Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Testing of Liquid Scintillator Materials for Gamma and Neutron Detection

The key fact about fissile material is that a sufficient quantity of the material can produce chains of fissions, including some very long chains. A chain of fissions will give rise to a detected burst of neutrons with longer chains generally producing larger bursts. These bursts produce distinctive time correlations in a detector near the multiplying material. These correlations are measurable and can be analyzed to infer attributes of the fissile material including fissile material mass, assembly neutron multiplication, characteristic fast fission chain evolution time scale, also known as the {alpha} time scale, thermalization time scale. The correlation signal is very robust with respect to background and to neutron absorbing material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of MSNDs for Fast-Neutron Detection and the TREAT Hodoscope

The need for next-generation, accident-tolerant fuels has generated significant interest in the restart of domestic fuels testing at the Transient Reactor Test (TREAT) facility. A key feature of the TREAT reactor core is an open, horizontal channel that allows line-of-sight viewing of test specimens using various instrumentation during steady-state and transient operation. This instrumentation includes the hodoscope, which consists of over 300 steel-collimated channels coupled to Hornyak buttons (and other detectors) for detection of fast neutrons emitted from fission of the test specimen. Posterior analysis can be used to reconstruct fuel motion and other properties from the collimated channel signals. A large-scale effort is underway to develop next generation instrumentation for transient testing at TREAT (and, potentially, other facilities). Work at KSU specifically aims to provide improved detection systems for hodoscope applications. It was initially proposed to adapt KSU-developed Microstructured Semiconductor Neutron Detectors (MSNDs) for use as fast-neutron detectors. The current generation of MSNDs is designed for thermal-neutron detection based on {sup 6}Li and can achieve intrinsic efficiencies nearing 30% owing to the large (n, t) cross section of {sup 6}Li and clever optimization of the geometry. In order to evaluate MSNDs for fast-neutron detection, two approaches were considered: (1) use of a hydrogenous material to thermalize neutrons to exploit the intrinsic efficiencies of current MSNDs, and (2) substitution of a fast-sensitive reactant for {sup 6}Li. The former approach is attractive because it makes use of proven, off-the-shelf technology and leads to reasonable time resolution and efficiency. Unfortunately, use of thermalization leads to prohibitive degradation of spatial resolution. The second approach will require further experimental efforts, but scoping analyses suggest {sup 235}U- or {sup 237}Th-loaded MSNDs may achieve sufficient efficiencies. The rest of this summary examines these issues in more detail. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Status Summary of 3He and Neutron Detection Alternatives for Homeland Security

This is a short summary whitepaper on results of our alternatives work: Neutron detection is an important aspect of interdiction of radiological threats for homeland security purposes since plutonium, a material used for nuclear weapons, is a significant source of fission neutrons [Kouzes 2005]. Because of the imminent shortage of 3He, which is used in the most commonly deployed neutron detectors, a replacement technology for neutron detection is required for most detection systems in the very near future [Kouzes 2009a]. For homeland security applications, neutron false alarms from a detector can result in significant impact. This puts a strong requirement on any neutron detection technology not to generate false neutron counts in the presence of a large gamma ray-only source [Kouzes et al. 2008].

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Neutron-detecting apparatuses and methods of fabrication

Neutron-detecting structures and methods of fabrication are provided which include: a substrate with a plurality of cavities extending into the substrate from a surface; a p-n junction within the substrate and extending, at least in part, in spaced opposing relation to inner cavity walls of the substrate defining the plurality of cavities; and a neutron-responsive material disposed within the plurality of cavities. The neutron-responsive material is responsive to neutrons absorbed for releasing ionization radiation products, and the p-n junction within the substrate spaced in opposing relation to and extending, at least in part, along the inner cavity walls of the substrate reduces leakage current of the neutron-detecting structure.

