Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position Sensitive Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload

The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (<0.25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter. The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and then detecting the de-excitation X-rays and the nuclear annihilation products. This measurement is realized using a Tracker composed of more than 1000 custom silicon strip detectors and a plastic scintillator time-of-flight (TOF) system instrumenting more than 40m$^2$. Together, these subsystems provide the velocity and energy resolution, stopping power, particle tracking, and X-ray identification necessary to distinguish rare antinucleus signals from the abundant positive-nucleus backgrounds, all within the constraints of a high-altitude mission. A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system. The first GAPS science payload flew for 25 days during the 2025/26 NASA Antarctic balloon campaign. We detail the design, integration, and commissioning of the payload prior to flight.

Aoyama, Kazutaka [JAXA, Sagamihara]↗

Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control

Purpose: Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. Methods and Materials: A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. Results: There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. Conclusions: SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-A-9A-11: Gold Nanoparticles Enhanced Diffuse Optical Tomography: A Proof of Concept Study

Purpose: To investigate the feasibility and potential of gold nanoparticles (GNP) enhanced diffuse optical tomography (DOT) as a novel imaging strategy for tumor detection. Methods: Simulation was performed on a digital homogeneous cylindrical phantom of 30mm×30mm. Gold nanorods (GNR) with aspect ratio 3.9 and effective radius 21.86nm were used as contrast agent. The peak light absorption for these GNR occurs at 842nm within the near-infrared region, with the absorption cross-section of 1.97×10{sup -14}m{sup -2} and scatter cross-section of 1.07×10{sup -14}m{sup -2}. A 6mmdiameter sphere of GNR solution was positioned inside the tissue-simulating phantom. Simulations were performed at the GNR concentration level of 1nM, 100pM and 10pM, respectively. The points representing laser sources and light detectors were around the phantom with 30o apart tangentially and 1mm apart axially for 9 rows. As one point being source, all the other points within the current row and nearby four rows become detectors. Hence there are 108 source points in total and 55 detector points corresponding to each source. Forward light transport at 842nm wavelength was run on a three-dimensional mesh of 33186 nodes (∼0.5mm resolution) to acquire the light emission data. Reconstruction was performed on a coarse mesh of 19408 nodes (∼1mm resolution) with ∼20minutes on a 2.4GHz CPU and 8GB RAM computer. Results: The position of the GNR solution at 1nM, 100pM and 10pM concentration was reconstructed, respectively, with <1mm error. The GNR concentration was interpreted from the reconstructed absorption coefficient within the enhanced volume. The reconstructed maximum concentrations were 0.3nM, 120.0pM, and 5.3pM, respectively. Conclusion: To the best of our knowledge, this is the first time to apply GNP to enhance DOT. The simulation results showed the high sensitivity of GNP enhanced DOT, which is in pM concentration level, compared to the μM level for MRI agents and nM level for PET agents.

60 APPLIED LIFE SCIENCES↗

Mapping valence electron distributions with multipole density formalism using 4D-STEM

Recent advancement in aberration correction and detector technology opened a door to various applications using 4D-STEM, which yields a diffraction pattern for each scanning position within a crystal unit-cell in scanning transmission electron microscopy (STEM) and generates incredible amounts of data in momentum space. Currently 4D-STEM analysis relies on the center-of-mass of the diffraction patterns in electric field and charge density mapping. It only derives the total projected charge density and is limited to phase objects, e.g. extremely thin samples. Here, we propose a new analytical method to accurately map aspherical valence electron distributions with atom-centered multipolar functions formalism using the whole 4D-STEM dataset. We demonstrate that, with the full dynamical calculations for various sample thicknesses, the method is sensitive not only to the miniscule charge transfer, but also to the atomic site symmetry and aspherical electron orbitals. The process of the refinement is much more robust and reliable than quantitative convergent beam electron diffraction.

