Search NASA⌕ Search

SEARCH · Search NASA

Results for “microbolometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Self-heated thermocouples for far-infrared detection

A novel self-heated Bi-Sb thermocouple for far-infrared detection has been developed. The detector is suitable for integration with monolithic antennas and imaging arrays. The device is fabricated in a single photolithography masking step using a photoresist-bridge technique. This bridge technique has also been used to make microbolometers with lower 1/f noise than those made by two conventional masking steps. The thermocouples have a noise equivalent power of 7 x 10 to the -10th W/sq rt of Hz and a 3-dB frequency response of 150 kHz.

Neikirk, D. P.↗

Far-infrared embedding impedance measurements

A technique which allows the measurement of detector embedding impedance has been developed. By using a bismuth microbolometer as a variable resistance load the impedance of one element in a bow-tie antenna array operating at 94 GHz was inferred. The technique is frequency insensitive, and could be used throughout the far-infrared.

Neikirk, D. P.↗

Fabrication of sensitive high Tc bolometers

The rapid change of resistance with temperature of high quality films of high T sub c superconductors can be used to make resistance thermometers with very low temperature noise. Measurements on c-axis yttrium barium copper oxide (YBCO) films have given a spectral intensity of temperature noise less than 4 times 10(exp -8) K/Hz(exp 1/2) at 10 Hz. Consequently, the opportunity exists to make useful bolometric infrared detectors that operate near 90 K which can be cooled with liquid nitrogen. The fabrication and measurement of two bolometer architectures are discussed. The first is a conventional bolometer which consists of a 3000 A thick YBCO film deposited in situ by laser ablation on top of a 500 A thick SrTiO3 thickness and diced into 1x1 mm(exp 2) bolometer chips. Gold black smoke was used as the radiation absorber. The voltage noise was less than the amplifier noise when the film was current biased. Optical measurements gave an NEP of 5 times 10(exp -11) W/Hz(exp 1/2) at 10 Hz. The second architecture is that of an antenna-coupled microbolometer which consists of a small (5x10 cubic microns) YBCO film deposited directly on a bulk substrate with a low thermal conductance (YSZ) and an impedance matched planar lithographed spiral or log-periodic antenna. This structure is produced by standard photolithographic techniques. Measurements gave an electrical NEP of 4.7 times 10(exp -12) W/Hz(exp 1/2) at 10 kHz. Measurements of the optical efficiency are in progress. The measured performance of both bolometers will be compared to other detectors operating at or above liquid nitrogen temperatures so as to identify potential applications.

Nahum, Michael↗

International Symposium on Space Terahertz Technology, 1st, University of Michigan, Ann Arbor, Mar. 5, 6, 1990, Proceedings

Problems, proposed solutions, and recent results related to the development of solid-state oscillators, detectors, mixers, diode multipliers, and antennas at THz frequencies are addressed. Individual topics considered include: submillimeter heterodyne remote sensing of upper atmospheric gases, planar dipole array antenna with an elliptical lens, twin slot antenna structures integrated with microbolometer detectors for 94-GHz imaging. Also discussed are: quantum-well and quantum-barrier diodes for generating submillimeter wave power, planar Schottky barrier mixer diodes for space applications at submillimeter wavelengths, GaAs Schottky barrier varactor diodes for submillimeter wavelength power generation, planar doped barrier devices for subharmonic mixers.

