Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

CHARACTERIZATION OF RADIOACTIVITY IN THE REACTOR VESSEL OF THE HEAVY WATER COMPONENT TEST REACTOR

The Heavy Water Component Test Reactor (HWCTR) facility is a pressurized heavy water reactor that was used to test candidate fuel designs for heavy water power reactors. The reactor operated at nominal power of 50 MW{sub th}. The reactor coolant loop operated at 1200 psig and 250 C. Two isolated test loop were designed into the reactor to provide special test conditions. Fig. 1 shows a cut-away view of the reactor. The two loops are contained in four inch diameter stainless steel piping. The HWCTR was operated for only a short duration, from March 1962 to December 1964 in order to test the viability of test fuel elements and other reactor components for use in a heavy water power reactor. The reactor achieved 13,882 MWd of total power while testing 36 different fuel assemblies. In the course of operation, HWCTR experienced the cladding failures of 10 separate test fuel assemblies. In each case, the cladding was breached with some release of fuel core material into the isolated test loop, causing fission product and actinide contamination in the main coolant loop and the liquid and boiling test loops. Despite the contribution of the contamination from the failed fuel, the primary source of radioactivity in the HWCTR vessel and internals is the activation products in the thermal shields, and to a lesser degree, activation products in the reactor vessel walls and liner. A detailed facility characterization report of the HWCTR facility was completed in 1996. Many of the inputs and assumptions in the 1996 characterization report were derived from the HWCTR decommissioning plan published in 1975. The current paper provides an updated assessment of the radioisotopic characteristics of the HWCTR vessel and internals to support decommissioning activities on the facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Coal direct chemical looping process: 250 kW pilot-scale testing for power generation and carbon capture

Chemical looping combustion (CLC) is an energy conversion technology that can produce concentrated CO 2 stream without the need for a gas separation step, and thus, has the potential to drastically reduce the energy consumption and cost associated with CO 2 capture in power generation. The coal-direct chemical looping (CDCL) process is a CLC technology that uses a moving bed reducer configuration that can directly consume coal as a feedstock without requiring an upstream gasification step. An integrated 250 kW th CDCL pilot unit using iron-based oxygen carriers was constructed and demonstrated for over 1000 h of testing. The principles for the CDCL pilot unit design and operation are summarized in this article. During the 288-hour continuous operation testing, the CDCL pilot unit achieved >96% coal conversion with a CO 2 purity of >97%. Low carbon carryover into the combustor, i.e. <2%, was also confirmed during the test, which shows the capability of the moving bed reactor to retain and convert coal using the oxygen available on the iron-based oxygen carrier. The results from the pilot unit testing confirms the CDCL concept as a promising coal combustion technology for heat and power generation with CO 2 capture.

10 SYNTHETIC FUELS↗

SPATIAL SEISMOLOGY OF A LARGE CORONAL LOOP ARCADE FROM TRACE AND EIT OBSERVATIONS OF ITS TRANSVERSE OSCILLATIONS

We present a study of transverse loop oscillations in a large coronal loop arcade, using observations from the Transition Region And Coronal Explorer (TRACE) and Extreme-ultraviolet Imaging Telescope (EIT). For the first time we reveal the presence of long-period transverse oscillations with periods between 24 minutes and 3 hr. One loop bundle, 690 Mm long and with an oscillation period of 40 minutes, is analyzed in detail and its oscillation characteristics are determined in an automated manner. The oscillation quality factor is similar to what has been found earlier for oscillations in much shorter loops. This indicates that the damping mechanism of transverse loop oscillations is independent of loop length or period. The displacement profile along the whole length of the oscillating loop is determined for the first time and consistently between TRACE and EIT. By comparing the observed profile with models of the three-dimensional geometry of the equilibrium and perturbed loop, we test the effect of longitudinal structuring (spatial seismology) and find that the observations cannot unambiguously distinguish between structuring and non-planarity of the equilibrium loop. Associated intensity variations with a similar periodicity are explained in terms of variations in the line-of-sight column depth. Also, we report intensity oscillations at the loop footpoint, which are in anti-phase with respect to the intensity oscillations in the loop body. Lastly, this observation offers the first opportunity to use the transverse oscillations of the arcade to model the Alfven speed profile in the global corona.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments for MSRs

