Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Photon Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Synchrotron Based Microstructural Characterization Method Development for Pu Oxides

Identification of new plutonium oxide signatures is a high priority focus area of the technical nuclear forensics and nonproliferation communities. Comprehensive materials science studies of plutonium oxide are needed to advance the understanding of the microcrystalline properties and their relationship to macro-scale morphologies and signatures. Plutonium oxide particle growth is depenedent on the microcrystalline strucutures, grain size, and orientation. Microcrystalline structures have been found to vary for plutonium oxide based on the oxidation state of plutonium, concentration of reactants, and the physiochemical conditions of precipitation. Empirical observation confirms the relationship between processing conditions and particle morphology. High sensitivity, non destructive analysis of individual microcrystalline grains requires the use of bright sources of X-rays produced by synchrotron radiation, such as those at the Advanced Photon Source. The light source can reveal higher resolution crystallographic mapping, more sensitive chemical analysis, and higher fidelity morphological information than any current methods at SRNL Progress of FY19 was the analysis of the synchrotron data. Areas of focus included XANES oxidation state and EXAFS to measure bond distances with modeling. Most measurements for XANES indicated that the plutonium was in the +4 oxidation state, however, some indicated that there could also be a +5 oxidation state. The EXAFS measurements showed typical Pu – O bonding distance of 2.33 and Pu – Pu bonding distances of 3.81 A; however, some samples also showed that there could be shorter Pu – O distances of approximately 1.81 A, indicative of plutonium in the +5 oxidation state.

36 MATERIALS SCIENCE↗

Containment Chamber Systems Engineering Project

Lawrence Livermore National Laboratory (LLNL) is a leading research laboratory in material properties. The most notable facility at LLNL capable of determining equation of state data for hazardous materials is the National Ignition Facility (NIF). NIF is the most energetic laser in the world and is a very versatile system that allows for a variety of laser configurations and diagnostics. The flexibility that NIF offers makes it an attractive tool for high budget programs researching specific areas of interest. Some programs require many tests to be performed, and although NIF could be an option for performing these tests, the cost and time to perform the tests would not be feasible. Also, many of these tests would underutilize the full capacity of NIF’s lasers, and NIF does not have a dedicated light source suitable for the diagnostic requirement. The needs of these tests do not align with NIF’s capabilities. The physicists are the main stakeholders for the tests, and they require a third-generation light source to meet the desired diagnostic performance. The Dynamic Compression Sector (DCS) within the Advanced Photon Source (APS) at Argonne National Laboratory (ANL) is the facility that will meet necessary laser performance and the X-ray diagnostic performance in order to obtain the desired data. DCS does not have the capability to test hazardous material, and therefore DCS requires a method and hardware for ensuring that no hazardous material is exposed before, during, or after the test. After taking a system engineering evaluation of the need for a solution to perform laser shock experiments on hazardous materials with certain laser and X-ray characteristics, a solution is proposed that meets the requirements of each involved stakeholder. The proposed solution is to contain the targets within sealed vacuum chamber that will meet the protection requirements of each facility. The chamber would be assembled and pumped down at LLNL in facilities that can handle hazardous material. Then, the chamber would be shipped under vacuum to DCS, where the chamber will be inserted into the beam paths. DCS’s laser will enter the sealed chamber and impart a shock into the target of hazardous material while the X-ray will simultaneously image the material. Once each target has been fired, the chamber will be removed from the beam path and shipped to the proper disposal facility.

42 ENGINEERING↗

Workshop to Identify Opportunities in Biological and Environmental Research Uniquely Enabled by the APS Upgrade

The development of synchrotron-based x-ray science has enabled tremendous scientific advances, driven both by discoveries of new fundamental ways to derive insight from the interaction of x-rays with matter and by the evolution of x-ray light sources themselves. Over the last 20-plus years, the U.S. Department of Energy’s (DOE’s) Advanced Photon Source (APS) at Argonne has yielded a multitude of transformational insights into science questions across numerous areas relevant to the biological, geological, geochemical, biogeochemical, and environmental sciences. Recent developments in accelerator technology, particularly the multi-bend achromat lattice, have led to plans to dramatically upgrade the APS, allowing an upgraded APS to offer orders-of-magnitude improvements in key parameters such as coherence and brightness, while retaining high-energy capabilities. These enhanced parameters are directly relevant to almost all hard x-ray imaging, scattering, and spectroscopy experiments (Eriksson et al., 2014). The APS Upgrade Project exceeds the capabilities of today’s synchrotrons by 2 to 3 orders of magnitude in brightness and coherent flux in the hard x-ray range, enabling a transformational range of new probes for the structure, properties, and functionality of matter. With vastly improved coherent flux, nearly all techniques can become microscopies. For example, frontiers inaccessible today will be opened by x-ray instruments that provide three-dimensional (3-D) real-space resolution down to nanometers across, up to millimeters of field of view, providing the ability to follow in real time relevant processes and trace element sensitivity down to a few atoms. In addition to the unprecedented spatial resolution across a large field of view, and with appropriate time resolution, the ability for high-throughput, four-dimension/five-dimension data collection enables unprecedented statistical analysis of complex biological and environmental systems in changing environments.

