Search NASA⌕ Search

SEARCH · Search NASA

Results for “materials imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Non-perturbative cathodoluminescence microscopy of beam-sensitive materials

Cathodoluminescence microscopy is now a wellestablished and powerful tool for probing the photonic properties of nanoscale materials, but in many cases, nanophotonic materials are easily damaged by the electronbeam doses necessary to achieve reasonable cathodoluminescence signal-to-noise ratios. Two-dimensional materials have proven particularly susceptible to beam-induced modifications, yielding both obstacles to high spatial-resolution measurement and opportunities for beam-induced patterning of quantum photonic systems. Here pan-sharpening techniques are applied to cathodoluminescence microscopy in order to address these challenges and experimentally demonstrate the promise of pan-sharpening for minimally-perturbative high-spatial-resolution spectrum imaging of beam-sensitive materials.

2D materials↗

Evaluation of ERTS-1 imagery for mapping Quaternary deposits and landforms in the Great Plains and Midwest

The author has identified the following significant results. The main landform associations and larger landforms are readily identifiable on the better images and commonly the gross associations of surficial Quaternary deposits also can be differentiated, primarily by information on landforms and soils. Maps showing the Quaternary geologic-terrain units that can be differentiated from the ERTS-1 images are being prepared for study areas in Illinois, Iowa, Missouri, Kansas, Nebraska, and South Dakota. Preliminary maps at 1:1 million scale are given of two of the study areas, the Peoria and Decatur, Illinois, 1 deg x 2 quadrangles. These maps exemplify the first phase of investigations, which consists of identifying and mapping landform and land use characteristics and geologic-surficial materials directly from ERTS-1 images alone, without input of additional data. These maps shown that commonly the boundaries of geologic-terrain units can be identified more accurately on ERTS-1 images than on topographic maps of 1:250,000 scale. From analysis of drainage patterns, stream-divide relations, and tone and textural variations on the ERTS-1 images, the trends of numerous moraines of Wisconsinan and possibly some of Illinoian age were mapped. In the Peoria study area the trend of a buried valley of the Mississippi River is revealed.

Morrison, R. B.↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat-treated glassy carbon under pressure exhibiting superior hardness, strength and elasticity

Glassy carbon (GC) is a type of non-graphitizing disordered carbon material at ambient pressure and high temperatures, which has been widely used due to its excellent mechanical properties. Here we report the changes in the microstructure and mechanical properties of GC treated at high pressures (up to 5 GPa) and high temperatures. The formation of intermediate sp 2 –sp 3 phases is identified at moderate treatment temperatures before the complete graphitization of GC, by analyzing synchrotron X-ray diffraction, Raman spectra, and transmission electron microscopy images. The intermediate metastable carbon materials exhibit superior mechanical properties with hardness reaching up to 10 GPa and compressive strength reaching as high as 2.5 GPa, nearly doubling those of raw GC, and improving elasticity and thermal stability. The synthesis pressure used in this study can be achieved in the industry on a commercial scale, enabling the scalable synthesis of this type of strong, hard, and elastic carbon materials.

36 MATERIALS SCIENCE↗

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

Preliminary analysis of a CME observed by SOHO and Ulysses Experiments

Over the last week of November 2002 SOHO/LASCO observed several Coronal Mass Ejections, most of which occurring in the NW quadrant. At that time SOHO/UVCS was involved in a SOHO-Sun-Ulysses quadrature campaign, making observations off the west limb of the Sun, at a northern latitude of 27 deg. Here we focus on data taken at 1.7 solar radii, over a time interval of approx. 7 hours, on 26/27 November 2002, when a large streamer disruption was imaged by LASCO C2 and C3 coronagraphs. UVCS spectra revealed the presence of lines from both high and low ionization ions, such as C III, O VI, Si VIII, IX, and XII, Fe X and XVIII, which brighten at different times, with a different time scale and at different positions and are apparently related to different phenomena. In particular, the intensity increase and fast disappearance of the C III 977 Angstrom line represents the passage through the UVCS slit of cold material released in a jet imaged by EIT in the He II 304 Angstrom line. The persistent presence of the Fe XVIII 974 Angstrom line is not easily related to any special feature crossing the UVCS slit. We suggest to interpret this behavior in terms of the reconnection events which lead to the formation of loops observed in the EIT He II 304 Angstrom line.