This report serves as the deliverable for Milestone M3RS-23AN0401061 that is part of Work Package RS-23AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone was to determine performance of the flow enhanced electrochemical sensor (FEES) and modular flow instrumentation testbed (MFIT) in safeguards relevant scenarios. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. To further improve this capability, in FY23 we undertook a campaign of safeguards relevant scenarios in molten salt containing a range of uranium chloride concentrations (0 to 3 wt%). All the testing carried out in FY23 was aided by a control system designed to automatically actuate flow conditions and collect data. This new automation system is estimated to have increased experimental throughput by a factor of four and enabled testing in a variety of complex conditions. The advancements in throughput and repeatability led to improved quantification of actinide concentrations using the in-flow sensors, with a reduction of the mean absolute relative error from 5.6% in FY22 to 3.1% in FY23. In addition to safeguards scenarios run in the MFIT, FY23 work included deployment of a FEES at a partner institution where it will be tested in a flowing salt loop. The FEES was successfully integrated into that loop and is being tested prior to loop startup. In FY23, work also continued on the smaller flow system that we have named the mini-MFIT. This smaller system is capable of rapid prototyping of new sensor designs prior to installation in the larger MFIT radiological flow system. Work was carried out to test this new system in non-radiological molten salts in a separate glovebox. This work is helping us to enhance the accuracy of our salt monitoring capabilities through the integration of multiple types of sensors. The high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will be needed to further push the measurement accuracy to the needed level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SRF cavity testing using a FPGA Self Excited Loop

Various authors have previously studied the theory and practice of cavity testing, notably an extensive treatment by Powers [1] and Padamsee [2]. The advent of the digital Low Level RF (LLRF) electronics based on Field Programmable Logic Arrays (FPGA) provides various improvements over the rather complex systems used in the past as well as enabling new measurement techniques.In this document we reintroduce a technique that seems to have fallen out of practice in recent times, that is obtaining the coupling constant β through measurements from just one port, the reflected power port, of the directional coupler placed in front of the cavity.

43 PARTICLE ACCELERATORS↗

The magnetic flywheel flow meter: Theoretical and experimental contributions

The development of contactless flow meters is an important issue for monitoring and controlling of processes in different application fields, like metallurgy, liquid metal casting, or cooling systems for nuclear reactors and transmutation machines. Shercliff described in his book “The Theory of Electromagnetic Flow Measurement, Cambridge University Press, 1962” a simple and robust device for contact-less measurements of liquid metal flow rates which is known as magnetic flywheel. The sensor consists of several permanent magnets attached on a rotatable soft iron plate. This arrangement will be placed closely to the liquid metal flow to be measured, so that the field of the permanent magnets penetrates into the fluid volume. The flywheel will be accelerated by a Lorentz force arising from the interaction between the magnetic field and the moving liquid. Steady rotation rates of the flywheel can be taken as a measure for the mean flow rate inside the fluid channel. The present paper provides a detailed theoretical description of the sensor in order to gain a better insight into the functional principle of the magnetic flywheel. Theoretical predictions are confirmed by corresponding laboratory experiments. For that purpose, a laboratory model of such a flow meter was built and tested on a GaInSn-loop under various test conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of Prototypic and Closed Loop Operation during Pulse Jet Mixer Tests with Non-Cohesive Solids to Develop Scale-up Relationships