Ulaby, Fawwaz↗

Superconductivity applications for infrared and microwave devices; Proceedings of the Meeting, Orlando, FL, Apr. 19, 20, 1990

Various papers on superconductivity applications for IR and microwave devices are presented. The individual topics addressed include: pulsed laser deposition of Tl-Ca-Ba-Cu-O films, patterning of high-Tc superconducting thin films on Si substrates, IR spectra and the energy gap in thin film YBa2Cu3O(7-delta), high-temperature superconducting thin film microwave circuits, novel filter implementation utilizing HTS materials, high-temperature superconductor antenna investigations, high-Tc superconducting IR detectors, high-Tc superconducting IR detectors from Y-Ba-Cu-O thin films, Y-Ba-Cu0-O thin films as high-speed IR detectors, fabrication of a high-Tc superconducting bolometer, transition-edge microbolometer, photoresponse of YBa2Cu3O(7-delta) granular and epitaxial superconducting thin films, fast IR response of YBCO thin films, kinetic inductance effects in high-Tc microstrip circuits at microwave frequencies.

Bhasin, Kul B.↗

BIB mixers

We have determined that the multi-pin 'microprocessor style' packages in which current Blocked Impurity Band (BIB) devices are mounted will not meet our IF bandwidth spec of greater than 2 GHz for a practical mixer. Hence we have started to repackage the Ga:Ge BIB devices in new microwave compatible packages. The smaller size of the microwave package mount necessitates cutting the BIB array down to include only the 3 smallest detectors: 0.2, 0.4, and 0.6 mm sq. A FIR beam incident at f/1.5 can be focussed on the smallest element for wavelengths shorter than 100 microns. A more typical (easier) beam convergence of f/3 will require 0.4 mm elements at 100 microns and 0.6 mm elements at 170 microns wavelength. Since the device capacitance (parasitic loss) scales with detector size, there is a tradeoff of speed of response and optical convenience. Our existing optics produce only the slower convergence beam, so we need to redesign the optical layout and are looking at long focal length all-reflective microscope objectives. BIB detectors and the edge-coupled microbolometers have restricted IF bandwidths, an order of magnitude less than what is possible with the Schottky-diode mixers we currently use for astronomical observations. Consequently the frequencies of the FIR laser lines must be close to the astronomical line of interest to be an effective Local Oscillator (LO). We have therefore begun a coordinated effort to discover and measure new FIR laser transition lines in close frequency coincidence with important astrophysical lines. Most of this effort involves pumping isotopic variants of known good laser molecules with laser lines from isotopic variants of CO2. We have been most successful in detecting new FIR lines in deuterated ammonia. One line in particular is very close to the frequency of HD rotational line at 2675 GHz.

Source record↗

HgCdTe Photoconductive Mixers for 2-8 THz

Heterodyne spectroscopy has been taken to wavelengths as short as 63 micrometers with Schottky-diode mixers. Schottkys, however, are relatively insensitive compared to superconducting mixers such as the hot-electron microbolometer (HEB), which has an effective quantum efficiency of 3% at 120 micrometers (2.5 THz). Although HEB sensitivities are bound to improve, there will always be losses associated with antenna coupling of radiation into sub-micron size devices. Another approach to far infrared (FIR) mixer design is to use a photoconductive device which can be made much larger than a wavelength, and thus act as its own antenna. For example, HgCdTe photodiodes have been used as mixers in the lambda = 10 micrometers band for over 25 years, with sensitivities now only a factor of 2 from the quantum-noise-limit. HgCdTe can also be applied at FIR wavelengths, but surprisingly little work has been done to date. The exception is the pioneering work of Spears and Kostiuk and Spears, who developed HgCdTe photomixers for the 20-120 micrometer region. The spectral versatility of the HgCdTe alloy is well recognized for wavelengths as long as 8-20 micrometers. What is not so recognized, however, is that theoretically there is no long wavelength limit for appropriately composited HgCdTe. Although Spears successfully demonstrated a photoconductive response from HgCdTe at 120 micrometers, this initial effort was apparently never followed up, in part because of the difficulty of controlling the HgCdTe alloy composition with liquid-phase-epitaxy (LPE) techniques. With the availability of precise molecular-beam-epitaxy (MBE) since the early 1990's, it is now appropriate to reconsider HgCdTe for detector applications longward of lambda = 20 micrometers. We recently initiated an effort to fabricate detectors and mixers using II-VI materials for FIR wavelengths. Of particular interest are device structures called superlattices, which offer a number of advantages for high sensitivity direct detectors and very long wavelength heterodyne mixers.

