Validation of neutron-induced reactions on natural carbon using an active target at neutron energies up to 22 MeV at LANSCE

A single crystal chemical vapor deposited (sCVD) diamond detector is used as an active target to measure neutron-induced reactions on natural carbon using the neutrons produced by spallation, with a broad energy spectrum at LANSCE. Additionally, the neutron-induced reactions are detected in the diamond as low as E n = 400 keV and up to approximately 100 MeV. Relative cross sections for C 12 ( n , α 0 ) , C 12 ( n , p 0 ) , C 12 ( n , d 0 + p 1 ) , and C 13 ( n , α 0 ) are reported up to E n = 22 MeV and comparisons on detected pulse-height spectra and detector response of scattering reactions are made with GEANT4 simulations using the ENDF/B-VIII.0 evaluated nuclear data library up to 20 MeV. The results are compared with past experimental data, including other works that incorporate diamond detectors as an active carbon target. In addition, R-matrix calculations for the C 13 + n system are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Growth of Cd 0.9 Zn 0.1 Te 1-y Se y Single Crystals for Room Temperature Gamma-Ray Detection

Quaternary Cd 0.9 Zn 0.1 Te 1-y Sey (CZTS) single crystals, a novel room-temperature nuclear radiation detector semiconductor material, have been grown using a modified vertical Bridgman method (VBM) and a travelling heater method (THM). The percentage concentration of selenium in the VBM-grown crystal was 3% and that in the THM-grown crystal was 2%. While the THM Frisch collar detector (4.4 × 4.4 × 10.7 mm 3 ) produced a highly resolved pulse height spectra (PHS) with a resolution of ~1.06% for 662-keV gamma rays without any correction, the VBM-grown detector (10 × 10 × 2 mm 3 ) offered a high energy resolution of ~2% after application of a digital biparametric correction. The high-resolution performance of these detectors has been attributed to the addition of Se in the Cd 0.9 Zn 0.1 Te (CZT) matrix. Ab-initio calculations based on density functional theory (DFT) also confirmed that the addition of Se in the CZT matrix helps to reduce the formation of TeCd and the TeZn anti-sites. The VBM-grown crystals were characterized using powder x-ray diffraction (XRD) and energy dispersive x-ray spectroscopy (EDS). While XRD results revealed sharp diffraction peaks confirming the crystalline nature of the grown crystal, the EDS results confirmed the targeted stoichiometry of the elemental composition. The bulk resistivity of the grown crystal was calculated to be ~3 × 10 10 Ω-cm from current-voltage characteristics recorded at room temperature in a planar configuration, ensuring that the grown CZTS crystals have low dark current as required for detector-grade crystals.

42 ENGINEERING↗

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Additionally, key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrating Metal-Hydride and Gas-Detector for Tritium Gas Detection

Detection of trace amounts of environmental tritium is a challenging problem, driving the need for field-deployable systems that offer high sensitivity, selectivity, and minimal false positives. We present a technique for high-sensitivity, high-selectivity tritium measurement, which integrates metal-hydride and gas-detector concepts into a compact field-deployable tritium sensor. A hydrogen-storage metal embedded in a gas proportional counter selectively absorbs protium (1H)/tritium (3H), which are subsequently released into the counter volume with a reduced radiation background. Ionizations induced by 3H beta particles are then measured in proportional counting mode, achieving high detection efficiency. Preliminary studies conducted with palladium (Pd) thin films coated on stainless-steel substrates demonstrated 3H absorption and metal-tritide formation, followed by 3H desorption upon heating the metal-tritide. These processes were confirmed using activity concentrations measured by a commercial tritium monitor and pulse height spectra acquired from a custom-built detector.

