Search NASA⌕ Search

SEARCH · Search NASA

Results for “component analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Elastomer Mechanics of Cross-Linked Linear-Ring Polymer Blends

Cross-linking a blend of linear and ring polymers creates a new topology-based dual-network elastomer in which the two components differ significantly in their topology. We use molecular simulations and topological analysis to examine key mechanical properties as functions of ring polymer volume fraction Φ R . For Φ R < Φ R *, where the rings begin to overlap, the network shear modulus G and the maximum stretch ratio λ p are weakly dependent on Φ R . For Φ R > Φ R *, entanglements trapped in the network are diluted as the rings overlap, leading to a significant decrease in G and an increase in λ p with increasing Φ R . Here, the peak tensile stress, σ p , exhibits a maximum around Φ R *, indicating an enhancement of network strength due to the stronger cohesion from the entanglements between linear and ring polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying motion blur by imaging shock front propagation with broadband and narrowband X-ray sources

Time-integrated radiography using MeV Bremsstrahlung X-ray sources is the norm for imaging during system-level testing of components and structures under dynamic condition. One source of error in the analysis of the time-integrated radiography data sets stems from motion blur which smears out sharp interfaces to a greater degree with longer exposure times, which become necessary to provide sufficient signal-to-noise with low X-ray penetration of objects of interest. To quantify motion blur, a 1D shock wave through PMMA was investigated experimentally at The Dynamic Compression Sector at The Advanced Photon Source (DCS@APS) with tapered broadband and 25.46 ± 1.06 keV narrowband X-rays. Four cameras with different exposure times were used for each experiment to compare the effect that exposure time has on motion blur. In addition, our methodology to accurately simulate motion blur in terms of transmission and shape is presented and compared to our experimental results and quantified. There is a high level of agreement between the experimental and simulation results across the range of data sets investigated in this study with a percent difference range of 0.29–1.31% for the four shots. The methodology of this work serves as a steppingstone towards a physically validated model that could be used in conjunction with experimental results to deconvolve physical parameters, densities, and interfaces of interest in a way that would not be possible with experimental results alone.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selection function of clusters in Dark Energy Survey year 3 data from cross-matching with South Pole Telescope detections

Context. Galaxy clusters selected based on overdensities of galaxies in photometric surveys provide the largest cluster samples. However, modeling the selection function of such samples is complicated by noncluster members projected along the line of sight (projection effects) and the potential detection of unvirialized objects (contamination). Aims. We empirically constrained the magnitude of these effects by cross-matching galaxy clusters selected in the Dark Energy Survey data with the redMaPPer algorithm with significant detections in three South Pole Telescope surveys (SZ, pol-ECS, pol-500d). Methods. For matched clusters, we augmented the redMaPPer catalog with the SPT detection significance. For unmatched objects we used the SPT detection threshold as an upper limit on the SZe signature. Using a Bayesian population model applied to the collected multiwavelength data, we explored various physically motivated models to describe the relationship between observed richness and halo mass. Results. Our analysis reveals a clear preference for models with an additional skewed scatter component associated with projection effects over a purely log-normal scatter model. We rule out significant contamination by unvirialized objects at the high-richness end of the sample. While dedicated simulations offer a well-fitting calibration of projection effects, our findings suggest the presence of redshift-dependent trends that these simulations may not have captured. Our findings highlight that modeling the selection function of optically detected clusters remains a complicated challenge that requires a combination of simulation and data-driven approaches.

79 ASTRONOMY AND ASTROPHYSICS↗

Wall heating by subcritical energetic electrons generated by the runaway electron avalanche source *

