Magnet System Design and Optimization for a Novel Plasmoid Magnetic Reconnection Thruster Prototype
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.
UL Solutions produced this report as a summary of a test series executed at Sandia National Laboratories that they funded. This report was approved for release by UL Solutions in October 2025 and released in 2026 on their website at https://www.ul.com/insights/methods-and-recommendations-large-scale-deflagration-testing-battery-energy-storage-system.
The present application discloses a method of making a preform for use in manufacturing a component made of a composite material. The method includes stitching fibers onto a film to form a fiber bed in a two-dimensional shape, removing the film from the fiber bed, and adjusting the fiber bed into a three-dimensional shape to form the preform.
The Cyber-Informed Engineering Photovoltaic Analysis Tool (CIEPAT) was developed in collaboration with the U.S. Department of Energy's Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This tool is an energy source subcomponent integrated into the CIEMAT ecosystem and is developed to enhance the security and resilience of Photovoltaic installations by incorporating Cyber-Informed Engineering (CIE) principles into the deployment of PV systems.
This project, conducted by TDA Research, Inc. in collaboration with GE Research under DOE Award DE-FE0032261, developed and demonstrated advanced structured sorbent-coated contactors for the high-performance Direct Air Capture (DAC) of CO 2 .
A gaseous fuel engine system includes a hydrogen fuel supply, an engine housing having an intake port extending to a cylinder, and an intake runner. The intake runner includes a valve mount attached to a conduit and having a valve mounting face, and a gaseous fuel admission valve is mounted upon the valve mounting face. A hydrogen fuel passage extends from the valve mount through the conduit and is oriented angularly to at least one of a clamping face of the intake runner or the valve mounting face. Related apparatus and methodology is also disclosed.
Over the past decade, academic research on advanced controls has slowly transitioned into new software platforms, giving rise to various companies developing and deploying these innovative products, including solutions for light commercial HVAC systems. However, the current workforce remains widely unprepared to install, maintain and operate these systems, particularly complex software-based control platforms, as most workforce training programs still focus on traditional building automation for large commercial buildings. This paper presents the development and piloting of curriculum for three key types of professionals: ● Technicians (trade-level): installing and maintaining modern high-performance HVAC systems and controls ● Programmers (undergrad-level): developing and implementing advanced controls ● Engineers and energy professionals (undergrad/grad-level): managing and evaluating system performance We share details of the material developed including training videos, open-source software, instruction manuals. We also present the results of a pilot implementation of the training materials with real students.
The Molokai, Hawaii, Energy to Communities (E2C) Energyshed project represents a collaborative effort between the National Laboratory of the Rockies, Shake Energy Collaborative, the Molokai Clean Energy Hui, Sustainable Molokai, and Ho'ahu Energy Cooperative Molokai to advance Molokai's Community Energy Resilience Action Plan (CERAP). Supported by Hawaiian Electric Company and the Hawaii State Energy Office, the initiative aims to develop a community-defined portfolio of renewable energy solutions that enhance energy resilience while aligning with the Hawaiian Electric Integrated Grid Plan (IGP) and Molokai's energy goals. Phase 1 focused on technical analyses and community engagement to co-design feasible energy scenarios. Challenges such as grid upgrades, storage sizing, and inverter ride-through standards were addressed to align technical and operational requirements with community preferences. The project equips Molokai with actionable data and insights to implement energy initiatives while ensuring resilient and culturally informed solutions. Future efforts aim to finalize project designs, secure interconnection agreements, and deploy energy projects that reflect community priorities and technical feasibility.
Here, this work introduces a new benchmark problem for calculating shutdown dose rates (SDDRs) aimed at fusion reactor applications. The model is designed to represent a simplified version of a typical ITER port plug. The responses of interest include neutron flux, gamma flux, and gamma SDDR at 12 different locations scattered throughout the port. This article outlines the geometry specifications of the problem, provides material definitions for the components, specifies the required responses to be calculated, and presents the source definition information. The need for this benchmark arises from the limited availability of publicly accessible references, with only one benchmark representing the typical dimensions and materials found in fusion systems. This existing benchmark has been cited extensively, reflecting the demand within the scientific community to test both established and novel workflows for SDDR calculations. However, since its presentation at a conference in 2011, the results have become increasingly well known. Moreover, the absence of formal publication and peer review has led to the details of this benchmark being extracted from secondary sources, such as subsequent studies that reference it. As a result, analysts are left with significant flexibility in interpreting the key parameters, which can be adjusted to account for unknown systematic errors, ultimately reproducing the already well-known responses. This new benchmark serves as an updated version of that earlier work, with the aim of providing a more reliable description of the materials and their impurities, which is crucial for assessing activation and subsequent gamma emission. Additionally, it seeks to provide a geometry that more closely represents an ITER port plug. The improvements in the problem definition will lead to a more reproducible benchmark problem, while also presenting the radiation transport community with a completely new challenge. The results will be published in a future article to allow analysts adequate time to analyze this problem independently.