Scaled tests were conducted to develop correlations describing pulse jet mixer (PJM) performance with non-cohesive solids in water. These correlations were developed in scaled test systems that incorporated certain simplified aspects including non-prototypic refill associated with closed-loop operation of the mixing jets. When this test data was compared with experiments that used prototypic PJM refill, a difference in the critical suspension velocity (UCS) was identified. The non-prototypic aspects of the initial testing were reviewed and assessed. The effects of non-prototypic refill associated with the closed loop operation of the jets, previously known to affect solids cloud height, can be described in terms of a modified settling velocity. When the modified settling velocity is incorporated into the physical model, the adjusted new physical model does a better job of predicting UCS results for prototypic PJM refill tests. The adjusted new physical model was bench-marked with data taken during three prototypic drive tests with a mono-disperse simulant, a 3-part medium distribution stimulant and a 5-part broad distribution simulant The applicability of the non-prototypic scale-up behavior to prototypic testing was analyzed. The effects of non-prototypic refill caused measured values of UCS to be somewhat reduced at larger scales. Hence the scale-up exponents for the non-prototypic drive tests are believed to be smaller than they would have been had there been prototypic refill. Estimated scale-up exponents for the prototypic testing were developed for 8 and 12 pulse tube configurations.

comparison between prototypic and simplified drive↗

1.2.4.404 - Data-Driven Approach for Hydropower Plant Controller Prototyping Using Remote Hardware in the Loop (DR-HIL)

Real-time prototyping of hydropower plant controls is important for reducing the cost and the risk of field deployment. This project will 1) collect design and operational data from actual hydro plants and 2) use a physics-informed machine learning approach for real-time emulation of hydropower plants, including hydro turbine and hydrodynamics. The data-driven models will be interfaced with digital real-time simulation at NREL’s Flatirons campus for hardware-in-the-loop (HIL) testing of the governor hardware device or controller-HIL (CHIL). The proposed approach will also establish the connectivity based remote CHIL testing capability using real-time data streams from an actual hydro plant. This integrated hydro-plant emulation with CHIL will be used to prototype hydro-governor controls and eventually provide an opportunity to test hydropower integrated with various technologies (e.g. conventional and renewable generation, energy conversion, etc.) as HIL.

controls prototyping↗

Integrated Oxygen Production and CO 2 Separation through Chemical Looping Combustion with Oxygen Uncoupling (Final Report)

The project "Integrated Oxygen Production and CO 2 Separation through Chemical Looping Combustion with Oxygen Uncoupling" focused on advancing fluidized bed chemical looping combustion technology to semi-pilot scale. An important aspect of technology scale-up is production of well-performing oxygen carrier materials economically and at a scale sufficient for industrial-scale systems. Under this program, a new technique for oxygen carrier production was developed and a prototype system capable of producing up to 150 lb per batch of oxygen carrier was constructed. Chemical looping combustion testing was performed in a large process development unit designed for operation at more than 200 kW using coal as fuel. Complementary evaluation of carbon conversion pathways was conducted and quantitative analysis of the fate of carbon in a CLOU-based chemical looping system was performed. As an aid for design, optimization, troubleshooting and scale-up, robust CFD models for fluidized bed chemical looping combustion systems were developed.

01 COAL, LIGNITE, AND PEAT↗

Developing Separate Effects Transient Test Experiments Using an Out-of-Pile Flowing Water Loop

In 2017 the Transient Reactor Test Facility was restarted after being placed in a standby state since 1994. This Test Reactor’s restart has since enabled the progressive development of new nuclear technologies within the U.S. that were previously required to outsource to other countries. While the reactor’s restart was a large feat worthy of recognition, the experimental use of its characteristics has required the further development of in-pile experimental infrastructure sufficient to support programmatic needs. This hardware have taken the form of capsule designs (compact and elongated) as well as loop concepts representing the phenomena of interest for a subset of separate effects tests desire for each respective testing campaign. The Transient Testing Program has a large-integrated effort that aligns with the U.S. Department of Energy’s current needs. This study compliments those programmatic elements by developing, fabricating and demonstrating a full-scale flowing water loop in an out-of-pile environment. The goal of this effort is to develop a pragmatic understanding of the engineering capabilities and limitations associated with geometric form-factors, metering technology, and controls logic under representative thermal hydraulic conditions that would be experienced within the TREAT reactor during an in-pile reactivity initiated accident test. The outcomes of this study result in an evaluation of the conceptual design of a comprehensive flowing water loop including objective figures of merit (FoMs) for comparing unique instrumentation and the basis for their selection during operations. These efforts directly contribute to and are required for the further advancement of transient testing capabilities within the U.S.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-Ever Polymer Flood Pilot on Alaska North Slope

