At least 55 records · Page 3

Further Support of the Development of Advanced Multilayer Optics Coatings for X-Ray Imaging

The Smithsonian Astrophysical Observatory (SAO) is working with Lawrence Livermore National Laboratory (LLNL) to develop Wolter-I optics for x-ray imaging applications at energies of 15-50 keV and above for National Nuclear Security Administration (NNSA) facilities. SAO work includes R&D on advanced multilayer coatings as well as fabrication and testing of Wolter multilayer coated optics. It also includes delivery of custom 3.05-meter focal length Wolter optics with response at energies of interest to Sandia National Laboratories and LLNL. The optics are fabricated using an electroform nickel replication technique which has been used to fabricate optics for X-ray astronomy satellites over the past two decades. This technique starts with a figured, polished mandrel from which the optics are replicated. To carry this technique over to fabricate optics for NNSA facilities, several additional barriers had to be overcome to deposit multilayer coatings on integral optics with radii as small as 25 mm. These breakthroughs allow fabrication of optics which meet the spatial and spectral specifications required by NNSA facilities. During this present contract period SAO delivered four custom optics to LLNL with spectral response at or near the Kα line of silver, 22.16 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tin removal by an annular surface wave plasma antenna in an extreme ultraviolet lithography source

Tin contamination of the collector mirror surface remains one of the crucial issues of EUV (Extreme Ultraviolet) sources, directly impacting the availability of the tool. Hydrogen plasma-based tin removal processes employ hydrogen radicals and ions to interact with tin deposits to form gaseous tin hydride (SnH 4 ), which can be removed through pumping. An annular surface wave plasma (SWP) source developed at the University of Illinois—Urbana Champaign is integrated into the cone and perimeter of the collection mirror for in situ tin removal. The SWP is characterized by high ion and radical densities, low electron temperature, and local generation where etching is needed. This method has the potential to significantly reduce downtime and increase mirror lifetime. Radical probe measurements show hydrogen radical densities in the order of 10 19 m -3 , while Langmuir probe measurements show electron temperatures of up to 6 eV and plasma densities on the order of 10 17–18 m -3 . The generated ions are essential to the tin cleaning and have sufficiently low energy to cause no damage to the collector capping layer. Tin etch rates of up to 270 nm/min were observed in a variety of experimental conditions, including various powers, pressures, flowrates, and temperatures. In conclusion, the high etch rates demonstrated in this study exceed the expected contamination rate of the EUV source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oceanographic biooptical profiling system

A new oceanographic instrument to measure underwater optical, biological, and physical properties has been designed, built, and used extensively at sea. The new instrument system is a significant advance that permits optimum sampling strategies using ship, aircraft, and satellite optical sensors for ocean research. The design criteria for the biooptical profiling system included the rapid acquisition of data to accommodate shipboard synoptic sampling; the measurement of the necessary parameters for providing appropriate contemporaneous surface data for remote sensors; the compatibility of the data acquisition system with conventional conductivity temperature depth-type cables and winches on the oceanographic fleet; the capability of real-time display of data along with rapid preliminary data reduction at sea. The primary instrument package in this profiling system is a new microprocessor controlled multiwavelength spectroradiometer. A description of the instrument and examples of data are presented.

Smith, R. C.↗

Complete Stokes vector analysis with a compact, portable rotating waveplate polarimeter

Accurate calibration of polarization dependent optical elements is often necessary in optical experiments. A versatile polarimeter device to measure the polarization state of light is a valuable tool in these experiments. Here we report a rotating waveplate-based polarimeter capable of complete Stokes vector analysis of collimated light. Calibration of the device allows accurate measurements over a range of wavelengths, with a bandwidth of >30 nm in this implementation. A photo-interrupter trigger system supplies the phase information necessary for full determination of the Stokes vector. An Arduino microcontroller performs rapid analysis and displays the results on a liquid crystal display. The polarimeter is compact and can be placed anywhere on an optical table on a single standard post. The components to construct the device are only a fraction of the cost of commercially available devices while the accuracy and precision of the measurements are of the same order of magnitude.

47 OTHER INSTRUMENTATION↗

Raster Thomson scattering in large-scale laser plasmas produced at high repetition rate

We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1 Hz). The Thomson scattering diagnostic matches this high repetition rate. Unlike previous work performed in single shots at much higher energies, the instrument allows point measurements anywhere inside the plasma by automatically translating the scattering volume using motorized stages as the experiment is repeated at 1 Hz. Measured densities around 4×10 16 cm -3 and temperatures around 7 eV result in a scattering parameter near unity, depending on the distance from the target. The measured spectra show the transition from collective scattering close to the target to non-collective scattering at larger distances. Densities obtained by fitting the weakly collective spectra agree to within 10% with an irradiance calibration performed via Raman scattering in nitrogen.