36 MATERIALS SCIENCE↗

Comparisons in Neutron Detection, as modeled by MCNPX, in Li-6 Glass, HE-3, BF-3, and Borated PVT

With the potential shortage of He-3 being reported by venders, it is important to consider other materials for neutron detection. Traditional neutron detectors are composed of BF-3 and He-3. Recently Li-6 Glass and borated PVT have been presented as possible replacements. This work will compare the relative detection efficiencies and consider other factors to determine the most appropriate neutron detection material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Detection in the A2 Collaboration Experiment on Neutral Pion Photo-production on Neutron

Neutron detection is of crucial importance for the neutral pion photo-production study on a neutron target that now is in progress at MAMI. Two electro-magnetic calorimeters, based on NaI and BaF 2 crystals, are used in the A2 experiment. While these calorimeters are optimized for pion decay photon detection, they have a reason able efficiency for neutron detection also. The paper describes the method, which has been used to measure this efficiency using the same data taken for pion photo-production study on deuterium target with tagged photon been of 800 MeV maximal energy. As a result, the detection efficiency is a rising function of neutron momentum that reaches 40% near 1 GeV/c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

YAP:Ce scintillator characteristics for neutron detection

YAP:Ce (YAlO{sub 3}:Ce{sup +}, Yttrium Aluminum Perovskite, Ce{sup +} doped) crystals with appropriate converters seem like prospective scintillators for neutron detection. An important aspect for neutron detection with inorganic scintillators is the ability to discriminate neutron radiation from gamma radiation by pulse height of signals. For a detailed measurement of the aspect, a YAP:Ce crystal scintillator with lithium or hydrogen converters and a photomultiplier was used. A plutonium-beryllium neutron source and horizontal neutron channel beams of the LVR-15 research reactor were used as neutron sources. The measurement confirmed the possibility to use the YAP:Ce scintillator for neutron radiation detection. The degree of discrimination between neutron and gamma radiation for different detection configurations was studied. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Neutron Detection Third Order Time Correlation

Neutron noise experiments on fissile materials are used to get information such as reactivity, fissile mass, neutron sources, prompt neutron lifetime. One of the more popular methods is based on correlated moments of the neutron counts distribution. The second correlated moment method originally proposed by Feynman was extended to the third order. In this paper we present the application of the third order correlation moments method to SILENE reactor measurements. The third order correlation moments method has been applied to analyse time list mode - subcritical measurements on SILENE reactor in order to evaluate the system subcriticality, The multiplication coefficient is obtained with large statistical uncertainties, but remains consistent with MCNP calculations. To reduce the experimental uncertainties longer measurement time and higher detector efficiency should be necessary. The systematic errors coming from the fission neutron data (moments of the fission neutron distributions) and point model formulas should also be investigated. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Wide band gap semiconductor NAND based neutron detection systems and methods

A wide band gap semiconductor NAND based neutron detection system includes a semiconductor layer comprising a wide band gap material with a neutron absorber material in the wide band gap material, and the semiconductor layer is the only layer of the wide band gap semiconductor NAND based neutron detection system fabricated with the neutron absorber material.

Preston, Jeffrey Robert↗

A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods

Here, we characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a 137 Cs source for energy calibration and a 252 Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is (30.2 ± 0.9)%, which is almost twice that of the PMT-based array, which we measure to be (16.9 ± 0.1)%.

47 OTHER INSTRUMENTATION↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Neutron detection of the Triga Mark III reactor, using nuclear track methodology

Nuclear Track Methodology (NTM), based on the neutron-proton interaction is one often employed alternative for neutron detection. In this paper we apply NTM to determine the Triga Mark III reactor operating power and neutron flux. The facility nuclear core, loaded with 85 Highly Enriched Uranium as fuel with control rods in a demineralized water pool, provide a neutron flux around 2 × 10{sup 12} n cm{sup −2} s{sup −1}, at the irradiation channel TO-2. The neutron field is measured at this channel, using Landauer{sup ®} PADC as neutron detection material, covered by 3 mm Plexiglas{sup ®} as converter. After exposure, plastic detectors were chemically etched to make observable the formed latent tracks induced by proton recoils. The track density was determined by a custom made Digital Image Analysis System. The resulting average nuclear track density shows a direct proportionality response for reactor power in the range 0.1-7 kW. We indicate several advantages of the technique including the possibility to calibrate the neutron flux density measured at low reactor power.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron detection using a current biased kinetic inductance detector

