Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Temperature Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Static Strain Modelling, Calibration, and Measurements for High-Temperature Wireless SAW Resonator Operation

Static strain measurements are relevant for Integrated System Health Monitoring of civil structures, aircrafts, power plants and advanced manufacturing equipment, with implications for safety, process efficiency, and maintenance costs. Wireless strain sensing is highly desirable where the presence of wires poses significant safety concerns, increases maintenance, and thus overall costs, or where they are not feasible, such as in applications which contain moving parts. This paper presents wireless interrogation of surface acoustic wave resonators (SAWRs) fabricated on langasite (LGS) along Euler angles (0°, 138.5°, 32.9°) and aimed at the detection of static strain at hightemperature (HT, above 100°C). Both commercial HT strain gauges and finite element analysis (FEA Abaqus software) were used and compared for SAWR strain calibration from room temperature (RT) to HT. In addition, this work investigated a compromise between high temperature operation vs. sensitivity based on the thickness of ceramic adhesive used. For instance, a reduction in the adhesive thickness from about 150 μm to 135 μm, resulted in a 39% increase in sensitivity at RT. It was also observed that the sensitivity dropped up to 34% from RT to 200°C. Furthermore, wireless operation, calibration, and increase in sensitivity constitute important advances in the use of LGS SAW devices to monitor static stress in high-temperature harsh environments.

42 ENGINEERING↗

Pulse Mode Calibration of the Micro Pocket Fission Detector

The Micro-Pocket Fission Detector (MPFD) is a neutron sensor currently under development in the High Temperature Test Laboratory (HTTL) for use as a supporting instrument during material testing experiments performed at TREAT. The detector has the capability to observe the real-time neutron population while surviving the harsh radiation, and temperature conditions, which sets it apart from most neutron sensitive devices. The next step in the instrument development process is to define a method of calibrating pulse-mode operations. This procedure will allow the detector to be calibrated to allow for absolute measurements of localized neutron population in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design for high-temperature /1800 deg F/ liquid metal pressure transducer

Thermionic diode sensor is used as a pressure transducer in advanced space power systems using liquid metals as working and heat transfer media at temperatures up to 1800 deg F. The sensor converts the motion of a pressure actuated refractory alloy capsule into a suitable electrical output.

Engdahl, R. E.↗

Advances in pyroelectric infrared detectors.

Recent improvements in the pyroelectric detector have been due to the development of locked-in polarization, further reduction of the FET leakage current, and reduction of short circuit noise. The pyroelectric detector has been successfully employed in these typical applications: (1) thermograph using a single detector and X-Y scanner, (2) focal plane reticle scanner, (3) linear array thermal imaging system, (4) pyroelectric image tube, (5) radiometers (vertical temperature profile radiometer, carbon dioxide sensor), (6) high speed spectrometer, and (7) laser detector.

Beerman, H. P.↗

Tracking transient temperatures with liquid crystals

The theoretical basis of the use of the liquid crystal technique to obtain transient thermal data is discussed. Results of calibrations of liquid crystal temperature sensors are given. The effects of crystal aging, lighting effects, observer bias, etc., on accuracy are discussed. The sensitivity of liquid crystal tapes as sensors of dynamic temperature changes is quite high. The accuracy of the technique is determined primarily by the type of calibration apparatus used.

Grodzka, P. G.↗

Self-Correcting Electronically-Scanned Pressure Sensor

High-data-rate sensor automatically corrects for temperature variations. Multichannel, self-correcting pressure sensor can be used in wind tunnels, aircraft, process controllers and automobiles. Offers data rates approaching 100,000 measurements per second with inaccuracies due to temperature shifts held below 0.25 percent (nominal) of full scale over a temperature span of 55 degrees C.

Gross, C.↗

Research instrumentation for hot section components of turbine engines

Programs to develop research instrumentation for use on hot section components of turbine engines are discussed. These programs can be separated into two categories: one category includes instruments which can measure the environment within the combustor and turbine components, the other includes instruments which measure the response of engine components to the imposed environment. Included in the first category are instruments to measure total heat flux and fluctuating gas temperature. High temperature strain measuring systems, thin film sensors (e.g., turbine blade thermocouples) and a system to view the interior of a combustor during engine operation are programs which comprise the second category. The paper will describe the state of development of these sensors and measuring systems and, in some cases, show examples of measurements made with this instrumentation. The discussion will cover work done at NASA Lewis and at various contractor facilities.