Gas-proportional counter↗

MHD-240 Neutron Detection Efficiency and Sensitivity Calibration

The neutron detection efficiency of the MHD-240 scintillation detector was measured at Ohio University Edwards Accelerator Laboratory. Pulsed broad-spectrum sources from the 27 Al(d,n) and 9 Be(d,n) reactions were used to produce the neutrons. The neutron time-of-flight technique was used to make an energy-differential efficiency measurement. The measurements were made in a low rate pulse mode. The pulse height distribution was also recorded, and the data were used to derive a neutron sensitivity that would be applicable in a high rate environment such as a critical assembly where the detector would be expected to operate in a current mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of CsI:Tl Cyrstal with a Spectrum Matching Photomultiplier Tube

This report documents an effort to improve the energy resolution for a thallium doped cesium iodide (CsI:T1) scintillator paired with a spectrum matching photomultiplier tube (PMT). A comparison of the differences in the pulse height spectra from thallium doped (CsI:T1) and sodium doped (CsI:Na) single crystals with PMTs of different spectrum responses was performed. Results show that energy resolution of the detector only improves 0.5% at room temperature when these scintillators are coupled with a spectrum matching PMT. Based on a spectrum matching PMT, the best results for energy resolution are 7.39% and 7.88% for CsI:T1 and CsI:Na scintillators, respectively. The improvement is primarily attributed to the increase of photon statistics from the increase of photons (N) being detected in the spectrum matching PMT. Other factors, such as optical quantum yield and non-proportionality of the CsI:T1 and CsI:Na crystals, that can affect the energy resolution were also studied and reported. The results indicate that although the use of a spectrum matching PMT enhances the photon statistics, it also exacerbates the nonproportionality response. Consequently, a promised improvement on energy resolution due solely to photon statistics was not fully realized.

36 MATERIALS SCIENCE↗

A comprehensive final summary of the MCNP calculations performed concerning the UW 137 Cs release event

This document combines and supersedes earlier reports (e.g. LA-UR-19-32358 and LA-UR-20- 22216) that discussed MCNP-calculated conversion factors (count rate per unit activity per unit area) for collimated 2”x2” NaI detectors (Ludlum model 44-10 and Thermo model SPA3) in contact with various surfaces of interest to the University of Washington 137 Cs release event. These surfaces include: Exterior surface of round and rectangular ducts, Exterior surface of outdoor brick work, Exterior surface of cast iron pipes, Exterior surface of an O 2 filter assembly For each surface, the calculated conversion factors allowed inferences on 137 Cs activity on interior surfaces based on exterior contact measurements of the 662 keV photopeak count rate. The MCNP calculations included the effect of attached collimators (i.e. either a Pb/Sb-based Ludlum or a W-based “Rees” model) on detector response. As a consequence, the conversion factors only apply to the appropriate collimated 2”x2” NaI detector operated in pulse height analysis (PHA) mode. Other assumptions affecting the calculations and valid application of the conversion factors will be outlined below.

54 ENVIRONMENTAL SCIENCES↗

(U) Using the MCNP6 Perturbation Capability for Source Nuclide Density Sensitivities

The Taylor series (differential operator) perturbation method, as implemented in the PERT capability in MCNP6 (Ref. 1), can be used for first- and second-order sensitivity analyses in fixed-source problems. Unfortunately, the PERT capability does not yet work with point-detector (F5) or pulse-height (F8) tallies. Also, the second-order Taylor series term lacks the cross terms that would allow the calculation of mixed sensitivities. Finally, the PERT capability does not compute any sensitivities involving the source in a fixed-source problem. When neutrons or gamma rays are emitted due to radioactive decay, the source rate density depends intrinsically on the nuclide densities in the source material. When the PERT capability in MCNP6 is used to compute sensitivities of a response to nuclide and material densities, those sensitivities do not include the effect of the source.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coincident Capture through Post-processing PTRAC [Slides]

This presentation discusses the new PTRAC capabilities and workflows. The PTRAC capability in MCNP6.3 has seen a massive overhaul since MCNP6.2. The new HDF5 file format allows for both MPI- and thread-based parallelism. MCNPTools has been updated to handle the new HDF5 PTRAC format and is now open sourced on GitHub. Built-in capabilities, such as the pulse-height tally coincident capture special treatment, can largely be replicated through separate postprocessing scripts that leverage both PTRAC and MCNPTools. This allows for greater flexibility in user-specified and controlled detector response functionality, ultimately using the MCNP code for what it is best at (i.e., particle transport).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determining the 193 m Ir/ 192 Ir ratio from high-resolution X-ray measurements