Betz, A. L.↗

Combined Infrared Stereo and Laser Ranging Cloud Measurements from Shuttle Mission STS-85

Multi-angle remote sensing provides a wealth of information for earth and climate monitoring. And, as technology advances so do the options for developing instrumentation versatile enough to meet the demands associated with these types of measurements. In the current work, the multiangle measurement capability of the Infrared Spectral Imaging Radiometer is demonstrated. This instrument flew as part of mission STS-85 of the space shuttle Columbia in 1997 and was the first earth-observing radiometer to incorporate an uncooled microbolometer array detector as its image sensor. Specifically, a method for computing cloud-top height from the multi-spectral stereo measurements acquired during this flight has been developed and the results demonstrate that a vertical precision of 10.6 km was achieved. Further, the accuracy of these measurements is confirmed by comparison with coincident direct laser ranging measurements from the Shuttle Laser Altimeter. Mission STS-85 was the first space flight to combine laser ranging and thermal IR camera systems for cloud remote sensing.

Lancaster, Redgie S.↗

Superconducting Mixers for Far-Infrared Spectroscopy

The goal of this project was to fabricate and test planar arrays of superconducting mixers for the 2-6 THz band. The technology is intended for multi-beam receivers aboard Explorer-class missions and the SOFIA Airborne Observatory. The mixer technology is the superconducting transition-edge microbolometer, which is more commonly known as the Hot-Electron micro-Bolometer (HEB). As originally proposed, two superconducting technologies were to be developed: (1) low-Tc niobium HEBs which could approach quantum-noise-limited sensitivities but require cooling to 2- 4 K, and (2) high-Tc YBCO HEBs with sensitivities 10 times worse but with a relaxed cooling requirement of 30-60 K. The low-Tc devices would be best for astronomy applications on SOFIA, whereas the high-Tc devices would be more suitable for planetary missions using systems without stored cryogens. The work plan called for planar micro-fabrication and initial testing of HEB devices at the NIST Boulder clean-room facility. Subsequent assembly and RF testing of selected devices would be done at the CASA laboratory at U. Colorado. Approximately 1-year after work began on this project, Dr. Eyal Gerecht joined the NIST group, and assumed day-to-day responsibility for Nb-HEB development at NIST outside of micro-fabrication. The YBCO-HEB work was to be guided by Dr. Ron Ono, who was the NIST expert in YBCO technology. Unfortunately, recurrent health problems limited the time Ron could devote to the project in its first year. These problems became aggravated in early 2001, and sadly led to Ron's death in October, 2001. His loss was not only a blow to his friends and associates at NIST, but was mounted by the US superconductivity community at large. With his passing, work on high-Tc HEBs ceased at NIST. There was no one to replace him or his expertise. Our work subsequently shifted solely to Nb-HEB devices. In the sections which follow, our progress in the development of diffusion-cooled Nb-HEB mixers is detailed. To simplify the terminology, these devices will subsequently be called DHEB mixers to distinguish them from phonon-cooled devices (PHEBs).

Betz, A. L.↗

High Spatial Resolution Thermal Satellite Technologies

This document in the form of viewslides, reviews various low-cost alternatives to high spatial resolution thermal satellite technologies. There exists no follow-on to Landsat 7 or ASTER high spatial resolution thermal systems. This document reviews the results of the investigation in to the use of new technologies to create a low-cost useful alternative. Three suggested technologies are examined. 1. Conventional microbolometer pushbroom modes offers potential for low cost Landsat Data Continuity Mission (LDCM) thermal or ASTER capability with at least 60-120 ground sampling distance (GSD). 2. Backscanning could produce MultiSpectral Thermal Imager performance without cooled detectors. 3. Cooled detector could produce hyperspectral thermal class system or extremely high spatial resolution class instrument.

