A hybrid surrogate modeling framework for the Digital Twin of a Fluoride-salt-cooled High-temperature Reactor (FHR)

While nuclear energy is a non-greenhouse-gas emitting energy source, expensive operational costs due to the high-level of safety requirements decreases their competitiveness in the sustainable energy market. Advanced reactor concepts paired with Digital Twins aim to increase the commercialization gains of nuclear energy by reducing operational costs, increasing reactor reliability and enhancing power generation. To support Digital Twin tasks such as real-time autonomous control, proactive maintenance monitoring or optimizing power demand operations, a fast and accurate virtual representation of the Nuclear Power Plant (NPP) is required. The computational cost of high-fidelity, physics-based models are unsuitable for real-time analysis or scalability. Here, in this work, a hybrid surrogate modeling framework is developed fora Fluoride-salt-cooled High-temperature Reactor (FHR) that leverages physics-inspired models for key reactor components and uses data-driven methods for rapid system state space prediction. The Xenon reactivity feedback model is integrated to inform the surrogate model about the reactor core and the homologous pump theory model is the basis for representing pump degradation. Using a detailed, two dimensional thermal hydraulics model to generate data on the FHR, we train a network of Vectorized Autoregressive Moving-Average with eXogenous input (VARMAX) models to predict the remaining state values. The result is a surrogate model that provides a detailed reactor state representation of 41 system states and a pump degradation analysis. The framework is applied to Load Follows profiles, yielding high accuracy and a speedup that is more than 4000x faster compared to the higher- fidelity thermal hydraulics model, enabling real-time operational intelligence and applications in long horizon predictions. While the surrogate model framework is demonstrated for the particular case of FHR, the hybrid physical/data-driven modeling approach including the network of surrogates and the underlying modularity has the potential to be applied to other physical asset systems.

Digital Twins↗

Cost and Performance Baseline for Fossil Energy Plants, Volume 5: Natural Gas Electricity Generating Units for Flexible Operation

To address the data needs of energy system designers and to serve as a baseline for research and development, NETL has carried out a study to characterize the flexibility attributes - both performance and cost - of nine common commercial natural gas-fueled electricity generating units. The intermittent output of low-carbon, renewable power generation sources such as wind and solar create challenges to grid stability and reliability. Fossil-fueled power generation technologies are currently used to provide reliable, on-demand power during periods of reduced renewable output. Dispatchable generators must be able to accommodate increasing renewable generation as the nation pursues the Administration’s target of a decarbonized energy sector by 2035. As energy system experts seek to identify least-cost approaches to decarbonization, accurate cost and performance data characterizing dispatchable fossil generators that operate flexibly, at capacity factors that have been declining over time, and are needed to inform models for capacity expansion. Furthermore, these technologies continue to be a significant source of carbon dioxide emissions, providing the impetus for research and development, including the advancement and potential incorporation of carbon capture technologies. This study characterizes the cost and performance of select state-of-the-art natural gas-fueled power generation technologies: reciprocating internal combustion engines (RICE), simple cycle combustion turbines, and natural gas combined cycles (NGCC). An emphasis is placed on flexibility characteristics, such as part-load heat rate, ramp rates, start up times, and start up costs.

03 NATURAL GAS↗

Ammonia-Based Energy Storage Technology

The University of North Dakota Energy & Environmental Research Center (EERC), in partnership with the U.S. Department of Energy National Energy Technology Laboratory (NETL), Basin Electric Power Cooperative, Minnkota Power Cooperative, Otter Tail Power Company, and the North Dakota Industrial Commission (energy technology research and development sponsor), undertook a project to model, validate, and advance (from Technology Readiness Level [TRL] 2 to TRL 3) the ammonia-based energy storage technology (NH 3 -BEST) concept. The concept is designed to enable electricity-generating unit (EGU) accommodation of power demand fluctuations while steadily operating within an optimal-performance baseline power output range, ensuring maximum EGU operational efficiency and minimum degradation of materials, equipment, and performance because of load-cycling-driven stresses.