Englund, D. R.↗

A Probabilistic System Analysis of Intelligent Propulsion System Technologies

NASA s Intelligent Propulsion System Technology (Propulsion 21) project focuses on developing adaptive technologies that will enable commercial gas turbine engines to produce fewer emissions and less noise while increasing reliability. It features adaptive technologies that have included active tip-clearance control for turbine and compressor, active combustion control, turbine aero-thermal and flow control, and enabling technologies such as sensors which are reliable at high operating temperatures and are minimally intrusive. A probabilistic system analysis is performed to evaluate the impact of these technologies on aircraft CO2 (directly proportional to fuel burn) and LTO (landing and takeoff) NO(x) reductions. A 300-passenger aircraft, with two 396-kN thrust (85,000-pound) engines is chosen for the study. The results show that NASA s Intelligent Propulsion System technologies have the potential to significantly reduce the CO2 and NO(x) emissions. The results are used to support informed decisionmaking on the development of the intelligent propulsion system technology portfolio for CO2 and NO(x) reductions.

Tong, Michael T.↗

Inexpensive Implementation of Many Strain Gauges

It has been proposed to develop arrays of strain gauges as arrays of ordinary metal film resistors and associated electronic readout circuitry on printed circuit boards or other suitable substrates. This proposal is a by-product of a development of instrumentation utilizing metal film resistors on printed-circuit boards to measure temperatures at multiple locations. In the course of that development, it was observed that in addition to being sensitive to temperature, the metal film resistors were also sensitive to strains in the printed-circuit boards to which they were attached. Because of the low cost of ordinary metal film resistors (typically <$0.01 apiece at 2007 prices), the proposal could enable inexpensive implementation of arrays of many (e.g., 100 or more) strain gauges, possibly concentrated in small areas. For example, such an array could be designed for use as a computer keyboard with no moving parts, as a device for sensing the shape of an object resting on a surface, or as a device for measuring strains at many points on a mirror, a fuel tank, an airplane wing, or other large object. Ordinarily, the effect of strain on resistance would be regarded as a nuisance in a temperature-measuring application, and the effect of temperature on resistance would be regarded as a nuisance in a strain-measuring application. The strain-induced changes in resistance of the metal film resistors in question are less than those of films in traditional strain gauges. The main novel aspect of present proposal lies in the use of circuitry affording sufficient sensitivity to measure strain plus means for compensating for the effect of temperature. For an array of metal film resistors used as proposed, the readout circuits would include a high-accuracy analog-to-digital converter fed by a low noise current source, amplifier chain, and an analog multiplexer chain. Corrections would be provided by use of high-accuracy calibration resistors and a temperature sensor. By use of such readout circuitry, it would be possible to read the resistances of as many as 100 fixed resistors in a time interval of 1 second at a resolution much greater than 16 bits. The readout data would be processed, along with temperature calibration data, to deduce the strain on the printed-circuit board or other substrate in the areas around the resistors. It should also be possible to also deduce the temperature from the readings.

Berkun, Andrew C.↗

Design of a Geothermal Downhole Magnetic Flowmeter

This paper covers the development of a 300°C geothermal solid-state magnetic flowmeter (or magmeter) to support in situ monitoring of future EGS (enhanced geothermal system) production wells. Existing flowmeters are simple mechanical spinner sensors. These mechanical sensors fail within as little as 10 hrs, while a solid-state magmeter has the potential for months/years of operation. The design and testing of a magnetic flow sensor for use with existing high-temperature electronics is presented.

EGS, Geothermal Flow, Production Logging, Geotherm↗

Development of GaN-based micro chemical sensor nodes

Sensors based on III-N technology are gaining significant interest due to their potential for monolithic integration of RF transceivers and light sources and the capability of high temperature operations. We are developing a GaN-based micro chemical sensor node for remote detection of chemical toxins, and present electrical responses of AlGaN/GaN HEMT (High Electron Mobility Transistor) sensors to chemical toxins as well as other common gases.

