is the blind computation of the mean and the standard deviation without any consideration of solution bifurcation, while the second approach utilizes k-means clustering to cluster each branch’s solutions together and compute separate statistical moments for each branch. The statistical distributions are obtained by perturbing the selected parameters about nominal values that correspond to a solution on one of the valid branches, and that solution is used as initial guess for the iterative solution algorithm. We found that perturbation of any parameter when its nominal value is close to its critical point always leads to branch jumping, i.e., the iterations converge to a solution on a branch different from the branch of the initial guess. This produces a statistical ensemble comprised of fundamentally different solutions leading to wrong mean values and uncertainty estimates, whereas clustering provides an efficient way to deal with this type of computation. This work is important for developing Gen IV nuclear systems because many of these systems rely on natural convection for cooling especially in accident conditions.

97 - MATHEMATICS AND COMPUTING↗

CIRCULATING MOVING BED COMBUSTION PROOF OF CONCEPT

Circulating Moving Bed (CMB) combustion technology has its roots in traditional circulating fluidized bed technology and involves a novel method of solid fuel combustion and heat transfer. CMB technology represents a step change in improved performance and cost relative to conventional PC and FBC boilers. The CMB heat exchanger preheats the energy cycle working fluid, steam or air, to the high temperature levels required in systems for advanced power generation. Unique features of the CMB are the reduction of the heat transfer surfaces by about 60% as a result of the enhanced heat transfer rates, flexibility of operation, and about 30% lower cost over existing technology. The CMB Phase I project ran from July 2001 through March 2003. Its objective was to continue development of the CMB technology with a series of proof of concept tests. The tests were conducted at a scale that provided design data for scale up to a demonstration plant. These objectives were met by conducting a series of experiments in ALSTOM Power’s Multi-use Test Facility (MTF). The MTF was modified to operate under CMB conditions of commercial interest. The objective of the tests were to evaluate gas-to-solids heat transfer in the upper furnace, assess agglomeration in the high temperature CMB bubbling bed, and evaluate solids-to-tube heat transfer in the moving bed heat exchanger. The Phase I program results showed that there are still some significant technical uncertainties that needed to be resolved before the technology can be confidently scaled up for a successful demonstration plant design. Work remained in three primary areas: • scale up of gas to solid heat transfer • high temperature finned surface design • the overall requirements of mechanical and process design. The CMB Phase II workscope built upon the results of Phase I and specifically addressed the remaining technical uncertainties. It included a scaled MTF heat transfer test to provide the necessary data to scale up gas-to-solids heat transfer. A stress test rig was built and tested to provide validation data for a stress model needed to support high temperature finned surface design. Additional cold flow model tests and MTF tests were conducted to address mechanical and process design issues. This information was then used to design and cost a commercial CMB design concept. Finally, the MBHE was reconfigured into a slice arrangement and tested for an extended duration at a commercial CFB plant.

42 ENGINEERING↗

Multi-Physics Simulations of Heat Pipe Micro Reactor

System Analysis Module (SAM) is under development at Argonne National Laboratory as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. It utilizes the object-oriented application framework MOOSE to leverage the modern software environment and advanced numerical methods. The capabilities of SAM are being extended to enable the transient modeling, analysis, and design of various advanced nuclear reactor systems. This report presents the development of new capabilities for modeling the heat pipe type reactor systems. The need for power at remote locations away from a reliable electrical grid is an important niche for nuclear energy. Heat pipe-cooled fast-spectrum nuclear reactors are well suited for these applications. The key feature of the heat pipe reactors is the use of heat pipes for heat removal from the reactor core. The heat pipe makes use of the phase change of the working fluid and transports a large amount of heat from the evaporator to the condensation end with very small temperature drops. In contrast to the traditional nuclear reactor system that makes use of pumped loop for extracting the thermal power, the heat pipe reactors make use of hundreds of heat pipes for removing the thermal power (including the decay heat) passively. This could potentially significantly improve the reliability and safety of the reactor systems. The essential part in the analysis of a heat pipe type reactor is the modeling of heat transport inside the heat pipe. The capability of SAM was extended to enable the modeling of the conventional heat pipe. The full suite of non-LWR codes for confirmatory analysis at NRC is known as the Comprehensive Reactor Analysis Bundle (CRAB). It makes use of existing NRC codes, and integrates them with several codes developed through the DOE-NE’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In this report, the heat pipe micro reactor is simulated using three submodules under CRAB. The MAMMOTH module is used to simulate the reactor kinetics behavior of the micro reactor; the SAM module is used to simulate the heat conduction in the reactor core and heat removal through the heat pipe heat exchangers and Reactor Cavity Cooling System (RCCS); and the MOOSE Tensor Mechanics module is used to simulate the thermal expansion of the reactor cores. The different sub-models are coupled together using MOOSE’s MultiApp system and executed using the BlueCrab application. The new capability has been demonstrated by a steady-state operation analysis, a failure of a single central heat pipe transient analysis, and a loss of heat sink transient analysis. The fully coupled model is shown to work well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of High Temperature (>700°C) molten Salt Pump Technology for Gen3 Solar Power Tower Systems

