Search NASASearch

SEARCH · Search NASA

Results for “Requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

608 records · Page 32

Enhancing Nasa Sounding Rocket Capabilities Through Composite Material Adoption

Sounding rockets are a suborbital research platform employed by NASA for heliophysics, astrophysics, and geospace science investigations, and for technology development. They follow semi-parabolic trajectories and are launched using surplus military, and commercial, solid-propellant rocket motors. NASA sounding rocket payloads are comprised of standard, modular subassemblies, designed to perform specific functions critical to achieving mission success criteria. Since the program’s inception, payload length and mass have trended upwards, limiting the capability of the platform to reach exospheric apogees and decreasing the time above critical altitudes to observe solar and celestial targets. To offset this trend, composite materials may be of use in payload and subsystem design to decrease payload mass. This investigation seeks to understand if there is a practical benefit to introducing composite materials on the NSRP by assessing mission specific impacts to those missions conducted in fiscal year 2024. To accurately estimate the mass of a composites-based payload, a standard subsystem (NIACS) underwent structural reconfiguration. Materials were selected that align with NSRP design, manufacturing, and testing standards. NIACS reconfiguration resulted in a mass reduction of 19.6% which was then applied to the payload system in entirety. Using vehicle performance carpet plots, delta apogee and time above the Kármán line were determined. Performance improvements were then evaluated against that mission’s success criteria to determine if that mission would have benefitted from using composite materials. On average, each mission would have gained 59.8 kilometers apogee and 62.9 seconds above the Kármán line. However, only nine of the seventeen missions would have benefitted from these performance improvements. Two of the missions could have used a lower-impulse launch vehicle to achieve mission success. Upleg stability met programmatic criteria; downleg instability and dynamic pressure improved, showing that ballast would not offset the mass reduction of using composite materials. Cost analysis showed that production costs will increase 39%. For the two missions that could have used a lower-impulse launch vehicle, the cost of the launch vehicle would have offset payload production costs. In summary, composite materials are not recommended for universal use on NASA sounding rocket payloads due to unclear programmatic benefits and added cost. However, they are justified for optical astrophysics and heliophysics missions, high-apogee (exosphere) requirements, or when they reduce payload costs versus higher impulse launch vehicles. Reflown, recoverable subsystems should use composites to enhance apogee and observation time.

Robert Henry Burth

Demonstration of gold nanorod systems for enhanced total efficiency: Experimental and numerical analysis

This study investigates the photothermal performance of gold nanorods engineered to exhibit longitudinal plasmon resonances at 695 nm, 780 nm, and 970 nm. The work combines synthesis, structural characterization, extinction measurements, numerical modeling, and controlled temperature experiments to quantify how nanorod geometry, resonance tuning, concentration, and chamber shape jointly influence heat generation. Transmission electron microscopy confirms that increasing nanorod aspect ratio systematically shifts the longitudinal plasmon peak toward the near-infrared region. Extinction measurements show strong agreement with theoretical predictions, validating the numerical model across two independent datasets. Three chamber geometries were tested under laser excitation at 640 nm, 808 nm, and 980 nm: an ascending stepped base, a flat base, and a descending stepped base. Without nanorods, the ascending geometry produced the highest efficiency due to enhanced natural convection. After introducing gold nanorods, all geometries exhibited substantial thermal enhancement, with total efficiencies exceeding 20%. The strongest improvement was obtained for nanorods resonant at 780 nm with a mass concentration of 4.6 mg/mL implemented on the descending stepped-base geometry. This performance resulted from the combined effect of spectral overlapping with the 808 nm laser, the highest nanorod concentration, and localized heat accumulation that intensified buoyancy-driven flow. The findings demonstrate that total efficiency is governed by a synergistic interplay between optical resonance, nanoparticle concentration, and macroscopic chamber design, revealing the system-level coupling between nanoscale plasmonic absorption and macroscale heat-transfer phenomena. The results provide a validated framework for tuning nanoscale plasmonic absorbers and optimizing thermal systems for applications requiring efficient light-to-heat conversion.

