Search NASA⌕ Search

SEARCH · Search NASA

Results for “ICP MS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

In Situ Analysis of Orthopyroxene in Diogenites Using Laser Ablation ICP-MS

Howardites, eucrites and diogenites (HED) form a suit of igneous achondrite meteorites that are thought to have formed on a single asteroidal body. While there have been many different models proposed for the formation of the HED parent asteroid they can be generalized into two end member models. One is the magma ocean model (e.g. [1]) in which the entire HED parent body was continuously fractionated from a planet wide magma ocean with diogenites representing the lower crust and eucrites being upper crustal rocks. The second model hypothesizes that diogenites and eucrites were formed as a series of intrusions and/or extrusions of partial melts of a primitive proto-Vesta [2]. We use in situ trace element analysis together with major and minor element analysis to try and distinguish between these different hypotheses for the evolution of the HED parent body.

Elk, Mattias↗

Lithium isotopic analysis in depleted lithium salts

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. Here, in this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts across both depleted and natural isotopic abundances. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for online process monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

Humic Acid Complexation of Th, Hf and Zr in Ligand Competition Experiments: Metal Loading and Ph Effects

The mobility of metals in soils and subsurface aquifers is strongly affected by sorption and complexation with dissolved organic matter, oxyhydroxides, clay minerals, and inorganic ligands. Humic substances (HS) are organic macromolecules with functional groups that have a strong affinity for binding metals, such as actinides. Thorium, often studied as an analog for tetravalent actinides, has also been shown to strongly associate with dissolved and colloidal HS in natural waters. The effects of HS on the mobilization dynamics of actinides are of particular interest in risk assessment of nuclear waste repositories. Here, we present conditional equilibrium binding constants (Kc, MHA) of thorium, hafnium, and zirconium-humic acid complexes from ligand competition experiments using capillary electrophoresis coupled with ICP-MS (CE- ICP-MS). Equilibrium dialysis ligand exchange (EDLE) experiments using size exclusion via a 1000 Damembrane were also performed to validate the CE-ICP-MS analysis. Experiments were performed at pH 3.5-7 with solutions containing one tetravalent metal (Th, Hf, or Zr), Elliot soil humic acid (EHA) or Pahokee peat humic acid (PHA), and EDTA. CE-ICP-MS and EDLE experiments yielded nearly identical binding constants for the metal- humic acid complexes, indicating that both methods are appropriate for examining metal speciation at conditions lower than neutral pH. We find that tetravalent metals form strong complexes with humic acids, with Kc, MHA several orders of magnitude above REE-humic complexes. Experiments were conducted at a range of dissolved HA concentrations to examine the effect of [HA]/[Th] molar ratio on Kc, MHA. At low metal loading conditions (i.e. elevated [HA]/[Th] ratios) the ThHA binding constant reached values that were not affected by the relative abundance of humic acid and thorium. The importance of [HA]/[Th] molar ratios on constraining the equilibrium of MHA complexation is apparent when our estimated Kc, MHA values attained at very low metal loading conditions are compared to existing literature data. Overall, experimental data suggest that the tetravalent transition metal/-actinide-humic acid complexation is important over a wide range of pH values, including mildly acidic conditions, and thus, these complexes should be included in speciation models.

humic acid↗

Mapping of lanthanide-tagged proteins on western blot paper using microextraction-inductively coupled plasma-mass spectrometry