Abstract Subcritical energetic electrons (SEEs) produced by the runaway electron (RE) avalanche source at energies below the runaway threshold are found to be the primary contributor to surface heating of plasma-facing components (PFCs) during final loss events. This finding is supported by theoretical analysis, computational modeling with the Kinetic Orbit Runaway electrons Code (KORC), and qualitative agreement with DIII-D experimental observations. The avalanche source generates significantly more secondary electrons below the runaway threshold, which thermalize rapidly when well-confined. However, during a final loss event, the RE beam impacts the first wall, and SEEs are deconfined before they can thermalize. Additionally, because the energy deposition length decreases faster than energy, the deposited energy density, and thus the maximum PFC surface temperature change, is larger for SEEs than REs. KORC simulations employ an analytic first wall to model particle deconfinement onto a non-axisymmetric wall composed of individual tiles. PFC surface heating is calculated using a 1D model extended to include an energy-dependent deposition length scale. Simulations of DIII-D qualitatively agree with infrared (IR) imaging only when SEEs from the avalanche source are included. These results demonstrate that SEEs are the dominant contributor to PFC surface heating and indicate that the avalanche source plays a critical role in the PFC damage caused during final loss events. The prominence of SEEs also has important implications for interpreting IR imaging, one of the primary diagnostics for RE-wall interaction diagnosis, despite REs dominating the energy and current density. This result improves predictions of wall damage due to post-disruption REs to estimate material lifetime and design RE mitigation systems for ITER and future reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2024

This report presents an enhanced performance evaluation of turbine driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10 year period while yearly estimates for reliability are provided for the entire study period. No increasing trends were identified for TDPs for the most recent 10 year period.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Correlating Power Outage Spread with Infrastructure Interdependencies During Hurricanes

Power outages caused by extreme weather events, such as hurricanes, can significantly disrupt essential services and delay recovery efforts, underscoring the importance of enhancing our infrastructure's resilience. This study investigates the spread of power outages during hurricanes by analyzing the correlation between the network of critical infrastructure and outage propagation. We leveraged datasets from Hurricanemapping.com, the North American Energy Resilience Model Interdependency Analysis (NAERM-IA), and historical power outage data from the Oak Ridge National Laboratory (ORNL)'s EAGLE-I system. Our analysis reveals a consistent positive correlation between the extent of critical infrastructure components accessible within a certain number of steps (k-hop distance) from initial impact areas and the occurrence of power outages in broader regions. This insight suggests that understanding the interconnectedness among critical infrastructure elements is key to identifying areas indirectly affected by extreme weather events.

Bose, Avishek↗

Augmented Reality Technologies for Radiation Safety Training: A Systematic Review of Sensor Integration and Visualization Approaches

This paper presents a comprehensive systematic review examining the application of augmented reality (AR) and sensor technologies for visualizing ionizing radiation in virtual training environments. The review methodology involved systematic identification and analysis of the relevant literature based on predetermined criteria including publication type, year of publication, application domain, and technological approach. The literature search encompassed publications from 2011 to 2021 across four major academic databases: Web of Science, Google Scholar, IEEE Xplore, and Scopus. Through rigorous screening following PRISMA 2020 guidelines, 23 research articles met the inclusion criteria for detailed analysis. From 404 initial database records, 360 were excluded during title/abstract screening (primarily for lacking AR components, radiation focus, or training applications) and 4 during full-text assessment (all for lacking sensor integration). The findings reveal that AR-based ionizing radiation visualization has been successfully implemented across diverse domains, including nuclear facility operations, medical procedures, CERN research activities, and educational and monitoring applications. The analysis identified multiple dimensions of impact, encompassing distinct benefits, emerging opportunities, and implementation challenges associated with AR deployment for ionizing radiation training. Each of these dimensions is comprehensively examined and documented within this review. Additionally, this study identifies critical research gaps that currently limit the full potential of AR technology in supporting ionizing radiation training programs. These gaps are systematically analyzed and discussed to establish clear directions for future research endeavors in this emerging field.

61 - RADIATION PROTECTION AND DOSIMETRY↗

Build-To-Replace Strategy to Reduce O&M Costs of Advanced Reactors

This paper targets the goal of reducing fixed operations and maintenance (O&M) costs to $2/MWh for advanced reactor (AR) designs, an order of magnitude reduction from current nuclear fleets. Such goal will be severely constrained if the underlying assumptions of O&M approaches and practices are not questioned and reexamined, especially today when changes can be implemented effectively and efficiently. Achieving a 90% reduction in AR O&M costs requires a completely new way of thinking – a paradigm shift – not through incremental, technology-focused approaches alone. Here, we address this challenge by evaluating the impact of moving to shorter design life for major structures, systems and components (SSCs) and shorter, more predictable refurbishment cycles as modeled by the commercial airline industry. This paper provides a brief overview of this different mindset to O&M applied to ARs: the build-to-replace approach. We provide a direct example of analysis of a build-to-replace scenario by identifying and evaluating scenarios for reduced system and component lifetimes and associated replacement and refurbishment schedules to evaluate impacts on O&M costs and other lifecycle elements such as SSC reliability.