77 NANOSCIENCE AND NANOTECHNOLOGY

Systems Engineering and Analysis in Support of a US Federal Staging Facility for UNF

The US Department of Energy Office of Nuclear Energy (DOE-NE) Office of Spent Fuel and High-Level Waste Disposition is examining a set of system options and conducting supporting analyses to inform the development of an integrated waste management system, which may include one or more federal staging facilities (FSFs) for used nuclear fuel (UNF ) sited using a collaborative siting process. This paper focuses on the ongoing activities in two systems engineering and analysis work areas: (1) data and tools development, validation, and maintenance and (2) systems engineering execution. Within the first work area, the STANDARDS 5.0 UNF data and analysis tool, formerly known as UNF-ST&DARDS, is being developed as a foundational resource to assist in the management of UNF data. It has the key capability to model UNF throughout the entire back end of the fuel cycle. STANDARDS also includes several compatible analysis tools for the time-dependent characterization of UNF and related systems by interfacing with the SCALE code system for nuclear analysis and COBRA-SFS for thermal analysis. Also, within the data and tools area is the Next Generation System Analysis Model (NGSAM), which is an agent-based simulation software tool expressly designed to be capable of modeling the waste management system, including the transportation of UNF to and from a FSF. NGSAM has been developed to enable informed decision-making by providing the capability to analyze various potential system options for the management of UNF and high-level radioactive waste. Finally, in the systems engineering execution area, the team has begun to apply a disciplined systems engineering approach at the system level along with supporting analysis to guide the development of the FSF project requirements (including associated transportation infrastructure). Systems engineering principles and practices and their adaptation/application to design and development activities will ensure that the waste management system is effectively implemented as work proceeds. Other activities include investigating the implications of changes in various assumptions and parameters related to waste management systems, such as UNF acceptance rates, receipt logic, facility capacities and capabilities, use of standardized canisters, and different assumed facility operation start dates. Keywords: federal staging facility (FSF), used nuclear fuel (UNF), integrated waste management (IWM) system, Next Generation System Analysis Model (NGSAM), STANDARDS, systems engineering

Joseph, Robert

U.S. Pacific Coast Workshop Report on Preconstruction Research Recommendations (U.S. Offshore Wind Synthesis of Environmental Effects Research (SEER) Project)

In May 2022, the U.S. Offshore Wind Synthesis of Environmental Effects Research (SEER) project team hosted a stakeholder workshop focused on preconstruction (baseline) research needs for potential floating offshore wind (OSW) energy development on the U.S. Pacific Coast, including California, Oregon, and Washington. Prior to the workshop, the SEER team developed a set of initial synthesized research recommendations that were identified based on a review of relevant, publicly available resources and with advisory group input. The workshop covered three marine life breakout groups on subsequent days to discuss research recommendations related to 1) marine mammals and sea turtles, 2) fish and invertebrates, and 3) birds and bats. As part of the workshop, over a hundred participants from the public and private sectors provided feedback on various aspects of the initial research recommendations, including associated data and knowledge gaps, benefits/limitations of available methods and technologies, and technological advancements or infrastructure needed to address the recommendation. Approximately 1,000 total comments were received on the workshop MURAL boards and were synthesized in this report. Based on workshop feedback, SEER developed a final database of over 500 specific research recommendations based on more than 40 resources. In Fall 2022, the full database and a tool with updated synthesized research recommendations were disseminated on Tethys (https://tethys.pnnl.gov) to assist with informing future funding opportunities and research programming. There is a continued need to improve awareness of the potential environmental effects, monitoring technologies, and management strategies for floating OSW energy development on the U.S. Pacific Coast. Coordination of these activities will require the sustained involvement of multiple stakeholders from across sectors. Beyond the baseline considerations discussed in this workshop, future state-of-the-science activities should be planned to consider research needs across wind energy life cycle phases for all relevant wildlife taxa and associated habitat and ecosystem processes.

