Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Characterization and Analysis of InGaAsSb Detectors

Profiling of atmospheric CO2 at 2 micron wavelength using the LIDAR technique, has recently gained interest. Although several detectors might be suitable for this application, an ideal device would have high gain, low noise and narrow spectral response peaking around the wavelength of interest. This increases the detector signal-to-noise ratio and minimizes the background signal, thereby increasing the device sensitivity and dynamic range. Detectors meeting the above idealized criteria are commercially unavailable for this particular wavelength. In this paper, the characterization and analysis of Sb-based detectors for 2 micron lidar applications are presented. The detectors were manufactured by AstroPower, Inc., with an InGaAsSb absorbing layer and AlGaAsSb passivating layer. The characterization experiments included spectral response, current versus voltage and noise measurements. The effect of the detectors bias voltage and temperature on its performance, have been investigated as well. The detectors peak responsivity is located at the 2 micron wavelength. Comparing three detector samples, an optimization of the spectral response around the 2 micron wavelength, through a narrower spectral period was observed. Increasing the detector bias voltage enhances the device gain at the narrow spectral range, while cooling the device reduces the cut-off wavelength and lowers its noise. Noise-equivalent-power analysis results in a value as low as 4 x 10(exp -12) W/Hz(exp 1/2) corresponding to D* of 1 x 10(exp 10) cmHz(exp 1/2)/W, at -1 V and 20 C. Discussions also include device operational physics and optimization guidelines, taking into account peculiarity of the Type II heterointerface and transport mechanisms under these conditions.

Abedin, M. Nurul↗

Performance Assessment of Photovoltaic Panels Using Impedance Spectroscopy

The goal of this project was to develop a technique for measuring internal characteristics of a PV module using light modulation under a fixed voltage bias while measuring the resulting alternating current. This technique, light-intensity modulated impedance spectroscopy (LIMIS), has the promise of detecting early signs of panel aging and degradation that could be used for example by solar farm operators to have early warnings to repair or replace panels to maintain reliability of the overall PV array. LIMIS would be complementary with the previously developed electrochemical impedance spectroscopy (EIS), which uses an alternating voltage applied electrically to a solar cell with a similar alternating current measurement. EIS has mostly been developed for individual PV cells rather than whole modules. The project was intended to assess what different information could be revealed by LIMIS, which may in some cases be more scalable to larger modules and potentially more practical to apply in field measurements without needing to electrically disconnect PV modules. We began with small 10 W PV modules and built a testbed capable of oscillating the light intensity with frequencies up to 50 kHz. In parallel, we built a large testbed for testing large 250 W PV modules. Meanwhile, we developed procedures for established measurement techniques: current–voltage (I–V), EIS, and electroluminescence (EL) imaging, where panels are subjected to forward bias while their infrared emission is recorded using a camera modified to be sensitive to IR wavelengths. In addition, we developed protocols for accelerated aging of PV modules in two ways. Thermal cycling from –40°C to +90°C simulates the diurnal temperature cycles on a rooftop. Mechanical stress by dropping a 227 g ball from a height of 1 m simulates damage such as that due to hail impacts.

14 SOLAR ENERGY↗

Voltage Service Limits Smart Contract Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Generator

Modern electrical grids face growing stability risks from customer-owned generators, especially at points of common couplings (PCCs). Disruptive behavior from power-electronic sources can cause protective relays to isolate problematic generators, making measurement integrity critical. This article presents a distributed ledger technology (DLT) approach that uses smart contracts to evaluate PCC voltage measurements and trigger backup breaker operations. The approach is framed as a verifiable, multi-organization attestation and audit layer, not as a real-time control security mechanism. In the proposed architecture, voltage measurements from a hardware protective relay are anchored on a DLT through the Cyber Grid Guard (CGG) system for attestation by both the grid utility and customer-owned generator. A Voltage Service Limits (VSLs) smart contract evaluates the on-chain measurements against allowable phase-voltage limits derived from the ANSI C84.1 standard. The framework is validated in a hardware-relay-in-the-loop test bed under sustained-undervoltage, sustained-overvoltage, and transient line-to-line fault scenarios. The results show that the VSL smart contract can process these measurements and issue backup breaker actions consistent with the defined service-limit criteria, demonstrating the DLT potential as a verifiable audit layer at the PCC that complements primary protection.

cyber security↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops a machine learning based approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurement. The machine learning model is developed by using random forest algorithm. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

advanced metering infrastructure↗

High-Speed and High-Power Ferroelectric Switching Current Measurement Instrument for Materials with Large Coercive Voltage and Remanent Polarization

A high-speed and high-power current measurement instrument is described for measuring rapid switching of ferroelectric samples with large spontaneous polarization and coercive field. Instrument capabilities (±200 V, 200 mA, and 200 ns order response) are validated with a LiTaO 3 single crystal whose switching kinetics are well known. The new instrument described here enables measurements that are not possible using existing commercial measurement systems, including the observation of ferroelectric switching in large coercive field and large spontaneous polarization Al 0.7 Sc 0.3 N thin films.