47 OTHER INSTRUMENTATION↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Deep learning enables nanoscale X-ray 3D imaging with limited data

Deep neural network can greatly improve tomography reconstruction with limited data. A recent effort of combining ptycho-tomography model with the 3D U-net demonstrated a significant reduction in both the number of projections and computation time, and showed its potential for integrated circuit imaging that requires high-resolution and fast measurement speed.

47 OTHER INSTRUMENTATION↗

Semiconductor yields sensitive thermometry

Here, the strongly temperature-dependent band-edge absorption from gallium arsenide enables an optical thermometer with nanokelvin temperature resolution and microscale spatial resolution.

47 OTHER INSTRUMENTATION↗

New application of hyperspectral imaging to steady-state plasma observations

A new application of hyperspectral imaging (HSI) to steady-state plasma emission observations is proposed because of its prominent feature: an HSI camera records a two-dimensional image, and each spatial pixel contains spectral data typically with more than a hundred bands, while conventional digital cameras have only three bands. The characterization of an HSI camera (Specim IQ) has been performed during steady-state plasma–material interaction experiments using the linear plasma device PISCES-A. By easily subtracting the background/continuum emission in contrast to conventional filter cameras, two-dimensional images of multiple emission lines at different wavelengths are simultaneously obtained during a single measurement, demonstrating the advantage in plasma emission observations.

47 OTHER INSTRUMENTATION↗

A high transmission tender X-ray monochromator employing a matched pair of multilayer grating and mirror

It is now well established that multilayer coated gratings may offer high diffraction efficiencies over the tender X-ray range, from about 1 keV to 5 keV, covering the gap between single layer coated grating monochromators and crystal monochromators. Nevertheless, few beamlines in the world are using such gratings in their monochromator. The successful implementation of a multilayer grating monochromator requires producing a matched pair of a multilayer grating and a multilayer mirror, and this matching is not straightforward as it must account for different incidence angles and refraction effects on each element. Here we review the realization of the multilayer grating monochromator of the SIRIUS beamline which has been successfully in service for several years. We show how, by alternating computer simulation with our diffraction code and measurements, we could optimize the monochromator transmission on a very wide energy range. After the grating was coated, it was found that the angle of optimal efficiency versus photon energy was significantly different from what was predicted by a simple conformal model of binary layers. Layer interdiffusion and profile smoothing during the deposition process must be added to the multilayer model to reproduce the measured data. The critical adjustment of the mirror multilayer period is achieved by the lateral translation of the mirror, which was given a small transverse period gradient. The monochromator is thus providing high transmission efficiency in the 1 to 5 keV energy range, more than 30% over 2.5 keV and up to 46% at 4.6 keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced Carbon Dioxide Uptake in Drilled Hollow Core Fibers for Raman Spectroscopy

Fiber-based Raman spectroscopy enhances the Raman signal by maximizing the overlap of the optical field and the gas species. However, filling the hollow-core fiber (HCF) with gas requires time that is dependent on the fiber core diameter, fiber length, and pressure of the gas. At ambient pressure, the fiber gas uptake is driven by diffusion into the fiber ends, severely limiting the response time of the system. By laser drilling access holes to the core along the length of the fiber, the uptake time of the gas is reduced, improving the system response time. In this work, we study the carbon dioxide (CO 2 ) sensor dynamics based on Raman signal intensity generated in HCFs. The signal intensity versus gas concentration is characterized by controlling the CO 2 concentration in the surrounding environment of the fiber. Next, we characterize the gas uptake time in HCFs as a function of fiber length. Finally, we optimize the access hole configuration along the fiber, demonstrating reduced sensor uptake time by a factor of three.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Program Overview Laboratory Directed Research and Development FY2020 (Annual Report)

Throughout this year’s report, we highlight how the LDRD program invests in ideas that make the world a safer place. We review key accomplishments and performance indicators, and we share snapshots of some of our talented staff. I also encourage you to visit our LDRD website and learn more about the 244 projects that we supported during fiscal year 2020. Looking to the future, I am confident that LDRD investments will continue to help LLNL remain at the forefront of innovative research.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