Search NASA⌕ Search

SEARCH · Search NASA

Results for “DISPATCHES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Flight Awareness Collaboration Tool

FACT is a software program that provides important information about winter weather operations to airline dispatchers and airport personnel. FACT has a "quad" design and shows various maps, text, and tabular information. It also has a team messaging capability. It is meant to be used by airline dispatchers and airport personnel to manage winter storms. This slide set provides a description of FACT that will be released to airline and airport partners who are helping to evaluate FACT. It was most recently presented at a Southwest Airlines meeting at NASA Ames on April 3, 2018.

airline operations center↗

Flight Awareness Collaboration Tool

FACT is a software program that provides important information about winter weather operations to airline dispatchers and airport personnel. FACT has a "quad" design and shows various maps, text, and tabular information. It also has a team messaging capability. It is meant to be used by airline dispatchers and airport personnel to manage winter storms. This slide set provides a description of FACT that will be released to airline and airport partners who are helping to evaluate FACT. It was most recently presented at a Southwest Airlines meeting at NASA Ames on April 3, 2018.

dispatcher↗

Flight Awareness Collaboration Tool

FACT is a software program that provides important information about winter weather operations to airline dispatchers and airport personnel. FACT has a "quad" design and shows various maps, text, and tabular information. It also has a team messaging capability. It is meant to be used by airline dispatchers and airport personnel to manage winter storms. This presentation is for a meeting with Boeing. COMMERCIAL AIRCRAFT; AIRLINE OPERATIONS; STORMS COMPUTER PROGRAMS; AIRLINE OPERATIONS; WEATHER FORECASTING; MESSAGE PROCESSING; AIRCRAFT COMMUNICATION; WINTER; STORMS (METEOROLOGY); COMMERCIAL AIRCRAFT

airline dispatchers↗

Flight Awareness Collaboration Tool

FACT is a software program that provides important information about winter weather operations to airline dispatchers and airport personnel. FACT has a "quad" design and shows various maps, text, and tabular information. It also has a team messaging capability. It is meant to be used by airline dispatchers and airport personnel to manage winter storms.

weather↗

Batteries in SAM 2020.2.29: Behind-the-Meter Systems

Provide an overview of behind the meter dispatch methods in the SAM 2020.2.29 software for analysis of residential, commercial, and generic battery systems. Discuss the details of SAM's automatic peak shaving and manual energy arbitrage dispatch options.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters: Preprint

Smart inverters (SI) have huge potential in providing grid services which has not been fully realized yet. One of these grid services, distribution network voltage regulation by SI, can improve the network voltage by regulating the SI reactive and active power output. Voltage regulation by SI is much faster compared to traditional voltage regulating devices, e.g. tap changing transformer, capacitor banks. However, there is gap in available published literature on the characteristics of SIs when the SI is controlled by local controller or external control signal. This paper presents the experimental study to characterize SI reactive power regulation response to two different control methods: autonomous control method and remote dispatch method. It was found that IS reactive power regulation response could be significantly different in terms of delay, and ramp rate for these two methods. Finally, Power-Hardware-in-The-Loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL tests results show that SI response characteristics for autonomous control method and remote dispatch method need to be considered during planning for distribution network voltage regulation using SI.

autonomous control↗

Preconceptual Designs of Coupled Power Delivery between a 4-Loop PWR and 100-500 MWe HTSE Plants