4D-STEM↗

Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding

Purpose: The aim of this study was to develop a prototype PET detector module for a combined small animal positron emission tomography and magnetic resonance imaging (PET/MRI) system. The most important factor for small animal imaging applications is the detection sensitivity of the PET camera, which can be optimized by utilizing longer scintillation crystals. At the same time, small animal PET systems must yield a high spatial resolution. The measured object is very close to the PET detector because the bore diameter of a high field animal MR scanner is limited. When used in combination with long scintillation crystals, these small-bore PET systems generate parallax errors that ultimately lead to a decreased spatial resolution. Thus, we developed a depth of interaction (DoI) encoding PET detector module that has a uniform spatial resolution across the whole field of view (FOV), high detection sensitivity, compactness, and insensitivity to magnetic fields. Methods: The approach was based on Geiger mode avalanche photodiode (G-APD) detectors with cross-strip encoding. The number of readout channels was reduced by a factor of 36 for the chosen block elements. Two 12 × 2 G-APD strip arrays (25μm cells) were placed perpendicular on each face of a 12 × 12 lutetium oxyorthosilicate crystal block with a crystal size of 1.55 × 1.55 × 20 mm. The strip arrays were multiplexed into two channels and used to calculate the x, y coordinates for each array and the deposited energy. The DoI was measured in step sizes of 1.8 mm by a collimated {sup 18}F source. The coincident resolved time (CRT) was analyzed at all DoI positions by acquiring the waveform for each event and applying a digital leading edge discriminator. Results: All 144 crystals were well resolved in the crystal flood map. The average full width half maximum (FWHM) energy resolution of the detector was 12.8% ± 1.5% with a FWHM CRT of 1.14 ± 0.02 ns. The average FWHM DoI resolution over 12 crystals was 2.90 ± 0.15 mm. Conclusions: The novel DoI PET detector, which is based on strip G-APD arrays, yielded a DoI resolution of 2.9 mm and excellent timing and energy resolution. Its high multiplexing factor reduces the number of electronic channels. Thus, this cross-strip approach enables low-cost, high-performance PET detectors for dedicated small animal PET and PET/MRI and potentially clinical PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPECTRAL ANALYSIS OF RADIOXENON

Monitoring changes in atmospheric radioxenon concentrations is a major tool in the detection of an underground nuclear explosion. Ground based systems like the Automated Radioxenon Sampler /Analyzer (ARSA), the Swedish Unattended Noble gas Analyzer (SAUNA) and the Automatic portable radiometer of isotopes Xe (ARIX), can collect and detect several radioxenon isotopes by processing and transferring samples into a high efficiency beta-gamma coincidence detector. The high efficiency beta-gamma coincidence detector makes these systems highly sensitive to the radioxenon isotopes 133Xe, 131mXe, 133mXe and 135Xe. The standard analysis uses regions of interest (ROI) to determine the amount of a particular radioxenon isotope present. The ROI method relies on the peaks of interest falling within energy limits of the ROI. Some potential problems inherent in this method are the reliance on stable detector gains and a fixed resolution for each energy peak. In addition, when a high activity sample is measured there will be more interference among the ROI, in particular within the 133Xe, 133mXe, and 131mXe regions. A solution to some of these problems can be obtained through spectral fitting of the data. Spectral fitting is simply the fitting of the peaks using known functions to determine the number and relative peak positions and widths. By knowing this information it is possible to determine which isotopes are present. Area under each peak can then be used to determine an overall concentration for each isotope. Using the areas of the peaks several key detector characteristics can be determined: efficiency, energy calibration, energy resolution and ratios between interfering isotopes (Radon daughters).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Quantum Enhanced Tracker (Final Report)

A new concept of charged particle detector, called Quantum Enhanced Tracker (QET) is proposed and intended for optical imaging of charged particle tracks. We present a quantum-based detection method for reconstructing the spatial profile of an electron beam by passing it through a dilute vapor of rubidium atoms. The perturbation of the atomic spin’s quantum state by the electron beam’s magnetic field is detected via nonlinear magneto-optical polarization rotation. Consequently, the electron beam’s position, size and current density can be measured, and its transverse profile reconstructed by analyzing the polarization rotation of a transverse probe laser. This method was experimentally studied using e-beams with currents ranging from 1 to 200 μA and energies between 10 to 20 keV. The results show that this approach is sensitive to the e-beam current and independent of e-beam energy. This technique provides a potentially 3-D capable approach for non-invasive characterization and monitoring of charged particles used in accelerators and nuclear physics research.

