Trace Compound Analysis in TATB by Liquid Chromatography coupled with Spectroscopic and Spectrometric Detection

Accurate quantitation of 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) is important because of its strategic use as an energetic material. A purity determination is also needed for the proper assessment of performance. A fast and sensitive method has been developed to measure the purity of TATB in polymer-bonded materials. The target material is extracted with DMSO, and the extract is separated on a reversed-phase chromatography column. The column effluent is monitored by diode array detection (DAD) at 354 nm. The characteristic UV-Vis response and retention time identify the individual components when compared to pure compound standards. The chemical structures of compounds with no pure standards available have been determined by high-resolution mass spectrometry (MS) and MS/MS. The major component, TATB, along with 1-chloro-3,5-dinitro-2,4,6-triaminobenzene (T4A) and mono-benzofuroxan (FX1) were quantitated directly from pure compound standards. Several trace concentration components, mono-benzofurazan (F1), 1-bromo-3,5-dinitro-2,4,6-triaminobenzene (Br-T4A), 2,4,6-triamino-1-nitroso-3,5-dinitrobenzene (MN-TATB), 2,4,6-triamino-1-hydroxyl-3,5-dinitrobenzene (HO-TATB), and 2,4,6-triamino-1-nitrile-3,5-dinitrobenzene (Nitrile-TATB) were also detected and structures verified via MS/MS. Approximate concentrations were determined using calibrations from standards of similar structures. Additional trace components were also detected by MS. Contained herein are the results of analyses of TATB-based materials characterized for polymer-bonded formulations compared to different preparations of TATB. The accuracy, details, and process of developing this method are reported here.

36 MATERIALS SCIENCE↗

Atmospheric Transmission Spectroscopy of Hot Jupiter KELT-10b using Synthetic Telluric Correction Software

High-resolution spectroscopic visible data were obtained with the Ultraviolet and Visible Echelle Spectrograph on the Very Large Telescope. Our goal was to analyze the data in an effort to detect the presence of sodium in the atmosphere of hot Jupiter exoplanet KELT-10b, as well as characterize the orbit of the planet via the Rossiter-McLaughlin effect. Eighty spectra were collected during a single transit of KELT-10b. After standard spectroscopic calibration using ESO-Reflex, the synthetic telluric modeling software molecfit was applied to remove terrestrial atmospheric effects, and to refine the wavelength calibration. Sodium is recognized by its characteristic absorption doublet located at 5895.924 and 5889.951 Å, which can be seen in the planet atmosphere transmission spectrum and through excess absorption during the transit. The radial velocity of the host star was analyzed by measuring the average shift of absorption features from spectrum to spectrum. Our results indicate a sodium detection in the planet transmission spectrum with a line contrast of 0.66% and 0.43% ± 0.09% for the sodium DII and DI lines, respectively. Excess absorption measurements agree to within one half combined standard deviation between the planet transmission spectrum (0.143% ± 0.020%, a 7σ detection) and during the time series (0.124% ± 0.034%, a 3.6σ detection) in a band 1.25 Å wide. The wavelength grid corrections provided by molecfit were insufficient to determine radial velocities and measure the Rossiter-McLaughlin effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-D-213-08: Remote Dosimetric Credentialing for Clinical Trials with the Virtual EPID Standard Phantom Audit (VESPA)

Purpose: Report on implementation of a Virtual EPID Standard Phantom Audit (VESPA) for IMRT to support credentialing of facilities for clinical trials. Data is acquired by local facility staff and transferred electronically. Analysis is performed centrally. Methods: VESPA is based on published methods and a clinically established IMRT QA procedure, here extended to multi-vendor equipment. Facilities, provided with web-based comprehensive instructions and CT datasets, create IMRT treatment plans. They deliver the treatments directly to their EPID without phantom or couch in the beam. They also deliver a set of simple calibration fields. Collected EPID images are uploaded electronically. In the analysis, the dose is projected back into a virtual phantom and 3D gamma analysis is performed. 2D dose planes and linear dose profiles can be analysed when needed for clarification. Results: Pilot facilities covering a range of planning and delivery systems have performed data acquisition and upload successfully. Analysis showed agreement comparable to local experience with the method. Advantages of VESPA are (1) fast turnaround mainly driven by the facility’s capability to provide the requested EPID images, (2) the possibility for facilities performing the audit in parallel, as there is no need to wait for a phantom, (3) simple and efficient credentialing for international facilities, (4) a large set of data points, and (5) a reduced impact on resources and environment as there is no need to transport heavy phantoms or audit staff. Limitations of the current implementation of VESPA for trials credentialing are that it does not provide absolute dosimetry, therefore a Level 1 audit still required, and that it relies on correctly delivered open calibration fields, which are used for system calibration. Conclusion: The implemented EPID based IMRT audit system promises to dramatically improve credentialing efficiency for clinical trials and wider applications. VESPA for VMAT will follow soon.