17 WIND ENERGY

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium

Manned Lunar Landing Via Rendezvous

In any mission description, the vehicles, the flight profiles, and the astrionics hardware to im- plement the mission are all tightly interwoven things. A final result evolves only after many iterations to the solution are made. This paper will describe one of these iterations in the Saturn C-5 Earth Orbit Rendezvous approach to the Manned Lunar Landing Program. Since the iter- ation to be described in an nthone, there exists some basis for the hope that the perturbation from the final solution is small. This paper is not concerned with the landing itself, but only with those operations leading to injection of the space craft into the lunar trans- fer trajectory. However, as is to be expected, it is the target conditions which set the pace for the overall operation. The entire operation must be sized to culminate at a time and place which places the lunar target in an attainable position. The procedure would call for a burst of activity lasting over a relatively short time as compared to the long and extensive preparations leading up to it. The activity must be aimed at the opening of the lunar "launch window". Figure 1 illustrates the variation in the velocity increment required to launch a vehicle into a lunar transfer trajectory from a 485 kilometer earth orbit. The minima are at irregularly spaced intervals and are a func- tion of the inclination of the lunar and the earth satellite planes and of the position of the moon in its orbit around the earth (i. e. , the day of the month). In an operations analysis these spacings will influence the number of vehicles on the launch pad (primary and back-up) , their state of readi- ness, the firing rate, and also the flight profile to be chosen. Whether it is decided to go by "con- necting" or by "tanking" mode, the objective must be to get the spacecraft in the launch ready state at the opening of one of these launch windows. It may be desired that the first vehicle be capable of remaining in a functionally capable state even after bridging one or more of the gaps between the windows. This consideration will influence the design of the vehicles as well as the operational modes to be designed into the flight control hard- ware. For example, a sleep switch may be de- sirable from the standpoint of savings in battery we ight.

LUNAR LANDING

Additive‐Free Oxidized Spiro‐MeOTAD Hole Transport Layer Significantly Improves Thermal Solar Cell Stability

Perovskite solar cells are among the most promising new solar technologies, already surpassing polycrystalline silicon solar cell efficiencies. The stability of the highest efficiency devices at elevated temperature is, however, poor. These cells typically use Spiro-MeOTAD as the hole transporting layer. It is generally believed that additives, required for enhancing electrical conductivity and optimizing energy level alignment, are responsible for the reduced stability—inferring that Spiro-MeOTAD based hole transporting layers are intrinsically unstable. Here, a reliable noble metal free synthesis of Spiro-MeOTAD (bis(trifluoromethane)sulfonimide) 4 is presented which is used as the oxidizing agent. No additives are added to the partially oxidized Spiro-MeOTAD hole-transporting layer. Device efficiencies up to 24.2% are achieved. Electrical conductivity is largely developed by the first 1% oxidation. Further oxidation shifts the energy levels away from the vacuum level, which allows tuning of the energy level alignment without the use of additives—contradicting the current understanding of this system. Without additives, devices demonstrate significant improvement in stability at elevated temperatures up to 85 °C under one sun over 1400 h continuous illumination. The remaining degradation is pinpointed to ion migration and reactions in the perovskite layer which may be further suppressed with compositional engineering and adequate ion barrier layers.

14 SOLAR ENERGY

Nonequilibrium dynamics of two-level systems directly after cryogenic alternating bias

Two-level systems (TLSs) are a dominant decoherence mechanism in superconducting qubits, microwave kinetic inductance detectors, and quantum dots. TLSs are tunneling states commonly found in amorphous materials and interfaces, which interact electromechanically, leading to energy loss. Fluctuations in the frequency of the TLSs are a significant problem for qubit operation and force recalibration every few hours. In this study, we probe the effect of alternating bias at cryogenic temperatures on TLSs in a purpose-built LC oscillator. When an in situ alternating bias is applied, the steady-state spectra of the TLSs disappear. Spectroscopy reveals transient behavior, in which the TLS frequency fluctuates on the order of minutes. Thermal cycling above 10 K reverses these effects, restoring the TLS spectrum to its original state. Importantly, the intrinsic loss tangent of the LC oscillator remains unchanged before and after the application of the alternating bias. We propose that the disappearance of the steady-state spectrum is caused by nonequilibrium energy buildup from strain in the oxide film introduced by the pulsed voltage-bias sequence. Understanding this nonequilibrium energy could shed light on TLS fluctuations and reduce the calibration requirements for qubits.