43 PARTICLE ACCELERATORS↗

Harnessing the Quantum Zeno Effect in superconducting qubits for particle detection

Superconducting qubits, originally developed for quantum computing, are emerging as a potentially powerful tool for detecting low-energy particle interactions, such as dark matter and neutrinos. These devices can register energy deposits as small as a few meV, dramatically lowering the detection threshold compared to conventional sensors. However, their deployment in rare-event searches is hampered by a critical and unresolved background: Two-Level Systems (TLSes). TLSes are material defects that can scramble qubit frequencies and coherence times in a way that resembles particle energy deposits. Such false signals can critically limit the sensitivity and extend experimental runtimes for qubit-based sensors by years. This talk introduces a novel method to eliminate TLSes as a background source in superconducting qubit-based detectors. By harnessing the Quantum Zeno Effect (QZE), a well-established quantum phenomenon where frequent observation inhibits system evolution, I will discuss the possibility of “freezing” these TLS defects in place. This effectively suppresses their interference, stabilizes qubit behavior, and opens the door to using TLSes themselves as auxiliary sensors. I have already identified target TLSes and observed early signs of QZE-like dynamics in Fermilab-fabricated devices. The method builds on my existing collaborations at Fermilab’s Quantum Information Testbed (QUIET), with access to low muon flux cryogenic facilities 100 meters underground, control electronics, and expert mentors across multiple institutions. By removing a key bottleneck to superconducting sensor deployment, this research targets advancing the development of a general-purpose technique to enhance sensitivity, reduce false positives, and accelerate discovery in searches for dark matter, neutrinos, and other rare phenomena.

Seidel, Olivia [Texas U., Arlington]↗

Complementarity between direct and indirect searches of Dark Matter and the ILC

We study the possibility of identifying dark matter properties from XENON-like 100 kg experiments and the GLAST satellite mission. We show that whereas direct detection experiments will probe efficiently light WIMPs, given a positive detection (at the 10% level for m{sub {chi}} < or approx. 50 GeV), GLAST will be able to confirm and even increase the precision in the case of a NFW profile, for a WIMP-nucleon cross-section {sigma}{sub {chi}}{sub -p} < or approx. 10{sup -8} pb. We also predict the production rate of a WIMP in the next generation of colliders (ILC), and compare their sensitivity to the WIMP mass with the XENON and GLAST projects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray tomography of extended objects: a comparison of data acquisition approaches

The penetration power of x-rays allows one to image large objects while their short wavelength allows for high spatial resolution. As a result, with synchrotron sources one has the potential to obtain tomographic images of centimeter-sized specimens with sub-micrometer pixel sizes. However, limitations on beam and detector size make it difficult to acquire such data of this sort in a single take, necessitating strategies for combining data from multiple regions. One strategy is to acquire a tiled set of local tomograms by rotating the specimen around each of the local tomogram center positions. Another strategy, sinogram oriented acquisition, involves the collection of projections at multiple offset positions from the rotation axis followed by data merging and reconstruction. We have carried out a simulation study to compare these two approaches in terms of radiation dose applied to the specimen, and reconstructed image quality. Local tomography acquisition involves an easier data alignment problem, and immediate viewing of subregions before the entire dataset has been acquired. Sinogram oriented acquisition involves a more difficult data assembly and alignment procedure, and it is more sensitive to accumulative registration error. Furthermore, sinogram oriented acquisition is more dose-efficient, it involves fewer translation motions of the object, and it avoids certain artifacts of local tomography.