60 APPLIED LIFE SCIENCES↗

Technical Note: Impact on detective quantum efficiency of edge angle determination method by International Electrotechnical Commission methodology for cardiac x-ray image detectors

Purpose: Cardiac x-ray detectors are used to acquire moving images in real-time for angiography and interventional procedures. Detective quantum efficiency (DQE) is not generally measured on these dynamic detectors; the required “for processing” image data and control of x-ray settings have not been accessible. By 2016, USA hospital physicists will have the ability to measure DQE and will likely utilize the International Electrotechnical Commission (IEC) standard for measuring DQE of dynamic x-ray imaging devices. The current IEC standard requires an image of a tilted tungsten edge test object to obtain modulation transfer function (MTF) for DQE calculation. It specifies the range of edge angles to use; however, it does not specify a preferred method to determine this angle for image analysis. The study aimed to answer the question “will my choice in method impact my results?” Four different established edge angle determination methods were compared to investigate the impact on DQE. Methods: Following the IEC standard, edge and flat field images were acquired on a cardiac flat-panel detector to calculate MTF and noise power spectrum, respectively, to determine DQE. Accuracy of the methods in determining the correct angle was ascertained using a simulated edge image with known angulations. Precision of the methods was ascertained using variability of MTF and DQE, calculated via bootstrapping. Results: Three methods provided near equal angles and the same MTF while the fourth, with an angular difference of 6%, had a MTF lower by 3% at 1.5 mm{sup −1} spatial frequency and 8% at 2.5 mm{sup −1}; corresponding DQE differences were 6% at 1.5 mm{sup −1} and 17% at 2.5 mm{sup −1}; differences were greater than standard deviations in the measurements. Conclusions: DQE measurements may vary by a significant amount, depending on the method used to determine the edge angle when following the IEC standard methodology for a cardiac x-ray detector. The most accurate and precise methods are recommended for absolute assessments and reproducible measurements, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surrogate Post-Detonation Urban Debris (SPUD): Standard Reference Materials 4600 and 4601