This study develops a preconceptual design for the integration between a large-scale high-temperature electrolysis facility and a NPP. Two hydrogen facility sizes are considered: 100 MWnom and 500 MWnom. Both steam supply designs use cold reheat steam extraction as a heat source. A reboiler inside the protected area of the power plant transfers steam heat to the demineralized water supply for the hydrogen plant. After the heat transfer, the extracted steam condenses and returns to the condenser while the process steam routes out of the protected area to the electrolyzers. Electrical power is tapped off from the high voltage side of the GSU transformer, where it is then transported via a 345-kV transmission line to the hydrogen facility. Circuit breakers and disconnects are located at both ends of the transmission line. Step down transformers and miscellaneous switchgear/buses are located at the end of the transmission line inside the HTEF boundary. Control capabilities for the steam interfacing equipment and electrical dispatch are accessible from the Main Control Room, and protective relays for the transmission line are located inside the Relay Room. Computer modeling was performed for the thermal and electrical designs. PEPSE analysis provided the steady-state parameters for thermal extraction from the turbine cycle. These parameters were used to inform transients and size equipment in combination with Applied Flow Technology (AFT) Arrow and AFT Fathom modeling for steam and water piping, respectively. Electrical transients were analyzed using PSCAD. An ETAP model was used to evaluate power flow and short circuit, which enabled the sizing of transformers and protective equipment. A cost estimate was developed for both integration designs when considering plant separation distances of 250 m and 500 m. From these estimates, the modifications for thermal and electrical interfacing of a first-of-a-kind nuclear-integrated hydrogen facility are anticipated to cost between $60–250/kWnom., where the subscript “nom” refers to the nominal size of the hydrogen plant. On a thermal power basis, the thermal power has a cost of approximately $8/MWth for a 500 MWnom high temperature electrolysis plant located 500 m distant from the NPP. That value decreases to approximately $7.5/MWth for a 250 m separation distance between the hydrogen plant and the NPP. This value is lower than previous estimates of the cost of heat extracted from NPPs primarily because in this work the steam is extracted from cold reheat instead of the main steam line, which reduces the cost of the dispatched steam by approximately $3.5/MWth. Nuclear steam extraction can provide a profit avenue for many plants and is not restricted to hydrogen production. Ammonia production, oil refining, and paper production, among other industrial processes all require thermal energy, which can be provided by NPPs. Future work should look further at the details of thermal extraction for a variety of use cases. This can include increased levels of extraction and multiple simultaneous users. Additionally, site-specific studies should be performed to develop industry experience and improve cost accuracy.

08 HYDROGEN↗

Cybersecurity Awareness in the Power Grid

We report on a series of interviews and observations conducted with control room dispatchers in a bulk electrical system. These dispatchers must react quickly to incidents as they happen in order to ensure the reliability and safe operation of the power grid. They do not have the time to evaluate incidents for signs of cyber-attack as part of their initial response. Cyber-attack detection involves multiple personnel from a variety of roles at both local and regional levels. Smart grid technology will improve detection and defense capabilities of the future grid, however, the current infrastructure remains a mixture of old and new equipment which will continue to operate for some time. Thus, research still needs to focus on strategies for the detection of malicious activity on current infrastructure as well as protection and remediation.

Scholtz, Jean↗

Electricity Markets and Long-Duration Energy Storage: A Survey of Grid Services and Revenue Streams

Purpose of Review Long Duration Energy Storage (LDES) is increasingly viewed as a potential resource for providing grid services that enhance the stability and flexibility of electricity systems. While some LDES services are integrated into existing market frameworks, traditional mechanisms may not fully account for their operational characteristics, potentially leading to undervaluation. Within this context, this paper reviews the literature and industry practices to assess potential grid services for LDES, evaluates existing compensation mechanisms, and identifies challenges to full market integration. Recent Findings We first review existing literature and identify key grid services unique to LDES, including enhancing grid resilience during extreme weather events, enabling long-term energy shifting, and providing flexible and firm energy in systems with limited dispatchable resources. Here, we also review how LDES services are compensated in current market frameworks and the challenges associated with the full realization of LDES values. Additionally, we summarize market mechanisms for storage technologies across U.S. wholesale markets. We find that some markets are adjusting incentive structures, such as incorporating storage duration in capacity accreditation, to better align with system needs and LDES contributions to the grid. However, further refinements in capacity remuneration and dispatch timeframes may be needed for more effective realization of LDES value. Summary This review evaluates potential grid services for LDES, examines existing compensation mechanisms for LDES technologies, and identifies gaps between these mechanisms and LDES operational characteristics. The review concludes by outlining potential market enhancements for more effective LDES integration and articulating additional research needs to support its efficient participation in future power systems.