A microextraction (ME) sampling system, paired with inductively coupled plasma-mass spectrometry (ICP-MS), was employed to spatially analyze proteins tagged with lanthanum (La), gadolinium (Gd), or terbium (Tb) on the surface of western blot paper. The proteins were covalently tagged, separated via gel electrophoresis, and transferred to western blot paper for analysis by ME-ICP-MS. The ME-ICP-MS method enables the direct sampling of the tagged species on the western blot paper, without any sample preparation. Traditionally, the tagged analyte would need to be stained, excised, and digested to be analyzed by ICP-MS for its elemental and isotopic characterization. Preliminary detection limits for the ME-ICP-MS method applied to western blot paper were established to be 564, 54, and 2.5 fg for La, Gd, and Tb, respectively. The developed ME-ICP-MS method was compared to laser ablation (LA) ICP-MS, another direct solid sampling technique; it was readily determined that ME-ICP-MS can effectively map the elemental constituents on the western blot paper with comparable analysis time and measurement sensitivity. The analysis time per 2 × 4 mm extraction is ∼1 minute; if protein spots are directly targeted (rather than systematically mapping the entire blot paper), the analysis time per protein spot is ∼1 min. This developed method proved to be fast, effective, and accessible for correlating protein molecular weight with the detection of the inorganic tagant. The ME-ICP-MS approach could be widely applicable in research areas that involve metal-tagged protein bioconjugates, such as in the development of diagnostic and therapeutic agents and other biochemical probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid isotopic analysis of uranium microparticles via SP-ICP-TOF-MS

Inductively coupled plasma – time-of-flight – mass spectrometry (ICP-TOF-MS) was employed for the isotopic analysis of uranium particles of varying 235 U enrichment levels. Here, a single particle (SP)-based introduction scheme was employed such that individual particles, in a suspension, were analyzed. The uranium oxide microparticles were comprised of depleted uranium (DU, 235 U/ 238 U of 0.0017316(14)), natural uranium (NU, 235 U/ 238 U of 0.0072614(39)), and low enriched uranium (LEU, 235 U/ 238 U of 0.051025(15)). The percent relative difference of the SP-ICP-TOF-MS measured isotopic ratios compared to the expected values for the DU, NU, and LEU particle populations were 8.75, 0.12, and 1.23 %, respectively. After characterization, the DU and NU particles were doped within a complex sample matrix (Arizona Test Dust) containing Fe, Ti, Al, and Si particles, among others. Then, the suspension was analyzed via SP-ICP-TOF-MS and the detected particles were classified as DU or NU based on their measured 235 U/ 238 U ratio. In the same analysis, the matrix particles (i.e., Al, Fe, and Ti) were detected, demonstrating the simultaneous nuclide detection provided by the measurement platform. The presented SP-ICP-TOF-MS methodology for uranium particle characterization proved to be a high throughput method for detecting and isotopically discerning uranium particles with varying enrichment levels, in a complex matrix.

Stanberry, Jordan S. [Oak Ridge National Laborator↗

The Contrast in Outgassing of Germanium Between Shergottites and Nakhlites

Final Paper and not the abstract is attached. Introduction: Germanium is generally thought to follow Si in its geochemical behavior, but little data has existed to rigorously understand the behavior of Ge in the Martian mantle. Germanium is known to be more siderophile than Si, and its partitioning into the martian core has been studied by. Typical abundances in igneous martian meteorites range from 0.5-3 ppm, a larger range than what is observed in terrestrial basalts (1.5 +/- 0.1 ppm). In situ measurements by the MER and MSL rovers have revealed a surprisingly large range in Ge abundances in surface rocks (30-650 ppm), but many igneous rocks and soils are shown to have greater than 30 ppm Ge (the detection limit of the APXS). Recently, reported that shergottite minerals showed a depletion of Ge with increasing fractionation, while nakhlites and chassignites exhibited Ge behavior compatible with closed system igneous differentiation. They interpreted their observations as tentatively indicating volcanic outgassing of Ge from shergottites (but not from nakhlite-chassignites) with recondensation of the Ge vapor into soils and breccias. Recent experimental studies show that Ge is significantly volatile from magmas. In this study, we followed up on those results by analyzing minerals in five nakhlites and five shergottites by laser ablation ICP-MS (LA-ICP-MS). See Attached

Yang, S.↗

Microextraction-Single Particle-Inductively Coupled Plasma-Mass Spectrometry for the Direct Analysis of Nanoparticles on Surfaces