97 - MATHEMATICS AND COMPUTING↗

Erosion of high-Z refractory coatings for helicon plasma source window

Proto-MPEX (Materials Plasma Exposure eXperiment), a linear plasma device (LPD), using a high power radio frequency (RF) (⩾100 kW, 13.56 MHz) helicon plasma source, has suffered RF sheath-induced window erosion. The sputtered impurities from the window surface transport toward the downstream target affecting plasma-material interaction studies. The rectified sheath voltage formed was high enough to cause window erosion by light ions due to its low-Z components (e.g. Si 3 N 4 and AlN). Hence, we are proposing impurity mitigation strategies, which involve the application of a Faraday screen to lower the rectified sheath voltage and the application of high-Z refractory coatings on the existing window plasma-facing surface. In this work, we report the erosion of two different coatings, i.e., tantalum oxide (Ta 2 O 5 ) and hafnium oxide (HfO 2 ) on a silicon nitride (Si 3 N 4 ) window material under conditions of low-energy deuterium (D) ion impact, well below the Ta 2 O 5 sputtering energy threshold (i.e. 250 eV). The test samples were RF-biased and exposed to a high D-ion fluence (∼10 26 m −2 ) in Plasma Interaction with Surface Component Experimental Station (PISCES-A) LPD. The experimentally measured sputtering yields of the high-Z refractory coatings below the sputtering energy threshold of Ta 2 O 5 indicate an increased erosion due to the plasma impurities, especially due to oxygen. Improving the vacuum level could reduce the oxygen impurities and increase the lifespan of the coated helicon window for plasma operation. Post-surface analysis indicates no preferential erosion of oxygen or enrichment of the high-Z surface component. This is likely due to an effective energy transfer from the impurity ion for sputtering of the high-Z component in the coating. With the reduced rectified sheath voltage at the window surface and improved vacuum conditions, the proposed high-Z refractory coatings offer a promising solution for reducing window erosion in future MPEX plasma operations at ORNL.

RF bias↗

From Machine Learning to Machine Reasoning: A Model-based Approach to Analyze Equipment Reliability Data

In current nuclear power plants (NPPs) a large amount of condition-based data which can be used to assess and monitor component health and performance. Assessing component health from such data can be performed with a large variety of methods. While the analysis of numeric data can be performed with several methods, the extraction of information from textual data remains a challenge. Currently employed natural language processing (NLP) methods do not really provide quantitative information that might be contained in IRs. In addition, the integration of numeric and textual data to identify possible causal relationships between data elements is still an unresolved challenge. This paper presents an approach to extract information from textual (e.g., incident or maintenance reports) and numeric data that relies on model based system engineer (MBSE) models. MBSE are diagrams designed to represent system and component dependencies (from both a form and functional point of view). In our approach, MBSE models emulate system engineer knowledge about component/system architecture. NLP methods are employed to perform syntactic and semantic analyses. Syntactic analysis analyzes the grammatical structure of a sentence while semantic analysis is designed to analyze the logic structure of a sentence. An innovative element of our approach is that semantic analysis uses MBSE models to identify links between textual elements. Similarly, numeric data is directly linked to elements of the MBSE models in order to map which functions are being monitored.

97 - MATHEMATICS AND COMPUTING↗

BESSIE: Battery & Energy Storage Supply Chain Analysis, Mitigation Deployment, and Tools

Battery energy storage systems (BESS) and their associated power electronic interfaces are key components to delivering clean and more resilient energy, providing much-needed fast-ramping, emergency discharge, generation, and operations support to the electric grid. These services have grown to be invaluable over the past ten years and will soon be an irreplaceable element of energy delivery. The Idaho National Laboratory (INL) strives to address these challenges through a strategic approach to supply chain risk assessment and mitigation for BESS and related digital energy equipment through the BESSIE project under the Center for Securing Digital Energy Technology. Recognizing that decreasing dependence on a foreign supply chain will take significant time and investment, BESSIE’s focus is strategically addressing battery supply chain risks by pairing short-term steps to operate securely through today’s risks with long-term steps to shape the supply chain over the coming years.