chemical↗

Synergistic smart fuel for microstructure mediated measurements

Advancing the Nuclear Fuel Cycle and Next Generation Nuclear Power Plants requires enhancing our basic understanding of fuel and materials behavior under irradiation. The two most significant issues limiting the effectiveness and lifespan of the fuel are the loss of thermal conductivity of the fuel and the mechanical strength of both fuel and cladding. The core of a nuclear reactor presents an extremely harsh and challenging environment for both sensors and telemetry due to elevated temperatures and large fluxes of energetic and ionizing particles from radioactive decay processes. The majority of measurements are made in reactors using 'radiation hardened' sensors and materials. A different approach has been pursued in this research that exploits high temperatures and materials that are robust with respect to ionizing radiation. This synergistically designed thermoacoustic sensor will be self-powered, wireless, and provide telemetry. The novel sensor will be able to provide reactor process information even if external electrical power and communication are unavailable. In addition, the form-factor for the sensor is identical to the existing fuel rods within reactors and contains no moving parts. Results from initial proof of concept experiments designed to characterize porosity, surface properties and monitor gas composition will be discussed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Synergistic Smart Fuel For Microstructure Mediated Measurements

Advancing the Nuclear Fuel Cycle and Next Generation Nuclear Power Plants requires enhancing our basic understanding of fuel and materials behavior under irradiation. The two most significant issues limiting the effectiveness and lifespan of the fuel are the loss of thermal conductivity of the fuel and the mechanical strength of both fuel and cladding. The core of a nuclear reactor presents an extremely harsh and challenging environment for both sensors and telemetry due to elevated temperatures and large fluxes of energetic and ionizing particles from radioactive decay processes. The majority of measurements are made in reactors using “radiation hardened” sensors and materials. A different approach has been pursued in this research that exploits high temperatures and materials that are robust with respect to ionizing radiation. This synergistically designed thermoacoustic sensor will be self-powered, wireless, and provide telemetry. The novel sensor will be able to provide reactor process information even if external electrical power and communication are unavailable. In addition, the form-factor for the sensor is identical to the existing fuel rods within reactors and contains no moving parts. Results from initial proof of concept experiments designed to characterize porosity, surface properties and monitor gas composition will be discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of the MODIS "Clear-Sky" Surface Temperature of the Greenland Ice Sheet

Surface temperatures on the Greenland Ice Sheet have been studied on the ground, using automatic weather station (AWS) data from the Greenland-Climate Network (GC-Net), and from analysis of satellite sensor data. Using Advanced Very High Frequency Radiometer (AVHRR) weekly surface temperature maps, warming of the surface of the Greenland Ice Sheet has been documented from 1981 to present. We extend and refine this record using higher-resolution Moderate-Resolution Imaging Spectroradiometer (MODIS) data from March 2000 to the present. To permit changes to be observed over time, we are developing a well-characterized monthly climate-data record (CDR) of the "clear-sky" surface temperature of the Greenland Ice Sheet using data from both the Terra and Aqua satellites. We use the MODIS ice-surface temperature (IST) algorithm. Validation of the CDR consists of several facets: 1) comparisons between the Terra and Aqua IST maps; 2) comparisons between ISTs and in-situ measurements; 3) comparisons between ISTs and AWS data; and 4) comparisons of ISTs with surface temperatures derived from other satellite instruments such as the Thermal Emission and Reflection Radiometer. In this work, we focus on 1) and 2) above. Surface temperatures on the Greenland Ice Sheet have been studied on the ground, using automatic weather station (AWS) data from the Greenland-Climate Network (GC-Net), and from analysis of satellite sensor data. Using Advanced Very High Frequency Radiometer (AVHRR) weekly surface temperature maps, warming of the surface of the Greenland Ice Sheet has been documented from 1981 to present. We extend and refine this record using higher-resolution Moderate-Resolution Imaging Spectroradiometer (MODIS) data from March 2000 to the present. To permit changes to be observed over time, we are developing a well-characterized monthly climate-data record (CDR) of the "clear-sky" surface temperature of the Greenland Ice Sheet using data from both the Terra and Aqua satellites. We use the MODIS ice-surface temperature (IST) algorithm. Validation of the CDR consists of several facets: 1) comparisons between the Terra and Aqua IST maps; 2) comparisons between ISTs and in-situ measurements; 3) comparisons between ISTs and AWS data; and 4) comparisons of ISTs with surface temperatures derived from other satellite instruments such as the Thermal Emission and Reflection Radiometer. In this work, we focus on 1) and 2) above. First we provide comparisons between Terra and Aqua swath-based ISTs at approximately 14:00 Local Solar Time, reprojected to 12.5 km polar stereographic cells. Results show good correspondence when Terra and Aqua data were acquired within 2 hrs of each other. For example, for a cell centered over Summit Camp (72.58 N, 38.5 W), the average agreement between Terra and Aqua ISTs is 0.74 K (February 2003), 0.47 K (April 2003), 0.7 K (August 2003) and 0.96 K (October 2003) with the Terra ISTs being generally lower than the Aqua ISTs. More precise comparisons will be calculated using pixel data at the swath level, and correspondence between Terra and Aqua IST is expected to be closer. (Because of cloud cover and other considerations, only a few common cloud-free swaths are typically available for each month for comparison.) Additionally, previous work comparing land-surface temperatures (LSTs) from the standard MODIS LST product and in-situ surface-temperature data at Summit Camp on the Greenland Ice Sheet show that Terra MODIS LSTs are about 3 K lower than in-situ temperatures at Summit Camp, during the winter of 2008-09. This work will be repeated using both Terra and Aqua IST pixel data (in place of LST data). In conclusion, we demonstrate that the uncertainties in the CDR will be well characterized as we work through the various facets of its validation.