A novel employment of single particle-inductively coupled plasma-mass spectrometry (SP-ICP-MS) was developed, where a microextraction (ME) probe is used to sample nanoparticles from a surface and analyze them in a single analytical step. The effects of several parameters on the performance of ME-SP-ICP-MS were investigated, including the flow rate, choice of carrier solution, particle size, and the design of the microextraction probe head itself. The optimized ME-SP-ICP-MS technique was used to compare the extraction efficiency (EE, defined as the ratio of particles measured to particles deposited on the surface) of the commercial probe head to a newly designed SP polyether ether ketone (PEEK) probe head. The SP PEEK probe head was found to have increased EE compared to the commercial probe head (8.5 ± 3% vs 3.9 ± 3%, respectively). Increasing the carrier solution flow rate was found to decrease the total analysis time at the cost of decreasing EE. Extraction efficiencies for ME-SP-ICP-MS were typically 4–10%, which is similar to transport efficiencies (1–10%) for conventional SP-ICP-MS. Lastly, ME-SP-ICP-MS was employed for the analysis of nano- and microparticles. The sizes of gold nanoparticles, 30 ± 3 and 51 ± 1.9 nm (certified sizes), and iron-based microparticles, 1000 ± 50 nm (certified size), were accurately determined to be 32.2 ± 2.5, 50.8 ± 3.4, and 1030 ± 57 nm, respectively, by ME-SP-ICP-MS. Further, this work demonstrates the potential of ME-SP-ICP-MS for the direct analysis of particles on common collection surfaces (GSR tabs, carbon planchettes, etc.) while retaining spatial information on particle distribution across the surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the feasibility of LA-ICP-TOF-MS for the analysis of environmental particle collections

Laser ablation-inductively coupled plasma-time-of-flight-mass spectrometry (LA-ICP-TOF-MS) was employed to rapidly analyze environmental particle samples collected using aerosol contaminate extractors (ACE). The ACE particle collectors were placed at various distances (0.5, 1.3, and 4.5 km) from a source that released Ru-bearing particles. Samples for measurement were then generated (as sub-samples) from the ACE collection plates via particle “lift off” with gunshot residue (GSR) tabs. The LA-ICP-TOF-MS method was employed such that 10+ samples could be analyzed in a single unattended analytical session. A 3 × 1 mm area of individual GSR tab samples were analyzed in less than 30 minutes. This provided spatially resolved elemental and isotopic measurements of the particulate content and confirmed the presence of Ru-bearing particles within the complex background environmental particle loading. As anticipated, measurements showed collectors closest to the source had the highest concentration of the released Ru-bearing particles, while all collectors, regardless of distance, contained similar levels of background particles (e.g., Fe and Sr). Sequential scanning electron microscopy – automated particle analysis (SEM-APA) and LA-ICP-TOF-MS analysis was employed for method validation and a demonstration of the multi-modal approach. The same 2-dimensional region was analyzed by both methods and the particles identified via SEM-APA were also detected using LA-ICP-TOF-MS, with 100% accuracy. Overall, LA-ICP-TOF-MS demonstrated its utility for rapid elemental and isotopic particle analysis from environmental air samples.

Manard, Benjamin T. [Oak Ridge National Laboratory↗

Cation Data for the East River Watershed, Colorado (2014-2025)

