Los Alamos National Laboratory Waste Program Review Data for FY23 Q3 QPR
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
This document specifies the functional requirements for the High Luminosity LHC (HL-LHC, or HiLumi LHC) MQXFA Magnets. Twenty (20) of these magnets shall be fabricated and delivered to CERN by the U.S. HiLumi project as part to the U.S. contributions to the LHC High Luminosity Upgrade. These magnets are the quadrupole magnetic components of the HL-LHC Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). Two MQXFA magnets are installed in each Q1 or Q3. Since these magnets are identical whether installed in Q1 or Q3, the functional requirements are identical for all MQXFA magnets.
The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.
The 11 GeV Super High Momentum Spectrometer (SHMS) of Hall C, part of the recent 12 GeV accelerator Upgrade at Jefferson Lab, was successfully commissioned in 2017. Fast current discharges of the SHMS Q2, Q3 quadrupoles and dipole superconducting magnets experienced some level of operational difficulty, during commissioning and normal operation. Measurements and analyses demonstrate that the fast current discharge leads to substantial AC losses in the conductor and subsequently triggers a quench-back effect. The details of the measurements and analyses have been reported previously. This paper focuses on the test results of the magnets using a reduced value of the protection dump resistor for each magnet to lower the current decay rate. Finally, the test results confirmed that the reduced dump resistances eliminated the quench-back effect for the SHMS Q2, Q3 and Dipole magnets, thus improving their cryogenic operability.
The future High Luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN will include the low-beta inner triplets (Q1, Q2a/b, Q3) for two LHC insertion regions. The Q1, Q3 components consist of eight 10 m-long LMQXFA cryo-assemblies fabricated by the HL-LHC Accelerator Upgrade Project. Each LMQXFA Cold mass contains two Nb 3 Sn magnets connected in series. A stainless-steel shell is welded around the two magnets before the insertion into the cryostat. There is a limit on how much coil preload increase induced by the shell welding is allowed. Distributed Rayleigh backscattering fiber optics sensors were used for the first time to obtain a strain map over a wide area of a Nb 3 Sn magnet cold mass shell. Finally, data were collected during welding of the first LMQXFA cold mass and the results confirm that the increase of the coil pole azimuthal pre-stress after welding do not exceed requirements.
New high field and large-aperture quadrupole magnets for the low-beta inner triplets (Q1, Q2, Q3) have been built and tested as part of the high-luminosity upgrade of the Large Hadron Collider (HL-LHC). These new quadrupole magnets are based on Nb3Sn superconducting technology. The US Accelerator Upgrade Project (US-AUP) is producing the Q1 and Q3 Cryo-Assemblies: a pair of ~5 m long magnet structures installed in a stainless-steel helium vessel (Cold Mass) and surrounded by cryostat shields, piping, and a vacuum vessel. In conclusion, this paper gives an overview of the design, production, and the results of the horizontal test of the first pre-series Q1/Q3 Cryo-Assembly.
This assessment analyzes Environment, Safety, and Health (ES&H) occurrences and Non-Occurrence Trackable Events (NOTEs) from fiscal year (FY) 2021. For this report, assessors used three primary methods for categorizing occurrence and NOTE data: issue categorization, DOE reporting criteria groups, and DOE cause codes. The FY 2021 Q1 occurrence and NOTE total was the lowest since this type of analysis began in FY 2018 Q4, following a downward trend from the FY 2019 Q3 high point. The FY 2021 Q2 occurrence and NOTE total was nearly double the FY 2021 Q1 total; occurrence totals declined slightly in Q3 and Q4, while NOTE totals remained the same. NOTEs in each of the final three quarters were more than double the amount from Q1. This assessment resulted in one observation. As COVID-19 vaccination rates increase and COVID 19 impacts on operations decrease, the number of workers on-site and the amount of activity-level work will increase. With these changes, focused attention on the following areas related to work planning and controls may reduce the probability of future events, hazard identification and analysis, compliance with standards, formality of operations, and job scoping.
The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, manufacturing and test of the Q1/Q3 Cold Masses and the complete MQXFA magnets. CERN provides the cryostat components and is responsible for integration and installation in HL LHC. The MQXFA quadrupoles have 150 mm aperture, 4.2 m magnetic length, nominal gradient of 132.2 T/m, and coil peak field of 11.3 T. They use Nb_3Sn conductor and a support structure made of segmented aluminum shells pre-loaded by using bladders and keys. This report presents the final design of the MQXFA quadrupole magnets.
In partial fulfillment of the Annual (SMART) Milestone for Q3 of FY22, this report details the results of the peer review process carried out on the use and function of Tethys Engineering. During Q3 of FY22, Pacific Northwest National Laboratory (PNNL) solicited broad feedback from a self-selected subset of the marine energy community on the use and effectiveness of key pages on Tethys Engineering. A total of 39 responses were collected from the greater marine energy community.
