Search NASASearch

SEARCH · Search NASA

Results for “Carbon Storage Capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

608 records · Page 32

Used Nuclear Fuel Management Using the Next Generation System Analysis Model

The U.S. Department of Energy (DOE) is leading the National effort to manage the back end of the nuclear fuel cycle, encompassing the safe transportation, storage/staging, and/or eventual disposal of used nuclear fuel (UNF) and high-level radioactive waste. The Next Generation System Analysis Model (NGSAM) is DOE’s discrete-event, agent-based simulation tool designed to model the full life cycle of UNF from reactor discharge to final disposal. NGSAM supports the DOE Office of Spent Fuel and High-Level Waste Disposition by enabling a detailed, scenario-based analysis of logistics, infrastructure, and shipping strategies. NGSAM replaces legacy models with a modern, flexible platform built on Repast Simphony and enhanced by the Process Analysis Tool. NGSAM simulates the movement and interaction of individual fuel assemblies with system components such as canisters, casks, railcars, and facilities. The model integrates with the Java Transportation Operations Model to plan and execute transportation scenarios, supporting both constrained and unconstrained resource allocation. Key features include customizable allocation and acceptance algorithms, detailed facility-level operations, and a Quick Edit tool for rapid scenario adjustments. NGSAM supports multimodal transportation modeling (e.g. rail, road, barge) and provides comprehensive cost, schedule, and infrastructure data. NGSAM utilizes data from sources such as DOE’s STANDARDS UNF database and DOE’s Stakeholder Tool for Assessing Radioactive Transportation, while also allowing user-defined inputs for scenario customization. NGSAM enables stakeholders to evaluate complex UNF management strategies, assess system performance under varying assumptions, and inform decision making for future infrastructure investments. Its modular architecture and integration with other Integrated Waste Management System tools make it a critical asset for planning the safe and efficient disposition of the Nation’s growing UNF inventory.

Craig, Brian [Argonne National Laboratory (ANL)]

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)

Stoichiometric effects on grain growth in zirconium carbide coatings for high-temperature nuclear fuel

Interest in coated particle fuel for space nuclear propulsion (SNP) has expanded in recent years due to successful demonstrations of the resiliency of the coatings to extreme environments. For SNP applications, the coating layer for the particle design needs to be able to withstand exposure to high temperature hydrogen during operating conditions. ZrC has been proposed as a protective layer, however, it is important to understand the high temperature behavior to ensure adequate protection to this fuel. In this study, surrogate ZrC coated particles were heat treated at 1900 °C up to 300 min, to examine how the microstructure evolves when exposed to high temperature. Scanning electron microscopy and electron backscatter diffraction (EBSD) were conducted to determine grain size and grain boundary character and orientation to determine the degree of change in the ZrC layer post heat treatment. Raman spectroscopy provided insight to understand how the as-fabricated stoichiometry of each sample contributed to the differences in grain growth behavior. Despite the as-fabricated samples showing a similar initial grain size and grain boundary character, the samples with a higher amount of excess carbon exhibited smaller grain areas and slower growth rates when exposed to 1900 °C. In conclusion, this investigation details the as-fabricated microstructure of the ZrC layer, specifically grain size, evolved under high temperature as this can impact the performance of the fuel under operating conditions.

EBSD

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

ECLSS

Improving Ionic Conformality Across Polymer Electrolyte|Electrode Interfaces

Maintaining uniform ionic transport at electrode|electrolyte interfaces, i.e., ionic conformality, remains challenging in polymer electrolyte (PE)-based solid-state batteries. Morphological conformality does not necessarily imply ionic conformality. In PEs, which typically consist of a mechanically supporting component and distinct ionically conductive components, the rearrangement or depletion of mobile ion-conductive domains at interfaces can disrupt ionic transport pathways. Such localized ionic depletion contributes to interfacial instability and capacity degradation in high-voltage lithium-metal batteries. Herein, an electrolyte design approach aimed at minimizing interfacial heterogeneities is demonstrated through compositional adjustments, characterized by spatially resolved structural and chemical X-ray techniques and NMR diffusometry to elucidate ion transport dynamics. This approach improves ionic conformality at electrode interfaces, enhancing cycling stability in Li||LiNi 0.8 Co 0.1 Mn 0.1 O 2 (NMC811) coin and pouch cells cycled at high voltages. These results contribute to understanding interfacial behaviors in multiphase PEs and inform strategies for improving stability across solid-state battery interfaces.