general physics

From Exploration Flight Test-1 to Artemis II--A NASA Langley's Orion Aerosciences Overview

The Orion Aerosciences program at NASA Langley has played a central role in advancing the aerodynamic and aeroheating prediction capabilities required for the Orion crew vehicle’s return from deep space. This presentation provides a technical overview of aerosciences contributions spanning Exploration Flight Test-1 (EFT-1), Artemis I, and the ongoing post-flight analysis of Artemis II. EFT-1 provided the first high-energy entry dataset for Orion, enabling critical validation of aerodynamic force and moment predictions, static and dynamic stability characteristics, and aeroheating environments at relevant flight Mach and Reynolds numbers. Flight-derived pressure data were used to refine the Flush Air Data System (FADS) methodology for atmospheric density reconstruction and to improve Best Estimated Trajectory (BET) solutions. The EFT-1 data also offered key insights into heat shield performance, including char layer recession, in-depth thermal response, and material retention behavior under flight conditions, informing updates to both thermal response models and uncertainty quantification practices. Building on EFT-1, Artemis I extended the database to true lunar-return conditions. Observations of heat shield performance, including localized char loss, bondline response, and recession variability, provided an unprecedented opportunity to reassess Thermal Protection System (TPS) and aeroheating modeling assumptions. Aerodynamic reconstruction efforts incorporated improved FADS calibration, enhanced atmospheric modeling, and refined force and moment databases to reduce trajectory and load uncertainties. Aeroheating comparisons between pre-flight predictions and flight data enabled targeted model updates, particularly in transitional flow environments and wake heating regions. For Artemis II, these lessons were systematically incorporated into the pre-flight prediction process. Updates included refined aerodynamic databases anchored to flight-validated corrections, improved density estimation and BET methodologies using enhanced database interpolation algorithm and FADS modeling, and revised aeroheating design environments informed by Artemis I material response observations. By the time of the workshop, Artemis II post-flight analysis will be underway, and preliminary findings will be presented where available, including early comparisons of aerodynamic reconstruction, atmospheric density estimation, and thermal protection system performance relative to updated predictions. Collectively, this body of work is a testament to the dedicated and multidisciplinary team whose sustained efforts have contributed to the program’s success and to the progressive maturation of Orion aerosciences modeling through numerical modeling, ground and flight data assimilation. The integrated advancement of aerodynamics, trajectory reconstruction, FADS-based density estimation, and aeroheating analysis has reduced predictive uncertainty and strengthened confidence for future crewed lunar and deep-space missions.

Orion

Draft ASME Code Case to qualify L-PBF 316H material for Section III, Division 5 applications