Ryan, Robert↗

Superconducting Digital Multiplexers for Sensor Arrays

Arrays of cryogenic microbolometers and other cryogenic detectors are being developed for infrared imaging. If the signal from each sensor is amplified, multiplexed, and digitized using superconducting electronics, then this data can be efficiently read out to ambient temperature with a minimum of noise and thermal load. HYPRES is developing an integrated system based on SQUID amplifiers, a high-resolution analog-to-digital converter (ADC) based on RSFQ (rapid single flux quantum) logic, and a clocked RSFQ multiplexer. The ADC and SQUIDs have already been demonstrated for other projects, so this paper will focus on new results of a digital multiplexer. Several test circuits have been fabricated using Nb Josephson technology and are about to be tested at T = 4.2 K, with a more complete prototype in preparation.

Kadin, Alan M.↗

Combined Infrared Stereo and Laser Ranging Cloud Measurements from Shuttle Mission STS-85

Multiangle remote sensing provides a wealth of information for earth and climate monitoring, such as the ability to measure the height of cloud tops through stereoscopic imaging. As technology advances so do the options for developing spacecraft instrumentation versatile enough to meet the demands associated with multiangle measurements. One such instrument is the infrared spectral imaging radiometer, which flew as part of mission STS-85 of the space shuttle in 1997 and was the first earth- observing radiometer to incorporate an uncooled microbolometer array detector as its image sensor. Specifically, a method for computing cloud-top height with a precision of +/- 620 m from the multispectral stereo measurements acquired during this flight has been developed, and the results are compared with coincident direct laser ranging measurements from the shuttle laser altimeter. Mission STS-85 was the first space flight to combine laser ranging and thermal IR camera systems for cloud remote sensing.

Lancaster, R. S.↗

Uncooled long-wave infrared hyperspectral imaging

A long-wave infrared hyperspectral sensor device employs a combination of an interferometer with an uncooled microbolometer array camera to produce hyperspectral images without the use of bulky, power-hungry motorized components, making it suitable for UAV vehicles, small mobile platforms, or in extraterrestrial environments. The sensor device can provide signal-to-noise ratios near 200 for ambient temperature scenes with 33 wavenumber resolution at a frame rate of 50 Hz, with higher results indicated by ongoing component improvements.