25 ENERGY STORAGE↗

Energy, power, and infrastructure demands from electrifying airport ground support equipment at United States airports

As the airline industry seeks to reduce costs and transition to clean energy, electric ground support equipment is emerging as a favorable option. The integration of electric ground support equipment into airport operations requires careful planning for vehicle deployment, charging infrastructure, and grid impacts. We develop a flexible, bottom-up modeling framework to assess energy and infrastructure needs across more than 300 U.S. airports. Our analysis estimates site-specific power and energy demand, equipment counts by type, charger requirements, and costs. Here we quantify the magnitude of new electrical loads created by the electrification of airport ground support equipment, finding that peak power demand at the largest airports can reach up to 20 megawatts, with annual electricity consumption approaching 51,000 megawatt-hours. We further show that behind-the-meter battery energy storage systems and solar photovoltaic systems can reduce peak load and lower total system costs by as much as 10 million dollars.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FREQUENCY REGULATION WITH CONNECTED LIGHTING SYSTEMS

The management of end-use energy resources, e.g., commercial buildings, has been investigated as a promising source of services for the electric power grid. Lighting consumes about 17% electricity of U.S. commercial buildings; however, it may contribute significantly to services that improve the reliability and resilience of the grid due to its rapid speed of response. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change their power demand more quickly than most other building electricity end uses. But the potential of CLS to provide grid services has not been considerably investigated. In this paper, we describe initial research to evaluate the potential of CLS for the grid service of frequency regulation. Frequency regulation is a reliability product that corrects in a matter of seconds for short-term changes in the balance between supply and demand in the balancing area that might affect the stability of the power system. Frequency regulation signals for a medium office building are generated from the normalized test signals for the PJM Interconnection Reg-A and Reg-D regulations services. Control of the CLS locally to follow the Reg-A or Reg-D signal is used to provide contributions to the corresponding frequency regulation service. The performance of CLS for frequency regulation is evaluated using the PJM 40-Minute Performance Score Template. The performance scores obtained for all CLS categories for both Reg-A and Reg-D signals far exceed the minimum score for the qualification, a very promising result for CLS to provide frequency regulation service.

Wang, Peng↗

Understanding Transient Combustion Phenomena in Low-NO x Gas Turbines

The goal of this work was to understand, quantify, and eventually predict combustion instability during operational transients in low-NO x gas turbine combustors. Transient operation is defined as a mode where one or more key operating parameters, including equivalence ratio, fuel composition, or fuel splitting between nozzles in a combustor, are varying in time. The timescale over which this variation occurs will be referred to as the transient timescale, the magnitude of the change in the transient parameter will be referred to as the transient amplitude, and the direction of the variation will be referred to as the transient direction. Transients occur regularly in power generation gas turbine operation. For example, load-following gas turbines vary load to meet power demands while accounting for variation in unsteady grid contributors like wind and solar power. Operators achieve this by varying equivalence ratio and fuel splitting inside the combustors to produce more or less power. Another example of transient operation is during fuel-switching operations, a particular issue for turbines operating with syngas fuels in a co-generation facility. In this case, the composition of the fuel stream may vary in time either as a result of fluctuations in the pipeline, or in the case of a co-generation plant, variations in feedstock or gasification processes. This fluctuation in fuel composition can have significant implications for combustion processes, particularly with high-hydrogen fuels. A small number of studies have investigated transient behavior in gas turbine combustors, particularly in the context of flame blow-off; here, investigators have typically focused on issues of transient amplitude, though without the depth and physics-based experimental design that is proposed in this program. To our knowledge, there have been no studies that have quantified the impact of the transient timescale on combustion. The work helped us understand the impact of several types of transients on combustion stability. Both static and dynamic combustion stability will be considered. The transients will be quantified using their amplitude, direction, and timescale, and we will consider transients in equivalence ratio, fuel composition, and fuel splitting. There were two main objectives of this work: 1. Provide a fundamental understanding of combustion stability during transient operation using data obtained from a number of high-speed diagnostic techniques on experimental configurations that capture important gas turbine combustor features and operating conditions. This goal was met in conjunction with our industrial partner, GE Global Research, with whom we worked closely throughout the program. 2. Develop a stability prediction framework that will allow for the prediction, and possible control, of instabilities as a function of the transient amplitude, direction, and timescale. This input/output model should be physics-based and allow for screening of operating conditions and prediction of unstable behavior at the end of a transient by monitoring combustor health and precursor signals during operation.