This report documents the AMMT program’s development and submission of a draft ASME Code Case to qualify Laser Powder Bed Fusion (L PBF) Type 316H stainless steel for Section III, Divi-sion 5 Class A and SM high temperature nuclear applications. It summarizes the technical basis, the comprehensive high temperature mechanical test database assembled between 2023–2026, and the proposed code language and qualification framework submitted to ASME. The work was co-ordinated across multiple national laboratories and leverages prior ASME efforts to integrate additive manufacturing into the Boiler & Pressure Vessel Code. The body of the report describes the experimental database and analysis supporting the Code Case: tensile, creep, fatigue, creep fatigue, and thermal aging tests collected from multiple additive manufacturing sites, machine types, and powder lots, with material processed by a solution anneal heat treatment. The dataset — including both full size and subsized specimens and tests oriented parallel and perpendicular to build direction — shows limited tensile anisotropy, tensile properties comparable to wrought 316H, creep strength within the scatter of wrought material, but markedly reduced creep ductility above about 650 °C associated with rapid σ phase formation in L PBF microstructures. The draft Code Case itself prescribes a staged qualification model (manufacturing process qualification, component qualification, and per build witness testing), treats L PBF components as equivalent to Type 316 weld metal for design and inspection, and requires mechanical, chemical, and metallographic controls tied to ASTM/ISO 52946. Key acceptance criteria include tensile tests within a 90% prediction interval of the AMMT dataset, a creep fatigue screening test adapted from ASME Section III, Division 5, Subsection HB, HBB 2800 but with the cycle acceptance reduced to 100 for L PBF material, and double volumetric inspection of production components. The report concludes that the present data support treating L PBF 316H as analogous to conventional fusion weld metal for Division 5 design and inspection, while highlighting important caveats: the σ phase driven loss of creep ductility above ~650 °C, preliminary indications of enhanced creep fatigue sensitivity in some lots, and remaining gaps in long term aging and additional cyclic testing. Recommended next actions include completing outstanding cyclic and long duration creep/aging tests on the solution annealed condition, supporting inclusion of the 316H chemistry and heat treatment in ASTM/ISO 52946, and continuing engagement with ASME and NRC during balloting and review to enable industry adoption.

Messner, Mark C. (ORCID:0000000200404385)

Radio Metric Errors Due to Mismatch and Offset Between a DSN Antenna Beam and the Beam of a Troposphere Calibration Instrument

Two components of the error of a troposphere calibration measurement were quantified by theoretical calculations. The first component is a beam mismatch error, which occurs when the calibration instrument senses a conical volume different from the cylindrical volume sampled by a Deep Space Network (DSN) antenna. The second component is a beam offset error, which occurs if the calibration instrument is not mounted on the axis of the DSN antenna. These two error sources were calculated for both delay (e.g., VLBI) and delay rate (e.g., Doppler) measurements. The beam mismatch error for both delay and delay rate drops rapidly as the beamwidth of the troposphere calibration instrument (e.g., a water vapor radiometer or an infrared Fourier transform spectrometer) is reduced. At a 10-deg elevation angle, the instantaneous beam mismatch error is 1.0 mm for a 6-deg beamwidth and 0.09 mm for a 0.5-deg beam (these are the full angular widths of a circular beam with uniform gain out to a sharp cutoff). Time averaging for 60-100 sec will reduce these errors by factors of 1.2-2.2. At a 20-deg elevation angle, the lower limit for current Doppler observations, the beam-mismatch delay rate error is an Allan standard deviation over 100 sec of 1.1 x 10 -14 with a 4-deg beam and 1.3 x 10 -15 for a 0.5-deg beam. A 50-m beam offset would result in a fairly modest (compared to other expected error sources) delay error (less than or equal to 0.3 mm for 60-sec integrations at any elevation angle is greater than or equal to 6 deg). However, the same offset would cause a large error in delay rate measurements (e.g., an Allan standard deviation of 1.2 x 10 -14 over 100 sec at a 20-deg elevation angle), which would dominate over other known error sources if the beamwidth is 2 deg or smaller. An on-axis location is essential for accurate troposphere calibration of delay rate measurements. A half-power beamwidth (for a beam with a tapered gain profile) of 1.2 deg or smaller is desired for calibration of all types of radio metrics. A water-vapor radiometer calibration beam of this size with very low sidelobes would require a clear aperture antenna with a diameter of at least 1.5 m if the primary water vapor sensing channel were in the 20-22 GHz range.

R P Linfield

A SIMULINK Environment for Flight Dynamics and Control Analysis - Application to the DHC-2 'Beaver', Part 1. Implementation of a Model Library in SIMULINK