25 ENERGY STORAGE↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry

The consequences of failure for balance-of-systems components (such as photovoltaic (PV) cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and overtemperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared with field-degraded specimens. A total of 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens), including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components.

cable connectors↗

Thermal shock resistance of lightweight cements developed for geothermal conditions

Cements are a critical component in well construction, as they act to prevent well fluid and gas escape, prevent corrosion of the casing, and strengthen the wellbore to prevent deformation. Under the high temperature/pressure conditions common in geothermal systems, the injection of cold water for energy production is expected to induce cyclic damage to the borehole cement through the rapid temperature fluctuations. These “thermal shocks” are expected to cause casing shrinkage, annulus formation, and cement tensile stresses. To understand the effect of cold water injection on the wellbore environment, a set of rock-cement-steel samples were created to simulate the structure of a geothermal well. Lightweight thermally-insulating cement blends were tested under thermal shock conditions in this study. In each test, the samples were pressurized to an effective pressure of ~3.5 MPa and placed at high temperatures. Thermal shocks were performed by injecting cold water (~10-15 °C) through the samples at a constant rate while keeping the samples at high temperatures until the sample temperature stopped decreasing and deformation ceased. Eight thermal shock tests were conducted with each sample – two at 100 °C and six at 200 °C. Post-tests analysis was then conducted by cutting open each sample to examine the damage in each component of the simulated wellbore. Experimental results suggest that all samples experienced similar degrees of axial and lateral contraction during cold water injection, but for the most part this contraction is recoverable when injection halts. Post-test analysis revealed that fly ash cenosphere pre-treatment had the best effect on improving thermal shock resistance in the cement blends. Thermomechanical modeling of likely stress paths experienced by the cements during heating/cooling cycles shows that elasto-plastic cement constitutive behavior results in most plastic strain occurring during the initial heating steps, with mostly elastic strain occurring during the thermal shock cycles. In conclusion, this agrees with experimental evidence, suggesting that cement damage from shocking occurs via other mechanisms such as chemical alteration, corrosion, and fatigue.

36 MATERIALS SCIENCE↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry [Slides]

The consequences of failure for balance of systems (BoS) components (such as PV cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and over-temperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared to field-degraded specimens. 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens) including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross-section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier-transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components. Updated from 2023 NIST/UL Workshop on Photovoltaic Materials Durability (website: https://events.ul.com/WPMogn?rt=aAuoWsl4E0KaORLCMeOgfA) and 2024 PVRW workshop (https://pvrw.nrel.gov/past-proceedings).

14 SOLAR ENERGY↗

Advanced EXAFS analysis techniques applied to the L -edges of the lanthanide oxides

The unique properties of the lanthanide (Ln) elements make them critical components of modern technologies, such as lasers, anti-corrosive films and catalysts. Thus, there is significant interest in establishing structure–property relationships for Ln-containing materials to advance these technologies. Extended X-ray absorption fine structure (EXAFS) is an excellent technique for this task considering its ability to determine the average local structure around the Ln atoms for both crystalline and amorphous materials. However, the limited availability of EXAFS reference spectra of the Ln oxides and challenges in the EXAFS analysis have hindered the application of this technique to these elements. The challenges include the limited k-range available for the analysis due to the superposition of L-edges on the EXAFS, multielectron excitations (MEEs) creating erroneous peaks in the EXAFS and the presence of inequivalent absorption sites. Herein, we removed MEEs to model the local atomic environment more accurately for light Ln oxides. Further, we investigated the use of cubic and non-cubic lattice expansion to minimize the fitting parameters needed and connect the fitting parameters to physically meaningful crystal parameters. The cubic expansion reduced the number of fitting parameters but resulted in a statistically worse fit. The non-cubic expansion resulted in a similar quality fit and showed non-isotropic expansion in the crystal lattice of Nd 2 O 3 . In total, the EXAFS spectra and the fits for the entire set of Ln oxides (excluding promethium) are included. The knowledge developed here can assist in the structural determination of a wide variety of Ln compounds and can further studies on their structure–property relationships.