We demonstrate neutron detection using a solid state superconducting current biased kinetic inductance detector (CB-KID), which consists of a superconducting Nb meander line of 1 μm width and 40 nm thickness. {sup 10}B-enriched neutron absorber layer of 150 nm thickness is placed on top of the CB-KID. Our neutron detectors are able to operate in a wide superconducting region in the bias current–temperature diagram. This is in sharp contrast with our preceding current-biased transition edge detector, which can operate only in a narrow range just below the superconducting critical temperature. The full width at half maximum of the signals remains of the order of a few tens of ns, which confirms the high speed operation of our detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron detection using boron gallium nitride semiconductor material

In this study, we developed a new neutron-detection device using a boron gallium nitride (BGaN) semiconductor in which the B atom acts as a neutron converter. BGaN and gallium nitride (GaN) samples were grown by metal organic vapor phase epitaxy, and their radiation detection properties were evaluated. GaN exhibited good sensitivity to α-rays but poor sensitivity to γ-rays. Moreover, we confirmed that electrons were generated in the depletion layer under neutron irradiation. This resulted in a neutron-detection signal after α-rays were generated by the capture of neutrons by the B atoms. These results prove that BGaN is useful as a neutron-detecting semiconductor material.

36 MATERIALS SCIENCE↗

Neutron Detection Alternatives to 3He for National Security Applications

One of the main uses for 3He is in gas proportional counters for neutron detection. Large radiation detection systems deployed for homeland security and proliferation detection applications use such systems. Due to the large increase in use of 3He for homeland security and basic research, the supply has dwindled, and can no longer meet the demand. This has led to the search for an alternative technology to replace the use of 3He-based neutron detectors. In this paper, we review the testing of currently commercially available alternative technologies for neutron detection in large systems used in various national security applications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Safety analysis of high pressure 3He-filled micro-channels for thermal neutron detection.

This document is a safety analysis of a novel neutron detection technology developed by Sandia National Laboratories. This technology is comprised of devices with tiny channels containing high pressure {sup 3}He. These devices are further integrated into large scale neutron sensors. Modeling and preliminary device testing indicates that the time required to detect the presence of special nuclear materials may be reduced under optimal conditions by several orders of magnitude using this approach. Also, these devices make efficient use of our {sup 3}He supply by making individual devices more efficient and/or extending the our limited {sup 3}He supply. The safety of these high pressure devices has been a primary concern. We address these safety concerns for a flat panel configuration intended for thermal neutron detection. Ballistic impact tests using 3 g projectiles were performed on devices made from FR4, Silicon, and Parmax materials. In addition to impact testing, operational limits were determined by pressurizing the devices either to failure or until they unacceptably leaked. We found that (1) sympathetic or parasitic failure does not occur in pressurized FR4 devices (2) the Si devices exhibited benign brittle failure (sympathetic failure under pressure was not tested) and (3) the Parmax devices failed unacceptably. FR4 devices were filled to pressures up to 4000 + 100 psig, and the impacts were captured using a high speed camera. The brittle Si devices shattered, but were completely contained when wrapped in thin tape, while the ductile FR4 devices deformed only. Even at 4000 psi the energy density of the compressed gas appears to be insignificant compared to the impact caused by the incoming projectile. In conclusion, the current FR4 device design pressurized up to 4000 psi does not show evidence of sympathetic failure, and these devices are intrinsically safe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MHD-240 Neutron Detection Efficiency and Sensitivity Calibration

The neutron detection efficiency of the MHD-240 scintillation detector was measured at Ohio University Edwards Accelerator Laboratory. Pulsed broad-spectrum sources from the 27 Al(d,n) and 9 Be(d,n) reactions were used to produce the neutrons. The neutron time-of-flight technique was used to make an energy-differential efficiency measurement. The measurements were made in a low rate pulse mode. The pulse height distribution was also recorded, and the data were used to derive a neutron sensitivity that would be applicable in a high rate environment such as a critical assembly where the detector would be expected to operate in a current mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