Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Elemental analysis of cotton by laser-induced breakdown spectroscopy

Laser-induced breakdown spectroscopy (LIBS) has been applied to the elemental characterization of unprocessed cotton. This research is important in forensic and fraud detection applications to establish an elemental fingerprint of U.S. cotton by region, which can be used to determine the source of the cotton. To the best of our knowledge, this is the first report of a LIBS method for the elemental analysis of cotton. The experimental setup consists of a Nd:YAG laser that operates at the fundamental wavelength as the LIBS excitation source and an echelle spectrometer equipped with an intensified CCD camera. The relative concentrations of elements Al, Ba, Ca, Cr, Cu, Fe, Mg, and Sr from both nutrients and environmental contributions were determined by LIBS. Principal component analysis was used to visualize the differences between cotton samples based on the elemental composition by region in the U.S. Linear discriminant analysis of the LIBS data resulted in the correct classification of >97% of the cotton samples by U.S. region and >81% correct classification by state of origin.

74 ATOMIC AND MOLECULAR PHYSICS↗

Detection of chlorine with concentration of 0.18 kg/m{sup 3} in concrete by laser-induced breakdown spectroscopy

The chlorine concentration in concrete samples was measured by laser-induced breakdown spectroscopy (LIBS). One or two pulsed second harmonic Nd:YAG lasers ({lambda}=532 nm) were used for the generation of laser-induced breakdown, and an intensified CCD camera, spectrometer, and optical bundle fiber were used for spectral measurement. To maximize the spectral intensity of the chlorine fluorescence line at a wavelength of 837.59 nm, the time delay between laser irradiation and spectral measurement, the time delay between the two laser pulses in double-pulse measurement, and the gate width of the spectral measurement were optimized. The linear relationship between the spectral intensity of the chlorine fluorescence line and the chlorine concentration was verified for pressed samples with chlorine concentrations from 0.18 to 5.4 kg/m{sup 3}. The signal-to-noise ratio was higher than 2 for the sample with a chlorine concentration of 0.18 kg/m{sup 3} (0.008 wt. %). Thus, a chlorine concentration of 0.6 kg/m{sup 3}, at which the reinforcing bars in concrete structures start to corrode, can be detected. These results show that LIBS is effective for the quantitative measurement of chlorine concentration in concrete with high sensitivity.

74 ATOMIC AND MOLECULAR PHYSICS↗

Reconstruction dynamics of recorded holograms in photochromic glass

We have investigated the dynamics of the record-erase process of holograms in photochromic glass using continuum Nd:YVO{sub 4} laser radiation ({lambda}=532 nm). A bidimensional microgrid pattern was formed and visualized in photochromic glass, and its diffraction efficiency decay versus time (during reconstruction step) gave us information (D, {Delta}n) about the diffusion process inside the material. The recording and reconstruction processes were carried out in an off-axis setup, and the images of the reconstructed object were recorded by a CCD camera. Measurements realized on reconstructed object images using holograms recorded at a different incident power laser have shown a two-stage process involved in silver atom kinetics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nitrogen thermometry in an inductively coupled plasma torch using broadband nanosecond coherent anti-Stokes Raman scattering

The development of atmospheric hypersonic flight and re-entry capabilities requires the characterization of the thermo-chemical state of representative test environments. This study demonstrates the usage of multiplex nanosecond N 2 coherent anti-Stokes Raman scattering (CARS) to measure temperatures in an atmospheric, high-temperature (>6000K), air plasma plume, generated by an inductively coupled plasma torch. These are some of the highest temperatures ever accessed via gas-phase CARS, to our knowledge. Temperatures of N 2 in the equilibrium plasma plume are determined via theoretical fits to measured CARS spectra. We discuss the practical implementation of CARS at very high temperatures, including the scaling of the N 2 CARS signal strength from 300 to 6700 K, where the expected peak signal from the high-temperature plasma torch gases is two orders of magnitude less than commonly encountered in combustion environments. An intensified CCD camera enables single-laser-shot detection at temperatures as high as 6200 K, by increasing sensitivity and providing a time gate against intense background luminosity. We also discuss the impacts of unwanted two-beam CARS contributions from outside the nominal three-beam measurement volume. We present mean axial and radial temperature profiles, as well as time-series data derived from both single-laser-shot and accumulated CARS spectra. The single-laser-shot precision is 1.7%–2.6% at temperatures of 3500 to 6200 K. The presented results pave the way for the use of CARS at very high temperatures and the measurement of spatially resolved interface processes in high-enthalpy flows.