Flexible resources↗

Evaluating grid stress and reliability in future electricity grids across a range of demand, generation mix, and weather trends

The reliability of power grids in the future will depend on how system planners account for the integration of new technologies, extreme weather events, and uncertainties in demand growth from increased electrification and data centers. This study introduces an open-source, multisectoral, multiscale modeling framework that projects grid stress and reliability trends between 2020 and 2055 in the Western Interconnection of the United States. The framework integrates global to national energy-water-land dynamics with power plant siting and hourly grid operations modeling. We analyze future wholesale electricity price shocks and unserved energy events across eight scenarios spanning a range of population growth and economic change, generation mixes, and weather conditions. Our results show future grids with high percentage of non-renewable generation and strong economic growth are characterized by higher reliability and lower wholesale electricity prices than lower growth scenarios because of larger reliance on dispatchable generators and lower fossil fuel extraction costs. Scenarios with high percentage of renewable resources have lower median but more volatile wholesale electricity prices as well as more frequent and severe unserved energy events compared to scenarios relying more on dispatchable generators. These events occur because higher proportion of solar and wind energy causes net demand curves to deepen during midday (duck curves get progressively severe), exacerbating the challenge of meeting demand during summer evening peaks. This study suggests that robust and co-optimized transmission and energy storage planning could help maintain low wholesale electricity prices and high reliability levels in future electricity grids across uncertainties in generation mixes.

Electric grid reliability↗

Microgrid to enable optimal distributed energy retail and end-user demand response

In the face of unprecedented challenges in environmental sustainability and grid resilience, there is an increasingly held consensus regarding the adoption of distributed and renewable energy resources such as microgrids (MGs), and the utilization of flexible electric loads by demand response (DR) to potentially drive a necessary paradigm shift in energy production and consumption patterns. However, the potential value of distributed generation and demand flexibility has not yet been fully realized in the operation of MGs. This study investigates the pricing and operation strategy with DR for a MG retailer in an integrated energy system (IES). Based on co-optimizing retail rates and MG dispatch formulated as a mixed integer quadratic programming (MIQP) problem, our model devises a dynamic pricing scheme that reflects the cost of generation and promotes DR, in tandem with an optimal dispatch plan that exploits spark spread and facilitates the integration of renewables, resulting in improved retailer profits and system stability. Main issues like integrated energy coupling and customer bill reduction are addressed during pricing to ensure rates competitiveness and customer protection. By evaluating on real datasets, the system is demonstrated to optimally coordinate storage, renewables, and combined heat and power (CHP), reduce carbon dioxide emission while maintaining profits, and effectively alleviate the PV curtailment problem. Finally, the model can be used by retailers and MG operators to optimize their operations, as well as regulators to design new utility rates in support of the ongoing transformation of energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An ERCOT test system for market design studies

An open source test system is developed that permits the dynamic modeling of centrally-managed wholesale power markets operating over highvoltage transmission grids. In default mode, the test system models basic operations in the Electric Reliability Council of Texas (ERCOT): namely, centrally-managed day-ahead and real-time markets operating over successive days, with congestion handled by locational marginal pricing. These basic operational features characterize all seven U.S. energy regions organized as centrally-managed wholesale power markets. Modeled participants include dispatchable generators, load-serving entities, and non-dispatchable generation such as unrmed wind and solar power. Users can congure a broad variety of parameters to study basic market and grid features under alternative system conditions. Users can also easily extend the test system's Java/Python software classes to study modied or newly envisioned market and grid features. Finally, the test system is integrated with a high-level simulation framework that permits it to function as a software component within larger systems, such as multi-country systems or integrated transmission and distribution systems. Finally, detailed test cases with 8-bus and 200-bus transmission grids are reported to illustrate these test system capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Co-optimization of repairs and dynamic network reconfiguration for improved distribution system resilience

