Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Cutting force estimation from machine learning and physics-inspired data-driven models utilizing accelerometer measurements

Monitoring cutting forces for process control may be challenging because force measurements typically require invasive instrumentation. To remedy this situation, two new methods were recently developed to estimate cutting forces in real time based on the use of on-machine accelerometer measurements. One method uses machine learning, while another uses a physics-inspired data-driven approach, to generate a model that estimates cutting forces from on-machine accelerations. The estimated forces from both approaches were compared against cutting force data collected during various milling operations on several machine tools. The results reveal the advantages and disadvantages of each model to estimate real-time cutting forces.

Vogl, Greg↗

Missile Captive Carry Monitoring using a Capacitive MEMS Accelerometer

Military missiles are exposed to many sources of mechanical vibration that can affect system reliability, safety, and mission effectiveness. One of the most significant exposures to vibration occurs when the missile is being carried by an aviation platform, which is a condition known as captive carry. If the duration of captive carry exposure could be recorded during the missile’s service life, several advantages could be realized. Missiles that have been exposed to durations outside the design envelop could be flagged or screened for maintenance or inspection; lightly exposed missiles could be selected for critical mission applications; and missile allocation to missions could be based on prior use to avoid overuse. The U. S. Army Aviation and Missile Research Development and Engineering Center (AMRDEC) has been developing health monitoring systems to assess and improve reliability of missiles during storage and field exposures. Under the direction of AMRDEC staff, engineers at the Pacific Northwest National Laboratory have developed a Captive Carry Health Monitor (CCHM) for the HELLFIRE II missile. The CCHM is an embedded usage monitoring device installed on the outer skin of the HELLFIRE II missile to record the cumulative hours the host missile has been in captive carry mode and thereby assess the overall health of the missile. This paper provides an overview of the CCHM electrical and package design, describes field testing and data analysis techniques used to identify captive carry, and discusses the potential application of missile health and usage data for real-time reliability analysis and fleet management.

47 OTHER INSTRUMENTATION↗

Quantum accelerometer: Distinguishing inertial Bob from his accelerated twin Rob by a local measurement

A single quantum system, such as the Unruh-DeWitt detector, can be used to determine absolute acceleration by local measurements on a quantum field. To show this, we consider two kinematically indistinguishable scenarios: an inertial observer, Bob, measuring the field of a uniformly accelerated cavity, and his noninertial twin, Rob, accelerating and making measurements in a stationary cavity. We find that these scenarios can be distinguished in the nonrelativistic regime only by measurements on highly excited massive fields, allowing one to detect the noninertialness of the reference frame.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Feeling the Pull: A Study of Natural Galactic Accelerometers. II. Kinematics and Mass of the Delicate Stellar Stream of the Palomar 5 Globular Cluster

We present two spectroscopic surveys of the tidal stellar stream of the Palomar 5 globular cluster undertaken with the VLT/FLAMES and AAT/AAOmega instruments. We use these data in conjunction with photometric data presented in the previous contribution in this series to classify the survey stars in terms of their probability of belonging to the Palomar 5 stellar stream. We find that high-probability candidates are only found in a very narrow spatial interval surrounding the locus of the stream on the sky. PanSTARRS RR Lyrae stars in this region of the sky are also distributed in a similar manner. The absence of significant “fanning” of this stellar stream confirms that Palomar 5 does not follow a chaotic orbit. Previous studies have found that Palomar 5 is largely devoid of low-mass stars, and we show that this is true also of the stellar populations along the trailing arm out to 6{sup ∘}. Within this region, which contains 73% of the detected stars, the population is statistically identical to the core, implying that the ejection of the low-mass stars occurred before the formation of the stream. We also present an updated structural model fit to the bound remnant, which yields a total mass of 4297±98M{sub ⊙} and a tidal radius 0.145±0.009 kpc. We estimate the mass of the observed system including the stream to be 12,200 ± 400 M {sub ⊙}, and the initial mass to have been ∼47,000 ± 1500 M {sub ⊙}. These observational constraints will be employed in our next study to model the dynamics of the system in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Missile Captive Carry Monitoring and Helicopter Identification Using a Capacitive Microelectromechanical Systems Accelerometer

Military missiles are exposed to many sources of mechanical vibration that can affect system reliability, safety, and mission effectiveness. The U. S. Army Aviation and Missile Research Development and Engineering Center (AMRDEC) has been developing missile health monitoring systems to assess and improve reliability, reduce life cycle costs, and increase system readiness. One of the most significant exposures to vibration occurs when the missile is being carried by a helicopter or other aviation platform, which is a condition known as captive carry. Recording the duration of captive carry exposure during the missile’s service life can enable the implementation of predictive maintenance and resource management programs. Since the vibration imparted by each class of helicopter varies in frequency and amplitude, tracking the vibration exposure from each helicopter separately can help quantify the severity and harmonic content of the exposure. Under the direction of AMRDEC staff, engineers at the Pacific Northwest National Laboratory have developed a Captive Carry Health Monitor (CCHM) for the Hellfire II missile. The CCHM is an embedded usage monitoring device installed on the outer skin of the Hellfire II missile to record the cumulative hours the host missile has been in captive carry mode. To classify the vibration by class of helicopter, the CCHM analyzes the amplitude and frequency content of the vibration with the Goertzel algorithm to detect the presence of distinctive rotor harmonics. Cumulative usage data are accessible in theater from an external display; monthly usage histograms are accessible through an internal download connector. This paper provides an overview of the CCHM electrical and package design, describes field testing and data analysis techniques used to monitor captive carry identify and the class of helicopter, and discusses the potential application of missile health and usage data for real-time reliability analysis and fleet management.

Goertzel, HUMS↗

Fabry-Perot MEMS Accelerometers for Advanced Seismic Imaging

This report summarizes the technical achievements that occurred over the duration of the project. On November 14th, 2014, Lumedyne Technologies Incorporated was acquired. As a result of the acquisition, the work toward seismic imaging applications was suspended indefinitely. This report captures the progress achieved up to that time.

02 PETROLEUM↗

TRUST Sensors in Environments: Accelerometers (SE-A) Report, Release FY24

The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computational and experimental capabilities that are applicable to the development, on-target assessment, and qualification of current and future delivery environments. The TRUST project consists of five "low-complexity", single-feature testbeds used to conduct experiments with accompanying models and simulations. Each of the five single feature testbeds aims to isolate an engineering feature or behavior of interest, then work towards improving the fundamental engineering understanding of that feature. Additionally, the single feature testbeds are used to identify capability development needs that can help reduce model and experimental uncertainty.

97 MATHEMATICS AND COMPUTING↗

TRUST Sensors in Environments: Accelerometers (SE-A) Report Release FY25

The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computa tional and experimental capabilities that are applicable to the development, on-target assessment, and qualification of current and future delivery environments. The TRUST project consists of five "low-complexity", single-feature testbeds used to conduct experiments with accompanying models and simulations. Each of the five single feature testbeds aims to isolate an engineering feature or behavior of interest, then work towards improving the fundamental engineering understanding of that feature. Additionally, the single feature testbeds are used to identify capability development needs that can help reduce model and experimental uncertainty.

42 ENGINEERING↗