This data package contains mean values for cation concentration for water samples taken from the East River Watershed in Colorado. Inductively coupled plasma mass spectrometry (ICP-MS) has been used to measure the concentrations of elements of interest simultaneously for the East River Watershed, Colorado groundwater and surface water samples to inform insights on the biogeochemistry processes within the watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. For samples collected prior to 06-16-2021, the instrumentation, Elan DRC II, PerkinElmer SCIEX, automatically switches among the three models necessary to analyze all 37 elements. These 37 elements include: (1) Lithium (Li), Beryllium (Be), Boron (B), Sodium (Na), Magnesium (Mg), Aluminium (Al), Silicon (Si), Phosphorus (P), Titanium (Ti), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Caesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th), Uranium (U) using standard model, argon Ar as reaction gas, (2) Potassium (K), Calcium (Ca), Vanadium (V), Chromium (Cr), Manganese (Mn), Iron (Fe) using dynamic reaction cell (DRC) model, ammonia NH3 as reaction gas, and (3) Phosphorus (P) and Selenium (Se) using DRC model, oxygen O2 as reaction gas. Note for the samples with higher concentrations of chloride (Cl-), asenic (As) concentrations were analysed with DRC model (oxygen O2 as reaction gas) to avoid the interference of chloride. For samples collected on and after 06-16-2021, an advanced Agilent 8900 triple quadrupole inductively coupled plasma mass spectrometry system (Agilent 8900 QQQ ICP-MS, Agilent Technologies) has been used to measure the concentrations of interested 36 elements simultaneously for environmental samples, including (1) Lithium (Li), Beryllium (Be) and Boron (B) using standard no gas mode, (2) Sodium (Na), Magnesium (Mg), Aluminium (Al) Phosphorus (P), Potassium (K), Chromium (Cr), Manganese (Mn), Iron (Fe), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Cesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th) and Uranium (U) using standard helium (He) collision mode, (3) Titanium (Ti) and Vanadium (V) using high Energy (HEHe) helium (He) collision mode, and (4) Silicon (Si), Calcium (Ca) and Selenium (Se) using standard H2 reaction mode. All samples were prepared/diluted with 2% (v/v) ultrapure nitric acid in Milli-Q water (18.2 mega ohm-cm), and analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (cation_data_2014_2025.zip) containing a total of 5,849 files: 5.848 data files of cation data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the detemination of Method Detection Limits (MDLs) for ICP-MS PerkinElmer DRC II instrumentation (Detemination_of_Method_Detection_Limits__MDLs__for_ICP_MS__PerkinElmer_Elan_DRC_II__LBL_Bldg74_Lab214D) for samples before November 2021; (5) PDF and docx files for the determination of MDLs for ICP-MS Agilent 8900 QQQ instrumentation (ICP_MS_Analysis_detection_limits_and_QA_QC_WenmingDong_updated_2026-08-06) for samples November 2021 and onward. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing cation data. Update on 2021-04-11: Added Detemination of Method Detection Limits (MDLs) for ICP-MS document, which can be accessed as a PDF or with Microsoft Word. Update on 2022-06-10: versioned updates to this dataset was made along with these changes: (1) updated cation data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) removed suffix and prefix on two variables (“aqberylliumion_asberyllium” and “aqlithiumion_aslithium”), (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-16. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Updated versions of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-06, of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021.

54 ENVIRONMENTAL SCIENCES↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Microstructure-dependent particulate populations in ODS steels revealed by single-particle ICP-TOF-MS

In this work, we evaluated the ability of single-particle inductively coupled plasma time-of-flight mass spectrometry (SP-ICP-TOF-MS) to characterize particulates generated from 300 series stainless steels and oxide dispersion–strengthened (ODS) steels. Particulates were produced using two different rotary tools (cutting disk and grinding bit) to assess the influence of particle generation on effluent particulates. Across all materials and preparation techniques, SP-ICP-TOF-MS detected a substantial population of particles containing the expected constituent elements, with average compositions closely matching the nominal alloy values. A secondary population of Y-bearing particles was evident in ODS steels; their formation is strongly favored in particulates generated using the grinding bit. Specifically, in PM2000, Y-bearing particles were predominantly colocated with Al, whereas in 14YWT, Y-bearing particles were less frequently Fe-free but showed stronger colocation with Ti. These trends are consistent with the known microstructural differences between Y–Al–O oxide particles in PM2000 and finer Y–Ti–O nanoclusters in 14YWT. Together, these results demonstrate that SP-ICP-TOF-MS can resolve distinct particulate populations in complex, multicomponent steels at the femtogram mass scale, enabling particle-resolved insight into microstructure-driven phase separation and preparation-dependent particle generation.

