SEARCH · Search NASA
Results for “concentrating solar thermal”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Thermal expansion behavior of LDEF metal matrix composites
The effects of the space environment on the thermal expansion stability of metal matrix composites (graphite/Al and graphite/Mg) will be presented. A sample from each category of metal matrix composites mounted on the leading and trailing edge was chosen for analysis of the temperature-time-thermal strain histories. Typical thermal expansion curves over the same range of temperature were selected at the beginning, mid, and end of the recording duration. The thermal expansion of selected post-flight LDEF samples were measured over the same range of temperature in the laboratory using a Michelson laser interferometer. The thermal strains were monitored concurrently with a laser interferometer and a mounted strain gage.
Chapter 3: Thermal Exchanges and Temperature Stress
Thermal comfort during space flight is discussed. Heat production of man during space flight and wear loss as a mean of dissipating heat are described. Water cooled garments are also considered, along with tolerance for extreme heat and body heat storage. Models of human temperature regulation are presented in the form of documented FORTRAN programs.
Tracing the Source of Carbon Oxides on the Large Moons of Uranus
The Uranian moons Ariel, Umbriel, Titania, and Oberon are enriched in CO 2 mixed with CO, but the origin(s) of these carbon oxides, be they primarily native or radiolytic, remain(s) uncertain. Using data collected by NIRSpec on the James Webb Space Telescope (JWST), we measured the spectral signature of CO 2 and other carbon oxides to help disentangle these hypotheses. Through comparison to laboratory data, we find that many of the detected spectral features are consistent with CO 2 ice, including 12 CO2 scattering peaks (4.15–4.26 μm), multilobe 13 CO 2 bands (4.35–4.43 μm), and CO 2 biphonon and triphonon modes (4.80–5.25 μm). Our measurements show that CO 2 and CO are concentrated on the trailing hemispheres of the inner moons Ariel and Umbriel, potentially supporting a radiolytic production hypothesis, consistent with prior ground-based results. However, many of the identified spectral features are only observed in thick crystalline ice deposits measured in the laboratory, which may be difficult to form via radiolysis of carbon-bearing material mixed in icy regoliths. Similarly, the data exhibit weak 4.02 and 4.40 μm bands, hinting at the presence of carbonate minerals and 13 CO 2 clathrates, respectively, possibly formed in the interiors of these moons. Furthermore, JWST has revealed that CO 2 is widespread at Uranus, present in its system of rings, ring moons, and irregular satellites, consistent with its largest moons accreting CO 2 and other carbon oxides from the Uranian subnebula. We conclude that exposed carbon oxides are potentially native, with their surface distributions shaped by charged particle irradiation and seasonal sublimation–condensation cycles.
Thermal Analysis on Large Format Lithium-Ion Batteries in Thermal Runaway
Lithium-ion (Li-ion) batteries can deliver electrical power across a large range of applications, and large format versions of these batteries are common in aerospace for their low mass and energy dense properties. Li-ion cells usage has increased as they are more power dense than fuel cells and have overall higher performance over lead-acid/NiCd batteries. However, Li-ion cells can experience Thermal Runaway (TR) via electro-chemical, mechanical, or thermal abuse. TR is a phenomenon where the stored energy in a cell is rapidly released along with vented gases and other effluents. A cell is generally determined to be in TR if its internal heat generation has surpassed its ability to dissipate that heat. If a Li-ion cell enters TR, propagation within the battery may occur. Propagation is the chain reaction that can occur to nearby cells due to a cell that has entered TR initially. Understanding a battery’s susceptiveness to propagation is necessary to evaluate risks associated with TR phenomenon. To determine if a battery is designed in a sufficient manner to prevent battery propagation if single cell TR occurs, testing and thermal analysis of the battery must be conducted. The presentation for TFAWS 2026 will cover considerations for battery TR thermal analysis, such as: testing methods, influences on the cells, failure mechanisms, and TR parameters. This presentation will include a walkthrough of an example battery TR thermal analysis, and the results thereof.