Generation 3 Concentrating Solar Power (CSP) Systems require thermal energy storage that can efficiently receive solar heat and deliver it to a working fluid at temperatures greater than 700°C. For liquid systems, the thermal transfer fluid must be phase stable over large temperature ranges. High temperature molten salts meet this criteria, but are difficult liquids to handle. The high heat and salt content can be very corrosive to several different materials that are wetted by the liquid salt. For power tower collectors, the molten salt must be pumped under high pressure to the top of the collector tower. These pumps have impellers and shafts as part of their rotating elements, and under load, require bearings to control shaft movement while rotating. These high temperature pumps require submerged bearings, and thus bearing materials that can withstand the temperature and molten salt contact over long periods of time. This is essential for keeping pump maintenance costs low, and downtime to a minimum. Long running bearing materials is an enabling technology for integrated liquid systems in Generation 3 CSP Systems. Keeping costs low and systems reliable are critical for the broad adoption of Gen 3 CSP Systems. Hayward Tyler, Inc (HTI) proposed development of journal bearing materials for use in vertical pumps designed for pumping high temperature molten salt on both the hot and cold sides of the solar power tower. To complete this objective, HTI utilized the testing capabilities of Oak Ridge National Laboratory (ORNL) and High Temperature System Design (HTSD). Materials would first be selected for static corrosion testing, then downselected for tribological testing. Successful tribologically tested materials would then be downselected for use in additional test regimes. Ten samples were selected for static corrosion testing. Three passed the static testing regime. Two of these materials were downselected for ball material in tribological testing against three metallic alloys: Sintered Y2O3 Partially Stabilized Zirconia YTZP and Silicon Nitride, Grade 147-31N. HTI also proposed collecting data from a thorough bearing test regime using a test rig designed and built as part of this project, and also a conceptual design for a high temperature molten salt vertical pump. HTI withdrew from the project prior to completion of this work and this report reflects only the work completed prior to withdrawal. The completed work produced two papers, one manuscript submitted for publication, and one paper published in the journal Solar Energy Materials and Solar Cells. The papers are: “Tribological behavior of ceramic-alloy bearing contacts in molten salt lubrication for concentrating solar power” and “Material Selection and Corrosion Studies Of Candidate Bearing Materials For Use In Molten Chloride Salt."