Brubaker, Zach E. [Oak Ridge National Laboratory (↗

Round Robin Analysis of Uranium Isotopics on Cotton Swipes Measured Using Microextraction-Based Sampling Versus Conventional Bulk Analysis

A comparison of microextraction sampling methods to directly analyze uranium isotopics on cotton swipes was performed concurrently with traditional bulk-processing methods. For the microextraction sampling approach, two different detection platforms were evaluated, a quadrupole-based inductively coupled plasma mass spectrometer (ICP-MS) and the liquid sampling-atmospheric pressure glow discharge (LS-APGD) coupled to an Orbitrap mass spectrometer. Results presented from this innovative sampling approach (i.e., microextraction) are compared with a more traditional approach employed for analysis of cotton-based environmental swipes, namely bulk ashing/digestion, separation, and subsequent analysis by high-precision multi-collector ICP-MS. Overall, the microextraction approach proved to be a reliable and accurate means to determine isotopic ratios of uranium collected on cotton swipes. The ICP-MS-based detection had relative standard deviations of <0.65% for the major isotopic determinations, whereas the LS-APGD-Orbitrap method had relative standard deviations of <3%. The percent relative difference for the 235 U/ 238 U ratios, in comparison to the expected values, was <1% for ICP-MS and <4% for the microplasma-Orbitrap method. Additionally, the microextraction ICP-MS accurately (<2%) and precisely (<5%) determined the minor isotopic compositions (i.e., 234 U/ 238 U and 236 U/ 238 U).

ICP-MS↗

Effect of Anoxic Iron Corrosion on WIPP Brine Geochemistry FY23 Final Report (U)

A 280-day study was completed to evaluate the effect of zero-valent iron (Fe 0 ) on the Waste Isolation Pilot Plant (WIPP) brine geochemistry under anticipated reducing conditions. Hydrogen (H 2 ) gas is expected to be present in the repository after closure due to the anoxic corrosion of a vast quantity of iron contained in the waste forms disposed at WIPP; therefore, a background argon atmosphere containing H 2 was chosen for this study. WIPP groundwater brine pH and E h will impact the mobility and fate of plutonium within the repository. Modeling and laboratory results for Castile WIPP brine indicate that equilibrium fa values relative to the standard hydrogen electrode (SHE) are 40 mV more reducing (i.e., more negative) than those for Salado WIPP brine (-480 mV vs. -440 mV, respectively) because of the higher pH of the Castile brine (pH 9 .3 for Castile vs. pH 8.8 for Salado). The E h and pH data were corrected for the effects of high ionic strength. The experimental results for both brines are consistent with thermodynamic predictions using OLI Systems' Mixed Solvent Electrolyte chemical equilibrium model. The measured and corrected pH and E h data from this study are provided in Table ES-I and Table ES-2, respectively. The experimental study, with four test conditions in triplicate, was performed in a dual glovebox with a nominally 3 vol.% H 2 in argon atmosphere (target H 2 range: 3 ± I vol.%). Simulants containing MgO only ( experimental control) and MgO+Fe 0 (WIPP base case) were prepared for both the Salado and Castile brines. MgO was included in all simulants to account for the use of bulk magnesium oxide in the WIPP repository. Fe 0 was included in some simulants to incorporate the effects of the anoxic corrosion of iron and in-situ hydrogen generation in the study. The brine compositions were developed by Sandia National Laboratory (SNL; Xiong, 2008) and have been used in previous WIPP evaluations. The test method (agitation, etc.) is partially based on ASTM D3987-12. Twelve rounds of periodic measurements of pH and E h were performed over the course of the study. Chemical analysis results for liquids and solids (ICP-MS, ICP-ES, IC Anion, TIC, SEM-EDX) are consistent with the pH, E h , and thermodynamic modeling results. This study included the following conditions that deviate from anticipated post-closure conditions following brine intrusion, but were selected to facilitate bench-scale testing to validate modeling of pH and E h for the post-closure WIP P repository: an anoxic glove box atmosphere containing ≤ 4 vol. % H 2 vs. substantially higher H 2 gas concentrations assumed in the WIPP Performance Assessment (PA); a significantly higher liquid-to-solid test ratio compared to the much lower phase ratio anticipated in the WIP P repository; agitation of the simulant bottles to maximize mass transfer; and finally the use of Fe 0 reagents having a much greater surface area than expected in the WIP P repository. Non-representative conditions were chosen for various reasons such as: to provide bounding conservative results, to provide a margin of safety for testing, or to facilitate simulant sub-sampling and analysis. In a parallel effort, aqueous electrolyte thermodynamic models were developed for the synthetic Salado and Castile brines to inform the experimental design, facilitate laboratory data interpretation, and allow extension of evaluations beyond the parameters tested. Thermodynamic modeling simulations including the MgO and Fe 0 additives that are directly relevant to the experimental measurements (e.g., pH calibration curve, ORP corrections) are included in this report. The measured fa of the simulants was close to the OLI model predictions for both brines and was largely controlled by the background H 2 partial pressure in the vapor phase as well as H 2 generated in situ in the aqueous phase by the Fe 0 corrosion. The H 2 gas-phase concentration tested and thermodynamically evaluated was much lower than is assumed in the WIPP PA; however, H 2 (g) concentrations significantly below this level are still predicted to result in very reducing conditions. In conclusion: • The experimental results are consistent with thermodynamic model predictions for fa, pH, and the effects of high ionic strength. • Evidence to date suggests that the H2 concentration in the glovebox atmosphere ultimately determined the final E h values of the simulants and resulted in highly reducing conditions. As a result, little difference was observed between the control simulants containing only MgO and the WIPP base-case simulants that contained MgO and Fe 0 . • This test methodology is recommended for future studies evaluating WIPP repository conditions. The methodology includes: (1) background H 2 in argon with agitation ( or could alternatively include in-situ-generated H 2 in sealed bottles); (2) carefully measured and corrected ORP data ( with much effort focused on allowing the probes to fully stabilize); and (3) ionic-strength-corrected pH data. Other best practices, such as simulant sparging/handling, ORP probe replacement, etc., should also be considered. • The coupling of experimental studies and thermodynamic modeling is also highly recommended because these methods inform and direct one another leading to greater confidence in and understanding of the results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acquisition of a High-resolution Inductively Coupled Plasma Mass Spectrometer for Cosmochemical and Geochemical Research

