DOE OSTI · 2349037
AUP First Pre-Series Cryo-Assembly Design Production and Test Overview
Abstract
New high field and large-aperture quadrupole magnets for the low-beta inner triplets (Q1, Q2, Q3) have been built and tested as part of the high-luminosity upgrade of the Large Hadron Collider (HL-LHC). These new quadrupole magnets are based on Nb3Sn superconducting technology. The US Accelerator Upgrade Project (US-AUP) is producing the Q1 and Q3 Cryo-Assemblies: a pair of ~5 m long magnet structures installed in a stainless-steel helium vessel (Cold Mass) and surrounded by cryostat shields, piping, and a vacuum vessel. In conclusion, this paper gives an overview of the design, production, and the results of the horizontal test of the first pre-series Q1/Q3 Cryo-Assembly.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Feher, Sandor, Ambrosio, G., Apollinari, G., Baldini, M., Bossert, R., Carcagno, R., Chlachidze, G., DiMarco, J., Rabehl, R., Stoynev, S., Strauss, T., Vouris, A., Prin, H., Ramos, D., Todesco, E., Ferracin, P., Vallone, G.. 2024-05-20. AUP First Pre-Series Cryo-Assembly Design Production and Test Overview. https://doi.org/10.1109/tasc.2024.3379173