For the Hi-Lumi LHC Upgrade (HL-LHC) new high field and large-aperture quadrupole magnets for the low-beta inner triplets (Q1, Q2, Q3) are being built. These new quadrupole magnets are based on Nb3Sn superconducting technology. As part of the US-HiLumi Accelerator Upgrade Project (AUP) ten Cryostat Assemblies (LQXFA) for Q1 and Q3 replacement will be built, tested and delivered to CERN. The first of the LQXFA was assembled and tested at Fermi National Accelerator Laboratory (FNAL) during the fall of 2022 and spring 2023. We will present the integration work of the Cold Mass assembly into the Cryostat Kit provided by CERN. Each Cold Mass contains two trained MQXFA magnets of ~ 5 m length installed in a stainless-steel helium pressure vessel. The Cold Mass will be surrounded by cryostat shields, piping, and vacuum vessel. We will discuss the metrology survey results and present the LQXFA measurements prior testing at the Fermilab Magnet Test facility and lessons learned.
For the HiLumi LHC Upgrade (HL-LHC), new high field and large-aperture quadrupole magnets for the low-beta inner triplets (Q1, Q2, Q3) are being built. These new quadrupole magnets are based on Nb3Sn superconducting technology. As part of the US-HiLumi Accelerator Upgrade Project (AUP), ten Cryostat Assemblies (LQXFA) for Q1 and Q3 replacement will be built, tested, and delivered to CERN. The first LQXFA was assembled and tested at Fermi National Accelerator Laboratory (FNAL) during fall 2022 and spring/summer 2023, respectively. This paper summarizes the assembly process and experience of the first LQXFA Cryostat Assembly at FNAL.
This is the Q3 summary for the SDRD Project titled "Fast Methods for Limited-Angle Tomography"
Occupant-Centric Control and Operation (OCC) represents a transformative approach to building management, integrating sensing of indoor environmental quality, occupant presence, and occupant-building interactions. These data are then utilized to optimize both operational efficiency and occupant comfort. This paper summarizes the findings from the IEA-EBC Annex 79 research program's subtask on real world implementations of OCC during the past 5 years. First, in Q1 and Q2, we provide a definition and categorization of OCC. Q3 addresses the role of building operators for OCC, while Q4 describes the implications for designers. Then, Q5 and Q6 discuss the role and possibilities of OCC for load flexibility, and for pandemic induced paradigm shifts in the built environment, respectively. In Q7, we provide a taxonomy and selection process of OCC, while Q8 details real world implementation case studies. Finally, Q9 explains the limits of OCC, and Q10 provides a vision for future research opportunities. Furthermore, our findings offer valuable insights for researchers, practitioners, and policy makers, contributing to the ongoing discourse on the future of building operations management.
Silicon is one of the most earth abundant elements, and thus, the fate and reactivity of silicate materials are often important for various energy and environmental technologies including carbon sequestration, where CO 2 is captured and stored as a thermodynamically stable solid carbonate phase. Thus, understanding the structures and chemistries of different silicate phases has become an important research aim. Here in this study, the changes in the silicate structures (Q 0 –Q 4 ) of heat-treated Mg-bearing mineral (serpentine) exposed to a CO 2 -water system (carbonic acid) was investigated using 29 Si MAS NMR, XRPD and ICP-OES and the identified structures were employed to explain complex leaching behaviors of silicate materials. The 29 Si MAS NMR and XRPD analysis indicated that the heat-treated serpentine is a mixture of amorphous (Q 1 : dehydroxylate I, Q 2 : enstatite, Q 4 : silica) and crystalline (Q 0 : forsterite, Q 3 : dehydroxylate II and serpentine) phase, while natural serpentine mineral has single crystalline Q 3 silicate structure. The leaching experiments showed that both Mg and Si in the amorphous silicate structures (Q 1 : dehydroxylate I, Q 2 : enstatite) are more soluble than those in crystalline phase (Q 0 : forsterite, Q 3 : dehydroxylate II and serpentine). Therefore, tuning the silicate structure towards Q 1 and Q 2 would significantly improve carbon sequestration potential of silicate minerals, whereas silicate materials with Q 3 structure would provide great chemical stabilities in acidic conditions. The solubilities of silicate structures were in the order of Q 1 (dehydroxylate I) > Q2 (enstatite) >> Q0 (forsterite) > Q3 (dehydroxylate II) > Q 3 (serpentine) and this finding can be used to better design a wide range of energy and environmental materials and reaction systems.