Bemporad, A.↗

Life in the Atacama - Year 2: Geologic Reconnaissance Through Long-Range Roving and Implications on the Search for Life

The "Life in the Atacama" (LITA) project included two field trials during the 2004 field season, each of which lasted about a week. The remote science team had no prior knowledge of the local geology, and relied entirely on orbital images and rover-acquired data to make interpretations. The sites for these trials were in different locations, and are designated "Site B" and "Site C" respectively. The primary objective of the experiment is to develop and test the means to locate, characterize, and identify habitats and life remotely through long-range roving, which included field testing the rover, named Zoe. Zoe has onboard autonomous navigation for long-range roving, a plow to overturn rocks and expose near-surface rock materials, and high-resolution imaging, spectral, and fluorescence sampling capabilities. Highlights from the experiment included characterizing the geology in and near the landing ellipse, assessing pre-mission, satellite-based hypotheses, and improving the approach and procedures used by the remote and field teams for upcoming experiments through combined satellite, field-based, and microscopic perspectives and long-range roving.

Dohm, J. M.↗

Thermographic phosphor digital image correlation

The invention advances the ratio method of phosphor thermography using two machine vision cameras for full-field temperature measurements of a solid surface. As an example, algorithms from digital image correlation (DIC) can be used to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. A phosphor calibration sample fabricated using aerosol deposition can be used for in situ determination of the temperature-versus-intensity ratio relationship. The full calibration methodology and several improvements on two-color phosphor thermography open the door for full-field temperature measurements in dynamic tests with deforming test specimens. In particular, thermographic phosphors can be combined with stereo digital image correlation in a novel diagnostic, TP+DIC, to measure time-resolved full-field surface strains and temperatures simultaneously, thereby enabling testing in combined thermo-mechanical environments.

Winters, Caroline↗

Systematic variations in the spectral properties of bright regions on Mars

The color and albedo of the martian surface define two basic surface units, dark gray material interpreted as relatively unaltered 'rock' and bright reddish material interpreted as weathered 'soil'. Understanding the processes contributing to soil formation first requires assessment of the soil's composition and compositional diversity. We report first results of an investigation of the character and variability of Fe- and water-bearing phases in bright reddish materials using ISM data. We also explore implications of these results for chemical evolution of martian soil. Information on the composition and distribution of bright reddish material comes from three major sources: Viking images, measurements by the XRF and GCMS instruments on the Viking Landers, and spectroscopic data. The XRF experiment found nearly identical, Fe-rich major-element compositions comparable to weathered basalt. Soil water, amounting to approximately 1-3 wt. percent as measured by the GCMS, was liberated mostly by heating to greater than or equal to 350 C, suggesting that it is present in a chemically bound form. Spectroscopic studies have detected ferric oxide, probably hematite, as well as molecular water. However, the identities of major silicate phases have been controversial, with conflicting evidence regarding phyllosilicates. Two main interpretations of this evidence have been proposed: Weathering of basaltic glasses by H2O and CO2 formed a mixture of oxides, salts, and metastable phyllosilicates such as montmorillonite and 'palagonite' formed when basaltic melt contacted ground ice or water. Palagonite is a hydrated basaltic glass containing dispersed ferric oxide, recrystallized in varying degrees to phyllosilicates. Typically it is aphanitic, although some examples contain phenocrysts. In either case, eolian redistribution is thought to have resulted in the material's global homogenization. Imaging spectroscopic data returned by the ISM instrument on Phobos 2 provide a powerful new basis for evaluating the composition and origin of martian soil because they are indicative of the presence and distribution of water- and Fe-bearing phases whose mineralogy is sensitive to the history of chemical weathering.

Murchie, Scott↗

Use of Constrained Gamma Emission Computed Tomography to Evaluate Fission Product Distributions in High-Temperature Materials from a TRISO Fuel Irradiation

An image reconstruction technique was developed to overcome problems with earlier methods of gamma emission computed tomography of graphite rings surrounding the AGR-3/4 TRISO fission product transport experiment. The profiles obtained from the tomography are compared with sampling done via radially resolved destructive sampling techniques. Generally, there is good agreement between profiles measured via destructive sampling of the rings and the tomographic profiles, though at low signal strengths, the tomographic profiles appear elevated.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nonlinear reversal of photoexcitation on the attosecond time scale improves ultrafast X-ray diffraction images