Two pellets of iridium salt were irradiated at the center of the Flattop critical assembly, one at low neutron flux and the other at high flux. After that two counting samples were prepared from each pellet following a given chemical procedure. Measurements of the four counting samples were carried out with two high-resolution silicon drift detectors for over a year. Pulse height spectra of the L→M X-rays from 193 m Ir and 192 Ir were approximated with a Voigt function and the ratio of produced 193 m Ir and 192 Ir nuclei obtained. The 193 m Ir/ 192 Ir ratios from each measured spectrum are compared to identify possible systematic deviations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ↗

Total kinetic energy release in the fast neutron induced fission of actinide nuclei

The total kinetic energy release and fission mass distributions for the fast neutron (En = 3–100 MeV) induced fission of 232 Th, 233 U, 235 U, 237 Np, 239 Pu, 240 Pu, and 242 Pu have been measured using the LANSCE facility. The neutron energies were deduced from time-of- flight measurements. The fission fragments were detected using Si PIN diode detectors, giving us the fragment energies. The actinide targets were made by vapor deposition leading to high-quality targets, that were thin and uniform with reduced impurities. Corrections were made to the data for pulse height defect and the fragment energy loss in the target and its backing. The TKE distributions were Gaussian in shape and their mean value as a function of incoming neutron energy could be fitted with second order polynomials. In the case of 233 U and 235 U, our measurements agree with prior work. Our measurements for 232 Th are unique. Our data agree with Viola scaling. The constant position of the heavy mass peak is interpreted as being due to the influence of the N = 88 and Z = 50 shells. The GEF model predictions agree with the data in general as do the CGMF model predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probing the bandgap and effects of t-BN domains in h-BN neutron detectors

Thermal neutron detectors in a lateral scheme were fabricated from a 70μm thick freestanding B-10 enriched hexagonal BN (h- 10 BN). Two sets of channel peaks corresponding to the neutron capture by 10 B occurring in h- 10 BN comprising turbostratic domains (t- 10 BN) have been recognized in the nuclear reaction pulsed height spectrum, from which a bandgap of 5.5 eV was directly deduced for t- 10 BN. Improved device performance over the prior state-of-the-art implies that the transport properties in the lateral plane of t-BN domains are sufficiently good and their presence in h-BN is not a showstopper for the further advancement of h-BN detector technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

Imaging Based Detector with Efficient Scintillators for Neutron Diffraction Measurements

The Anger Camera developed by the detector group at the Oak Ridge National Laboratory was utilized for the present work for its unique advantage of employing multiple modules to obtain large active measurement area for detecting diffracted/scattered thermal neutrons. Considering the relatively small flux associated with diffracted/scattered neutrons, suitable efficiency with high spatial resolution is a requirement for utilizing two-dimensional imaging detectors. The potential to implement pulse shape (in addition to pulse height) discrimination-based scintillators further enhances the ability to detect diffracted neutrons with improved signal to noise ratio. In this paper, initial results associated with 6Li glass-based scintillator will be presented. The authors explored the feasibility of using this system to detect and quantify diffraction peaks and peak shifts at the Neutron Residual Stress Facility (NRSF2), High Flux Isotope Reactor (HFIR) in the Oak Ridge National Laboratory (ORNL). Suitable camera mounting and shielding had to be developed. Reference measurements using polycrystalline powders with known atomic planar spacing will be discussed along with measurement settings associated with expected resolution for peak shift measurements. Initial results are promising and demonstrate that a suitable scintillation-based neutron detecting system is viable for residual stress-based diffraction measurements. Small area detectors are also feasible with suitable consideration to scattering volume and distance to detector.

Seals, Matthew↗