14 SOLAR ENERGY↗

Final Report UCLA-Thermochemical Storage with Anhydrous Ammonia

In ammonia-based thermochemical energy storage (TCES), ammonia is dissociated endothermically as it absorbs solar energy during the daytime. When energy is required, the reverse reaction releases energy to heat a working fluid such as steam, to produce electricity. Ammonia-based TCES has great advantages of simplicity, low cost reactants, and a strong industrial base in the conventional ammonia industry. The concept has been demonstrated over three decades of research at Australian National University, achieving a 24-hour demonstration of a complete system. At the start of this project, three challenges were identified that would have to be addressed to show that the system is technically and economically viable for incorporation into a CSP plant with an advanced, high temperature power block. All three of these challenges have now been addressed: 1. The ammonia synthesis reaction had not, to our knowledge, been carried out at temperatures consistent with modern power blocks (i.e., ~650°C). The technical feasibility of operating a reactor under high-temperature, near-equilibrium conditions was an unknown, and was therefore a technical risk. The project has successfully demonstrated steam heating to 650°C and energy recovery to steam at the 5 kWt level. 2. The ammonia system has a relatively low enthalpy of reaction combined with gas phase reactants. This is not a direct disadvantage since the reactants themselves are low cost. The challenge lies in storing the required volume of reactants cost effectively. Therefore, a second key goal was to show, through techno-economic analysis, that underground storage technologies can be used to store the energy-rich gas at a cost that is consistent with the SunShot cost goal. We have identified two promising technologies for gas storage: storage in salt caverns has an estimated cost of 1(USD)/kWht and storage in drilled shafts could be on the order of 7(USD)/kWht. Together these two options answer the technical challenge associated with storage of gas phase components. 3. While this project is primarily concerned with high-temperature heat recovery and methods to store the gaseous components, it is also important to consider the feasibility of the entire system. Consequently, an additional goal was to perform analysis to show the feasibility of integrating endothermic reactors within a tower receiver. A conceptual design of an ammonia dissociation receiver/reactor has been developed that fits into the same size cylindrical envelope as the molten salt receiver in SAM, and has the same design thermal capacity. The calculated thermal efficiency of this receiver is 94.6%. Thus, this investigation has established the technical feasibility of a surround field tower system using ammonia dissociation. With these challenges addressed, we proceeded to design a full-scale synthesis and heat recovery system. A model was developed and validated by comparison with our experimental data. A parametric study showed, among other things, the importance of using small tube diameters and spacing to enhance heat transfer. Multi-parameter optimization was used to find a design that minimizes the wall material volume. Finally, cost estimation shows that the ammonia system has good prospects of meeting the Sunshot 15(USD)/kWht target: estimated costs of the entire synthesis system for the 220 MWt plant with 6 hours of storage are 13(USD)/kWht using salt cavern storage and 18(USD)/kWht using shaft drilling. Costs per kWht are even lower with more hours of storage. With the established technology of ammonia synthesis as a starting point, the successes of the project have mitigated technical risks associated with high-temperature synthesis reaction, underground storage, and tower receiver design. Estimated costs are less than 15(USD)/kWht with salt cavern storage. It is now possible to map a time line to commercial deployment that is likely to be shorter and less risky than other thermochemical cycles under active investigation. UCLA has filed a patent that protects the new ideas developed during this project. Discussions are ongoing with potential investors with the aim of partnering for further work. As well as immediate improvements and extra work with the existing experimental system, a key goal is to extend it to a small solar-driven project at an early opportunity.

14 SOLAR ENERGY↗

A chemical kinetic mechanism for combustion and flame propagation of CH 2 F 2 /O 2 /N 2 mixtures

Here in this work, we compiled and evaluated rate expressions for reactions relevant to the decomposition and combustion of CH 2 F 2 (difluoromethane, refrigerant R-32) in CH 2 F 2 /O 2 /N 2 flames. The recommended values have been used in premixed flame calculations, reported elsewhere, to model experimentally derived burning velocities determined using a constant volume spherical flame method. In this work, we also provide a detailed description of the reaction pathways for decomposition and combustion of CH 2 F 2 . This work is part of a larger effort at NIST to characterize and predict the flammability of new refrigerant working fluids and their blends for consideration as replacements of current refrigerants with high global warming potentials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MRV Challenge 3: velocity and passive scalar comparison in a 3D turbulent flow

The third iteration of a magnetic resonance velocimetry (MRV) challenge comparison activity consisting of 3D flow measurements for a turbulent flow in a water channel moving past centrally positioned cubic obstacles is reported. In this challenge iteration, MRV measurements are coupled with either temperature or concentration measurements to extend the diagnostic utility. Five research teams from around the world conducted the measurements on a single shared apparatus. The water channel included partial elements along the channel sidewalls that varied in height and precluded easy optical accessibility. In addition to a turbulent mainstream flow, a secondary flow entered the channel between the second and third cubic elements from a square injector hole at the channel bottom wall. The injector jet interacts with the mainstream flow and mixes turbulently as it advects downstream. For the selected flow regime and water solutions used as working fluids, the mixing of the higher temperature or concentration through the secondary flow with the mainstream flow satisfies the same dynamics so that both temperature and concentration fields behave as passive scalars and can be directly compared. The measurements are explained in detail by each participating team, and the results are interpolated onto a common grid and compared using line profiles, contour plots, and isosurfaces.