Mechanistic origin of solvent-dependent thermal stability in sodiated Sn anodes for sodium-ion batteries
Understanding the thermal stability of high-energy density alloy anodes is critical for the safe deployment of sodium-ion batteries (SIBs). Here, accelerating rate calorimetry (ARC), post-mortem characterizations, and density functional theory (DFT) calculations are combined to understand the thermal reactivity of fully sodiated Sn, Sn-hard carbon (HC) blends, and HC anodes in carbonate- and ether-based electrolytes. ARC measurements show that propylene carbonate (PC) causes earlier self-heating rate (SHR) onset and higher reactivity than tetraethylene glycol dimethyl ether (TEGDME), indicating inferior thermal stability. Sodiated Sn exhibits better thermal stability than sodiated HC, while Sn-HC blends show intermediate behavior that improves with increasing Sn content. Post-ARC analyses reveal desodiation of Na15Sn4 to metallic Sn with particle coalescence, whereas Sn-HC blends and HC retain finer morphologies. PC promotes Sn oxidation to SnO, while TEGDME suppresses oxide formation; NaPF6-containing electrolytes additionally form NaF. DFT calculations show that PC adsorption lowers Na extraction energy and enhances interfacial electronic interactions, facilitating Na release and reductive decomposition. These results establish a direct correlation between solvent-dependent reaction pathways and thermal stability in SIB alloy anodes.
Sixth Annual Thermal and Fluids Analysis Workshop
The Sixth Annual Thermal and Fluids Analysis Workshop was held at the Ohio Aerospace Institute, Brook Park, Ohio cosponsored by NASA Lewis Research Center and the Ohio Aerospace Institute, August 15-19, 1994. The workshop consisted of classes, vendor demonstrations, and paper sessions. The classes and vendor demonstrations provided participants with the information on widely used tools for thermal and fluids analysis. The paper sessions provided a forum for the exchange of information and ideas among thermal and fluids analysis. Paper topics included advances a uses of established thermal and fluids computer codes (such as SINDA and TRASYS) as well as unique modeling techniques and applications.
A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe
NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.
A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe
NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.
Single-residue engineering of lambda (λ) antibody light chains reduces conformational flexibility and enhances thermal stability
Not provided.
Global Model Estimates of Atmospheric Al, Ca, Fe, Si, and Ti from Dust and Non-Dust Aerosols Informed by EMIT Surface Mineralogy and Evaluated Against Observations
Atmospheric deposition of micro-nutrients like Fe has been shown to be important for ocean biogeochemistry. The largest source of atmospheric Fe and other elements (e.g., Ca, Al, Si, and Ti) is desert dust, although there are significant non-dust sources in some regions. However, past estimates of these elements have been substantially uncertain due to limited information about the composition of the desert source regions. Here we use elemental distributions estimated from new Earth Surface Mineral Dust Source Investigation (EMIT) observations, which provide mineralogical composition at the surface of the Earth based on imaging spectroscopy measurements from the International Space Station. We add in other sources of these elements (anthropogenic and natural) and compare to a compilation of available surface concentration data from stations over land and from shipborne observations. Our results suggest that the modeled distribution is similar to available observations, but discrepancies still exist in both natural desert dust regions as well as regions dominated by anthropogenic sources. Global budgets for the elements Ca, Al, Fe, Si, and Ti suggest that desert dust remains the dominant source for these elements but anthropogenic or volcanic sources are also important for these elements. Changes in elemental distributions since preindustrial times were also estimated.