47 OTHER INSTRUMENTATION↗

Consumption study and identification of methyl salicylate in spicy cassava chips

Spicy cassava chips is a popular snack. However, some news in electronic media reported addition of balsam which is a banned food additives in that product to give extra spicy flavor. This study aimed to determine ITB students’ pattern of consumption, health problems caused by spicy chips consumption, and knowledge about illicit use of food additives in that product, and identify the main content of balsam namely methyl salicylate in 10 samples of spicy cassava chips taken from inside and outside about ITB campus. A total of 300 questionnaires distributed to ITB students then data processing was performed. Spicy cassava chips sample macerated in 50 mL of methanol for 24 hours at room temperature, filtered and analyzed using gas chromatography capillary column with OV-1, nitrogen carrier gas and flame ionization detector. Based on questionnaires, 292 (97%) of 300 respondents had consumed spicy chips. A total of 247 (85%) from 292 respondents spicy chips consumed less than 3 times a week. A total of 195 respondents (67%) had experienced health problems after eating spicy chips. There were 137 (47%) of the 292 respondents who knew about the illicit addition of food additives into spicy chips; only 35 respondents (12%) who knew about balsam’s addition. There were 126 respondents (43%) who did not pay attention to their health because they will keep eating spicy chips despite the addition of banned food additives. Through the verification of the standard addition method in gas chromatography system with a hydrogen pressure of 1.5 bar, injector temperature 200 °C, detector temperature 230 °C, oven temperature 60 °C for 2 minutes and then increased to 230 °C with rate 6 °C/menit; linearity, limit of detection, limit of quantitation, accuracy, precision, and specificity parameters met the acceptance limits. From 10 spicy cassava chips samples which were analyzed, they did not reveal any content of methyl salicylate. Methyl salicylate contained in the positive control was 1.273 mg/mL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observing the next galactic supernova

No supernova (SN) in the Milky Way has been observed since the invention of the optical telescope, instruments for other wavelengths, neutrino detectors, or gravitational wave observatories. It would be a tragedy to miss the opportunity to fully characterize the next one. To aid preparations for its observations, we model the distance, extinction, and magnitude probability distributions of a successful Galactic core-collapse supernova (ccSN), its shock breakout radiation, and its massive star progenitor. We find, at very high probability (≅ 100%), that the next Galactic SN will easily be detectable in the near-IR and that near-IR photometry of the progenitor star very likely (≅ 92%) already exists in the Two Micron All Sky Survey. Most ccSNe (98%) will be easily observed in the optical, but a significant fraction (43%) will lack observations of the progenitor due to a combination of survey sensitivity and confusion. If neutrino detection experiments can quickly disseminate a likely position (∼3°), we show that a modestly priced IR camera system can probably detect the shock breakout radiation pulse even in daytime (64% for the cheapest design). Neutrino experiments should seriously consider adding such systems, both for their scientific return and as an added and internal layer of protection against false triggers. We find that shock breakouts from failed ccSNe of red supergiants may be more observable than those of successful SNe due to their lower radiation temperatures. We review the process by which neutrinos from a Galactic ccSN would be detected and announced. We provide new information on the EGADS system and its potential for providing instant neutrino alerts. We also discuss the distance, extinction, and magnitude probability distributions for the next Galactic Type Ia supernova (SN Ia). Based on our modeled observability, we find a Galactic ccSN rate of 3.2{sub −2.6}{sup +7.3} per century and a Galactic SN Ia rate of 1.4{sub −0.8}{sup +1.4} per century for a total Galactic SN rate of 4.6{sub −2.7}{sup +7.4} per century is needed to account for the SNe observed over the last millennium, which implies a Galactic star formation rate of 3.6{sub −3.0}{sup +8.3} M {sub ☉} yr{sup –1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of signal diffusion on x-ray phase contrast images