Low-level jets (LLJs)—wind speed maxima typically occurring a few hundred meters above the surface—are common off the U.S. East Coast and influence many atmospheric processes with societal importance, including cloud formation, aviation safety, and search-and-rescue. However, their vertical structure and frequency remain poorly quantified due to limited offshore observations. This study presents new scanning Doppler LiDAR and infrared spectroradiometer data from the 2024 summer deployment of an offshore barge during the Wind Forecast Improvement Project 3. These coupled wind and temperature profiles provide unprecedented resolution to assess LLJ behavior and model performance. LLJs occurred in over 21% of observed profiles, with a weak diurnal preference for nighttime and early morning hours and maximum winds typically near 300 m. Both ERA5 and High-Resolution Rapid Refresh analysis underestimate jet wind speeds and misrepresent the boundary layer thermal structure. These results highlight persistent model biases and the critical need for high-resolution offshore observations.
Endometriosis, defined as the ectopic growth of endometrial tissue outside of the uterine cavity, is an inflammatory and hormone-dependent disease that causes excruciating pelvic pain, infertility, and significantly decreases quality of life in affected patients. The JUN N-terminal kinases (JNKs) are a leading class of nonhormonal therapeutic targets that have been validated in preclinical models of endometriosis and in a Phase 1/2 clinical trial. Despite their therapeutic potential, JNK inhibitors with increased potency and specificity are needed to address the inflammatory pathology of endometriosis and to prevent disease progression. Leveraging a DNA-encoded chemical library collection of ~4 billion compounds, we identified lead inhibitor CDD-2428 and optimized derivatives, CDD-2728 and CDD-3013, with excellent binding affinity to JNK1-3 (K d = 0.12 to 3.7 nM), enhanced selectivity, metabolic stability, and cellular permeability. Crystallographic and biochemical studies confirmed that CDD-3013 exhibited superior kinase selectivity with improved efficacy compared to existing JNK inhibitors. In primary endometriosis cell models, CDD-2728 and CDD-3013 suppressed JNK-dependent inflammatory signaling, dampening pathways linked to pain, invasion, angiogenesis, and macrophage recruitment. In an endometriosis mouse model, both CDD-2728 and CDD-3013 reduced endometriotic lesion size, macrophage infiltration, and cellular proliferation, showing in vivo efficacy. When tested in a lipopolysaccharide-induced hyperalgesia model, CDD-2728 and CDD-3013 decreased markers of induced pain, as measured by changes in a dynamic weight bearing test and Grimace scores. These findings nominate CDD-2728 and CDD-3013 as potent, nonhormonal therapeutic candidates for endometriosis with broad anti-inflammatory and analgesic activity, addressing a critical unmet clinical need.
Photovoltaic (PV) technology is becoming one the best options for supplying electricity to rural communities far from electrical networks and which have a small and disperse demand for electricity. As the cost of the technology goes down and its development advances, opportunities for applying it continue to grow. As a result, in the near future we will probably see an increase in massive application programs of this technology in rural Mexico. This document presents some of the most relevant problems needing immediate solution to increase the possibility of success in establishing photovoltaic programs for rural electrification in Mexico. These problems are influenced by economic, technological, engineering, infrastructural, social and political issues. The paper presents the requirements for an industrial center based on PV technology, the accessibility of replacement parts and maintenance service, development of financial solutions, training of the users and introducing norms and technical regulations. The document summarizes the issue of rural electrification in Mexico, emphasizing the low population density in these areas. A brief description is given of photovoltaics showing different configurations that can be utilized for supplying electricity to the rural areas. The issues involved and recommendations for introducing PV systems to the rural area are described.