54 ENVIRONMENTAL SCIENCES↗

Removal of spurious data in Bragg coherent diffraction imaging: an algorithm for automated data preprocessing

Bragg coherent diffraction imaging (BCDI) provides a powerful tool for obtaining high-resolution structural information from nanocrystalline materials. Here a BCDI sample consisting of a large number of randomly oriented nanoscale crystals is considered. Ideally, only one crystal is oriented to produce a Bragg peak on the detector. However, diffraction from other crystals often produces additional signals on the detector. Before the measured diffraction patterns can be processed into structural images, scientists routinely need to manually identify and remove the `alien' intensities from sources other than the intended crystal. With the development of modern high-coherence storage rings, such as the upgraded Advanced Photon Source (APS), the already slow process of manual preprocessing will be untenable for the large volumes of data that will be produced. An automated method of identifying and deleting alien intensities is proposed. This method exploits the fact that BCDI of a perfect crystal produces diffraction data with inversion symmetry around the Bragg peak. This approach uses the machine learning clustering method DBSCAN to distinguish between diffraction from multiple sources, and then calculates cluster size and inversion symmetry to assess whether clusters of intensity belong to desired data or alien signals. This approach can dramatically reduce the amount of time spent manually processing data, allowing BCDI data processing capabilities to keep pace with the technological advances of fourth-generation synchrotron light sources.

36 MATERIALS SCIENCE↗

Optimization of a phase-space beam position and size monitor for low-emittance light sources

The recently developed vertical phase-space beam position and size monitor (ps-BPM) system has proven to be able to measure the electron-source position, angle, size and divergence simultaneously in the vertical plane at a single location of a beamline. The optimization of the ps-BPM system is performed by ray-tracing simulation to maximize the instrument sensitivity and resolution. The contribution of each element is studied, including the monochromator, the K -edge filter, the detector and the source-to-detector distance. An optimized system is proposed for diffraction-limited storage rings, such as the Advanced Photon Source Upgrade project. The simulation results show that the ps-BPM system can precisely monitor the source position and angle at high speed. Precise measurements of the source size and divergence will require adequate resolution with relatively longer integration time.

47 OTHER INSTRUMENTATION↗

pyXPCSviewer : an open-source interactive tool for X-ray photon correlation spectroscopy visualization and analysis

pyXPCSviewer , a Python-based graphical user interface that is deployed at beamline 8-ID-I of the Advanced Photon Source for interactive visualization of XPCS results, is introduced. pyXPCSviewer parses rich X-ray photon correlation spectroscopy (XPCS) results into independent PyQt widgets that are both interactive and easy to maintain. pyXPCSviewer is open-source and is open to customization by the XPCS community for ingestion of diversified data structures and inclusion of novel XPCS techniques, both of which are growing demands particularly with the dawn of near-diffraction-limited synchrotron sources and their dedicated XPCS beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Longitudinal Gradient Dipole Magnet Prototype for APS at ANL

We planned an upgrade of the Advanced Photon Source at Argonne National Laboratory (ANL). The main goal of the upgrade is to improve the storage ring performance based on more advanced optics. One of the key magnet system elements is bending dipole magnets having a field strength change along the electron beam path. Moreover, a prototype of one such longitudinal gradient dipole magnet has been designed, built, and measured in a collaborative effort of ANL and Fermilab. Our paper discusses various magnetic design options, the selected magnet design, and the fabrication technology. The prototype magnet has been measured by rotational coils, a stretched wire, and a Hall probe. Measurement results are discussed and compared with simulations.

43 PARTICLE ACCELERATORS↗

Trace element abundance determinations by Synchrotron X Ray Fluorescence (SXRF) on returned comet nucleus mineral grains

Trace element analyses were performed on bulk cosmic dust particles by Proton Induced X Ray Emission (PIXE) and Synchrotron X Ray Fluorescence (SXRF). When present at or near chondritic abundances the trace elements K, Ti, Cr, Mn, Cu, Zn, Ga, Ge, Se, and Br are presently detectable by SXRF in particles of 20 micron diameter. Improvements to the SXRF analysis facility at the National Synchrotron Light Source presently underway should increase the range of detectable elements and permit the analysis of smaller samples. In addition the Advanced Photon Source will be commissioned at Argonne National Laboratory in 1995. This 7 to 8 GeV positron storage ring, specifically designed for high-energy undulator and wiggler insertion devices, will be an ideal source for an x ray microprobe with one micron spatial resolution and better than 100 ppb elemental sensitivity for most elements. Thus trace element analysis of individual micron-sized grains should be possible by the time of the comet nucleus sample return mission.