Fries, Dan (ORCID:0000000229513294)↗

Low Distortion Lens Design for Large Scintillators

Tomographic imaging of large objects from an x-ray source require a 240 mm square scintillator that is imaged onto a 90 mm square charge-coupled device (CCD) with <0.01% distortion. A large pellicle and internal folding mirror keep the optical elements and the CCD camera out of the x-ray beam path to minimize shielding requirements. Better imaging is needed for 2-D digital radiography and computer tomography (3-D) on the Los Alamos National Laboratory’s Microtron x-ray–generating source, a bremsstrahlung source with endpoint energies of 6, 10, 15, and 20 MeV. Large objects are placed into the x-ray beam and rotated between radiographs. X-rays are deposited into scintillators that are viewed with digital cameras. Better light gathering is needed because the scintillators emit low levels of light. Earlier imaging techniques used film in contact with the scintillator. Our design goal is to match the resolution of the digital camera system to that of the film. 3-D tomography requires extremely low distortion of the collected images.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed particle analysis using forward and backward two-dimensional angular optical scattering

Measurement of two-dimensional angle-resolved optical scattering (TAOS) patterns is an attractive technique for detecting and characterizing micron-sized high-speed flying particles. The elastic-scattering intensity pattern from a single particle as a function of spherical coordinate angles θ and ϕ provides detailed information on the particle’s morphology. By use of an ellipsoidal reflector and a high-speed CCD camera, scattering from a CW-laser was detected and resolved over a large angular range (θ from 12° to 168° and ϕ from 0° to 360°) from spherically shaped particles (e.g., amorphous silica and borosilicate glass) flowing through the reflector’s focal plane at speeds of 20 to 30 m/s. The scattering pattern from individual particles flying through the focal plane of the ellipsoid mirror provides insights about a particle’s size, clustering, roughness, and velocity.

Optics and optical instruments↗

UT-NE Radiation Instrumentation Research Group Meeting: An Update on Progress

The purpose of this project is to design a system to image large and/or thick objects with high dynamic ranges using an intensified, charge coupled device (CCD) camera and a fast-pulsed, high energy neutron source; Improve image resolution by reducing scatter; and Design ultra-fast scintillator using nanotechnology to allow for better timing (and thus better scatter rejection).

07 ISOTOPE AND RADIATION SOURCES↗

New Software Architecture Options for the TCL Data Acquisition System

The Turbulent Combustion Laboratory (TCL) conducts research on combustion in turbulent flow environments. To conduct this research, the TCL utilizes several pulse lasers, a traversable wind tunnel, flow controllers, scientific grade CCD cameras, and numerous other components. Responsible for managing these different data-acquiring instruments and data processing components is the Data Acquisition (DAQ) software. However, the current system is constrained to running through VXI hardware—an instrument-computer interface—that is several years old, requiring the use of an outdated version of the visual programming language, LabVIEW. A new Acquisition System is being programmed which will borrow heavily from either a programming model known as the Current Value Table (CVT) System or another model known as the Server-Client System. The CVT System model is in essence, a giant spread sheet from which data or commands may be retrieved or written to, and the Server-Client System is based on network connections between a server and a client, very much like the Server-Client model of the Internet. Currently, the bare elements of a CVT DAQ Software have been implemented, consisting of client programs in addition to a server program that the CVT will run on. This system is being rigorously tested to evaluate the merits of pursuing the CVT System model and to uncover any potential flaws which may result in further implementation. If the CVT System is chosen, which is likely, then future work will consist of build up the system until enough client programs have been created to run the individual components of the lab. The advantages of such a System will be flexibility, portability, and polymorphism. Additionally, the new DAQ software will allow the Lab to replace the VXI with a newer instrument interface—the PXI—and take advantage of the capabilities of current and future versions of LabVIEW.

97 MATHEMATICS AND COMPUTING↗

Flexibility and utility of pre-processing methods in converting STXM setups for ptychography (Final Paper)

Ptychography is an advanced diffraction based imaging technique that can achieve resolution of 5nm and below. It is done by scanning a sample through a beam of focused x-rays using discrete yet overlapping scan steps. Scattering data is collected on a CCD camera, and the phase of the scattered light is reconstructed with sophisticated iterative algorithms. Because the experimental setup is similar, ptychography setups can be created by retrofitting existing STXM beam lines with new hardware. The other challenge comes in the reconstruction of the collected scattering images. Scattering data must be adjusted and packaged with experimental parameters to calibrate the reconstruction software. The necessary pre-processing of data prior to reconstruction is unique to each beamline setup, and even the optical alignments used on that particular day. Pre-processing software must be developed to be flexible and efficient in order to allow experiments appropriate control and freedom in the analysis of their hard-won data. This paper will describe the implementation of pre-processing software which successfully connects data collection steps to reconstruction steps, letting the user accomplish accurate and reliable ptychography.