Aims.Traditional star-galaxy classification techniques often rely on feature estimation from catalogs, a process susceptible to introducing inaccuracies, thereby potentially jeopardizing the classification’s reliability. Certain galaxies, especially those not manifesting as extended sources, can be misclassified when their shape parameters and flux solely drive the inference. We aim to create a robust and accurate classification network for identifying stars and galaxies directly from astronomical images. Methods.The AutoSourceID-Classifier (ASID-C) algorithm developed for this work uses 32x32 pixel single filter band source cutouts generated by the previously developed AutoSourceID-Light (ASID-L) code. By leveraging convolutional neural networks (CNN) and additional information about the source position within the full-field image, ASID-C aims to accurately classify all stars and galaxies within a survey. Subsequently, we employed a modified Platt scaling calibration for the output of the CNN, ensuring that the derived probabilities were effectively calibrated, delivering precise and reliable results. Results.We show that ASID-C, trained on MeerLICHT telescope images and using the Dark Energy Camera Legacy Survey (DECaLS) morphological classification, is a robust classifier and outperforms similar codes such as SourceExtractor. To facilitate a rigorous comparison, we also trained an eXtreme Gradient Boosting (XGBoost) model on tabular features extracted by SourceExtractor. While this XGBoost model approaches ASID-C in performance metrics, it does not offer the computational efficiency and reduced error propagation inherent in ASID-C’s direct image-based classification approach. ASID-C excels in low signal-to-noise ratio and crowded scenarios, potentially aiding in transient host identification and advancing deep-sky astronomy.
Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 259 Fifteenth Water Reactor Safety Information Meeting by E. G. Silver; CONTROL AND INSTRUMENTATION: 284 Reliability Technology to Improve and/or Maintain Emergency Diesel Generator Performance by S. Karimian and J. H. Taylor, 293 A Noise Diagnostics System for Operator Advice by G. Hessel, P. Liewers, P. Schumann, W. Schmitt, and F.-P. Weiss; PLANT SAFETY FEATURES: 307 A Passive Containment System for Advanced Light-Water Reactors by O. B. Falls, Jr., and F. W. Kleimola; ENVIRONMENTAL EFFECTS: 318 Data Base Construction for a Computerized Radiological Risk Investigation System by L. M. Hively, J. E. Nyquist, J. L. Bledsoe, and A. L. Sjoreen, 326 Erratum to "Radiation Hormesis and Nuclear Safety," Vol. 29, No. 1; OPERATING EXPERIENCES: 327 Operational Safety Experience and Passive Safety Testing at the Fast Flux Text Facility by Q. L. Baird, J. L. Rathbun, D. D. Stepnewski, R. L. Stover, and A. E. Waltar, 344 Backfilling of Independent Residual Heat Removal Systems in West Germany and Switzerland by G. Eckert and Y. Salomon, 353 Reactor Shutdown Experience Compiled by J. W. Cletcher, 356 Selected Safety-Related Events Compiled by G. A. Murphy, 363 Operating U.S. Power Reactors Compiled by E. G. Silver; RECENT DEVELOPMENTS: 384 General Administrative Activities Compiled by E. G. Silver, 390 Reports, Standards, and Safety Guides by D. S. Queener, 395 Status of Power-Reactor Projects Undergoing Licensing Review Compiled by E. G. Silver, 400 Proposed Rule Changes as of Mar. 31,1988; ANNOUNCEMENTS: 283 International ENS/ANS Conference on Thermal Reactor Safety "NUCSAFE 88", 317 Northwestern University Short Course on Radiation Safety, 407 Second International Seminar on Small- and Medium-Sized Nuclear Reactors, 407 International Workshop on New Developments in Occupational Dose Control and ALARA Implementation at Nuclear Power Plants and Similar Facilities, 408 Fourth International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-4), 404 The Authors.
Here, a modification to the di-homodyne transient grating spectroscopy optical arrangement is presented that removes the need to individually align two spatially separated probe laser beams. This work details the novel application of a single probe beam that utilizes birefringent materials to produce two optically homodyned signals with a relative phase shift of π radians. This arrangement effectively simplifies the alignment to one probe beam and removes the relative phase shift ambiguity between each homodyned signal. Several example measurements for tungsten, titanium, molybdenum, and silicon are shown to illustrate the utility of the new optical system.
Abstract not provided.
Abstract not provided.