Flynn, G. J.↗

Performance Improvement of LTS Undulators for Synchrotron Light Sources

The joint expertise of ANL and FNAL has led to the production of $\text{Nb}_{3}\text{Sn}$ undulator magnets in operation in the ANL Advanced Photon Source (APS). These magnets showed performance reproducibility close to the short sample limit, and a design field increase of 20% at 820 A. However, the long training did not allow obtaining the expected 50% increase of the on-axis magnetic field with respect to the ∼1 T produced at 450 A current in the ANL NbTi undulator. To address this, 10-pole long undulator prototypes were fabricated, and CTD-101K was replaced as impregnation material with TELENE, an organic olefin-based thermosetting dicyclopentadiene resin produced by RIMTEC Corporation, Japan. Training and magnet retraining after a thermal cycle were nearly eliminated, with only a couple of quenches needed before reaching short sample limit at over 1,100 A. TELENE will enable operation of $\text{Nb}_{3}\text{Sn}$ undulators much closer to their short sample limit, expanding the energy range and brightness intensity of light sources. TELENE is Co-60 gamma radiation resistant up to 7–8 MGy, and therefore already applicable to impregnate planar, helical and universal devices operating in lower radiation environments than high energy colliders.

43 PARTICLE ACCELERATORS↗

Toward Rapid Unattended X-ray Tomography of Large Planar Samples at 50-nm Resolution

X-ray tomography at sub-50 nm resolution of small areas ({approx}15 {mu}mx15 {mu}m) are routinely performed with both laboratory and synchrotron sources. Optics and detectors for laboratory systems have been optimized to approach the theoretical efficiency limit. Limited by the availability of relatively low-brightness laboratory X-ray sources, exposure times for 3-D data sets at 50 nm resolution are still many hours up to a full day. However, for bright synchrotron sources, the use of these optimized imaging systems results in extremely short exposure times, approaching live-camera speeds at the Advanced Photon Source at Argonne National Laboratory near Chicago in the US These speeds make it possible to acquire a full tomographic dataset at 50 nm resolution in less than a minute of true X-ray exposure time. However, limits in the control and positioning system lead to large overhead that results in typical exposure times of {approx}15 min currently.We present our work on the reduction and elimination of system overhead and toward complete automation of the data acquisition process. The enhancements underway are primarily to boost the scanning rate, sample positioning speed, and illumination homogeneity to performance levels necessary for unattended tomography of large areas (many mm{sup 2} in size). We present first results on this ongoing project.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Producing X-rays at the APS

An introduction and overview of the Advanced Photon Source at Argonne National Laboratory, the technology that produces the brightest X-ray beams in the Western Hemisphere, and the research carried out by scientists using those X-rays.

43 PARTICLE ACCELERATORS↗

Vertically polarizing undulator with the dynamic compensation of magnetic forces for the next generation of light sources

A short prototype (847-mm-long) of an Insertion Device (ID) with the dynamic compensation of ID magnetic forces has been designed, built, and tested at the Advanced Photon Source (APS) of the Argonne National Laboratory. The ID magnetic forces were compensated by the set of conical springs placed along the ID strongback. Well-controlled exponential characteristics of conical springs permitted a very close fit to the ID magnetic forces. Several effects related to the imperfections of actual springs, their mounting and tuning, and how these factors affect the prototype performance has been studied. Finally, series of tests to determine the accuracy and reproducibility of the ID magnetic gap settings have been carried out. Based on the magnetic measurements of the ID B{sub eff}, it has been demonstrated that the magnetic gaps within an operating range were controlled accurately and reproducibly within ±1 μm. Successful tests of this ID prototype led to the design of a 3-m long device based on the same concept. The 3-m long prototype is currently under construction. It represents R and D efforts by the APS toward APS Upgrade Project goals as well as the future generation of IDs for the Linac Coherent Light Source (LCLS)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Author Contribution to the Pu Handbook II: Chapter 37 LLNL Integrated Sample Preparation Glovebox (TEM) Section