43 PARTICLE ACCELERATORS↗

Ptychography: Pushing the Limits of X-Ray Microscopy

Ptychography is an advanced diffraction based imaging technique that can achieve resolution of 5 nm, and below. It is done by scanning a sample through a beam of focused x-rays using discrete yet overlapping scan steps. Scattering data is collected on a CCD camera, and the phase of the scattered light is reconstructed with sophisticated iterative algorithms. Because the experimental setup is similar, ptychography setups can be created by retrofitting existing STXM beam lines with new hardware. The other challenge comes in the reconstruction of the collected scattering images. Scattering data must be adjusted and packaged with experimental parameters to calibrate the reconstruction software. The necessary pre-processing of data prior to reconstruction is unique to each beamline setup, and even the optical alignments used on that particular day. Pre-processing software must be developed to be flexible and efficient in order to allow experimenters appropriate control and freedom in the analysis of their hard-won data. This paper will describe the implementation of pre-processing software which successfully connects data collection steps to reconstruction steps, letting the user accomplish accurate and reliable ptychography.

47 OTHER INSTRUMENTATION↗

Laser System for Biological Tissues Final Report CRADA No. TSB-1549-98

The goal of this project was to demonstrate a laser-based system which can shape and resurface the epidermal plate as well as generate images on acrylic. The prototype system used a pulsed diode pumped laser to ablate and shape the surface using a high absorption pigment. A CCD camera will image the epidermal plate and computer software will analyze the image to guide laser ablation. . The deliverable was for LLNL to generate a final report upon completion of the project, which summarized the results of the project and the schematics for the prototype device. This project consisted of six (6) main tasks, all of which would be performed at LLNL over a seven (7) month period. Due to lack of manpower availability which caused delays in the project work, and minor redesigns which delayed manufacturing, the project was extended for an additional five months.

47 OTHER INSTRUMENTATION↗

Beam Meassurements Using Visible Synchrotron Light at NSLSII Storage Ring

Visible Synchrotron Light Monitor (SLM) diagnostic beamline has been designed and constructed at NSLS2 storage ring, to characterize the electron beam profile at various machine conditions. Thanks for the excellent alignment, SLM beamline was able to see the first visible light when beam was circulating the ring for the first turn. The beamline has been commissioned for the past year. Besides a normal CCD camera to monitor the beam profile, streak camera and gated camera are used to measure the longitudinal and transverse profile to understand the beam dynamics. Measurement results from these cameras will be present in this paper. A time correlated single photon counting system (TCSPC) has been setup and measures the single bunch purity using visible light, preliminary TCSPC measurement result will be presented as well.

36 MATERIALS SCIENCE↗

Validation of the HyRAM+ physics models for use with propane

The Hydrogen Risk Assessment Model Plus (HyRAM+) toolkit combines quantitative risk assessment with simulations of unignited dispersion, ignited turbulent diffusion flames, and indoor accumulation with delayed ignition of fuels. HyRAM+ is differentiated from HyRAM in that it includes models and leak data for other alternate fuels. The models of the physical phenomena need to be validated for each of the fuels in the toolkit. This report shows the validation for propane which is being used as a surrogate for autogas, which is a mixture of propane and butane and used in internal combustion engines in vehicles. For flame length comparisons, five previously published experiments from peer reviewed journals were used to validate our models. The validation looked at flame lengths and flame widths with respect to different leak diameters, mass flow rates, and source pressures. Most of the sources included more than one set of experimental data, which were collected using different methods (CCD cameras, IR visualization etc.). In general, HyRAM+ overpredicts the flame lengths by around 65%. For heat and radiation models, we compared the heat flux and radiation data reported from two different sources to the values calculated by HyRAM+. For higher mass flow rates, the HyRAM+ calculated flame length results gave a better estimate of what is found in the experiments (65% error), but a higher error (85%) is observed between the HyRAM+ calculated lengths and the experimental flame lengthsfor lower mass flows. Some differences can be attributed to outdoor environmental effects (i.e. wind speed) and uncertainties in jet flame shapes. The propane flame trajectory is predicted for a high Reynolds number case with Re = 12,500 and a low Reynolds number case where Re = 2,000. The Re=12,500 case which is momentum dominated matches well with the experimental flame trajectory, but the agreement for the bouancy driven low Reynolds number case is not as good. Dispersion modeling for unignited propane was also analyzed. We compared the mole fraction, mixture fraction, mean velocity, concentration half width, and inverse mass concentration over an axial distance from different credible journals to the values calculated by HyRAM+. The results display good agreement but generally, HyRAM+ predicts a wider profile for mole fraction and mixture fraction experiments. Overall, HyRAM+’s results are reasonable for predicting the flame length, heat flux, flame trajectory, and dispersion for propane and can be used in risk analyses

