Velocity measurements of microwave ultrasonic waves in quartz.
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Experimental and theoretical examinations were performed of the longitudinal velocity characteristics of waves in trilaminar and encapsulated waveguides. The study was confined to waveguides with core material that featured transverse wave velocities much worse than the longitudinal wave velocities. The velocities were obtained using a dispersion equation, with consideration given to both the core and encapsulant. Asymptotic velocities were also calculated for bending and twisting in trilaminar waveguides. Trials were run with bimetallic waveguides for comparison with the theoretical predictions. Good agreement was found between the predicted velocity of the propagation of the fundamental mode and the measured velocities. The method was calculated valid for modes above four, confirming that the data were contained in either the core or outer layer, and were unsensitive to the encapsulant.
The size, shape, and orientation of damage correlates well between the polar backscatter technique and the deply technique. There is good quantitative correlation between the areas of damage indicated by the two techniques. These results suggest that the polar backscatter technique is sensitive to specific orientations of damage. The polar backscatter technique provides a good qualitative image of the size and shape of the largest zone of damage in each of the principal orientations. A quantitative estimate of the extent of these largest damage zones is obtained from the polar backscatter technique. The selective sensitivity of polar backscatter provides a useful tool for further studies of the mechanisms of impact damage in graphite fiber reinforced composite laminates.
The effects of nonlinear elasticity on energy flux deviation in undirectional gr/ep composites are examined. The shift in the flux deviation is modeled using acoustoelasticity theory and the second- and third-order elastic stiffness coefficients for T300/5208 gr/ep. Two conditions of applied uniaxial stress are considered. In the first case, the direction of applied uniaxial stress was along the fiber axis (x3), while in the second case it was perpendicular to the fiber axis along the laminate stacking direction (x1). For both conditions, the change in the energy flux deviation angle from the condition of zero applied stress is computed over the range of propagation directions of 0 to 60 deg from the fiber axis at two-degree intervals. A positive flux deviation angle implies the energy deviates away from the fiber direction toward the x1 axis, while a negative deviation means that the energy deviates toward the fibers. Over this range of fiber orientation angles, the energy of the quasi-longitudinal and pure mode transverse waves deviates toward the fibers, while that of the quasi-transverse mode deviates away from the fibers.
Automated ultrasonic inspection system includes dry couplant pad attached to ultrasonic transducer. Designed to be mounted on robot arm in automated manufacturing (robotic welding) work cell. Between, during, or after manufacturing operations, robot scans ultrasonic transducer along workpiece. Workpiece reworked in place, if necessary. In principle, computer program controlling inspection overlaid on program controlling welding operations.
Effective treatment of serious burns is dependent on early recognition of the extent of dead tissue and its removal to minimize the risk of infection and hasten healing. To meet the need for precise determination of burn depth, two physicists from Langley's Nondestructive Measurement Science Branch in cooperation with the Medical College of Virginia, Richmond, the University of Aberdeen, Scotland, and the NASA Technology Application Team, Research Triangle Institute, developed a prototype system that used ultrasound technology (originally developed as a means of detecting microscopic flaws in materials) for immediate assessment of burn depth. The system was commercialized by Westminster Supra Scanner, Inc., Orangeburg, NY, is produced under a NASA license, and was granted Food and Drug Administration approval in December 1990. It can be applied to the diagnosis of lymphatic disorders.
Light diffraction from ultrasound, which can be used to investigate nonlinear acoustic phenomena in liquids, is reported for wave amplitudes larger than that typically reported in the literature. Large amplitude waves result in waveform distortion due to the nonlinearity of the medium that generates harmonics and produces asymmetries in the light diffraction pattern. For standing waves with amplitudes above a threshold value, subharmonics are generated in addition to the harmonics and produce additional diffraction orders of the incident light. With increasing drive amplitude above the threshold a cascade of period-doubling subharmonics are generated, terminating in a region characterized by a random, incoherent (chaotic) diffraction pattern. To explain the experimental results a toy model is introduced, which is derived from traveling wave solutions of the nonlinear wave equation corresponding to the fundamental and second harmonic standing waves. The toy model reduces the nonlinear partial differential equation to a mathematically more tractable nonlinear ordinary differential equation. The model predicts the experimentally observed cascade of period-doubling subharmonics terminating in chaos that occurs with increasing drive amplitudes above the threshold value. The calculated threshold amplitude is consistent with the value estimated from the experimental data.
The leaky Lamb wave (LLW) technique is approaching a maturity level that is making it an attactive quantitative NDE tool for composites and bonded joints.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Ultrasonic rotary motors are being developed as acutators for miniature spacecraft insturments and subsystems. The technology that has emerged in commercial products requires rigorous analytical tools for effective design of such motors. An analytical model was developed to examine the excitation of flexural plate wave traveling in rotary piezoelectrically actuated motor.
Ultrasonic rotary motors have the potential to meet this NASA need and they are developed as actuators for miniature telerobotic applications.
Nondestructive evaluation (NDE) is considered as a means to detect the energy release mechanism of defects and the interaction of microstructures within materials with sound waves and/or ultrasonic waves. Ultrasonic inspection involves the frequency range 20 kHz-1 GHz with amplitudes depending on the sensitivity of the test instrumentation. Pulse echo systems are most frequently used in NDE. Information is extracted from the signals through measurements of the signal velocity, attenuation, the acoustic emission when stress is applied, and calculation of the acoustoelastic coefficients. Fracture properties, tensile and shear strengths, the interlaminar shear strength, the cohesive strength, yield and impact strengths, the hardness, and the residual stress can be assayed by ultrasonic methods. Finally, attention is given to analytical treatment of the derived data, with mention given to transition matrix, integral equation, and eigenstrain approaches.
An ultrasonic guided wave scan system was used to nondestructively monitor damage over time and position in a C/enhanced SiC sample that was creep tested to failure at 1200 C in air at a stress of 69 MPa (10 ksi). The use of the guided wave scan system for mapping evolving oxidation profiles (via porosity gradients resulting from oxidation) along the sample length and predicting failure location was explored. The creep-rupture tests were interrupted for ultrasonic evaluation every two hours until failure at approx. 17.5 cumulative hours.
A measurement structure for determining the thickness of a specimen without mechanical contact but instead employing ultrasonic waves including an ultrasonic transducer and an ultrasonic delay line connected to the transducer by a retainer or collar. The specimen, whose thickness is to be measured, is positioned below the delay line. On the upper surface of the specimen a medium such as a drop of water is disposed which functions to couple the ultrasonic waves from the delay line to the specimen. A receiver device, which may be an ultrasonic thickness gauge, receives reflected ultrasonic waves reflected from the upper and lower surface of the specimen and determines the thickness of the specimen based on the time spacing of the reflected waves.
In this study, an ultrasonic guided wave scan system was used to characterize various microstructural and flaw conditions in two types of ceramic matrix composites, SiC/SiC and C/SiC. Rather than attempting to isolate specific lamb wave modes to use for characterization (as is desired for many types of guided wave inspection problems), the guided wave scan system utilizes the total (multi-mode) ultrasonic response in its inspection analysis. Several time and frequency-domain parameters are calculated from the ultrasonic guided wave signal at each scan location to form images. Microstructural and defect conditions examined include delamination, density variation, cracking, and pre/ post-infiltration. Results are compared with thermographic imaging methods. Although the guided wave technique is commonly used so scanning can be eliminated, applying the technique in the scanning mode allows a more precise characterization of defect conditions.