The primary goal of our research in this program is to develop new techniques for the analysis of volatile trace elements in very small samples using inductively coupled plasma mass spectrometry (ICP-MS) in preparation for samples returned by the Stardust mission. The instrument that will serve as the basis of our experiments is the ELEMENT2 high-resolution ICP-MS. We have spent the past year designing the laboratory to house this instrument as well as space to store and prepare samples returned by the Stardust mission. Unfortunately, the location that we had initially selected for the instrument turned out to be insufficient for our needs. This was determined almost eight months into the first year of our funding cycle, after extensive work including the production of engineering drawings. However, during this time the Lunar and Planetary Laboratory was selected to lead Phoenix, the first Mars Scout mission. As a result of this award LPL purchased a new, 50,000 square foot building. We have acquired 1400 square feet of laboratory space in this new facility. Four-hundred square feet will be used for a class-100 clean room. This area is designated for storage and preparation of extraterrestrial materials. The additional 1000 square feet will house the ELEMENT2 ICP-MS and peripheral devices. This is an enormous amount of space for this instrument, but it provides plenty of room for expansion in the future. The ICP-MS and the clean room facilities have been purchased. The instrument has been delivered. The startup time for this instrument is relatively short and we expect to be collecting our first data by mid-summer.

Lauretta, D. S.↗

Determination of Silicon in Hydrazine

Inductively coupled plasma-mass spectrometry (ICP-MS) is a highly sensitive technique sometimes used for the trace determination of silicon at a mass-to-charge (m/z) ratio of 28, the most abundant natural isotope of silicon. Unfortunately, ICP-MS is unable to differentiate between other sources of m/z 28 and false positive results for silicon will result when other sources of m/z 28 are present. Nitrogen was a major source of m/z 28 and contributes to the m/z 28 signal when hydrazine sample or nitric acid preservative is introduced into the plasma. Accordingly, this work was performed to develop a sample preparation step coupled with an ICP-MS analysis that minimized non-silicon sources of m/z 28. In the preparatory step of this method, the hydrazine sample was first decomposed predominately to nitrogen gas and water with copper-catalyzed hydrogen peroxide. In the analysis step, ICP-MS was used without nitric acid preservative in samples or standards. Glass, a potential source of silicon contamination, was also avoided where possible. The method was sensitive, accurate, and reliable for the determination of silicon in monopropellant grade hydrazine (MPH) in AF-E-332 elastomer leaching tests. Results for silicon in MPH were comparable to those reported in the literature for other studies.