Benson, Mike [ORNL] (ORCID:000000023210116X)↗

SiC compatibility

SiC is a relatively chemically stable ceramic that has potential use in the extreme environments present in nuclear reactors. Reactions with high temperature steam, He, hydrothermal, molten salts, and liquid metals are some of the possible environments that SiC could be exposed to. While it is very stable in air, aqueous environments and very low oxygen partial pressures can lead to SiC recession. Generally, SiC does not react with the FliNaK or FliBe molten salts, or liquid metals, however contaminants in these working fluids leached from other materials can cause reaction layers to occur. Most of these systems require additional testing under neutron irradiation to determine if there are any combined effects.

Mouche, Peter↗

Corrosion in Other Liquid Metals (Li, PbLi, Hg, Sn, Ga)

A wide range of liquid metals have been considered for application in nuclear fission and fusion reactors. Liquid mercury (Hg) was tested as a coolant and working fluid for nuclear fission reactors and as a neutron source target. Liquid lithium and lead lithium eutectic (Li and PbLi) have been extensively studied for fusion reactor designs including plasma facing components (PFCs). Liquid tin and gallium (Sn and Ga) have recently gained attention as alternative PFCs due to their low vapor pressure and chemical stability. To enable successful application of these less common liquid metals, corrosion compatibility with containment materials needs to be investigated. For this purpose, this article reviews corrosion behavior and structural material compatibility, including ferrous alloys, refractory metals, and ceramics, by liquid Li, PbLi, Sn, Ga, and Hg.

Jun, Jiheon↗

New reactor cavity cooling system having passive safety features using novel shape for HTGRs and VHTRs

A new, highly efficient reactor cavity cooling system (RCCS) with passive safety features without a requirement for electricity and mechanical drive is proposed for high temperature gas cooled reactors (HTGRs) and very high temperature reactors (VHTRs). The RCCS design consists of continuous closed regions; one is an ex-reactor pressure vessel (RPV) region and another is a cooling region having heat transfer area to ambient air assumed at 40 (°C). The RCCS uses a novel shape to efficiently remove the heat released from the RPV with radiation and natural convection. Employing the air as the working fluid and the ambient air as the ultimate heat sink, the new RCCS design strongly reduces the possibility of losing the heat sink for decay heat removal. Therefore, HTGRs and VHTRs adopting the new RCCS design can avoid core melting due to overheating the fuels. The simulation results from a commercial CFD code, STAR-CCM+, show that the temperature distribution of the RCCS is within the temperature limits of the structures, such as the maximum operating temperature of the RPV, 713.15 (K) = 440 (°C), and the heat released from the RPV could be removed safely, even during a loss of coolant accident (LOCA). Finally, when the RCCS can remove 600 (kW) of the rated nominal state even during LOCA, the safety review for building the HTTR could confirm that the temperature distribution of the HTTR is within the temperature limits of the structures to secure structures and fuels after the shutdown because the large heat capacity of the graphite core can absorb heat from the fuel in a short period. Therefore, the capacity of the new RCCS design would be sufficient for decay heat removal.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of a thermosyphon-based thermal valve for controlled high-temperature heat extraction

Conventional concentrated solar power (CSP) is a reliable alternative energy source that uses the sun’s heat to drive a heat engine to produce electrical power. An advantage of CSP is its ability to store thermal energy for use during off-sun hours which is typically done by storing sensible heat in molten salts. Alternatively, thermal energy may be stored as latent heat in a phase-change material (PCM), which stores large quantities of thermal energy in an isothermal process. On-sun, the PCM melts, storing energy. Off-sun, the latent heat is extracted to produce dispatchable electrical power. Here, this paper presents the design of a thermosyphon-based device with sodium working fluid that is able to extract heat from a source as demand requires. A prototype has been designed to transfer 37 kW of thermal energy from a 600°C molten PCM tank to an array of 9% efficient thermoelectric generators (TEGs) to produce 3 kW of usable electrical energy for 5 h. This “thermal valve” design incorporates a funnel to collect condensate and a central shut-off valve to control condensate gravity return to the evaporator. Three circumferential tubes allow vapour transport up to the condenser. Pressure and a thermal resistance models were developed to predict the performance of the thermal valve. The pressure model predicts that the thermal valve will function as designed. The thermal resistance model predicts a 5500× difference in total thermal resistance between “on” and “off” states. The evaporator and condenser walls comprise 96% of the “on” thermal resistance, while the small parasitic heat transfer in the “off” state is primarily (77%) due to radiation losses. Lastly, this simple and effective technology can have a strong impact on the feasibility, scalability, and dispatchability of CSP latent storage. In addition, other industrial and commercial applications can benefit from this thermal valve concept.