36 MATERIALS SCIENCE

Novel PtNi single-atom–nanocluster (SA–NC) ensembles promote Tafel kinetics and ampere-class AEM hydrogen evolution

The development of efficient, durable, and low-PGM electrocatalysts for the hydrogen evolution reaction (HER) in alkaline media is critical for next-generation electrolysis technologies. We report a facile two-step synthesis of highly dispersed PtNi and PtNi-nitride nanoclusters (NCs) (~2.3 nm) with ultralow Pt content (0.5 at.%) anchored on N-doped Vulcan carbon. Structural and compositional characterization via XAS, XPS, HAADF-STEM, HRTEM, and EDS mapping established key structure–activity relationships across varying Pt/Ni ratios and pyrolysis temperatures. The Pt0.5Ni0.5/C-750 catalyst, an ensemble of PtNi M-N-C type single-atom (SA) moieties with neighboring PtNi nanoclusters (NC), exhibited superior HER performance in alkaline media, achieving overpotentials of 30, 115, and 210 mV at 10, 100, and 500 mA cm−2, respectively. Despite at a lower Pt content, this novel SA–NC ensemble outperformed commercial Pt/C by ~36%. A standardized literature comparison with contemporary Pt- and Ru-doped analogues reveals the as-prepared Pt0.5Ni0.5/C-750 to sit at the apex of Tafel-limited kinetics and low overpotential at 100 mA cm−2. Tafel-limited Tafel slopes in both alkaline and acidic regimes confirm favorable proton recombination kinetics. Mass activities at 200 mV reached 13.8 and 18.84 A mgPt−1 in alkaline and acidic media, respectively. However, excessive nitridation (e.g., at 650 °C) adversely altered Pt electronic structure and HER kinetics. While Ni enhanced alkaline HER, acidic HER favored Ni-free analogues. Pt0.5Ni0.5/C-750 also demonstrated robust temperature responsiveness and 300-h operational stability at high current densities (0.5–1.0 A cm−2) in MEA tests. This work presents a scalable strategy for designing thermally responsive, durable, and compositionally tunable NC catalysts with neighboring SA moieties for alkaline electrolysis.

AEMWE

Manipulating Na/TM Ratio‐Driven Structural Heterogeneity of O3‐NaNi 1/3 Fe 1/3 Mn 1/3 O 2 Cathode for High‐Voltage Sodium‐Ion Batteries

The stability of O3-type NaNi 1/3 Fe 1/3 Mn 1/3 O 2 under high-voltage cycling is dictated by how synthesis encodes lattice strain and redox heterogeneity. Here, in this study, the role of Na:TM stoichiometry is systematically resolved by tuning the NaOH:precursor ratio during solid-state synthesis. The stoichiometric condition (Na:TM = 1.00) yields minimized microstrain, enabling uniform O3–P3 phase evolution and homogeneous multi-metal redox with preserved octahedral symmetry. In contrast, Na-excess compositions inherit disordered intermediates and heterogeneous distortion fields that trigger abrupt multiphase transitions and promote localized charge redistribution. In situ XRD captures the divergence in phase-transition pathways, TXM resolves particle-level redox heterogeneity, and XANES corroborates a stronger and more reversible Fe redox contribution at stoichiometry, shifting to diminished Fe participation and spatially inhomogeneous redox at higher Na content. These results establish Na:TM stoichiometry as a critical synthesis parameter controlling both structural coherence and redox stability. Electrochemically, the stoichiometric composition exhibits smooth voltage profiles with minimal polarization growth and retains nearly 80% of its initial capacity after 100 cycles even at an extended 4.2 V cutoff, whereas Na-excess compositions show significantly reduced initial coulombic efficiency and rapid voltage fade. Precise stoichiometric tuning provides a scalable route to defect-suppressed O3 frameworks, enabling structurally resilient, high-voltage sodium-layered cathodes.

36 MATERIALS SCIENCE

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam

Electrically Accelerated Mechanochemical Film Formation by a Phosphonium Phosphate Ionic Liquid: An In Situ Chemical Kinetics Investigation

Powertrains in electric vehicles are exposed to stray currents that accelerate wear and cause failure of mechanical components. These durability issues are further aggravated when using low-viscosity lubricants, which are desired for energy efficiency but create harsher contact conditions at sliding interfaces. This study investigates a phosphonium phosphate ionic liquid as a performance-enhancing additive in a low-viscosity base oil for lubricating electrified sliding interfaces. Ionic liquids can adsorb and react on contact interfaces via stress-assisted chemical reactions, generating nanometric tribofilms that provide protection against wear. However, the effect of electric fields on the mechanochemistry of ionic liquids is poorly understood, hindering their adoption in lubricants for electrified powertrains. This article reports an in situ optical interferometry study of ionic liquid derived tribofilm growth kinetics at stressed sliding/rolling interfaces under direct currents. The application of electric currents accelerated tribofilm formation up to a critical current density (∼1.4 A/mm 2 ), beyond which pitting-induced wear dominated. The tribofilms were composed of iron phosphates, iron oxides, and carbon species, with iron oxides becoming predominant under applied currents. These tribofilms prevented the scuffing failure of steel surfaces under electrified conditions. Based on the results, a kinetic model is proposed that integrates electric current effect into the classical stress-assisted thermal activation framework to allow prediction of tribofilm growth at electrified sliding contacts. This framework provides crucial guidance for designing next-generation lubricants for electrified transportation and power generation systems.