In contact with water, glass transforms into amorphous and porous structures called gels. A simulation method based on classical molecular dynamics is proposed here to mimic “dry” gels forming from initial oxide glass structures. Six glass compositions were investigated. Two behaviours were evidenced depending on the initial glass composition, and in particular on the quantity of elements removed. If a large quantity of soluble elements (B, Na) was removed, it induced an increase in the average pore size within the gels, and the time needed to stabilise the gel structure increased because more local atomic rearrangements occurred. The gel network displayed a higher proportion of Si-Q4 at the expense of Si-Q3 and a lower average ring size compared to the glass network, irrespective of the glass composition. Surface effects were also highlighted in the dry gels, such as the presence of 3-coordinated Al and a decrease in the average angle Si-O-Si and Al-O-Al. Our findings will be compared to both wet gels and experimental data in further studies, to help find the best procedure to simulate such structures.
The optimal macronutrient composition of the diet is controversial and many adults attempt to regulate the intake of specific macronutrients for various health-related reasons. The objective was to compare stability and ranges of intakes of different macronutrients across diverse adult populations in the USA and globally. US dietary intake data from NHANES 2009–2014 were used to determine macronutrient intake as a percentage of total energy intake. Variability in macronutrient intake was estimated by calculating the difference between 75th and 25th percentile (Q3–Q1) IQRs of macronutrient intake distributions. In addition, intake data from 13 other countries with per capita gross domestic product (GDP) over $10,000 US dollars (USD) were used to assess variability of intake internationally since there are large differences in types of foods consumed in different countries. Protein, carbohydrate, and fat intake (NHANES 2009–2014) was 15.7 ± 0.1, 48.1 ± 0.1, and 32.9 ± 0.1% kcal, respectively, in US adults. The IQR of protein intake distribution (3.73 ± 0.11% kcal) was 41% of carbohydrate intake distribution (9.18 ± 0.20% kcal) and 58% of fat intake distribution (6.40 ± 0.14% kcal). The IQRs of carbohydrate and fat intake distributions were significantly (P <0.01) influenced by age and race; however, the IQR of protein intake was not associated with demographic and lifestyle factors including sex, race, income, physical activity, and body weight. International mean protein intake was 16.3 ± 0.2% kcal, similar to US intake, and there was less variation in protein than carbohydrate or fat intake. Protein intake of the US population and multiple international populations, regardless of demographic and lifestyle factors, was consistently ~16% of total energy, suggesting biological control mechanism(s) tightly regulate protein intake and, consequently, influence intake of other macronutrients and food constituents. Substantial differences in intake of the other macronutrients observed in US and international populations had little influence on protein intake. This trial was registered at the ISRCTN registry as ISRCTN46157745
The High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) is approaching the production phase of the US-contributed Q1 and Q3 Interaction Region Quadrupoles (MQXFA). The structures for the MQXFA prototypes were design and inspected by the US-LARP (LHC Accelerator Research Program), AUP developed criteria, which will be used for the pre-series structures. As the first two full-length prototypes with 4.2 m magnetic length, MQXFAP1 and MQXFAP2, were designed and assembled at Lawrence Berkeley National Laboratory (LBNL), and tested at Brookhaven National Laboratory (BNL). The end aluminum short shell of MQXFAP2 was fractured along the shell length during the test, and tests were stopped. Analytical and Finite Element analysis were performed in light of the graded procedure defined in the Structure Design Criteria to investigate the fracture failure for MQXFAP2. In this paper, we report the fracture analysis of the current shell design, including the elasto-plastic simulations with submodel technique, and calculations with Linear Elastic Fracture Mechanics (LEFM). Test material properties are also presented. The results of this analysis explain why the end shell of MQXFAP2 failed, and suggest fillets on the end shell notches to meet the margin specified in the Structural Design Criteria.
The US Accelerator Upgrade for the HiLumi-LHC (US-HL-LHC AUP) project and CERN are designing and fabricating superconducting quadrupole magnets for the interaction regions of the High Luminosity Large Hadron Collider (HLLHC). The triplet is made of three optical elements: Q1, Q2, and Q3. The Nb3Sn quadrupole magnets operate in superfluid He at 1.9 K with a nominal field gradient of 132.6 T/m. The three inner triplet elements are connected together with superconducting buses. The design and fabrication of the through and local buses is carried out at Applied Physics and Superconducting Technology Division (APS-TD) at Fermilab (FNAL). This paper reports the characterization of the bus-bar thermoelectric properties. The bus was tested with a short Nb3Sn magnet (MQXFS1e) in the vertical test facility of the APS-TD at FNAL. The test demonstrated that the bus design is adequate since no spontaneous quench took place up to 17.87 kA current value. Quench propagation velocities were investigated over a range of currents that is typical for accelerator superconducting magnets. Temperature margins were found above that required for the Hi- Lumi triplet bus. The design guarantees the protection of the bus at operational current value according to the quench detection voltage threshold (100 mV) established for the Hi-Lumi LHC interaction region.