Lucey, Paul G.↗

NASA Tech Briefs, November 1995

The contents include: 1) Mission Accomplished; 2) Resource Report: Marshall Space Flight Center; 3) NASA 1995 Software of the Year Award; 4) Microbolometers Based on Epitaxial YBa2Cu3O(sub 7-x) Thin Films; 5) Garnet Random-Access Memory; 6) Fabrication of SNS Weak Links on SOS Substrates; 7) High-Voltage MOSFET Switching Circuit; 8) Asymmetric Switching for a PWM H-Bridge Power Circuit; 9) Better Ohmic Contacts for InP Semiconductor Devices; 10) Low-Bandgap Thermovoltaic Materials and Devices; 11) Digital Frequency-Differencing Circuit; 12) Imaging Magnetometer; 13) Computer-Assisted Monitoring of a Complex System; 14) Buffered Telemetry Demodulator; 15) Compact Multifunction Inspection Head; 16) Optical Detection of Fractures in Ceramic Diaphragms; 17) Eddy-Current Detection of Cracks in Reinforced Carbon/Carbon; 18) Apparent Thermal Conductivity of Multilayer Insulation; 19) Optimizing Misch-Metal Compositions in Metal Hydride Anodes; 20) Device for Sampling Surface Contamination; 21) Probabilistic Failure Assessment for Fatigue; 22) Probabilistic Fatigue and Flaw-Propagation Analysis; 23) Windows Program for Driving the TDU-850 Printer; 24) Subband/Transform MATLAB Functions for Processing Images; 25) Computing Equilibrium Chemical Compositions; 26) Program Processes Thermocouple Readings; 27) ICAN-Second-Generation Integrated Composite Analyzer; 28) Integrated Composite Analyzer with Damping Capabilities; 29) Computing Efficiency of Transfer of Microwave Power; 30) Program Calculates Power Demands of Electronic Designs; 31) Cost-Estimation Program; 32) Program Estimates Areas Required by Electronic Designs; 33) Program to Balance Mapped Turbopump Assemblies; 34) BiblioTech; 35) Controlling Mirror Tilt With a Bimorph Actuator; 36) Burst-Disk Device Simulates Effect of Pyrotechnic Device; 37) Bearing-Mounting Concept Accommodates Thermal Expansion; 38) Parallel-Plate Acoustic Absorbers for Hot Environments; 39) Adjustable-Length Strut Withstands Large Cyclic Loads; 40) Tool Indicates Contact Angles in Bearing Raceways; 41) Gravity Slides With Magnetic Braking; 42) High-Torque, Lightweight, Pneumatically Driven Wrench for Small Spaces; 43) Device for Testing Compatibility of an O-Ring; 44) Magnetic Heat Pump Containing Flow Diverters; 45) Variable-Tilt Helicopter Rotor Mast; 46) "Beach-Ball" Robotic Rovers; 47) Apparatus Would Measure Temperatures of Ball Bearings; 48) Flexible Borescope for Inspecting Ducts; 49) Texturing Copper To Reduce Secondary Emission of Electrons; 50) Automated Laser Cutting in Three Dimensions; 51) Algorithm Helps Monitor Engine Operation; 52) Flexible Revision of Data-Processing Communications; 53) Software for Managing the Use of Land; 54) Thermal Strap Increases Cryocooling Efficiency; 55) Reversible Nut With Engagement Indication; 56) Control Algorithms for Kinematically Redundant Manipulators; 57) Computed Hydrogen-Flow Splits in a Rocket Engine; 58) Pressure and Thermal Modeling of Rocket Launches; 59) Field of View of a Spacecraft Antenna: Analysis and Software; 60) Digital Controller for Laser-Beam-Steering Subsystem; 61) More About Beam-Steering Subsystem for Laser Communication; 62) Digital Controller for Laser-Beam-Steering Subsystem: Part 2; 63) Interface Circuit Board for Space-Shuttle Communications; 64) Automated Planning of Spacecraft Telecommunications; 65) Artifacts of Spectral Analysis of Instrument Readings; 66) Neural-Network Controller for Vibration Suppression; 67) Adaptive Finite-Element Computation in Fracture Mechanics; 68) Attitude Control for the Cassini Spacecraft; 69) Analytical Model for Fluid Dynamics in a Microgravity Environment; 70) Study of Rocket-Engine Joints Bonded by NVCU/NARloy-Z; 71) Improved Silicon Nitride for Advanced Heat Engines; 72) Parameters for Welding Aluminum/Lithium Alloys; 73) Lightweight Composite Intertank Structure; 74) Foil Patches Seal Small Vacuum Leaks; 75) Data Base on Cables and Connectors; 76) Effect of Clock Mode on Radiation Hardnessf an ADC; and 77) Fault-Tolerant Control for a Robotic Inspection System.

Source record↗

Can the Lateral Proximity Effect Be Used to Create the Superconducting Transition of a Micron-Sized TES?