If a terrorist nuclear explosion were to occur in the United States, high-quality (accurate and precise) legally defensible nuclear forensics measurements will be required to assure the certainty and confidence needed, for conclusions drawn from these data will be coupled with law enforcement and intelligence information for the purposes of attribution and retribution. Standard Reference Materials (SRMs)/Certified Reference Materials (CRMs) establish the traceability, accuracy, and precision of nuclear forensic measurements and provide the ability to benchmark measurement methods essential to meeting the requirements of legal scrutiny. Currently there is a critical shortage of key SRMs/CRMs required for accurate and precise measurements that are fundamental to nuclear measurements supporting pre- and post-detonation nuclear forensics. Supplies either do not exist, are not good enough, are in short supply, and/or are very expensive. The radionuclide measurement techniques and data quality objectives for pre- and post-detonation nuclear forensics are quite different than the applications for which the current suite of available SRMs/CRMs was developed. Specifically, 1) modern mass spectrometry methods have largely replaced traditional activity-based measurement methods for quantifying small quantities of long-lived radionuclides and most trace radionuclide SRMs/CRMs are certified for activity and are thus not adequate for current applications, 2) modern instrumental methods are capable of higher precision than historic measurement techniques, and in some cases exceed the precision of the available SRMs/CRMs, and 3) the quality assurance requirements for pre- and post-detonation nuclear forensics are such that the existing cadre of SRMs/CRMs does not adequately support the needs for method validation. There are numerous governmental stakeholders both within the US (DOE, DoD) and internationally (IAEA, JRC-ITU) whose missions are either directly involved with nuclear forensics measurements or rely on the forensic data obtained to make the exacting policy decisions (DOJ (FBI), DHS, CIA, DIA, DoD) associated with disrupting the production of illicit nuclear materials, interdicted nuclear materials or a nuclear/radiological detonation event. Starting in 2008 the DHS NTNFC, in collaboration with NBL and NIST, took on the production of suitable SRMs/CRMs for the pre-detonation nuclear forensics community. Two CRMs have been released since the start of this effort and two more are slated for completion in 2016. More recently, NIST, as a part of its mission as the US National Metrology Institute (NMI) to deliver standards (providing traceability) and foster homeland security, has launched the first certification campaign of a measurement traceable post nuclear detonation SRM. NIST, in cooperation with partner labs (AFIT (DoD), FBI (DOJ), and NPL) and with support from the FBI, has developed two Surrogate Post-Detonation Urban Debris (SPUD) Standard Reference Materials (SRMs) - SRM 4600 and 4601. These SRMs have been developed to simulate the expected debris mixture from the detonation of an Improvised Nuclear Device (IND) in an urban environment, which is capable of producing fresh fission as well as activation products. The elemental composition of the vitrified debris materials is a composite of minerals and metals characteristic of the concrete and steel, the building materials that would be exposed to a nuclear detonation and whose resulting activation products would be found in rubble samples collected for forensics evidence and attribution. Additionally, because post-detonation samples would also contain short-lived fission products, the debris materials have been doped with Uranium (U). To create the nuclear fission products, samples of the SPUD materials can be placed in a well-characterized nuclear reactor and exposed to a set neutron flux and energy, causing the encased U atoms to split and yield short-lived fission products. Because a known amount of U is added to the SPUD materials it is feasible to determine the concentration of the resulting fission products. The subsequent irradiated SPUD glass would be chemically similar to samples that would be generated in an actual detonation, and thus can serve as a standardized reference material for nuclear forensic post detonation measurements. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Calibrating IR Cameras for In-Situ Temperature Measurement During the Electron Beam Melting Process using Inconel 718 and Ti-Al6-V4

The Department of Energy s (DOE) Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory (ORNL) provides world-leading capabilities in advanced manufacturing (AM) facilities which leverage previous, on-going government investments in materials science research and characterization. MDF contains systems for fabricating components with complex geometries using AM techniques (i.e. 3D-Printing). Various metal alloy printers, for example, use electron beam melting (EBM) systems for creating these components which are otherwise extremely difficult- if not impossible- to machine. ORNL has partnered with manufacturers on improving the final part quality of components and developing new materials for further advancing these devices. One method being used to study (AM) processes in more depth relies on the advanced imaging capabilities at ORNL. High performance mid-wave infrared (IR) cameras are used for in-situ process monitoring and temperature measurements. However, standard factory calibrations are insufficient due to very low transmissions of the leaded glass window required for X-ray absorption. Two techniques for temperature calibrations will be presented and compared. In-situ measurement of emittance will also be discussed. Ample information can be learned from in-situ IR process monitoring of the EBM process. Ultimately, these imaging systems have the potential for routine use for online quality assurance and feedback control.

Electron-Beam Melting↗

Characterization of B255 R183 C-Cell Cobalt-60 Irradiator Pool

Characterization of the Radiation Calibration and Spectroscopy Laboratory (RCS) Co-60 source radiation pool was successfully completed. The characterization was done by performing several measurements of dose rate in the center of the Co-60 source radiation pool and at multiple heights from the bottom of the pool. The measurements were taken between November 2018 through January 2019. Opti-Chromic FWT-70-40M dosimeters were used for this measurement. A 7.3 cm inner diameter stainless steel cylinder (vessel) was used to lower the dosimeters to the bottom of the pool inside the 16 cm dimeter Co-60 source basket. The dose rate was measured at heights of 5.5, 12, 19, and 23 cm from the bottom of the pool. The report “Tour of the Standards and Calibration Laboratory” includes information about the Co-60 source radiation pool. The importance of performing the Co-60 source characterization is to confirm previously reported Co-60 source dose rate measurements and to provide a documented measuring procedure for researchers and others who want to use the Co-60 source to evaluate the effects of radiation on space-based equipment for other applications. The measured dose rate at the abovementioned heights was 0.65, 0.69, 0.53, 0.23 krad/min respectively with the highest coefficient of variation of less than 10%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Compilation of LLNL CUP-2 Data