SCOAPE-II: A 2024 Multiplatform Measurement Campaign off the US Gulf Coast to Assess Oil and Gas Emissions on the Outer Continental Shelf
Nine years ago, the Department of Interior’s Bureau of Ocean Energy Management (BOEM), the Agency with Air Quality (AQ) jurisdiction over the Outer Continental Shelf (OCS) of the US Gulf Coast west of 87.5° W longitude, asked NASA to determine the feasibility of using satellite data to measure offshore emissions in a region of concentrated oil and natural gas (ONG) operations. To study this issue NASA and BOEM conducted the May 2019 Satellite Coastal and Oceanic Atmospheric Pollution Experiment (SCOAPE) cruise in the Gulf. SCOAPE addressed both technological and scientific issues related to measuring nitrogen dioxide (NO 2 , a common air pollutant), including contrasting near-shore and deepwater regimes. Given the April 2023 launch of the geostationary Tropospheric Emissions: Monitoring of Pollution (TEMPO) AQ satellite, a 2024 SCOAPE-II was conducted in the Gulf with both ship and aircraft measurements. We present an overview of the SCOAPE-II campaign, analysis and validation of satellite-observed NO 2 , and evaluate measurements of methane from ship, aircraft, and satellite near ONG platforms. Our SCOAPE-II results are as follows: 1) Satellite NO 2 measurements (∼13:30 local time) from the TROPOspheric Monitoring Instrument (TROPOMI) are more accurate than TEMPO’s hourly scans (8.6% vs. 23.6% mean absolute bias); a new version of TEMPO data is currently being processed; 2) ship and aircraft measurements captured dozens of NO 2 and methane plumes from ONG operations, showing that they are persistent emitters; 3) satellite measurements of methane failed to replicate ship and aircraft measurements, presenting ongoing challenges for operational emissions monitoring over the Gulf.
Decoupling the capacity fade contributions in polymer electrolyte-based high-voltage solid-state batteries
Polymer electrolyte (PE)-based solid-state batteries (PE-SSBs) made with high-voltage cathodes are known to suffer from severe capacity fade, stemming primarily from the poor oxidative stability of most PEs under high-voltage cycling conditions. PEs also suffer from greater ion-transport limitations compared to liquid or solid electrolytes. However, often, these limitations are collectively stated to be responsible for the observed capacity fade, and it is challenging to decouple the contributions of different factors. Herein, a tunable cell fabrication platform was developed to systematically investigate and decouple the two primary capacity fade drivers (cell impedance growth and kinetic limitations), while keeping the other cell parameters constant. Three PE types with distinct transport characteristics were compared. By utilizing a voltage profile analysis method, the contribution of the cell's internal impedance growth was quantitatively decoupled from the kinetic limitations stemming from the high concentration gradient in the polymer catholyte and slow charge transfer reactions. We demonstrate that the high interfacial impedance did not necessarily correlate with the high capacity fade rate. Kinetic limitations that are not reflected by impedance measurements can play a dominant role in causing cumulative capacity decay.
Development of the METMAN Thermal Desktop Human Model for System Integration
Human thermal analysis and model development inform NASA’s space suit development, vehicle/habitat design, and survivability studies. Historically, human thermal models such as the 41-node metabolic man (METMAN) and the Wissler model have been standalone software tools developed with FORTRAN, a programming language known for its high performance in computationally intensive applications. Though efficient, these standalone programs pose challenges to coupled human-system analysis with detailed life support and thermal control subsystem models in other commercial software. This paper describes the conversion of the METMAN human thermal model from a standalone FORTRAN program to a model in Thermal Desktop (Ansys), a commonly used CAD-based simulation software for engineering that specializes in heat transfer, thermal radiation, and fluid flow analysis. This format was chosen to best facilitate model sharing and compatibility, enabling the direct integration of METMAN human thermal analysis with subsystem models across NASA programs and commercial partners.
Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor
Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.
Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Change Material Heat Capacitor
A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft’s propylene glycol-water mixture coolant system. Testing was performed with the phase change material contained under sealed conditions after a degassing procedure and exposed to atmosphere without prior degassing. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements and theoretical N-Pentadecane storage capacity.