30 DIRECT ENERGY CONVERSION↗

SPEAR-1: An experiment to measure current collection in the ionosphere by high voltage biased conductors

An experiment is described in which a high electrical potential difference, up to 45 kV, was applied between deployed conducting spheres and a sounding rocket in the ionosphere. Measurements were made of the applied voltage and the resulting currents for each of 24 applications of different high potentials. In addition, diagnostic measurements of optical emissions in the vicinity of the spheres, energetic particle flow to the sounding rocket, dc electric field and wave data were made. The ambient plasma and neutral environments were measured by a Langmuir probe and a cold cathode neutral ionization gauge, respectively. The payload is described and examples of the measured current and voltage characteristics are presented. The characteristics of the measured currents are discussed in terms of the diagnostic measurements and the in-situ measurements of the vehicle environment. In general, it was found that the currents observed were at a level typical of magnetically limited currents from the ionospheric plasma for potentials less than 12 kV, and slightly higher for larger potentials. However, due to the failure to expose the plasma contactor, the vehicle sheath modified the sphere sheaths and made comparisons with the analytic models of Langmuir-Blodgett and Parker-Murphy less meaningful. Examples of localized enhancements of ambient gas density resulting from the operation of the attitude control system thrusters (cold nitrogen) were obtained. Current measurements and optical data indicated localized discharges due to enhanced gas density that reduced the vehicle-ionosphere impedance.

Raitt, W. John↗

Voltage-To-Frequency Converter For Pressure Calibration

Measurements of pressures on walls of wind tunnels and on surfaces of models in wind tunnels made with help of electronically scanned pressure-measurement (ESP) system. Voltage-to-frequency converter circuit, designed to convert 0- to 5-Vdc analog output voltage from high-line-pressure, low-differential-pressure standard to required frequency range. Enables selection of wider variety of high-accuracy pressure standards to enhance accuracy of measurement of ESP instrumentation while requiring little modification of manufacturer's system and no modification of operating software of system. Useful primarily in wind-tunnel instrumentation and readily adaptable to commercial instruments currently in use.

Sealey, Bradley S.↗

Extended real-time voltage instability identification method based on synchronized phasor measurements

This paper presents an extended adaptive approach designed to accurately estimate the Thévenin equivalent parameters using phasor measurements at a given bus for measurements lying in any of four quadrants of the PQ-plane. The improvement is achieved by using a new condition to properly update the estimated parameters after an initial guess. Based on an adaptive philosophy, the proposed approach can correctly account for the intrinsic nonlinearities of a power system, can provide a real-time estimation of Thévenin parameters, and does not require network topology knowledge. The method is validated using the Kundur 2-area system, showing estimation improvements compared to the current adaptive approach and the classical recursive least-squares method. The proposed approach is able to estimate both sides of the system with respect to the measurement bus. In addition, a data-driven voltage stability index is developed. To illustrate the performance of the proposed approach in a larger power system, a voltage stability assessment is carried out on the IEEE 39-bus system, considering the action of overexcitation limiters of generators and nonlinear loads. The proposed approach is suitable for applications that require an accurate Thévenin equivalent estimation in real-time, such as for voltage stability assessment. The new approach provides a reliable tool for the system operators to make proper and timely decisions.

42 ENGINEERING↗

Isolation Amplifier Based On Sigma-Delta Modulation

Improved isolation amplifier transmits dc or low-frequency analog signal by use of digital pulses. Relatively imprecise digital pulses convey analog signal with relatively high precision. Amplifier implements sigma-delta modulation scheme. Circuit used wherever conventional amplifier needed. Includes medical instrumentation, switching-type power supplies, and other applications in which input voltages must be measured in presence of large common-mode voltages.