Mineral fouling in heat exchangers has been extensively investigated by researchers in recent times. The oil and gas industry has a long history of fouling issues in production systems as a result of produced fluids treatment. Due to decline in production rates in oilfields new technologies are being developed and field tested in pilots. Polymer flooding is one such technology that involves addition of polymers to injection fluids to enhance oil production. A polymer flood pilot has been set up in the Schrader Bluff viscous oil reservoir at Milne Point field on the Alaska North Slope (ANS). The results from the pilot are encouraging, however a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. This work applies a multi-experimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids as well as studying the stability of polymer solutions at different temperatures. A unique experimental setup was designed and developed in-house to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Each test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution was heated from 77°F to 122°F to mimic field-operating conditions. The heating time and fouling amount were recorded for each run. Dynamic Scale Loop (DSL) tests were conducted to study fouling due to polymer at different temperatures (165°F to 350°F) in a dynamic state of fluid flow where the fluids mimic the residence time of fluids in the heat exchanger on the field pilot. Cloud point measurement has also been conducted to find the critical temperature at which the polymer in solution becomes unstable and precipitates out. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It was found that the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless-steel surfaces at all tested skin temperatures. Only higher skin temperatures of 250°F and 350°F could cause polymer-induced fouling issues on the copper tube surface, and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer-induced fouling would not occur, and only mineral scale was deposited but above which the polymer would aggravate the fouling issue. The cloud point of the tested polymer solution was determined to be between 220°F and 230°F. In the DSL tests it was found that at higher skin temperatures of 250°F and 350°F tube blocking was observed in the DSL tests whereas the tests at 165°F and 200°F did not show any tube blocking in the same time period. These experiments also manifested the influence of cloud point of the solution as deposit rate increased significantly in both carbon steel and stainless-steel tubes when the skin temperature was higher than the solution cloud point. The results of this study have provided guidance to the operator for the field-operations.

Dhaliwal, Anshul↗

Hydrogen Production, Grid Integration, and Scaling for the Future

The Hydrogen Production, Grid Integration, and Scaling for the Future project will inform clean hydrogen production deployment across the planning, procurement, and operation stages of hydrogen production on the grid. Hydrogen production from renewables is a clean source of fuel which is near zero for greenhouse gas emissions and criteria pollutants. The results from this project will inform entities looking to build clean energy projects that produce good paying jobs in manufacturing, installation, maintenance and operation of these facilities. This project provides system characterization examples, multiple configurations, optimizations, and suggested metering and custody transfer points through multiple scenarios and hardware testing of NREL's state-of-the-art 1.25 MW polymer electrolyte membrane (PEM) electrolyzer system to characterize system performance in relevant scenarios. This work also creates a digital twin for emulation in the Advanced Research on Integrated Systems (ARIES) virtual environment and performs hardware-in-the-loop (HIL) testing of pilot-scale, decentralized, and centralized hydrogen systems.

centralized hydrogen production↗

Performance of a Thermally Stable Polyaromatic Hydrocarbon in a Simulated Concentrating Solar Power Loop