The design of advanced Automatic Aircraft Control Systems (AACS's) can be improved upon considerably if the designer can access all models and tools required for control system design and analysis through a graphical user-interface, from within one software environment. This MSc-thesis presents the first step in the development of such an environment, which is currently being done at the Section for Stability and Control of Delft University of Technology, Faculty of Aerospace Engineering. The environment is implemented within the commercially available software package MATLAB/SIMULINK. The report consists of two parts. Part I gives a detailed description of the AACS design environment. The heart of this environment is formed by the SIMULINK implementation of a nonlinear aircraft model in block-diagram format. The model has been worked out for the old laboratory aircraft of the Faculty, the De Havilland DHC-2 'Beaver', but due to its modular structure, it can easily be adapted for other aircraft. Part I also describes MATLAB programs which can be applied for finding steady-state trimmed-flight conditions and for linearization of the aircraft model, and it shows how the built-in simulation routines of SIMULINK have been used for open-loop analysis of the aircraft dynamics. Apart from the implementation of the models and tools, a thorough treatment of the theoretical backgrounds is presented. Part II of this report presents a part of an autopilot design process for the 'Beaver' aircraft, which clearly demonstrates the power and flexibility of the AACS design environment from part I. Evaluations of all longitudinal and lateral control laws by means of nonlinear simulations are treated in detail. The AACS design environment from part I proved to be a very useful tool for designing the control laws of the 'Beaver' autopilot within a very tight time-schedule. The autopilot design process itself will be used as a guideline for future AACS research at the Faculty of Aerospace Engineering. Flight tests of the 'Beaver' autopilot, done after evaluating the control laws in the SIMULINK package, proved to be quite successful. In the future, the AACS design package will evolve into a standardized, integrated design environment which can be applied to virtually any type of aircraft. The AACS design cycle will be shortened further by developing tools for automatically porting control laws from the MATLAB/SIMULINK environment to a piloted real-time flight simulator and the Flight Control Computers of the aircraft.

Aircraft Modelling

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Dimensional Reduction for Sampled Priors and Application to Photometric Redshift Distributions

A typical Bayesian inference on the values of some parameters of interest q from some data D involves running a Markov Chain (MC) to sample from the posterior $p$($q$,$n$|$D$) $\propto$ $\mathcal{L}$($D$|$q$,$n$)$p$(q)$p$($n$), where n are some nuisance parameters with a separable prior. In some cases, the nuisance parameters are high-dimensional, and their prior p(n) is itself defined only by a set of samples that have been drawn from some other MC. The MC for the posterior will typically require evaluation of p(n) at arbitrary values of n, i.e., one needs to provide a density estimator over the full n space from the provided samples. But the high dimensionality of n hinders both the density estimation and the efficiency of the MC for the posterior. We describe a solution to this problem: a linear compression of the n space into a much lower-dimensional space u, which projects away directions in n space that cannot appreciably alter $\mathcal{L}$. The algorithm for doing so is a slight modification to principal components analysis, and is less restrictive on p(n) than other proposed solutions to this issue. We demonstrate this “mode projection” technique using the analysis of 2-point correlation functions of weak lensing fields and galaxy density in the Dark Energy Survey, where n is a binned representation of the redshift distribution n(z) of the galaxies.

79 ASTRONOMY AND ASTROPHYSICS

Biochemical properties of glycerol kinase from the hypersaline-adapted archaeon Haloferax volcanii