Recent measurements of micron-sized Mo/Au bilayer Transition Edge Sensors (TESs) have demonstrated that the TES can behave like an S-S'-S weak link due to the lateral proximity effect from superconducting leads. In this regime the Tc is a function of bias current, and the effective Tc shifts from the bilayer Tc towards the lead Tc. We explore the idea that a micron-sized S-N-S weak link could provide a new method to engineer the TES Tc. This method would be particularly useful when small size requirements for a bilayer TES (such as for a hot-electron microbolometer) lead to undesirable shifts in the bilayer Te. We present measurements of a variety of micron-sized normal Au 'TES' devices with Nb leads. We find no evidence of a superconducting transition in the Au film of these devices, in dramatic contrast to the strong lateral proximity effect seen in micron-sized Mo/Au bilayer devices. The absence of a transition in these devices is also in disagreement with theoretical predictions for S-N-S weak links. We hypothesize that a finite contact resistance between the Nb and Au may be weakening the effect. We conclude that the use of the lateral proximity effect to create a superconducting transition will be difficult given current fabrication procedures.

Barrentine, E. M.↗

NASA Tech Briefs, January 2014

Topics include: Multi-Source Autonomous Response for Targeting and Monitoring of Volcanic Activity; Software Suite to Support In-Flight Characterization of Remote Sensing Systems; Visual Image Sensor Organ Replacement; Ultra-Wideband, Dual-Polarized, Beam-Steering P-Band Array Antenna; Centering a DDR Strobe in the Middle of a Data Packet; Using a Commercial Ethernet PHY Device in a Radiation Environment; Submerged AUV Charging Station; Habitat Demonstration Unit (HDU) Vertical Cylinder Habitat; Origami-Inspired Folding of Thick, Rigid Panels; A Novel Protocol for Decoating and Permeabilizing Bacterial Spores for Epifluorescent Microscopy; Method and Apparatus for Automated Isolation of Nucleic Acids from Small Cell Samples; Enabling Microliquid Chromatography by Microbead Packing of Microchannels; On-Command Force and Torque Impeding Devices (OC-FTID) Using ERF; Deployable Fresnel Rings; Transition-Edge Hot-Electron Microbolometers for Millimeter and Submillimeter Astrophysics; Spacecraft Trajectory Analysis and Mission Planning Simulation (STAMPS) Software; Cross Support Transfer Service (CSTS) Framework Library; Arbitrary Shape Deformation in CFD Design; Range Safety Flight Elevation Limit Calculation Software; Frequency-Modulated, Continuous-Wave Laser Ranging Using Photon-Counting Detectors; Calculation of Operations Efficiency Factors for Mars Surface Missions; GPU Lossless Hyperspectral Data Compression System; Robust, Optimal Subsonic Airfoil Shapes; Protograph-Based Raptor-Like Codes; Fuzzy Neuron: Method and Hardware Realization; Kalman Filter Input Processor for Boresight Calibration; Organizing Compression of Hyperspectral Imagery to Allow Efficient Parallel Decompression; and Temperature Dependences of Mechanisms Responsible for the Water-Vapor Continuum Absorption.

Source record↗

A Thermal Imaging Instrument with Uncooled Detectors

In this work, we performed an instrument concept study for sustainable thermal imaging over land with uncooled detectors. We evaluated two different uncooled detector technologies uncooled microbolometers and thermopiles. We have also evaluated materials for use in in a uncooled thermopile detector concept.

Thermal↗

Compact LWIR Polarimeter for Cirrus Ice Properties

A miniaturized long-wave InfraRed (LWIR) spectro-polarimeter is being developed as a prototype for the Compact Submm-Wave and LWIR Polarimeters (SWIRP) project. The polarimeter in development is a compact (20x20x40 cm) conical-scan instrument to measure the polarimetric radiation from ice cloud scattering at mm-submm (220 and 680 GHz) and IR (8.6, 11, and 12 m) bands. The LWIR polarimeter will provide a series of polarization measurements across the 8.5 - 12.5 micron band, measuring the full set of linear Stokes parameters (I, Q, U) as a function of wavelength. The spectro-polarimeter uses a combination of birefringent crystals, a Wollaston prism, a diraction grating, and an uncooled microbolometer array to measure both the degree and angle of linear polarization across the spectral bandwidth by modulating the polarization ux in wavelength with a high order retarder.

LWIR↗