Polyaromatic hydrocarbon thermal fluids showing thermally stability to 600 C have been tested for solar thermal-power applications. Although static thermal tests showed promising results for 1-phenylnaphthalene, loop testing at temperatures to 450 C indicated that the fluid isomerized and degraded at a slow rate. In a loop with a temperature high enough to drive the isomerization, the higher melting point byproducts tended to condense onto cooler surfaces. So, as experienced in loop operation, eventually the internal channels of cooler components in trough solar electric generating systems, such as the waste heat rejection exchanger, may become coated or clogged affecting loop performance. Thus, pure 1-phenylnaphthalene, without addition of stabilizers, does not appear to be a fluid that would have a sufficiently long lifetime (years to decades) to be used in a loop at the temperatures greater than 500 C. The performance of a concentrating solar loop using high temperature fluids was modeled based on the National Renewable Laboratory Solar Advisory Model. It was determined that a solar-to-electricity efficiency of up to 30% and a capacity factor of near 60% could be achieved using a high efficiency collector and 12 h thermal energy storage.

concentrating solar power↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

controller hardware-in-the-loop↗

System-of-Systems Approach for Integrated Energy Systems Modeling and Simulation: Preprint

Today’s electricity grid is the most complex system ever built—and the future grid is likely to be even more complex because it will incorporate distributed energy resources (DERs) such as wind, solar, and various other sources of generation and energy storage. The complexity is further augmented by the possible evolution to new retail market structures that provide incentives to owners of DERs to support the grid. To understand and test new retail market structures and technologies such as DERs, demand-response equipment, and energy management systems while providing reliable electricity to all customers, an Integrated Energy System Model (IESM) is being developed at NREL. The IESM is composed of a power flow simulator (GridLAB-D), home energy management systems implemented using GAMS/Pyomo, a market layer, and hardware-in-the-loop simulation (testing appliances such as HVAC, dishwasher, etc.). The IESM is a system-of-systems (SoS) simulator wherein the constituent systems are brought together in a virtual testbed. We will describe an SoS approach for developing a distributed simulation environment. We will elaborate on the methodology and the control mechanisms used in the co-simulation illustrated by a case study.

97 MATHEMATICS AND COMPUTING↗

SRF Cavity Testing Using a FPGA Self Excited Loop

This document provides a detailed description of procedures for very-high precision calibration and testing of superconducting RF cavities using digital Low-Level RF (LLRF) electronics based on Field Programmable Gate Arrays (FPGA). The use of a Self-Excited Loop with an innovative procedure for fast turn-on allows the measurement of the forward, reflected and transmitted power from a single port of the directional coupler in front of the cavity, thus eliminating certain measurement errors. Various procedures for measuring the quality factor as a function of cavity fields are described, including a single RF pulse technique. Errors are estimated for the measurements.

43 PARTICLE ACCELERATORS↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Embedded Sensors and Controls to Improve Component Performance and Reliability -- Loop-scale Testbed Design Report

Embedded instrumentation and control systems that can operate in extreme environments are challenging to design and operate. Extreme environments limit the options for sensors and actuators and degrade their performance. Because sensors and actuators are necessary for feedback control, these limitations mean that designing embedded instrumentation and control systems for the challenging environments of nuclear reactors requires advanced technical solutions that are not available commercially. This report details the development of testbed that will be used for cross-cutting embedded instrumentation and control research for nuclear power applications. This research is funded by the Department of Energy's Nuclear Energy Enabling Technology program's Advanced Sensors and Instrumentation topic. The design goal of the loop-scale testbed is to build a low temperature pump that utilizes magnetic bearing that will be incorporated into a water loop to test control system performance and self-sensing techniques. Specifically, this testbed will be used to analyze control system performance in response to nonlinear and cross-coupling fluid effects between the shaft axes of motion, rotordynamics and gyroscopic effects, and impeller disturbances. This testbed will also be used to characterize the performance losses when using self-sensing position measurement techniques. Active magnetic bearings are a technology that can reduce failures and maintenance costs in nuclear power plants. They are particularly relevant to liquid salt reactors that operate at high temperatures (700 C). Pumps used in the extreme environment of liquid salt reactors provide many engineering challenges that can be overcome with magnetic bearings and their associated embedded instrumentation and control. This report will give details of the mechanical design and electromagnetic design of the loop-scale embedded instrumentation and control testbed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