36 MATERIALS SCIENCE↗

Economic Analysis of the NIF Optics Recycle Loop Systems Investment Options: SAE 560 - Economic Considerations for Systems Engineering at University of Southern California

The National Ignition Facility (NIF) relies on large-scale precision optics to deliver high-energy laser pulses for fusion and high-energy-density physics research; however, the NIF routinely operates above the damage threshold for those optics, decreasing their effectiveness with every experiment. A production line composed of several dozen highly specialized processing systems, collectively referred to as the ‘optics recycle loop’, was established to support refurbishment and re-use of these critical components to reduce reliance on high-cost and high-risk optic replacement strategies. This analysis aims to identify the most cost-effective investment options for improving recycle loop throughput by maximizing availability and production flexibility while minimizing the engineering and infrastructure efforts and cost.

42 ENGINEERING↗

Integration and Optimization of a Waste Heat Driven Organic Rankine Cycle for Power Generation in Wastewater Treatment Plants

The study focuses on achieving energy self-sufficiency in Wastewater Treatment Plants by proposing a comprehensive model for integrating, sizing, and optimizing an Organic Rankine Cycle system. The Organic Rankine Cycle system is designed to utilize waste heat from the gensets at As Samra Wastewater Treatment Plant in Jordan, where it will contribute to the overall electrical energy supply of the plant. Real data from As Samra Wastewater Treatment Plant is used to model and calculate the available waste heat using TRNSYS® software. The Organic Rankine Cycle model is then developed using ASPEN PLUS® software to explore the impact of operational parameters and determine their optimal values for maximizing the plant's energy profile. An economic analysis is conducted to assess the feasibility of the proposed model, considering system components, installation, operation, and maintenance costs. To optimize the Organic Rankine Cycle system, the study employs the Multi-Output Support Vector Regression technique to capture nonlinear relationships between independent variables (fluid type, turbine inlet pressure, turbine inlet temperature, turbine outlet pressure, and mass flow rate) and dependent variables (pump power input, waste heat input, and turbine specific work). The Osprey optimization algorithm is used to address the multi-objective optimization problem, with the proposed Pareto-based Osprey Optimization Algorithm and the Multi-Objective Particle Swarm Optimization technique being employed to evaluate critical performance and economic parameters such as system thermal efficiency, net power output, and the levelized cost of electricity. The results of the optimization strategies indicate that the M-SVR model's prediction accuracy is significantly improved after parameter optimization, with the model returning high R 2 and low Mean Square Error values of 0.991 and 0.00216, respectively. The Pareto-Based Osprey Optimization Algorithm optimizer identifies the best working fluid as Isobutane/Isopentane in a ratio of 66:34, with optimal turbine inlet pressure and temperature of 15 bars and 218 °C, respectively. In conclusion, the Organic Rankine Cycle model at these optimal conditions achieves a cycle efficiency of 19.93% and an Levelized Cost of Electricity value of 0.0353 USD/kWh.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ITER ECH Transmission Line System Design and Status

The electron cyclotron (EC) heating & current drive (H&CD) system on ITER provides plasma heating by generating, transmitting, and launching high-intensity, high-frequency (170 GHz) electromagnetic wave energy steerable across the plasma cross-section. The transmission line (TL) subsystem connects the Matching Optics Unit (MOU) on each of the 24 gyrotrons to the 32 feed points in the four upper launchers and the 24 feed points in the equatorial launcher. Each TL must be able to operate at up to 1.2 MW of input power for up to 1 hour pulse lengths. The TL system contains 50 mm water-cooled corrugated waveguide, 90o miter bends, 140o miter bends, polarizer miter bend pairs, switches, expansion units, pumpouts, DC breaks, MOU-TL adapters, Radio Frequency (RF) loads, and isolation shutter valves. A detailed finite element analysis has been used to verify the thermo-mechanical performance of each component. The microwave performance has been analyzed using a 2-D electromagnetic code combined with a Monte Carlo code. This approach allows the impact of manufacturing and installation tolerances to be assessed and optimized to provide a high probability of achieving the system performance requirements. Prototypes of the waveguide and TL components have been fabricated and tested at high-power. Production contracts are now being issued for fabrication and delivery of the waveguide and components to ITER.

Hanson, Gregory↗