The CUP-2 uranium ore concentrate (UOC) standard reference material, a powder, was produced at the Blind River uranium refinery of Eldorado Resources Ltd. in Canada in 1986. This material was produced as part of a joint effort by the Canadian Certified Reference Materials Project and the Canadian Uranium Producers Metallurgical Committee to develop a certified reference material for uranium concentration and the concentration of several impurity constituents. This standard was developed to satisfy the requirements of the UOC mining and milling industry, and was characterized with this purpose in mind. To produce CUP-2, approximately 25 kg of UOC derived from the Blind River uranium refinery was blended, homogenized, and assessed for homogeneity by X-ray fluorescence (XRF) analysis. The homogenized material was then packaged into bottles, containing 50 g of material each, and distributed for analysis to laboratories in 1986. The CUP-2 UOC standard was characterized by an interlaboratory analysis program involving eight member laboratories, six commercial laboratories, and three additional volunteer laboratories. Each laboratory provided five replicate results on up to 17 analytes, including total uranium concentration, and moisture content. The selection of analytical technique was left to each participating laboratory. Uranium was reported on an “as-received” basis; all other analytes (besides moisture content) were reported on a “dry-weight” basis. A bottle of 25g of CUP-2 UOC standard as described above was purchased by LLNL and characterized by the LLNL Nuclear Forensics Group. Non-destructive and destructive analytical techniques were applied to the UOC sample. Information obtained from short-term techniques such as photography, gamma spectrometry, and scanning electron microscopy were used to guide the performance of longer-term techniques such as ICP-MS. Some techniques, such as XRF and ICP-MS, provided complementary types of data. The results indicate that the CUP-2 standard has a natural isotopic ratio, and does not appear to have been isotopically enriched or depleted in any way, and was not contaminated by a source of uranium with a non-natural isotopic composition. Furthermore, the lack of 233 U and 236 U above the instrumental detection limit indicates that this sample was not exposed to a neutron flux, which would have generated one or both of these isotopes in measurable concentrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and implementation of the NASA Metrology and Information System

The NASA Metrology Information System (NMIS) was developed as a subsystem of the NASA Equipment Management System (NEMS) to provide a standardized technique in managing the calibration programs of its field Centers and facilities. The NMIS is a computerized data-base system providing: automatic instrument calibration recall and control, historical data including calibration and repair labor and parts costs, incoming instrument performance condition; instrument data including description, manufacturer, model and serial number, and instrument user name location. NMIS automatically provides 28 standardized calibration system performance reports on a user selected schedule. An ad hoc report generation capability is also provided. A standardized form, the Metrology Control Document, was developed for use as a calibration work order and data input document. System implementation plan is presented.

German, Earl S.↗

Neutron Sources for Standard-Based Testing

The DHS TC Standards and the consensus ANSI Standards use 252 Cf as the neutron source for performance testing because its energy spectrum is similar to the 235 U and 239 Pu fission sources used in nuclear weapons. An emission rate of 20,000 ± 20% neutrons per second is used for testing of the radiological requirements both in the ANSI standards and the TCS. Determination of the accurate neutron emission rate of the test source is important for maintaining consistency and agreement between testing results obtained at different testing facilities. Several characteristics in the manufacture and the decay of the source need to be understood and accounted for in order to make an accurate measurement of the performance of the neutron detection instrument. Additionally, neutron response characteristics of the particular instrument need to be known and taken into account as well as neutron scattering in the testing environment.

07 ISOTOPE AND RADIATION SOURCES↗

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sample registration software for process automation in the Neutron Activation Analysis (NAA) Facility in Malaysia nuclear agency

Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on ‘Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)’. The objective of the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-P-29: Testing Display Monitors for GSDF Compliance - a Practical Approach

Purpose: To develop a simple technique for testing display monitors for compliance with the DICOM Grayscale Standard Display Function (GSDF), in accordance with the recommendations of AAPM Task Group 18. Methods: We have developed a spreadsheet that can be used to compare both the luminance response and contrast response of a display to the GSDF, using luminance measurements of the SMPTE test pattern. The contrast response compares the slope of the GSDF j-index as a function of pixel value to that of the GSDF function, and should lie within the range 0.85 to 1.15. Results: We present the results of measurements both of primary diagnostic displays and of ultrasound and acquisition workstations, all at a tertiary care hospital. The Barco displays in the radiographic reading rooms are GSDF compliant or nearly so, while those in the ultrasound reading rooms and at the acquisition workstations generally show significantly higher contrast at low luminance levels than they would if GSDF compliant, and lower contrast at high luminance levels. Conclusion: The spreadsheet that we developed allows a simple comparison of measured display contrast response to the GSDF. Although we used the SMPTE pattern, the same technique could be used with other grayscale patterns, such as TG18-QC and TG18-PQC.