08 HYDROGEN↗

NSUF Report EBSD analyses on metallic fuel samples: Tips and improvements in sample preparation

EBSD (Electron Backscatter Diffraction) is an analytic technique used to evaluate the microstructure of a specimen. It can be used to evaluate interesting crystallographic data ranging from grains size to grain orientation, from grain boundaries to stresses. Moreover, in the field of nuclear materials EBSD can aid in estimating properties important for reactor performance, such as dislocation and residual strain [1]. EBSD patterns are generated by focusing a stationary electron gun on the specimen and detecting the backscatter electrons that satisfy Bragg conditions, and thus are diffracted by the crystal planes forming the so called Kikuchi bands. These bands correspond to each of the lattice diffracting crystal planes and are detected on a phosphor screen via a low-light CCD camera [2]. The patterns are generated within a small interaction volume located at a depth of less than 50-100 nm. Because of this, the data quality is extremely sensitive to the integrity of the crystallographic lattice order at the surface of the sample and thus to sample preparation and to oxidation [3]. While conventional sample preparation methods are widely used in materials science, they often do not lead to quality electron backscatter patterns needed for the characterization of nuclear materials [4]. This has been related by many authors to the challenges associated with handling radiological specimens, their rapid oxidation, and artifacts in such samples (e.g. high number of defects, precipitates and/or porosities) [4-8]. EBSD, however, can be an invaluable technique to evaluate microstructural evolution during fabrication and after irradiation at the required mesoscale for model and simulation. It also provides important information on grain structure necessary to understand irradiation effect, such as grain subdivision. Thus, it is of paramount importance to further the application of this technique to nuclear materials and especially irradiated fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

X-ray Conversion Efficiencies for Diffraction Experiments on Z

We have used a deep-depletion CCD camera in single-hit mode to measure X-ray conversion efficiencies with Z-Beamlet and Z-Petawatt. Z-Petawatt is superior to Z-Beamlet for X-rays harder than 10 keV. For diffraction samples with Z > 42, we likely require X-rays with 15 keV or higher photon energy (Z-Petawatt). We are developing a robust, reproducible setup for X-ray polycapillaries as a part for X-ray diffraction experiments (XRD).

Geissel, Matthias↗

Electro-optic Laser-Sampled Neutron Detector

A new method of detecting radiation which can allow for long distance measurements is being investigated. The device is primarily for neutrons detection althought it could, in principle, be used for gamma ray detection. The neutron detection medium is a solid, transparent, electro-optical material, such as lithium niobate, lithium tantalite, or barium borate. Crystals of these materials act as optical gates to laser light, allowing light to pass through only when a neutron interaction occurs in the crystal. Typical light detection devices, such as CCD cameras or photomultiplier tubes, can be used to signal when light passes through the crystal. The overall goal of the project is to investigate the feasibility of such devices for the detection of neutron radiation and to quantify their capabilities and limitations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HEP Science Network Requirements--Final Report