additives

Direct observation of diamond formation in a shock-compressed high explosive

Understanding the formation timescale and structure of carbonaceous reaction products is critical for modeling the high-pressure equation-of-state of organic materials. We use the National Ignition Facility to shock-compress polycrystalline TATB (C 6 H 6 N 6 O 6 ) samples to ~70–130 GPa and ~4000–5500 K, employing in situ nanosecond X-ray diffraction to probe reaction products and velocimetry to measure transmitted compression wave profiles. Our diffraction data is consistent with the formation of diamond over timescales less than ~60 ns. This represents carbon condensation from a molecular explosive on timescales three times faster than previously reported and the earliest observation of diamond produced from reacting TATB. Reactive flow simulations with explicit chemistry reproduce the observed temporal structure within wave profiles to inform the distribution of P-T states. These findings provide direct evidence of ultrafast diamond formation in a reactive system at extreme conditions and provide new constraints for models of shock and detonation chemistry.

Clarke, Samantha M. [Lawrence Livermore National L

Scalable multiplexed machine learning gas sensor chips for food classification

Multiplexed gas sensor arrays combined with machine learning have unlocked previously inaccessible applications for scent-based sensing. Current platforms are limited by overlapping sensing materials with similar compositions, leading to highly correlated responses, or multistep deposition processes that hinder scalability. In this work, we developed a 16-element monolithic chip with fully distinct sensing layers, enabling a truly heterogeneous array. The system consists of highly sensitive carbon nanotube field effect transistors that are functionalized through a single-step microdispensing method compatible with automated pipetting systems. The resulting chip produces characteristic signal patterns in response to object-specific scent profiles and, when combined with machine learning algorithms, can perform automated object identification. We demonstrate the classification of 16 different objects, including food spoilage and nut allergens, with a 92.6% overall prediction accuracy.

Bassil, Carla [University of California, Berkeley,

BEAST: Expanding Sustainable Data Infrastructure for High-Enthalpy Facilities

Reproducible, data-driven thermal protection system (TPS) research requires that experimental records from high-enthalpy testing be consistently structured, traceable, and accessible across campaigns and institutions. In practice, however, arcjet and plasma facilities data remain largely fragmented: raw diagnostics are stored in ad hoc formats, material sample histories are disconnected from test conditions, and metadata standards are absent, precluding systematic cross-campaign analysis and long-term reuse. BEAST (Backend for Experiment Analysis, Storage, and Traceability) is an open-source, web-based platform that addresses these limitations by providing a unified, queryable infrastructure for high-enthalpy ground-test data [1]. First presented at the 15th Ablation Workshop [2], BEAST has since undergone significant development. The platform ingests and structures multi-channel time-series diagnostics, facility configurations, and material property records within a common provenance model, ensuring end-to-end traceability from raw sensor acquisition to reduced experimental quantities. A versioned material library links specimen identity and processing history to the specific runs in which each sample was tested. An integrated modeling workbench enables training and evaluation of regression models directly on archived experimental data, supporting condition interpolation and the construction of empirical material response databases. Beyond its original deployment at NASA Ames Research Center, BEAST has been designed to be facility-agnostic, with ongoing efforts to extend its adoption to other facilities. Its modular architecture accommodates heterogeneous diagnostic setups and facility types, and its future open-source distribution allows institutions to build on a common data standard rather than maintaining isolated, bespoke solutions. BEAST is further integrated within a broader ecosystem of companion tools: arcjetCV [3] extracts recession rates and shock standoff distances from high-speed video using computer vision, and miniSTARscan [4] provides sub-minute, portable photogrammetric surface reconstruction of test articles before and after exposure. All tools share a common data schema, enabling seamless ingestion of surface geometry, imagery, and time-series data into a single, coherent experimental record.