07 ISOTOPE AND RADIATION SOURCES↗

Use of XRF to characterize pre-Hanford orchards in the 100-OL-1 operable unit - 15717

Prior to 1943, Hanford site included several small towns with approximately 5,000 acres of orchards; at the time lead arsenate (PbHAsO{sub 4}) was the most commonly used pesticide. High concentration of lead and arsenic have been recorded where trees and stumps are still visible. Pre-Hanford orchards have been designated as 100-OL-1 Operable Unit. An Optimization study evaluated optimal counting time and position of the XRF from soils collected at the site. A Pilot Study included the evaluation of a field portable x-ray fluorescence (XRF) analyzer determining if performance results meet quality assurance criteria for cleanup. XRF has only previously been used as a screening tool. Four Decision Units (DUs) are to be analyzed: Ol-14. OL-32. OL-IU6-4 and OL-FR2-1. The DUs vary in size and have had distinct historic activities; such as 46.4 acres OL-14 having a military camp in the 1950's unlike OL-FR2-1 having been disturbed as it is near the F area reactor. Together the DUs provide an adequate representation of the Operable Unit. Screening criteria for lead (250 mg/kg) and arsenic (20 mg/kg). Six samples were collected ranging above, at, and below the screening criteria of 250 mg/kg for Pb and 20 mg/kg for As at the Decision Units OL-14 and OL-IU6-4, and labeled respectively. Samples were hand sieved, homogenized and placed in sample cups. Three replicates were prepared for each sample. Each sample cup was analyzed 3 times for 30 sec. A Standard Reference Material (SRM) was analyzed after every 20 readings. Three samples were selected for 15, 30, 45, 60, 90, 120, 150 and 180 second fixed and variable analysis. Two transects at OL-14, and one at OL-IU6-4 were created by selecting locations 90. around ground zero at distances of 0.5, 1, 2, 4, 8 and 12 feet (16 ft for OL-14). Locations were scanned in triplicate for 60 seconds each. 4 Decision Units spanning roughly 370 acres were chosen to represent 100-OL-1 Operable Unit. 40 locations within each DU were selected using Visual Sample Plan (VSP) with a random start and systematic grid pattern. Each location would be analyzed with 3 replicates and a 60 second count time. The Standard Reference Material (SRM) and blank are analyzed after every 20 counts to ensure accuracy. Data is extracted from XRF to be implemented in GIS for visual representation of site with 1943 and 2013 aerial imagery. Discussion/Conclusion: - XRF provided a good indication of precision and accuracy relative to ICP with a linear correlation R{sup 2} value higher than anticipated at .9735; - MDL proved the detection limit is significantly lower than the screening criteria; - When comparing results from the first 40 locations of OL-14 to the total 80 locations of OL-14, the same variability was seen; - We expect high concentrations of Pb and As to be where past orchards are present though this does not occur as all sites. Significance: - XRF is competent for decision making as values fall within ±20% ICP data; - The highest concentrations are not where expected, which may be an issue for sites outside of Hanford that have had more development; - The size of the DU does not affect the number of samples measured. Future Work: - Verification and validation of the XRF Data (QA/QC); - Revise conceptual site model; - Statistical evaluations to investigate: Estimation of variability in surface soils, appropriate size for DU, and sample size per DU; - Coordinating sample results through CORE; - Displaying sample results in PHOENIX (GIS tool)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-BRD-15: Quality Correction Factors in Scanned Or Broad Proton Therapy Beams Are Indistinguishable