We discuss the problem of signal diffusion among neighbouring pixels in x-ray phase contrast imaging (XPCi) specifically for coded-aperture (CA) XPCi, but many of the discussed observations are directly transferable to other XPCi modalities. CA XPCi exploits the principle of pixel edge illumination by means of two CA masks. The first mask, placed in contact with the detector, creates insensitive regions between adjacent pixels; the second one, placed immediately before the sample, creates individual beams impinging on the boundaries between sensitive and insensitive regions on the detector, as created by the detector mask. In this way, edge illumination is achieved for all pixels of an area detector illuminated by a divergent and polychromatic beam generated by a conventional source. As the detector mask redefines the resolution properties of the detector, sample dithering can be used to effectively increase the system spatial resolution, without having to apply any post-processing procedure (e.g., deconvolution). This however creates artifacts in the form of secondary fringes (which have nothing to do with phase-related secondary fringes) if there is signal diffusion between adjacent pixels. In non-dithered images, signal diffusion between adjacent pixels causes a reduction in image contrast. This effect is investigated both theoretically and experimentally, and its direct implications on image quality are discussed. The interplay with the sample positioning with respect to the detector pixel matrix, which also has an effect on the obtained image contrast, is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Deployable Fast-Neutron Coded-Aperture Imager: Demonstration of Locating One or More Sources in Three Dimensions

This brief report describes commissioning measurements performed using a newly constructed fast neutron coded-aperture imager intended for performing quantitative measurements of plutonium holdup at fuel cycle facilities. The present report was prepared in fulfillment of milestone M3FT-13OR0402054, “Imager commissioning and 3D source configuration measurements” of Fuel Cycle R&D Material Protection, Accounting, and Control Technology (MPACT) work package FT-13OR040205, “Fast Neutron Imaging to Quantify Nuclear Materials - ORNL.” In addition to representing the first measurements made with the new device, these measurements also demonstrate for the first time the ability to localize one or more neutron sources in three dimensions by combining imaging data from multiple measurements in which the imager was positioned at different locations. The development and use of fast-neutron imaging technology are motivated by a desire to locate and quantify plutonium holdup in scenarios where contact measurements with non-imaging detectors may be impractical or their results ambiguous because of surrounding material or nearby sources. Considering the goal of quantitative measurements, fast neutrons (as opposed to the more numerous gamma rays) are preferred in many situations because of their ability to penetrate equipment and nuclear material that are essentially opaque to gamma radiation. However, there are many challenges associated with constructing a practical imager for fast neutrons. For example, the ability of fast neutrons to penetrate material also leads to challenges in constructing a fast-neutron imager that is sufficiently compact to be suitable for use in a facility while remaining sufficiently sensitive to neutron emanations from plutonium or other actinides. Moreover, use of the imager in a production environment favors mechanically robust detectors that do not contain flammable liquid, unlike the organic liquid scintillators that are typically used to achieve fast-neutron detection. Last of all, a single-sided measurement geometry, as is typically used in imaging applications, necessitates accurate measurement of the location of a deposit of plutonium holdup in three dimensions in order to correctly infer the source strength. In response to these challenges, Oak Ridge National Laboratory (ORNL) has built a fast-neutron imager that has a compact footprint and whose segmented neutron detectors are built from the first cast plate of the recently developed plastic scintillator with pulse shape discrimination properties developed by Lawrence Livermore National Laboratory and commercially available from Eljen Technologies as experimental scintillator EJ-299-34. This report presents a description and preliminary analysis of mock holdup measurements intended to determine the three-dimensional location of one or more neutron sources placed in prototypical equipment from a set of imaging measurements that scanned the extent of the equipment.