Harres, Daniel N.↗

Electropotential Verification for Nuclear Safeguards

The international safeguards regime desires methods to efficiently verify that facilities are only performing declared activities. Electropotential verification (EPV) is a newly proposed technique that was tested for its feasibility to perform facility design information verification (DIV) and verification of spent nuclear fuel while in a cooling pool. EPV works by passing a constant, low voltage current through a conductive system (facility infrastructure of nuclear fuel assembly) and measuring the resulting voltage at various places throughout the infrastructure in order to establish a baseline. Changes made to the system affect these voltage readings, which will deviate from the baseline and indicate that a change to the system was made. For facility DIV, it appears feasible that changes in configuration of the system’s grounding can be detected in real-time, and the location of the change can be inferred from the measured intensity of the change in voltage. Determination of whether or not spent fuel was present in a fuel rod, as well as the presence/absence of a fuel rod from an assembly using EPV, proved unsuccessful with the sensitivity of instrumentation used in this study.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electropotential Verification for Nuclear Safeguards

The international safeguards regime desires methods to efficiently verify that facilities are only performing declared activities. Electropotential verification (EPV) is a newly proposed technique that was tested for its feasibility to perform facility design information verification (DIV). EPV works by passing a constant, low voltage current through a conductive system (facility infrastructure of nuclear fuel assembly) and measuring the resulting voltage at various places throughout the infrastructure in order to establish a baseline. Changes made to the system affect these voltage readings, which will deviate from the baseline and indicate that a change to the system was made. For large scale infrastructure such as a nuclear facility DIV, it appears feasible that changes in configuration of the system’s grounding can be detected in real-time, and the location of the change can be inferred from the measured intensity of the change in voltage.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Conductivity effects in high-voltage spacecraft insulating materials

Laboratory measurements were performed to assess the influence of various external parameters on the conductivity properties of several typical and potential spacecraft insulating materials in a simulated space environment. The materials tested include Kapton, Teflon, quartz, and polyvinylidene fluoride. The parameters measured comprise sample thickness, temperature, applied voltage, illumination intensity and wavelength, and electron beam energy and current density. All tests were conducted in a vacuum chamber at a pressure of about one millionth Torr both with conventional optically-transparent gold front-surface electrodes and with the front surfaces of the test samples exposed directly to an electron beam. The data presented illustrate some of the complexities in electrical characteristics exhibited by the materials as a result of interactions with various conditions of their environment.

Adamo, R. C.↗

Improved Control of Charging Voltage for Li-Ion Battery

The protocol for charging a lithium-ion battery would be modified, according to a proposal, to compensate for the internal voltage drop (charging current internal resistance of the battery). The essence of the modification is to provide for measurement of the internal voltage drop and to increase the terminal-voltage setting by the amount of the internal voltage drop. Ordinarily, a lithium-ion battery is charged at constant current until its terminal voltage attains a set value equal to the nominal full-charge potential. The set value is chosen carefully so as not to exceed the lithium-plating potential, because plated lithium in metallic form constitutes a hazard. When the battery is charged at low temperature, the internal voltage drop is considerable because the electrical conductivity of the battery electrolyte is low at low temperature. Charging the battery at high current at any temperature also gives rise to a high internal voltage drop. In some cases, the internal voltage drop can be as high as 1 volt per cell. Because the voltage available for charging is less than the terminal voltage by the amount of the internal voltage drop, the battery is not fully charged (see figure), even when the terminal voltage reaches the set value. In the modified protocol, the charging current would be periodically interrupted so that the zero-current battery-terminal voltage indicative of the state of charge could be measured. The terminal voltage would also be measured at full charging current. The difference between the full-current and zero-current voltages would equal the internal voltage drop. The set value of terminal voltage would then be increased beyond the nominal full-charge potential by the amount of the internal voltage drop. This adjustment would be performed repeatedly, in real time, so that the voltage setting would track variations in the internal voltage drop to afford full charge without risk of lithium plating. If the charging current and voltage settings were controlled by a computer, then this method of charge control could readily be implemented in software.