Hall, Dorothy K.↗

Analysis of temperature effects on self-powered neutron detectors in a gamma field

Self-powered neutron detectors (SPND) are small, robust, in-core radiation sensors that have the potential to operate in high temperature environments (above 600°C). However, previous experiments indicated temperature related effects in the form of displacement currents. Given the recent irradiation at The Ohio State University Research Reactor using a delayed-response rhodium-based SPND alongside a prompt-response tantalum-based SPND, it was concluded that only low-energy electrons from gamma interactions were the cause of these temperature effects. A series of heated gamma irradiations with temperatures up to 750°C of SPNDs were performed at the Advanced Test Reactor Gamma Facility in order to better characterize these displacement currents. The results from the experiments demonstrated a strong relation between the displacement currents that occurred during temperature ramps to thermoluminescence (TL) glow peaks—the SPND with Al2O3 insulation has one glow peak within 750°C and the SPND with MgO has three. A demonstration was performed to calculate the trap energy levels of the displacement currents through TL glow peak analysis. Unfortunately, the methods employed provided inconsistent results, requiring an updated model based on ongoing irradiation instead of post-irradiation measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Fibre optic extensometer for high radiation and high temperature nuclear applications

In the framework of the Joint Instrumentation Laboratory (LCI), gathering resources from SCK-CEN (Belgium) and CEA (France), we are developing an optical sensor in order to accurately measure radiation-induced elongation of material placed in the core of a Material Testing Reactor (MTR). This extensometer displays common advantages of Fibre Optic (FO) sensors: high resolution, easy remote sensing and multiplexing, and also compact size which is of particular interest for in pile experiments with little room available. In addition, light weight reduces gamma heating hence limiting the thermal effect. In accordance with the specifications, the sensor has preferably two fixing points defining a gauge length of 10 to 15 mm (as a minimum). The diameter is less than 2 mm. Intense gamma and neutron irradiation as well as high temperatures are the most difficult environment conditions to withstand. Reactor radiation produces huge losses in common optical fibre. The losses can be limited by selecting the fibres (mainly with high purity silica core), the wavelength range (800-1200 nm), and a measurement based on interferometry (largely insensitive to losses in the fibre thanks to the wavelength encoding of the useful signal). Heavy neutron - mainly - and gamma flux such as in MTR, also produce compaction of silica, resulting in a significant drift and preventing the use of commercial FO sensors in such environment. Knowing this issue we revised the basic scheme of Extrinsic Fabry Perot Interferometer (EFPI) in order to limit the effects of compaction. A first sensor prototype fixed on a stainless steel support was tested in the Smirnof test facility in the BR2 MTR in Mol (Belgium). The support was subject to a constant mechanical and thermal stress, and his dimensions were not supposed to vary. This test showed a very low drift of the revisited EPFI design under high irradiation field in comparison with a commercial EFPI. This result has to be confirmed with second generation sensors with an increased robustness. The other difficulty to face is high temperature. Fibre optics with metal coating allows safe operation under temperatures up to 400 deg.C and even higher. But differential dilatation between silica and typical metallic material produces differential elongation in the range of 0.5 10{sup -2} i.e 5000{mu}{epsilon} for an increase in temperature of 300-400 deg. C. Such large elongation has to be considered carefully in the sensor design and its fixing on the sample. Laboratory tests with a second generation of adapted sensors demonstrated their good accuracy: less than 1% error over a displacement of 100{mu}m (< 1 {mu}m error), at room temperature. The displacement measured can reach 250{mu}m (20000{mu}{epsilon} with a gauge length of 12.5 mm) or more. We are currently implementing metal-coated fibre and we are preparing the next in pile irradiation on the BR2 reactor scheduled for mid-2011. Other applications of the sensor can be considered. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