03 NATURAL GAS↗

Plug-in Electric Vehicle Charging Response Characterization for Grid Integration: Implications for Smart Charge Management

The rapid expansion of plug-in electric vehicles (PEVs) has created a unique challenge for electrical grids due to their significant power demand. At the same time, PEVs also create a unique opportunity to ease their own burden on the power grid, as they create a growing fleet of distributed energy resources capable of providing grid services such as demand response, frequency regulation, and renewable balancing. For aggregators and grid operators to effectively integrate PEVs into grid management, it is essential to first understand and characterize how they would respond in such situations. This study examines 25 models of PEVs across 25 makes, spanning model years from 2013 to 2025, to characterize their responses to the basic controls used in vehicle-grid integration (VGI): stopping, starting, and modulating the charge rate. Each vehicle was tested in a controlled laboratory setting to evaluate its performance in response to varying the maximum allowable current via the SAE J1772 control pilot signal, as well as its response to wake-up commands outlined in SAE J1772. Results show measurable differences across vehicle makes in the accuracy, latency, and precision with which PEVs respond to changes in ampacity, as well as varying sleep and wake-up behavior. The test results show that all vehicles respond to changes in ampacity, though with varying accuracy, precision, latency, and resolution. Wake-up behavior also differs across makes and models. These findings indicate that effective grid integration strategies must account for these differences. The results provide a foundation for understanding current vehicle behavior and advancing smart-charging methods while also highlighting the need for further testing, broader standardization, and manufacturer collaboration to ensure the successful integration of PEVs into the electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Dispatch With Secondary Frequency Regulation: A Pathway to Consider Intra-Interval Fluctuations

Real-time dispatch balances the power demand with minimized operating costs. For the current dispatch model, the demand is assumed to be constant within a time interval, while the intra-interval power balance is left to frequency regulation. Based on practical experience and simulations, this behavior may lead to insufficient frequency regulation and uneconomic regulation costs considering the increase in intra-interval fluctuations caused by renewables. Here, a real-time dispatch method with secondary frequency regulation behaviors is proposed. Without changing the interval of the real-time dispatch command, the system regulation mileage and intra-interval generation adjustment are explicitly formulated in a mixed-integer optimization model. To reduce the computational burden, an efficient two-stage calculation method is proposed. With practical utility data, this article finds that the proposed method can effectively improve the system frequency performance with the subminute net load forecasting curve obtained by an off-the-shelf forecasting approach. Time-domain simulations in IEEE and practical utility systems validate the effectiveness of the proposed method in terms of the frequency performance and total operating costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of Control Methods and Digital Twins for Advanced Nuclear Reactors

Advanced nuclear reactors offer a new set of features to energy generation, due to their ability to adapt to variable energy demand, operate autonomously, be deployed in rural locations and monitored remotely, afford compact size and lower power ratings, and rely on novel technologies to achieve safer operations. Thus, a requirement for the success of these reactors is the use of intelligent forms of control to track changing power demands, make autonomous decisions, and reduce the need for human involvement. Regulatory requirements pertaining to control of nuclear reactors could be met via historical means of control; however, these are not expected to enable the level of highly autonomous operations desired in advanced nuclear reactors. Historical control methods rely on both logical and high-performance (HP) control. These two types of control are usually used separately, with a human element being introduced whenever decisions are cascaded from one science to another. AI/ML control, on the other hand, can replace the human element in the current U.S. fleet of nuclear power plants (NPPs) by acting as a supervisory optimizer that understands the plant internal/external variables in order to make control decisions, and can easily handle non-linear and multi-input/multi out (MIMO) decisions—another requirement for advanced nuclear reactors that could be difficult to handle via logical and HP control. Because of the harsh operating environments produced in advanced reactors, resulting in the frequent failure of sensors and other types of equipment, and considering the lack of operating history for advanced nuclear reactors, control of advanced nuclear reactors would necessitate relying on a model that can track and adapt to the actual process (i.e., a digital twin). This digital twin can make approximations when knowledge and data are unavailable and would evolve as more knowledge is gained. The reactor control must also be risk-informed to account for the high-consequence nature of advanced reactors. This report introduces a high-level (i.e., not method- or process-specific) integration of the three different control and digital twinning methods able to meet the requirements for advanced nuclear reactors. These methods could be applied during both the operational and design stages of these reactors. The aim is to demonstrate how each method interfaces with and highlights enabling solutions necessitated by the unique features of advanced nuclear reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy Efficient, Cost-Effective Power and Co-Generation Technologies: Techno-Environmental Analysis