The complex refractive index of a material governs its light-matter interactions, with intense light fields enabling tailored nonlinear optical responses. In the X-ray regime, rapid photoionization limits the potential of nonlinear techniques by inducing irreversible electronic damage. Here we demonstrate that intense, sub-femtosecond X-ray pulses, shorter than typical Auger decay times, can partially reverse photoexcitation via stimulated emission near atomic resonances. By analyzing thousands of coherent diffraction patterns and ion spectra from neon nanoparticles exposed to sub-fs and 15-fs pulses, we observe enhanced X-ray diffraction alongside reduced energy absorption for sub-fs pulses. Theoretical modeling attributes this to dynamics akin to Rabi flopping that prolong the lifetime of resonant states and suppress electronic bleaching. These findings suggest that ultrashort, intense X-ray pulses enable active control of X-ray refractive index and damage pathways, opening avenues for improved high-resolution imaging and nonlinear spectroscopy in complex nanoscale systems.

Ulmer, Anatoli [Universität Hamburg (Germany)] (OR↗

Computational toolkit for predicting thickness of 2D materials using machine learning and autogenerated dataset by large language model

The thickness of 2D materials not only plays a crucial role in determining the performance of nanoelectronic and optoelectronic devices but also introduces complexities in predicting volume-dependent properties, such as energy storage capacity, due to the intrinsic vacuum within these materials. Although a plethora of experimental techniques, including but not limited to optical contrast, Raman spectroscopy, nonlinear optical spectroscopy, near-field optical imaging, and hyperspectral imaging, facilitate the measurement of 2D material thickness, comprehensive data for many materials remain elusive. Over the past decade, the exponential proliferation of 2D materials and their heterostructures has outstripped the capabilities of conventional experimental and computational approaches. In this evolving landscape, machine learning (ML) has emerged as an indispensable tool, offering a scalable approach to augment these traditional methodologies. Addressing the critical gap, we introduce THICK2D—Thickness Hierarchy Inference and Calculation Kit for 2D Materials. This Python-based computational framework harnesses an autogenerated thickness database, developed using large language models, and advanced ML algorithms to facilitate the rapid and scalable estimation of material thickness, relying solely on crystallographic data. To demonstrate the utility and robustness of THICK2D, we successfully used the toolkit to predict the thickness of more than 8000 2D-based materials, sourced from two extensive 2D materials databases. THICK2D is disseminated as an open-source utility, accessible on GitHub at https://github.com/gmp007/THICK2D, and archived on Zenodo at https://10.5281/zenodo.11216648.

Ekuma, Chinedu E. (ORCID:0000000258527556)↗

Osiris-Rex Post-Tag Observation Trajectory Design and Navigation Performance

NASA’s OSIRIS-REx spacecraft successfully collected a sample of asteroid regolith from the surface of near-Earth asteroid Bennu in October of 2020. Subsequent imaging of the sampler head showed material leaking from the collection mechanism, thus stowage of the sample precluded execution of any planned maneuvers in the following days. Optical navigation imaging also ceased in the days following sample collection. The desire to image the sample site to investigate the results of the spacecraft-to-surface interaction led to the Navigation team designing a trajectory to return to Bennu after several months in order to image the surface one final time. After several iterations a trajectory design was created that satisfied the numerous constraints that were levied in order to place utmost importance on the safety of the spacecraft and stowed sample, while also closely emulating previously obtained imaging conditions to provide a close comparison of site pre- and post-contact. Significant analysis was necessary in order to reliably reacquire the asteroid after several months without optical navigation imagery. The final design required five maneuvers to return the spacecraft to Bennu and perform a final flyby of the asteroid at a distance of 3.8 kilometers. Successful execution of the phase provided key insights regarding the performance of the sample collection activities and the subsurface composition of the asteroid.