14 SOLAR ENERGY↗

Development of a mechanistic model for sliding bubbles growth prediction in subcooled boiling flow

In this paper, a new mechanistic model for predicting the growth of sliding bubbles in subcooled boiling flow has been developed. The basis of this model is the assumption that the fundamental heat transfer mechanisms acting on a stagnant bubble growing at a nucleation site can also be applied to the growth of sliding bubbles. The physical assumptions of the existing bubble growth models were modified to reflect the intrinsic physics associated with the sliding bubble growth. The heat transfer mechanisms considered are microlayer evaporation, evaporation of superheated liquid, and condensation. The present model has been successfully validated against a broad set of subcooled flow boiling data, generated by three separate research groups using different working fluids and different heater surfaces. The model successfully reproduced the sliding bubble growth dependencies on mass flux, wall superheat, and liquid subcooling level as observed in the experiments. Finally, on the other hand, in a few cases where the bubble growth inertia was substantially involved in the sliding bubble growth, the predictive ability was limited.

42 ENGINEERING↗

Process intensification in a spinning disk absorber for absorption heat pumps

Absorption heat pumps are often an efficient machine for recovering of low-grade waste heat to cooling applications. However, they suffer from slow transfer processes and consequently large equipment size. This paper presents an experimental investigation of a novel absorber that utilizes a combination of a spinning disk and manifold-microchannel technology to intensify the absorption process. The rotation of the disk improves solution-side absorption performance, while an adaption of manifold-microchannel technology provides water-side enhancement. The enhanced spinning disk absorber was tested in an experimental setup using aqueous lithium bromide as the working fluid. Experimental results are compared with key performance metrics reported in the existing literature. The overall heat transfer increased by a factor of 4.7, and absorption rate increased by a factor of 4 to 10 folds over those in conventional tube absorbers. The results suggest that the spinning disk reactor could substantially reduce the size of absorber in the absorption machines. Better thermal and mass transfer performance can also enable air cooling with higher heat sink temperature than the one available through cooling towers.

42 ENGINEERING↗

Mass optimization of a supercritical CO 2 Brayton cycle with a direct cooled nuclear reactor for space surface power

A long life, reliable, and compact surface power system will be necessary to achieve future goals in space exploration. This application uniquely requires the system to be optimized with respect to mass because system mass directly drives the space launch cost associated with transporting the system to its desired location. In this study, a supercritical CO 2 Brayton cycle coupled to a direct-cooled nuclear reactor was designed and optimized for mass. Robust models were developed for each Brayton cycle component in order to model the cycle performance. The three most massive components of this cycle are the radiator-based heat rejection system (subsequently referred to as the “radiator”), recuperator, and reactor. Mass correlations for the recuperator and radiator were established through interactions with component experts from industry and national labs. A reactor model was developed to predict the minimum mass reactor that satisfies neutronic and thermal limitations for given cycle conditions. The system optimization explores tradeoffs between the reactor, recuperator, and radiator sizes in order to identify the least massive system that will satisfy the power (40 kWe) and life (10 yr) requirements. To explore the effects of turbine inlet temperature on system mass, three types of microtube and shell recuperator technologies were considered: baseline stainless steel (which is consistent with the industry partner’s current designs), stainless steel with non-heritage tube sizes (which requires further development of manufacturing techniques), and Inconel (which is not a current/legacy design). Both stainless steel designs have a temperature limit of 823 K, which limits the turbine inlet temperature to 900 K. The baseline stainless steel design results in a combined mass of 738 kg. The stainless steel design allowing for non-heritage tube sizes reduces the combined mass to 674 kg (a 9% improvement). The Inconel design leads to an optimal turbine inlet temperature of 1120 K and reduces the combined mass to 391 kg (a 47% improvement). Furthermore, the interesting conclusion from this study include: (1) radiator mass dominates the total mass, and this drives the cycle to relatively high heat rejection temperatures resulting in a compressor inlet state point that is not close to the vapor dome; thus, the typical advantages of an sCO 2 system are not realized, and a working fluid with a higher critical temperature may be more suitable, and (2) neutronic limitations cause the reactor size to be relatively unaffected by the power level.