Development of energy solutions for addressing grid resiliency and energy efficiency while lowering greenhouse gas emissions is critical in today’s energy scenario. Chemical energy provides on demand power. Cogeneration technologies offer numerous benefits in meeting the growing energy demand while lowering the impact on environment. Utilization of waste heat from prime movers in conjunction with energy efficient heat pumps and renewable photovoltaics is an attractive approach. Efficient utilization of available resources to support current and future building energy needs targeting grid resiliency, energy and environmental security via co-generation approaches is the focus of this study. A detailed techno-environmental analysis of hybrid system configurations consisting of conventional and emerging technologies utilizing natural gas, electric grid, and renewable power resources along with heat recovery systems and heat pump technologies are analyzed and presented. The key objective is to present integrated system configurations and thermodynamic analysis of various co-generation systems suitable for providing building energy. Design solutions targeting low carbon footprint and high energy efficiency are presented.

Cheekatamarla, Praveen↗

Economic viability of using thermal energy storage for flexible carbon capture on natural gas power plants

Fossil fuel-based power plants generate 80% of the electricity in the United States and provide a reliable generation source for both base and peak power demands. These plants are expected to adapt to changes in environmental policies that will require carbon management with carbon capture and storage (CCS) representing a possible solution. Current solvent-based CCS has a detrimental impact on a power plant's performance due to large heat loads required for carbon capture solvent regeneration. This parasitic load restricts the power plant's output and operation flexibility. Therefore, this study evaluates the feasibility of using thermal storage technologies for natural gas combined cycle (NGCC) power plants coupled with CCS to minimize the impact of solvent regeneration and enable the plant to operate at peak power output. Thermal storage can minimize the impact of CCS on the power plant by providing the heat load required for solvent regeneration during times of peak demand which will allow the plant to operate unrestricted and at full power. In total, fifteen unique thermal storage configurations were evaluated from three thermal storage categories: Brayton cycle heat pump, vapor compression heat pump, and heat recovery steam generator steam extraction for storage. The viability of these systems was determined by evaluating each configuration on thousands of real-world Locational Marginal Pricing (LMP) profiles from the New York Independent System Operator and California Independent System Operator electricity markets using a techno-economic analysis. Afterwards, results were compared to the performance of a base power plant (NGCC with CCS and no thermal storage) to determine the impact of thermal storage on power plant economics. Overall, six of the thermal storage configurations performed better than base CCS enabled power plant on between 11.5% and 38.7% of the LMP signals evaluated. The best performing configuration was a vapor compression heat pump that used flue gas as the working fluid and had both hot and cold thermal storage units. This configuration performed better than the base CCS power plant on 38.7% of the LMP profiles. The results of this study show thermal storage can mitigate the economic impact of carbon capture solvent regeneration on NGCC power plants. Discussion focuses on the impact of electricity pricing on the optimal thermal storage system, the advantages and disadvantages of the systems evaluated, and identifies limitations with the study.