ABSTRACT Extremophilic microorganisms are promising candidates for industrial and analytical biocatalysis.Haloferax volcanii, a halophilic archaeon that prefers glycerol over glucose, channels this substrate into central metabolism through glycerol kinase (GK). Here, we report the biochemical properties ofH. volcaniiGK and its potential for biotechnological applications. An N-terminal His-tagged GK was functionalin vivoand yielded 3 mg/L culture—4.5 times more enzyme than a C-terminal StrepII-tagged version. Size exclusion chromatography revealed a glycerol-induced oligomeric shift from homodimer to a dimer-dominant state with detectable tetramer. The purified enzyme showed robust activity across broad pH and salinity ranges, with optimal activity at 100 mM NaCl and 50°C–60°C. It retained catalytic activity in 5%–10% dimethyl sulfoxide (DMSO) and crude glycerol containing methanol. His-GK was freeze-thaw stable and thermotolerant in 2 M NaCl buffers. In the absence of ligands, the enzyme’s melting temperature (T m ) was 80°C. Glycerol increased the T m to 85°C, and combinations with MgCl₂ (84°C) or ATP (88°C) provided further stabilization. The highest T m (89°C) occurred with all three ligands, suggesting a cumulative stabilizing effect. Kinetic analyses revealed positive cooperativity for glycerol, ATP, and Mg² + ; Mn² + and Co² + also supported the activity.H. volcaniiGK is the first known GK to exhibit positive cooperativity with glycerol and ATP. Its high stability and substrate flexibility support its use in biodiesel waste valorization,in vitrobiocatalysis, and biosensor development—applications demanding robust, specific, and stable enzymes. IMPORTANCE This study reveals thatH. volcaniiGK exhibits positive cooperativity for glycerol, ATP, and Mg² + , a kinetic feature not previously reported for glycerol kinases. This behavior enables steep, switch-like responses to small substrate changes, offering unique advantages for biosensor design. Importantly,H. volcaniiGK also maintains high activity under extreme salinity, temperature, broad pH, and solvent conditions that typically limit enzyme use in industrial and environmental applications. These traits make this GK an ideal candidate for enzyme-based biosensors, which often suffer from poor tolerance to pH, solvent, and thermal stress. Its robustness supports its use in cross-linked enzyme crystals, an immobilization method that enhances enzyme stability and reusability under harsh conditions. Moreover, GKs are already employed in Mg² + detection kits; however,H. volcaniiGK’s ability to tolerate and respond to diverse divalent cations (e.g., Co² + , Mn² + ) broadens their potential for pollutant detection and environmental monitoring. These features collectively positionH. volcaniiGK as a valuable biocatalyst for biosensing,in vitrodiagnostics, and biotechnological applications requiring both precision and durability.

Biotechnology & Applied Microbiology

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains Task 3: Lifetime and Reliability of Electrical Insulators

This research project was a collaborative investigation between researchers at the RTX Technology Research Center (RTRC) and the University of Texas at Austin and made a significant contribution to enabling electric aircraft. The transport of electric power between the points of generation and use requires power cables. These cables must be smaller, lighter and provide a more predictable life than power cables used in stationary applications. Consequently, this investigation provided heretofore unavailable information supporting the safety and reliability of smaller lighter power cables for electrified aircraft. In addition, the research identified key additional engineering data needed to support quantitative reliability assessments. Important advances included: • Demonstrated that at least one manufacturer can make a novel, smaller, lighter power cable that is free from serious defects. • Developed and published an appropriate analytical construct to describe the life of this novel cable. This is a necessary step for use in aviation where the understanding of remaining life is critical. • Demonstrated thermal-mechanical aging that suggested 1000+ flights before the thermal-mechanical processes produced defects large enough that the defect growth was accelerated electrically. • Showed that electrical aging took place at two rates. The first possibly lasting weeks to months and the second possibly days to weeks. If robust, this provides a good diagnostic for cable replacement. • Demonstrated that the traditional electrical testing of cable materials using manufactured voids can be misleading due to the size of the voids. Emerging laser drilling technology permitted demonstration that the physics of failure in realistically small voids is different from that in the unrealistically large voids used in earlier research, which is very important for high-quality, high-performance, small aircraft cables. Although this project represents a significant contribution to the specifics of cable aging in the aircraft environment, important additional research remains to be completed, including: • Non-uniform thermal cycling by applying the heat from the center conductor to maximize thermal stress next to the core area where the electric gradient is the strongest. This builds on the uniform thermal cycling that has been completed. • The augmentation of the thermal-mechanical failure rate by electrical processes. Better understanding of these time constants strongly affects the ability to predict life. • Termination design: Terminations provide not only electrical reflection potential, but a location for a series arc fault and an area where ozone can diffuse into the center conductor and negatively affect cable insulation. • The abrasion and ozone resistance of the cable jacket. • Pressure cycling as an accelerant of thermal, mechanical, and/or electrical aging. • Possible methods for online PD detection and offline PD localization