42 ENGINEERING↗

A microchannel shell-and-tube absorber for ammonia-water absorption

A shell-and-tube absorber with microscale geometric features that yields significant volumetric heat duties is investigated. A vertically-oriented baffled shell-and-tube heat exchanger with a tightly packed tube bundle is designed to serve as the absorber for a 10.5 kW nominal cooling capacity absorption chiller. The heat and mass transfer in this absorber is investigated experimentally at operating conditions spanning a wide range of working fluid and coupling fluid flow rates and ambient temperatures. An experimental facility is fabricated to closely simulate the operating conditions in an absorption refrigeration system. Absorption heat duties in the range of 5-15 kW are measured. In addition to operating the absorber in the baseline co-current flow configuration with premixed inlet, fluid ports are provided to enable operation in counter-current flow, where the dilute solution enters from the top and vapor enters from the bottom. The performance of these two flow configurations is compared. A preliminary heat and mass transfer model is developed to quantify the local temperatures, concentrations, and mass flow rates of the solution and vapor streams along the length of the absorber. The model predictions for total heat duty agree with the experimental results within 10% for almost all the data points, with an AAD of ~3.4%. Finally, the results of this study, along with the modeling framework, can guide further development of highly compact and efficient absorbers absorption systems.

42 ENGINEERING↗

Technoeconomic optimization of superalloy supercritical CO 2 microtube shell-and-tube-heat exchangers

Heat exchangers are critical components of aerospace systems and improve efficiency of operation by providing waste heat recovery. Supercritical CO has emerged as a promising candidate working fluid due to its potential in increasing the power density of heat exchangers. In this paper, a generalized costing model is developed to estimate the capital costs incurred to manufacture microtube shell-and-tube heat exchangers. This model is utilized in conjunction with an accurate and efficient 2D numerical shell-and-tube heat exchanger performance prediction model to conduct optimization studies with two key objectives – minimization of cost and maximization of heat exchanger power density – on supercritical CO microtube heat exchangers utilizing superalloy Haynes 282 as the solid material. A methodology is then demonstrated to optimize these heat exchangers using Particle Swarm Optimization for aerospace applications and highly compact and cost-effective optimal designs with power density around 20 and cost per conductance less than 5 $ ∙ K/W are obtained.

42 ENGINEERING↗

Printed circuit primary heat exchanger for power conversion in heat pipe microreactor applications

Here, in the present study, a model was developed for a recuperated air Brayton cycle for heat pipe microreactors, and the effect of the primary heat exchanger type assessed. An annular flow heat exchanger and a printed circuit heat exchanger (PCHE) were evaluated. A sub-sized diffusion bonded, PCHE test specimen was manufactured and tested with nitrogen as the working fluid to validate and improve the PCHE model. A comparison of the thermal cycle efficiency for the Brayton cycle coupled to a heat pipe microreactor using each of the two primary heat exchangers showed competitive performance for both options, with achievable cycle efficiencies of 34 % and 35 % for the annular and printed circuit heat exchangers, respectively. The impact of heat pipe length and additional reheating stages on cycle efficiency was studied. Increasing the heat pipe condenser length from 0.8 to 2.0 m resulted in an increase in cycle efficiency of 3.5 % and 3.2 % for the annular and printed circuit heat exchangers, respectively. The use of additional reheating stages showed a reduction in cycle efficiency since the heat pipe surface area limits the primary heat exchanger size and effectiveness. These results highlight the importance of the primary heat exchanger on the performance of a heat pipe microreactor. Overall, the cycle model, testing, and heat exchanger model showed the potential for the PCHE to improve the economics of a heat pipe microreactor relative to the annular flow heat exchanger, which also opens the possibility to use different heat transfer fluids such as supercritical CO 2 .

PCHE↗