McClure, Mark B.↗

In Situ Mg/Ca Measurements on Foraminifera: Comparison Between Laser Ablation Inductively Coupled Plasma Mass Spectrometry and Wavelength-Dispersive X-Ray Spectroscopy by Electron Probe Microanalyzer

We present a comparison of two different techniques: Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) and wavelength-dispersive X-Ray Spectroscopy by electron probe microanalyzer (EPMA) for obtaining Mg/Ca ratios in individual foraminifera shells. The goal is to assess the use of EPMA as an alternative technique for Mg/Ca analyses of single foraminiferal calcite shells. Foraminifera obtained from sediments (benthic, Uvigerina spp.) and from plankton tows (planktonic, Orbulina universa) were analyzed. All specimens were prepared in epoxy mounts and exposed in cross-section such that multiple high-resolution analyses could be completed on the shells using both techniques. We examined our data using statistical methods designed for the assessment and comparison of measurement techniques. In the case of Uvigerina, the mean difference for ratios obtained using EPMA and LA-ICP-MS is very small (−0.046 mmol mol−1) and scale independent. The Limits of Agreement (LoA, the standard deviation of the bias plus the mean bias) is [−0.315, 0.223] mmol mol−1. For samples with ratios lower than 13 mmol mol−1, we found a mean EPMA–LA-ICP-MS bias of −2.44 mmol mol−1 and a corresponding LoA of [−3.85, −1.04] mmol mol−1. For ratios higher than 13 mmol mol−1, there appears to be a scale dependent bias, meaning that the EPMA measured ratios become progressively larger than those of LA-ICP-MS as the Mg/Ca ratio increases, so the mean bias and LoA metrics are not meaningful. Results indicate that it is possible to use EPMA to collect Mg/Ca data, if the ratios are lower than ∼13 mmol mol−1.

EPMA↗

On-line Inductively Coupled Plasma Mass Spectrometry Reveals Material Degradation Dynamics of Au and Cu Catalysts during Electrochemical CO 2 Reduction

A significant challenge in commercializing electrochemical CO 2 reduction (CO 2 R) is achieving catalyst durability. Here, in this study, online inductively coupled mass spectrometry (ICP–MS) was used to investigate catalyst degradation via nanoparticle detachment and/or dissolution into metal ions under CO 2 R operating conditions in 0.1 M KHCO 3 . We developed an experimental framework with ex situ characterization to validate the online ICP–MS method for in situ evaluation of degradation from metal foils. By varying the applied potential and microenvironment (CO 2 vs N 2 -saturated electrolyte), we gained insights into the degradation of Au and Cu foils under CO 2 R and hydrogen evolution reaction (HER) conditions. While both Au and Cu foils were observed to be stable to dissolution in these regimes, degradation via nanoparticle detachment from the foil surface at the femtogram scale was observed as a function of reaction conditions, providing new insights into material degradation mechanisms. When applying potential steps at −0.1 and −1.0 V vs the reversible hydrogen electrode (RHE), Au was found to degrade via nanoparticle detachment under CO 2 R operating conditions more than under HER conditions, while Cu was found to degrade via nanoparticle detachment in similar amounts during both reactions. Au lost ∼1.8× more mass and ∼7.5× more nanoparticles than Cu under CO 2 R operating conditions. This study demonstrates the use of online ICP–MS to gain insight into the degradation of Au and Cu, the importance of studying unconventional degradation mechanisms such as nanoparticle detachment, and that online ICP–MS can be further utilized to gain fundamental understanding of catalyst durability for a variety of reaction systems.

Yan, Katherine [Stanford Univ., CA (United States)↗