25 ENERGY STORAGE↗

Spatially Resolved Domicile Charging Demands for Light-, Medium-, and Heavy-Duty Electric Vehicles in Virginia

The use of plug-in electric vehicles (PEVs) and resulting grid impacts are likely to grow rapidly, and evaluation of optimal smart charge management and grid integration strategies is warranted now. Evaluating distribution grid impacts requires fine-grained models of PEV operations to estimate charging loads across diverse vehicles at high spatial resolution. We propose such a model and consider a high-electrification scenario in Richmond and Newport News, Virginia. Our framework considers four categories of vehicle that are amenable to early aggressive electrification: light-duty passenger vehicles (LDV), trucks and vans with a focus on delivery or other local operations, school buses, and transit buses. These vehicles have a relatively consistent domicile, reducing the need for public charging infrastructure rollout to electrify. We apply a recent LDV model and propose new models for each vocation of medium- and heavy-duty vehicle, leveraging telematics data. We demonstrate our framework in Virginia and find energy demands in the region may total 15 GWh day, with most consumed by LDV. However, considering power demand at high spatial resolution reveals a different trend: LDVs have relatively small peak loads at specific sites (peak site demand around 800 kW) compared to average and high demand medium- and heavy-duty vehicle charging sites (peak site demand around 6,000 kW at a transit bus depot, 1,500 kW at a local freight hub, and 1,000 kW at a school). Our framework yields insights on the relative impacts of each vocation and enables future work to tailor grid integration strategies to each vehicle category.

33 ADVANCED PROPULSION SYSTEMS↗

A Framework to Analyze the Requirements of a Multiport Megawatt-Level Charging Station for Heavy-Duty Electric Vehicles

Widespread adoption of heavy-duty (HD) electric vehicles (EVs) will soon necessitate the use of megawatt (MW)-scale charging stations to charge high-capacity HD EV battery packs. Such a station design needs to anticipate possible station traffic, average and peak power demand, and charging/wait time targets to improve throughput and maximize revenue-generating operations. High-power direct current charging is an attractive candidate for MW-scale charging stations at the time of this study, but there are no precedents for such a station design for HD vehicles. We present a modeling and data analysis framework to elucidate the dependencies of a MW-scale station operation on vehicle traffic data and station design parameters and how that impacts vehicle electrification. This framework integrates an agent-based charging station model with vehicle schedules obtained through real-world vehicle telemetry data analysis to explore the station design and operation space. A case study applies this framework to a Class 8 vehicle telemetry dataset and uses Monte Carlo simulations to explore various design considerations for MW-scale charging stations and EV battery technologies. The results show a direct correlation between optimal charging station placement and major traffic corridors such as cities with ports, e.g., Los Angeles and Oakland. Corresponding parametric sweeps reveal that while good quality of service can be achieved with a mix of 1.2-megawatt and 100-kilowatt chargers, the resultant fast charging time of 35–40 min will need higher charging power to reach parity with refueling times.

33 ADVANCED PROPULSION SYSTEMS↗

Conceptual Design Study of a Thermal Energy Storage System Using Granular Solids for Coal-fired Boilers

<span style="font-size: 12pt;">Presentation for the 2020 International Pittsburgh Coal Conference held virtually from September 8-11, 2020.</span><span style="font-size: 12pt;">Abstract: As electricity from various renewable energy sources is increasingly supplied to the power grid, the grid’s stability will be challenged. Proposed grid-stability solutions will need to address variability of sources, such as solar and wind energy, in order to alleviate problems such as overgeneration and ramping. In regions where increases in solar energy are prominent, such as California, the net power demand curve often referred to as “the Duck Curve,” has caused problems for energy dispatchers, due to over-generation and fast ramping demands. In this project, we investigated a conceptual design for a Thermal Energy Storage System (TESS) integrated into a coal-fired power plant to support grid-scale storage. Implementing a TESS into power plants can allow for an increase in renewable sources, increase grid resilience, and allow conventional coal-fired plants to operate more efficiently. For this project, a TESS using granular solids as the energy-storage media is integrated into a conventional coal-fired power plant. The purpose of the TESS is to store energy from the flue gas during low demand periods and transfer the energy to steam during peak demand periods. The storage allows the stabilization of combustion and related boiler components at low loads and provides the opportunity to avoid some shutdowns. This study uses thermodynamic properties of several candidate thermal storage materials to estimate the size of storage system required for several operating scenarios. </span>

Huckaby, E. David↗

Biochemical Conversion of Herbaceous Biomass to Renewable Diesel: Net Greenhouse Gas and Air Pollutant Trade-offs