Purpose: The IAEA TRS-398 code of practice details the reference conditions for reference dosimetry of proton beams using ionization chambers and the required beam quality correction factors (kQ). Pencil beam scanning (PBS) requires multiple spots to reproduce the reference conditions. The objective is to demonstrate, using Monte Carlo (MC) calculations, that kQ factors for broad beams can be used for scanned beams under the same reference conditions with no significant additional uncertainty. We consider hereafter the general Alfonso formalism (Alfonso et al, 2008) for non-standard beam. Methods: To approach the reference conditions and the associated dose distributions, PBS must combine many pencil beams with range modulation and shaping techniques different than those used in passive systems (broad beams). This might lead to a different energy spectrum at the measurement point. In order to evaluate the impact of these differences on kQ factors, ion chamber responses are computed with MC (Geant4 9.6) in a dedicated scanned pencil beam (Q-pcsr) producing a 10×10cm2 composite field with a flat dose distribution from 10 to 16 cm depth. Ion chamber responses are also computed by MC in a broad beam with quality Q-ds (double scattering). The dose distribution of Q -pcsr matches the dose distribution of Q-ds. k-(Q-pcsr,Q-ds) is computed for a 2×2×0.2cm{sup 3} idealized air cavity and a realistic plane-parallel ion chamber (IC). Results: Under reference conditions, quality correction factors for a scanned composite field versus a broad beam are the same for air cavity dose response, k-(Q-pcsr,Q-ds) =1.001±0.001 and for a Roos IC, k-(Q-pcsr,Q-ds) =0.999±0.005. Conclusion: Quality correction factors for ion chamber response in scanned and broad proton therapy beams are identical under reference conditions within the calculation uncertainties. The results indicate that quality correction factors published in IAEA TRS-398 can be used for scanned beams in the SOBP of a high-energy proton beam. Jefferson Sorriaux is financed by the Walloon Region under the convention 1217662. Jefferson Sorriaux is sponsored by a public-private partnership IBA - Walloon Region.

60 APPLIED LIFE SCIENCES↗

Combined Effort to De-Inventory the New Brunswick Laboratory of Plutonium Certified Reference Materials - 20504

To de-inventory plutonium Certified Reference Materials standards (CRMs) from the New Brunswick National Laboratory (NBL), the Argonne National Laboratory (ANL) and Savannah River National Laboratory (SRNL) formed a unique team. This teaming arrangement leveraged the different capabilities and expertise of both laboratories, helping to ensure the effort would be performed both safely and cost-effectively. With the NBL then physically housed on the ANL site, ANL served as the host-site, providing the necessary facilities and support services (e.g., supplying everything from hoods, loading equipment, and scales to Health Physics supports). From a packaging perspective, ANL's responsibilities focused mainly on characterizing and preparing the contents for shipment, followed by performing the Shipper of Record activities. With SRNL being the Package Design Authority of the 9978, the Type B packaging used for this effort, SRNL's scope included developing a Safety Analysis Report in Packaging (SARP) Letter Amendment to add the CRMs as authorized contents to the 9978. Recognizing competency, ANL prodigiously tasked SRNL to perform the actual loading of the CRMs into the 9978s, while physically on the ANL site. This paper details five different aspects of this effort. They are: 1. Characterization/validation of the CRM contents. 2. Development of the 9978 SARP Letter Amendment for the content change. 3. Development of the nitrogen inerting method to address SARP identified potential flammability concerns. 4. Renewal of the SRNL 9978 loading procedure. 5. Performance of the actual work execution activities. In 2017, the first nine packages were successfully loaded and shipped from NBL, while in 2019, the last ten were successfully loaded and planned for shipment. Without ANL leveraging SRNL's strengths, the de-inventorying of NBL of its plutonium CRMs would have likely taken many years longer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Size Exclusion Chromatography-Ion Mobility-Mass Spectrometry Coupling: a Step Toward Structural Biology

Noncovalent interactions are essential for the structural organization of biomacromolecules in cells. For this reason, the study of the biophysical, dynamic, and architectural interactions among biomacromolecules is essential. Since mass spectrometry requires compatible solutions while preserving the noncovalent bonding network, we envisioned that size exclusion chromatography coupled with ion mobility and mass spectrometry would be a valuable technique to desalt the initial sample and provide solution and gas-phase structural information in a single stage experiment. Such coupling allowed obtaining information on solution protein complex composition with SEC separation and on authenticity and purity with IMS-MS. Our study demonstrated that such coupling is compatible, useful, as well as suitable for a routine analysis, in pharmaceutical industry, for example. Mobility data were reliable and injected standards allowed calibrating the collision cross-section scale. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