Timmerman, Paul↗

A Time-Domain Protection Approach for AC Transmission Systems With Grid-Forming Resources

Ac transmission protection must reliably detect, classify, and locate short-circuit faults from voltage and current measurements. At present, these functionalities, which have been classically engineered using phasors approaches, are being challenged by the dynamic behavior and fault-current limits of converter-based generation. This paper tackles these challenges by engineering a time-domain protection approach that leverages the classical Bergeron model in a new manner. Low- and high-impedance faults are detected and classified by ascertaining how well line voltage and current measurements match the Bergeron equations. Faults are located by posing a novel one-variable optimization problem, whereas voltage and current waveforms at the fault location are estimated by unveiling rigorous relationships. The proposed elements are secure against external faults, measurement errors, and variation of line parameters and sampling time. Furthermore, these advances are tested via electromagnetic transient simulations and are significant to satisfy IEEE and North American Electric Reliability Corporation requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct Phase-Angle Detection for Three-Phase Inverters in Asymmetrical Power Grids

This paper introduces a signal reformation based direct phase-angle detection (DPD-SR) technique for three-phase inverters supporting asymmetrical grids. Asymmetries in three-phase systems may happen because of unbalanced three-phase loads, which can lead to the voltage asymmetry at the terminals of grid-tied inverters. The proposed DPD-SR technique can detect the voltage phase-angle under asymmetrical conditions. The DPD-SR technique also offers precise and rapid phase-angle detection via signal reformation and trigonometric functions. In essence, the phase-angle detection is directly derived from the trigonometric properties of the line-line voltages, while signal reformation is implemented to handle asymmetrical voltages. The proposed method measures two line-line voltages and detects the phase-angle of a three-phase system under both symmetrical and asymmetrical conditions. Unlike classical phase-locked loop (PLL) techniques, DPD-SR does not need any closed-loop PI controller, which significantly reduces the complexity and the delay in detecting the phase-angle. In this paper, the efficacy of the proposed technique is examined in comparison with the state-of-the-art PLLs under asymmetrical conditions via a set of laboratory experiments. Here, the performance of the phase-angle detection is also tested as part of an inverter feeding an asymmetrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measuring Conductor Widths and Spacings Electrically

Widths and spacings of conductor lines on integrated circuits measured electrically by split cross-bridge resistor technique. Speeds evaluation of integrated-circuit fabrication processes. When measurement of probe currents and voltages and reduction of measurement data automated, test structure probed and characterized in less than one second.

Buehler, Martin G.↗

Ferritin-Templated Quantum-Dots for Quantum Logic Gates

Quantum logic gates (QLGs) or other logic systems are based on quantum-dots (QD) with a stringent requirement of size uniformity. The QD are widely known building units for QLGs. The size control of QD is a critical issue in quantum-dot fabrication. The work presented here offers a new method to develop quantum-dots using a bio-template, called ferritin, that ensures QD production in uniform size of nano-scale proportion. The bio-template for uniform yield of QD is based on a ferritin protein that allows reconstitution of core material through the reduction and chelation processes. One of the biggest challenges for developing QLG is the requirement of ordered and uniform size of QD for arrays on a substrate with nanometer precision. The QD development by bio-template includes the electrochemical/chemical reconsitution of ferritins with different core materials, such as iron, cobalt, manganese, platinum, and nickel. The other bio-template method used in our laboratory is dendrimers, precisely defined chemical structures. With ferritin-templated QD, we fabricated the heptagonshaped patterned array via direct nano manipulation of the ferritin molecules with a tip of atomic force microscope (AFM). We also designed various nanofabrication methods of QD arrays using a wide range manipulation techniques. The precise control of the ferritin-templated QD for a patterned arrangement are offered by various methods, such as a site-specific immobilization of thiolated ferritins through local oxidation using the AFM tip, ferritin arrays induced by gold nanoparticle manipulation, thiolated ferritin positioning by shaving method, etc. In the signal measurements, the current-voltage curve is obtained by measuring the current through the ferritin, between the tip and the substrate for potential sweeping or at constant potential. The measured resistance near zero bias was 1.8 teraohm for single holoferritin and 5.7 teraohm for single apoferritin, respectively.

Choi, Sang H.↗

Fiber-optic sensors for aerospace electrical measurements: An update

Fiber-optic sensors are being developed for electrical current, voltage, and power measurements in aerospace applications. These sensors are presently designed to cover ac frequencies from 60 Hz to 20 kHz. The current sensor, based on the Faraday effect in optical fiber, is in advanced development after some initial testing. Concentration is on packaging methods and ways to maintain consistent sensitivity with changes in temperature. The voltage sensor, utilizing the Pockels effect in a crystal, has excelled in temperature tests. This paper reports on the development of these sensors, the results of evaluation, improvements now in progress, and the future direction of the work.

Patterson, Richard L.↗