The Energy Sciences Network (ESnet) is the primary provider of network connectivity for the US Department of Energy Office of Science, the single largest supporter of basic research in the physical sciences in the United States. In support of the Office of Science programs, ESnet regularly updates and refreshes its understanding of the networking requirements of the instruments, facilities, scientists, and science programs that it serves. This focus has helped ESnet to be a highly successful enabler of scientific discovery for over 20 years. In August 2009 ESnet and the Office of High Energy Physics (HEP), of the DOE Office of Science, organized a workshop to characterize the networking requirements of the programs funded by HEP. The International HEP community has been a leader in data intensive science from the beginning. HEP data sets have historically been the largest of all scientific data sets, and the communty of interest the most distributed. The HEP community was also the first to embrace Grid technologies. The requirements identified at the workshop are summarized below, and described in more detail in the case studies and the Findings section: (1) There will be more LHC Tier-3 sites than orginally thought, and likely more Tier-2 to Tier-2 traffic than was envisioned. It it not yet known what the impact of this will be on ESnet, but we will need to keep an eye on this traffic. (2) The LHC Tier-1 sites (BNL and FNAL) predict the need for 40-50 Gbps of data movement capacity in 2-5 years, and 100-200 Gbps in 5-10 years for HEP program related traffic. Other key HEP sites include LHC Tier-2 and Tier-3 sites, many of which are located at universities. To support the LHC, ESnet must continue its collaborations with university and international networks. (3) While in all cases the deployed 'raw' network bandwidth must exceed the user requirements in order to meet the data transfer and reliability requirements, network engineering for trans-Atlantic connectivity is more complex than network engineering for intra-US connectivity. This is because transoceanic circuits have lower reliability and longer repair times when compared with land-based circuits. Therefore, trans-Atlantic connectivity requires greater deployed bandwidth and diversity to ensure reliability and service continuity of the user-level required data transfer rates. (4) Trans-Atlantic traffic load and patterns must be monitored, and projections adjusted if necessary. There is currently a shutdown planned for the LHC in 2012 that may affect projections of trans-Atlantic bandwidth requirements. (5) There is a significant need for network tuning and troubleshooting during the establishment of new LHC Tier-2 and Tier-3 facilities. ESnet will work with the HEP community to help new sites effectively use the network. (6) SLAC is building the CCD camera for the LSST. This project will require significant bandwidth (up to 30Gbps) to NCSA over the next few years. (7) The accelerator modeling program at SLAC could require the movement of 1PB simulation data sets from the Leadership Computing Facilities at Argonne and Oak Ridge to SLAC. The data sets would need to be moved overnight, and moving 1PB in eight hours requires more than 300Gbps of throughput. This requirement is dependent on the deployment of analysis capabilities at SLAC, and is about five years away. (8) It is difficult to achieve high data transfer throughput to sites in China. Projects that need to transfer data in or out of China are encouraged to deploy test and measurement infrastructure (e.g. perfSONAR) and allow time for performance tuning.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The development of a high-throughput gradient array apparatus for the study of porous polymer networks.

A gradient array apparatus was constructed for the study of porous polymers produced using the process of chemically-induced phase separation (CIPS). The apparatus consisted of a 60 element, two-dimensional array in which a temperature gradient was placed in the y-direction and composition was varied in the x-direction. The apparatus allowed for changes in opacity of blends to be monitored as a function of temperature and cure time by taking images of the array with time. The apparatus was validated by dispense a single blend composition into all 60 wells of the array and curing them for 24 hours and doing the experiment in triplicate. Variations in micron scale phase separation were readily observed as a function of both curing time and temperature and there was very good well-to-well consistency as well as trial-to-trial consistency. Poragen of samples varying with respect to cure temperature was removed and SEM images were obtained. The results obtained showed that cure temperature had a dramatic affect on sample morphology, and combining data obtained from visual observations made during the curing process with SEM data can enable a much better understanding of the CIPS process and provide predictive capability through the relatively facile generation of composition-process-morphology relationships. Data quality could be greatly enhanced by making further improvements in the apparatus. The primary improvements contemplated include the use of a more uniform light source, an optical table, and a CCD camera with data analysis software. These improvements would enable quantification of the amount of scattered light generated from individual elements as a function of cure time. In addition to the gradient array development, porous composites were produced by incorporating metal particles into a blend of poragen, epoxy resin, and crosslinker. The variables involved in the experiment were metal particle composition, primary metal particle size, metal concentration, and poragen composition. A total of 16 different porous composites were produced and characterized using SEM. In general, the results showed that pore morphology and the distribution of metal particles was dependent on multiple factors. For example, the use of silver nanoparticles did not significantly affect pore morphology for composites derived from decanol as the poragen, but exceptionally large pores were obtained with the use of decane as the poragen. With regard to the effect of metal particle size, silver nanoparticles were essentially exclusively dispered in the polymer matrix while silver microparticles were found in pores. For nickel particles, both nanoparticles and microparticles were largely dispersed in the polymer matrix and not in the pores.

36 MATERIALS SCIENCE↗