The development of our Integrated Actinide Sample Preparation Laboratory (IASPL) commenced in 1998 driven by the need to perform transmission electron microscopy studies on naturally aged plutonium and its alloys looking for the microstructural effects of the radiological decay process (1). Remodeling and construction of a laboratory within the Chemistry and Materials Science Directorate facilities at LLNL was required to turn a standard radiological laboratory into a Radiological Materials Area (RMA) and Radiological Buffer Area (RBA) containing type I, II and III workplaces. Two inert atmosphere dry-train glove boxes with antechambers and entry/exit fumehoods (Figure 1), having a baseline atmosphere of 1 ppm oxygen and 1 ppm water vapor, a utility fumehood and a portable, and a third double-walled enclosure have been installed and commissioned. These capabilities, along with highly trained technical staff, facilitate the safe operation of sample preparation processes and instrumentation, and sample handling while minimizing oxidation or corrosion of the plutonium. In addition, we are currently developing the capability to safely transfer small metallographically prepared samples to a mini-SEM for microstructural imaging and chemical analysis. The gloveboxes continue to be the most crucial element of the laboratory allowing nearly oxide-free sample preparation for a wide variety of LLNL-based characterization experiments, which includes transmission electron microscopy, electron energy loss spectroscopy, optical microscopy, electrical resistivity, ion implantation, X-ray diffraction and absorption, magnetometry, metrological surface measurements, high-pressure diamond anvil cell equation-of-state, phonon dispersion measurements, X-ray absorption and emission spectroscopy, and differential scanning calorimetry. The sample preparation and materials processing capabilities in the IASPL have also facilitated experimentation at world-class facilities such as the Advanced Photon Source at Argonne National Laboratory, the European Synchrotron Radiation Facility in Grenoble, France, the Stanford Synchrotron Radiation Facility, the National Synchrotron Light Source at Brookhaven National Laboratory, the Advanced Light Source at Lawrence Berkeley National Laboratory, and the Triumph Accelerator in Canada.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Lead Shielded Enclosures for CHESS-U

Shielded enclosures are critical components of radiation safety at scientific, medical, and industrial facilities around the world. As part of the Cornell High Energy Synchrotron Source Upgrade (CHESS-U), ADC has designed, fabricated, and installed highly modular shielded enclosures ("hutches" at synchrotron facilities). ADC utilized expert consultation offered by several facilities including engineers from Advanced Photon Source (APS)(1-3) and Cornell High Energy Synchrotron Source (CHESS); with each facility providing guidance to assure that the design satisfies the rigorous radiation safety requirements. In this paper, ADC will discuss the design of these hutches, particularly the modular design elements which facilitate rapid installation to minimize downtime at the synchrotron.

enclosure↗

Data-driven picosecond X-ray imaging for quantitative plasma-induced shock characterization

Imaging dynamic events, especially shockwave behavior, is key to advancing high-energy-density (HED) research. Recent advances in fourth- and fifth-generation X-ray light sources allow for high-resolution imaging of fast phenomena, but limited beam time necessitates maximizing data acquisition. We present a benchtop-scale pulsed plasma device submerged in liquid heptane, capable of generating dynamic events at rates exceeding 10 Hz, supporting the field’s data-driven goals by producing large, high-quality imaging datasets. Using X-ray phase contrast imaging (XPCI) at the Advanced Photon Source, we imaged weak shockwaves (Mach ~ 1.2) in heptane interacting with plasma-induced cavitation bubbles, causing deviation from Rankine-Hugoniot behavior; to our knowledge, this represents the first direct imaging of such interaction. Our quantitative analysis offers insight into weak shock phenomena and energy-focusing applications in pulsed plasmas. These results highlight the potential for large datasets to advance dynamic HED research at current light source facilities, and have implications for fields such as inertial confinement fusion, plasma-enhanced chemical processing, and biomedical applications.

36 MATERIALS SCIENCE↗

APS SCIENCE 2016

The Advanced Photon Source (APS) occupies an 80-acre site on the Argonne national laboratory campus, about 25 miles from downtown chicago, illinois. it shares the site with the center for nanoscale materials and the Advanced Protein characterization facility. for directions to Argonne, see http://www.anl.gov/directions-and-visitor-information. The APS, a national synchrotron radiation research facility operated by Argonne for the u.S. department of energy (doe) office of Science, provides this nation’s brightest high-energy x-ray beams for science. research by APS users extends from the center of the earth to outer space, from new information on combustion engines and microcircuits to new drugs and nanotechnologies whose scale is measured in billionths of a meter. The APS helps researchers illuminate answers to the challenges of our high-tech world, from developing new forms of energy, to sustaining our nation’s technological and economic competitiveness, to pushing back against the ravages of disease. research at the APS promises to have far-reaching

99 GENERAL AND MISCELLANEOUS↗

Test Results of a High-Gradient 2.856-GHz Negative Harmonic Accelerating Waveguide

We report the high-gradient tests results of a novel traveling wave accelerating structure for β=0.3 based on a novel approach of operating at the first negative spatial harmonic. Accelerating gradients of 50 MV/m and peak electric fields of 160 MV/m were achieved in a single structure consisting of 15 coupled cells during tests at the advanced photon source. This work was performed by RadiaBeam, in collaboration with the Argonne National Laboratory, as a part of a Research and Development Program for the development of an ultrahigh-gradient linear accelerator, the Advanced Compact Carbon Ion Linac, for hadron therapy.

42 ENGINEERING↗