model

Airports as Energy Nodes Activity Summary

Advanced aircraft concepts that use non-traditional aviation energy storage methods such as batteries or cryogenic hydrogen are in development and expected to enter regular service at airports worldwide within the next decade. The energy needs for these aircraft may quickly overwhelm the existing energy infrastructure at airports, particularly at smaller and more remote facilities. Without energy upgrades, these airports will not be able to host these advanced vehicles, but without the advanced vehicle traffic, these airports will not have the rationale or funding to build up their energy infrastructure. The Airports as Energy Nodes (ÆNodes) activity, a collaboration between the National Aeronautics and Space Administration (NASA) and the National Renewable Energy Laboratory (NREL), was executed to understand and model the energy needs that advanced aircraft concepts may levy on these smaller airports, determine cost-effective approaches to enhance the airport energy infrastructure, and demonstrate the enhanced resilience of these energy infrastructure upgrades to the airport and surrounding community via “digital twin” simulation at relevant energy and dynamic time scales. The ÆNodes team also investigated future reference aircraft designs and materials to enable cryogenic hydrogen storage for aircraft. The ÆNodes team conducted analysis at two U.S. airport partner sites — Winchester Regional Airport in Winchester, Virginia, and Tweed/New Haven Airport in New Haven, Connecticut. The goal of this partnership was to develop data and reference infrastructure designs that could accommodate advanced aircraft in the future at these airports while also enhancing the resiliency of the energy supply to the surrounding airport community, which could be used to capture funding to enable the infrastructure upgrades. Over the course of the study, a method was developed to estimate air traffic requiring advanced energy services over the course of a year using a mix of historical data and companion studies on advanced aircraft transportation networks. The study has concluded at NASA but continues at NREL, who will develop a final report discussing the energy infrastructure upgrades and digital twin results. Preliminary results indicate that unrestricted adoption of advanced battery-electric aircraft may double traffic at these airports and increase peak daily power usage by an order of magnitude, while increase electricity energy needs by a factor of two to four. The infrastructure upgrades necessary to accommodate these increased energy needs could be used to provide enhanced energy services to the airport community to offset the cost and increase the utility of the upgrades, which will be described in the NREL final report.

Airports

Statistical Uncertainty of Inhalation Dose Coefficients: Impact of Particle Deposition in ICRP 66 Human Respiratory Tract Model

Inhaled radioactive materials can pose a long-term health concern, as the material can be incorporated into the body’s metabolic pathways and remain in organs and tissues for extended durations. During the retention period, the radioactive material may localize in a source organ and irradiate adjacent target organs and tissues. Distribution of these materials changes over time, requiring biokinetic modeling to evaluate their movement through various tissues and organs. The evolving distribution depends on multiple inputs characterizing the inhaled material, such as particle size and size distribution, particle density, aspect ratio, specific radionuclide, the chemical form, and solubility. In addition, biological parameters such as breathing rate, breathing type (nasal or nasal/oral), respiratory system morphometry, tidal volume, functional residual capacity, and anatomical dead space all influence material transport. These aerosol properties and physiological characteristics of the respiratory tract jointly define a range of initial conditions that influence the time-dependent distribution of radioactive material. To evaluate both uncertainty in the initial conditions of inhalation exposure and the final output (committed effective dose) from biokinetic models, a Python-based software tool, Radiological Exposure Dose Calculator (REDCAL), was developed to propagate uncertainty within the human respiratory tract model. Focusing on deposition fraction uncertainty, the primary objective was to characterize the initial activity distribution across respiratory regions as a function of anticipated particle sizes and distributions. The impact of the deposition fraction uncertainty was propagated to committed effective dose coefficients for selected radionuclides in a companion publication. For each particle size, a lognormal distribution, characterized by its geometric mean as defined within ICRP Publication 66, serves as the basis for introducing uncertainty into the physical processes governing deposition in various lung regions. Finally, this study addresses the deposition process and examines how uncertainty in deposition mechanisms affects activity distribution in the airways, ultimately presenting the expected range and standard deviation of deposited activity as a function of particle size.

International Commission on Radiological Protectio