Database

BEAST: Expanding Sustainable Data Infrastructure for High-Enthalpy Facilities

Reproducible, data-driven thermal protection system (TPS) research requires that experimental records from high-enthalpy testing be consistently structured, traceable, and accessible across campaigns and institutions. In practice, however, arcjet and plasma facilities data remain largely fragmented: raw diagnostics are stored in ad hoc formats, material sample histories are disconnected from test conditions, and metadata standards are absent, precluding systematic cross-campaign analysis and long-term reuse. BEAST (Backend for Experiment Analysis, Storage, and Traceability) is an open-source, web-based platform that addresses these limitations by providing a unified, queryable infrastructure for high-enthalpy ground-test data [1]. First presented at the 15th Ablation Workshop [2], BEAST has since undergone significant development. The platform ingests and structures multi-channel time-series diagnostics, facility configurations, and material property records within a common provenance model, ensuring end-to-end traceability from raw sensor acquisition to reduced experimental quantities. A versioned material library links specimen identity and processing history to the specific runs in which each sample was tested. An integrated modeling workbench enables training and evaluation of regression models directly on archived experimental data, supporting condition interpolation and the construction of empirical material response databases. Beyond its original deployment at NASA Ames Research Center, BEAST has been designed to be facility-agnostic, with ongoing efforts to extend its adoption to other facilities. Its modular architecture accommodates heterogeneous diagnostic setups and facility types, and its future open-source distribution allows institutions to build on a common data standard rather than maintaining isolated, bespoke solutions. BEAST is further integrated within a broader ecosystem of companion tools: arcjetCV [3] extracts recession rates and shock standoff distances from high-speed video using computer vision, and miniSTARscan [4] provides sub-minute, portable photogrammetric surface reconstruction of test articles before and after exposure. All tools share a common data schema, enabling seamless ingestion of surface geometry, imagery, and time-series data into a single, coherent experimental record.

Database

X-Hab 2026: LiDAR-Powered Autonomous Charging Service Capability for Surface Rovers and Systems

This document details the timeline of the LiDAR-Powered Autonomous Charging Service Capability for Surface Rovers and Systems project, initiated by the Fall 2025 semester class and completed by the Spring 2026 semester class. This project focuses on developing a fully autonomous system composed of a mobile surface rover and an induction charging station with a robotic arm, both controlled by their own NVIDIA Jetson Orin Nano. Structural improvements to the rover suspension system and body eliminated excessive camber, reduced stress and strain on the plexiglass body, and improved maneuverability and durability of the rover. The charging station robotic arm was fully redesigned to increase reach while minimizing weight and increasing misalignment tolerance during docking on uneven terrain. Electrical system improvements addressed previous torque and power limitations of both the rover and charging station arm. High-torque servo motors were selected based on updated calculations which incorporated terrain slope and Factor of Safety, enabling zero-point turning for the rover and increased payload capacity of the charging station arm. Significant progress was made in autonomy and perception. The rover now employs 3D LiDAR and SLAM mapping for localization, mapping, and path planning. The Battery Monitoring System (BMS) was created to coordinate battery management between the rover and charging station. The BMS provides continuous monitoring of battery state of charge, temperature, current, and will enable the autonomous initiation, execution, and termination of the charging cycle via Bluetooth communication. Testing of the WIBOTIC induction charging system demonstrated reliable power transfer under both aligned and misaligned conditions. This project demonstrated the ability of an autonomously navigating surface rover to independently plan a path to the charging station, dock, and the charging station to autonomously deploy a robotic charging arm and initiate charging of the rover. This work details the progress made to demonstrate the feasibility of autonomous surface rover navigation and recharging systems.

Megan Steele

Monitoring Depolymerization in Mesopores Using Dynamic Properties of Polymeric Melt Accessed via Dielectric Spectroscopy

Traditional design principles for heterogeneous catalysis guide the use of catalytic particles with mesosized (∼2–50 nm) pores to increase the number of surface-active sites by way of an increased surface area. However, the entry of long-chain polymers into such pores may be significantly limited by the size and entanglement of polymers in the melt state, thereby decreasing the number of accessible sites. Assessment of catalyst performance from traditional reactor-based studies averages over intrapore reaction events as well as reactions on the surface of a particle, resulting in an inability to distinguish between differences in site accessibility and activity. Techniques that assess the intrapore performance can inform the design of future heterogeneous catalysts for polymer upcycling. In this work, we demonstrate the use of broadband dielectric spectroscopy to monitor depolymerization of a polymer melt within mesopores via changes in the segmental relaxation time scale of amorphous polymer chains. In particular, we highlight the use of an anodic aluminum oxide (AAO) membrane as a readily available model for catalyst pores with a well-characterized pore morphology. The decrease in the segmental relaxation (α-relaxation) time of the melt with increasing chain scission emerges as a measure of the extent of polymer deconstruction inside mesopores. To demonstrate the utility of this technique, we demonstrate the decomposition of two commercial poly(propylene carbonate) polymers with different decomposition rates within mesopores. As the polymers depolymerize, their segmental relaxation time decreases as the molecular weight decreases (as predicted by the Fox–Flory equation). The BDS-measured change in segmental relaxation time mirrors the expected trend based on change in molecular weight measured by size exclusion chromatography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Scientific Highlights and Status of the Mars Science Laboratory Mission, Years 9 through 12