In this work, a post-disaster distribution system repair and restoration (DSRR) strategy is proposed to improve distribution system resilience. The DSRR strategy is formulated as a two-stage optimization. The first stage is a comprehensive co-optimization of repair crew scheduling, dynamic network reconfiguration, and distributed energy resource (DER) dispatch based on the forecast load profile. The goal is to minimize the accumulative operating cost caused by the load reduction payment as well as DER operating cost. In particular, since the number of available repair crews is usually smaller than the number of faulted lines after a disaster event, the DSRR strategy determines the optimal scheduling for repairing faulted lines. The second stage is a re-dispatch of the DER power output and load shedding based on the real-time load demand of each bus. The proposed algorithm is validated by case studies of the IEEE 33-bus and 123-bus test systems. We consider those scenarios in which faults occur in multiple heavy-loaded feeders. The simulation results demonstrate that the DSRR strategy effectively coordinate the repair scheduling, network reconfiguration and load shedding to minimize the operating cost.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Beyond Price Taker: Conceptual Design and Optimization of Integrated Energy Systems Using Machine Learning Market Surrogates

Future electricity generation systems must be optimized to provide flexibility that counteracts the variability of non-dispatchable renewable energy sources and ensures the reliability and safety of critical infrastructure, including the electric grid. The current state-of-the-art is to co-optimize the design and operation of integrated energy systems (IES) treating historical or predicted time-series electricity prices as fixed parameters. Recent literature has shown the limitations of this price taker assumption, which neglects how IES optimization decisions influence market outcomes. As such, this paper proposes a new optimization formulation that uses machine learning surrogate models, trained from a library of annual market operation simulations, to embed IES market interactions into the co-optimization problem directly. Using a thermal generator example built in the open-source IDAES computational environment, we show that the price taker approach routinely over-predicts annual revenues by 8% or more compared to a validation simulation, where the proposed approach has a typical relative error of 1% or less.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of a thermosyphon-based thermal valve for controlled high-temperature heat extraction

Conventional concentrated solar power (CSP) is a reliable alternative energy source that uses the sun’s heat to drive a heat engine to produce electrical power. An advantage of CSP is its ability to store thermal energy for use during off-sun hours which is typically done by storing sensible heat in molten salts. Alternatively, thermal energy may be stored as latent heat in a phase-change material (PCM), which stores large quantities of thermal energy in an isothermal process. On-sun, the PCM melts, storing energy. Off-sun, the latent heat is extracted to produce dispatchable electrical power. Here, this paper presents the design of a thermosyphon-based device with sodium working fluid that is able to extract heat from a source as demand requires. A prototype has been designed to transfer 37 kW of thermal energy from a 600°C molten PCM tank to an array of 9% efficient thermoelectric generators (TEGs) to produce 3 kW of usable electrical energy for 5 h. This “thermal valve” design incorporates a funnel to collect condensate and a central shut-off valve to control condensate gravity return to the evaporator. Three circumferential tubes allow vapour transport up to the condenser. Pressure and a thermal resistance models were developed to predict the performance of the thermal valve. The pressure model predicts that the thermal valve will function as designed. The thermal resistance model predicts a 5500× difference in total thermal resistance between “on” and “off” states. The evaporator and condenser walls comprise 96% of the “on” thermal resistance, while the small parasitic heat transfer in the “off” state is primarily (77%) due to radiation losses. Lastly, this simple and effective technology can have a strong impact on the feasibility, scalability, and dispatchability of CSP latent storage. In addition, other industrial and commercial applications can benefit from this thermal valve concept.

14 SOLAR ENERGY↗

Capacity optimization of nuclear power integration to meet dynamic industrial demand

To decarbonize their industrial facilities, The Dow Chemical Company has collaborated with Idaho National Laboratory (INL) to study the integration of nuclear power with an industrial chemical facility. Using Holistic Energy and Resource Optimization Network developed at INL for optimizing and analyzing integrated energy systems, a nuclear microreactor system was sized and evaluated for dynamic dispatch to Dow Silicones Corporation’s Carrollton, KY (USA) site for iloxane production. It was found that a 180 MW th system (12 × 15MW th ) with 75.1 MWh th of thermal energy storage could provide heat and power to the chemical facilities. In the process, this would reduce electricity imports by 99.9 % and reduce the Scope 1 and 2 emissions of the site by 292,100 tonnes CO 2 /yr (98.8 %). The primary novelty of this work is a first of a kind design and optimization of a microreactor powered integrated energy system to provide heat and power to a chemical plant using real plant data. This analysis will pave the way for future studies using dispatchable clean energy sources to reduce carbon emissions and commodity industries’ reliance on fossil fuels.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