This study examines greenhouse gas (GHG) and criteria air pollutant (CAP) emissions trade-offs for renewable diesel across 12 scenarios, involving different biochemical conversion designs, biorefinery scales, and feedstocks. A conventional design uses lignin for on-site heat and power, which exports excess power to the grid. An alternative design exports lignin pellets, offsetting other pellet production methods but requiring grid electricity to meet biorefinery power demands. Net emissions were quantified in Iowa and Georgia, selected considering feedstock availability, coproduct displacement, and regional power grids, assuming grid-exported power avoids coal or low-carbon electricity. Results for the conventional design remained consistent across the electricity displacement scenarios. When comparing lignin utilization strategies, pelletizing lignin reduces sulfur dioxide, carbon monoxide, nitrogen oxides, and volatile organic compounds (net emissions –0.66 mg MJ –1 , 25 mg MJ –1 , 25 mg MJ –1 , 7.8 mg MJ –1 , respectively). However, lignin pelletization increases net particulate matter (fine and coarse) and ammonia (net emissions of 4.7 mg MJ –1 , 13 mg MJ –1 , and 0.26 mg MJ –1 , respectively), alongside indirect GHG emissions due to grid electricity dependence. Additionally, processing 2000 tonnes corn stover daily minimizes emissions for both designs. Only lignin pelletization with renewable electricity and additional particulate matter and ammonia controls reduces all CAP and GHG emissions simultaneously.

09 BIOMASS FUELS↗

Integrating Control Methods and Digital Twins for Advanced Nuclear Reactors

Advanced nuclear reactors offer new capabilities such as the ability to adapt to variable energy demand, operate autonomously with remote supervision, be deployable in rural locations, be compact in size, afford lower power ratings, and rely on novel techniques for increased operational safety. However, realizing these capabilities requires intelligent control systems that can track changing power demands and make autonomous decisions based on these demands. The unique aspects of advanced reactors (e.g., strict regulatory requirements, harsh operating environments, high consequences, highly coupled dynamics, evolving knowledge, and limited operating histories) directly impact the design and deployment of control systems for these reactors. The present work identifies and evaluates these aspects so as to develop a set of control system requirements to guide future research and development. To meet these requirements, a layered control system approach is proposed that integrates digital twins with different control paradigms. This work aims to demonstrate how different methods interface with enabling solutions, and to identify any gaps that need to be researched.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vitamin-Mediated Glucose Flow Cell for Sustainable Power Generation

Glucose as biofuel asserts unique advantages, including low-temperature electricity generation, easy accessibility, low storage cost, and flexible application for on-demand power generation. Riboflavin, also known as Vitamin B 2 , is a critical component in biological systems and is involved in many metabolic reactions as enzyme cofactors. Inspired by these metabolic reactions, we demonstrate a flow cell for electrochemical glucose oxidation reaction (GOR), using riboflavin as an environmentally friendly mediator to replace traditional noble metal catalysts. When paired with O 2 under alkaline conditions, the glucose flow cell achieves a peak power density of 13 mW/cm 2 , 20 times higher than the previous report in alkaline conditions. The demonstrated vitamin-mediated engineered biofuel flow cell delivered high peak power density at room temperature/ambient pressure while maintaining low cost and environmental friendliness, eliminating the need for a noble metal catalyst.

electrolytes↗

Recent advances and challenges in optimization models for expansion planning of power systems and reliability optimization

Optimization models for expansion planning of power systems aim to determine capacities, investment timing, and location of power systems to satisfy the power demands while minimizing the total cost. The models have become complex in recent years to reflect both regulations on conventional energy sources and the increasing penetration of renewable energy sources (RES). This paper reviews the basic concepts and optimization models for expansion planning of power systems. We first explain the definition and features of generation expansion planning (GEP), transmission expansion planning (TEP), and generation and transmission expansion planning (GTEP). To address the computational challenges of large-scale expansion planning problems, we review several simplifications including temporal and spatial aggregation, and decomposition methods. This paper also addresses power system reliability defined as the probability of satisfying the load demand while withstanding failures of components. Finally, the goal of this paper is to provide a research overview, discuss trends in expansion planning of power systems, and suggest directions for future research.