We present the scientific highlights and status from years 9-12 of NASA’s Mars Science Laboratory mission, with its Curiosity rover. A thermochemolysis-based sample analysis revealed a variety of organic molecules preserved in clay mineral-rich lake/lake margin deposits of the Glen Torridon region. The stratigraphically higher clay-sulfate mineral transition on Aeolis Mons was found to be associated with a lithological change from lacustrine to dry aeolian depositional environments. Water intermittently returned to the surface after the increase in aridity, including during the deposition of wave ripple strata which indicate a climate capable of sustaining an ice-free lake in the early Hesperian. The overlying Mg sulfate-bearing unit has both poly- and monohydrated Mg sulfates and is also enriched in iron carbonate of a purity consistent with chemical sedimentation and therefore atmospheric sequestration. A channel-incised canyon within Gediz Vallis and distal alluvial deposits recorded numerous fluvial and debris flow events after the deposition, lithification, and erosion of the clay- and sulfate-bearing units. Bright clasts found in Gediz Vallis canyon are composed of native sulfur. The investigation of the modern atmosphere and environment focused on the influence of the crater and mountain topography and captured high-altitude noctilucent and iridescent clouds. Radiation monitoring now spans an 11-year solar cycle. Rover systems and science instruments remain capable of addressing mission scientific objectives. All ten scientific instruments continue to return high-value data despite degradation of the Chemistry and Camera instrument’s high-voltage system, loss of multispectral imaging capability, and loss of active neutron spectroscopy. The mission has mitigated the loss of redundant brakes on two arm joints, additional wheel wear, and highly reduced capability of the redundant flight computer. Efficiency improvements in rover energy utilization and operations staffing have allowed the mission team to maintain a high level of productivity despite declining rover power generation and funding.

Mars

Physical and Operational Status of the Photovoltaic Systems in the Municipality of Pinotepa de Don Luis, Oaxaca, One Year after Their Installation [Estado fisico y operativo de los sistemas fotovoltaicos en el municipio de Pinotepa de Don Luis, Oaxaca un ano despues de su instalacion]

In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.

14 SOLAR ENERGY

Statistical Uncertainty of Inhalation Dose Coefficients: Impact of Particle Deposition in ICRP 66 Human Respiratory Tract Model

Inhaled radioactive materials can pose a long-term health concern, as the material can be incorporated into the body’s metabolic pathways and remain in organs and tissues for extended durations. During the retention period, the radioactive material may localize in a source organ and irradiate adjacent target organs and tissues. Distribution of these materials changes over time, requiring biokinetic modeling to evaluate their movement through various tissues and organs. The evolving distribution depends on multiple inputs characterizing the inhaled material, such as particle size and size distribution, particle density, aspect ratio, specific radionuclide, the chemical form, and solubility. In addition, biological parameters such as breathing rate, breathing type (nasal or nasal/oral), respiratory system morphometry, tidal volume, functional residual capacity, and anatomical dead space all influence material transport. These aerosol properties and physiological characteristics of the respiratory tract jointly define a range of initial conditions that influence the time-dependent distribution of radioactive material. To evaluate both uncertainty in the initial conditions of inhalation exposure and the final output (committed effective dose) from biokinetic models, a Python-based software tool, Radiological Exposure Dose Calculator (REDCAL), was developed to propagate uncertainty within the human respiratory tract model. Focusing on deposition fraction uncertainty, the primary objective was to characterize the initial activity distribution across respiratory regions as a function of anticipated particle sizes and distributions. The impact of the deposition fraction uncertainty was propagated to committed effective dose coefficients for selected radionuclides in a companion publication. For each particle size, a lognormal distribution, characterized by its geometric mean as defined within ICRP Publication 66, serves as the basis for introducing uncertainty into the physical processes governing deposition in various lung regions. Finally, this study addresses the deposition process and examines how uncertainty in deposition mechanisms affects activity distribution in the airways, ultimately presenting the expected range and standard deviation of deposited activity as a function of particle size.

International Commission on Radiological Protectio