Daniel R Wibben↗

Finite Element Modeling of the Thermographic Inspection for Composite Materials

The performance of composite materials is dependent on the constituent materials selected, material structural geometry, and the fabrication process. Flaws can form in composite materials as a result of the fabrication process, handling in the manufacturing environment, and exposure in the service environment to anomalous activity. Often these flaws show no indication on the surface of the material while having the potential of substantially degrading the integrity of the composite structure. For this reason it is important to have available inspection techniques that can reliably detect sub-surface defects such as inter-ply disbonds, inter-ply cracks, porosity, and density changes caused by variations in fiber volume content. Many non-destructive evaluation techniques (NDE) are capable of detecting sub-surface flaws in composite materials. These include shearography, video image correlation, ultrasonic, acoustic emissions, and X-ray. The difficulty with most of these techniques is that they are time consuming and often difficult to apply to full scale structures. An NDE technique that appears to have the capability to quickly and easily detect flaws in composite structure is thermography. This technique uses heat to detect flaws. Heat is applied to the surface of a structure with the use of a heat lamp or heat gun. A thermographic camera is then pointed at the surface and records the surface temperature as the composite structure cools. Flaws in the material will cause the thermal-mechanical material response to change. Thus, the surface over an area where a flaw is present will cool differently than regions where flaws do not exist. This paper discusses the effort made to thermo-mechanically model the thermography process. First the material properties and physical parameters used in the model will be explained. This will be followed by a detailed discussion of the finite element model used. Finally, the result of the model will be summarized along with recommendations for future work.

Bucinell, Ronald B.↗

CAMIS: A Cylindrical Active Mask Imaging System

Detecting and locating radiological and nuclear materials at distances of 10 m or more in urban and cluttered environments continues to pose challenges in nuclear security and proliferation detection. Previous approaches have focused on large-area radiation imaging using planar configurations of detectors and passive masks. However, these approaches suffer from limitations such as limited field-of-view (FOV) and reduced detection efficiency due to absorption in the mask. To address these limitations, we have developed the cylindrical active mask imaging system (CAMIS). This system comprises 128 NaI(Tl) (10 cm)3 detectors. These detectors are arranged in a cylindrical configuration, enabling gamma-ray imaging with a full 360° azimuthal FOV. The active mask elements within the system are arranged in a pseudorandom configuration, providing unique encoding for all incident directions within the FOV. CAMIS offers an effective detection area of approximately 1 m2 across the entire 360° FOV in the horizontal plane, achieving a mean angular resolution of 10.9° in the azimuthal direction and 12.9° in the polar direction measured by taking the full-width at half-maximum (FWHM) of a cross-section at the maximum reconstructed intensity.

Lamb, C↗

Real-time 3D analysis during electron tomography using tomviz

The demand for high-throughput electron tomography is rapidly increasing in biological and material sciences. However, this 3D imaging technique is computationally bottlenecked by alignment and reconstruction which runs from hours to days. We demonstrate real-time tomography with dynamic 3D tomographic visualization to enable rapid interpretation of specimen structure immediately as data is collected on an electron microscope. Using geometrically complex chiral nanoparticles, we show volumetric interpretation can begin in less than 10 minutes and a high-quality tomogram is available within 30 minutes. Real-time tomography is integrated into tomviz, an open-source and cross-platform 3D data analysis tool that contains intuitive graphical user interfaces (GUI), to enable any scientist to characterize biological and material structure in 3D.

36 MATERIALS SCIENCE↗

The Measurement of Grain Size by Electron Beam Backscattered Diffraction

The method of electron back-scatter diffraction provides an analytic means to identify crystalline phase and the grain size of structural materials. The need to utilize imaging parameters consistent with revealing the contributing microstructural scale is often overlooked through packaged imaging scripts. It is shown that imaging parameters consistent with a post processing assessment of low misorientation angles between boundaries are achievable as using pixel sizes on the order of 10 1 nm.

36 MATERIALS SCIENCE↗

Polaritonic quantum matter

Polaritons are quantum mechanical superpositions of photon states with elementary excitations in molecules and solids. The light–matter admixture causes a characteristic frequency-momentum dispersion shared by all polaritons irrespective of the microscopic nature of material excitations that could entail charge, spin, lattice or orbital effects. Polaritons retain the strong nonlinearities of their matter component and simultaneously inherit ray-like propagation of light. Polaritons prompt new properties, enable new opportunities for spectroscopy/imaging, empower quantum simulations and give rise to new forms of synthetic quantum matter. Here, we review the emergent effects rooted in polaritonic quasiparticles in a wide variety of their physical implementations. We present a broad portfolio of the physical platforms and phenomena of what we term polaritonic quantum matter. We discuss the unifying aspects of polaritons across different platforms and physical implementations and focus on recent developments in: polaritonic imaging, cavity electrodynamics and cavity materials engineering, topology and nonlinearities, as well as quantum polaritonics.

light–matter interaction↗