Hausladen, Paul↗

Imaging system for cardiac planar imaging using a dedicated dual-head gamma camera

A cardiac imaging system employing dual gamma imaging heads co-registered with one another to provide two dynamic simultaneous views of the heart sector of a patient torso. A first gamma imaging head is positioned in a first orientation with respect to the heart sector and a second gamma imaging head is positioned in a second orientation with respect to the heart sector. An adjustment arrangement is capable of adjusting the distance between the separate imaging heads and the angle between the heads. With the angle between the imaging heads set to 180 degrees and operating in a range of 140-159 keV and at a rate of up to 500kHz, the imaging heads are co-registered to produce simultaneous dynamic recording of two stereotactic views of the heart. The use of co-registered imaging heads maximizes the uniformity of detection sensitivity of blood flow in and around the heart over the whole heart volume and minimizes radiation absorption effects. A normalization/image fusion technique is implemented pixel-by-corresponding pixel to increase signal for any cardiac region viewed in two images obtained from the two opposed detector heads for the same time bin. The imaging system is capable of producing enhanced first pass studies, bloodpool studies including planar, gated and non-gated EKG studies, planar EKG perfusion studies, and planar hot spot imaging.

47 OTHER INSTRUMENTATION↗

Maximum Likelihood Source Localization Using Elpasolite as a Dual Gamma Neutron Directional Detector

The problem of accurately detecting extremely low levels of nuclear radiation is rapidly increasing in importance in nuclear counter-proliferation, verification, and environmental and waste management. Because the 239Pu gamma signature may be weak, for instance, even when compared to the natural terrestrial background, coincidence counting with the 239Pu neutron signature may improve overall 239Pu detection sensitivity. However, systems with sufficient multiple-particle detectors require demonstration that the increased sensitivity be sufficiently high to overcome added cost and weight. We report the results of measurements and calculations to determine sensitivity that can be gained in detecting low levels of nuclear radiation from use of a relatively new detector technology based on elpasolite crystals. We have performed investigations exploring cerium (Ce3+)-doped elpasolites Cs2LiYCl6:Ce3+0.5% (CLYC) and Cs2LiLa(Br6)90%(Cl6)10%:Ce3+0.5% (CLLBC:Ce). These materials can provide energy resolution (r(E) = 2.35σ(E)/E) as good as 2.9% at 662 keV (FWHM). The crystals show an excellent neutron and gamma radiation response. The goals of the investigation were to set up the neutron/gamma pulse shape discrimination electronics for elpasolite detectors; perform limited static source benchmarking, testing, and evaluation to validate system performance; and explore application of a maximum likelihood algorithm for source location. Data were measured and processed through a maximum likelihood estimation algorithm, providing a direction to the radioactive source for each individual position. The estimated directions were good representations for the actual directions to the radioactive source. This paper summarizes the maximum likelihood results for our elpasolite system.

maximum likelihood, radiation detectors, neutron d↗

The TAIGA Experiment: From Cosmic Ray Physics to Gamma Astronomy in the Tunka Valley

The article presents the relevance and advantages of the new gamma observatory TAIGA (Tunka Advanced Instrument for cosmic ray physics and Gamma Astronomy), which is being constructed in the Tunka Valley 50 km from Lake Baikal. Various detectors of the six TAIGA gamma observatory arrays register the Cherenkov and radio radiation, as well as the electron and muon components of EAS. The primary objective of the TAIGA gamma observatory is to study the high-energy part of the gamma-ray spectrum, in particular, in order to search for Galactic PeVatrons. The energy, direction, and position of the EAS axis are reconstructed in the observatory based on the data of the wide-angle Cherenkov detectors of the TAIGA-HiSCORE experiment. Taking into account this information, the gamma quanta are distinguished from the hadron background using the data obtained by the muon detectors and telescopes that register the EAS image in the Cherenkov light. In this hybrid mode of operation, the atmospheric Cherenkov telescopes can operate in the mono-mode, and the distance between them can be increased to 800–1000 m, which makes it possible to construct an array with an area of 5 km{sup 2} and more at relatively low cost and in a short time. By 2019, the first stage of the gamma observatory with an area of 1 km{sup 2} will be constructed; its expected integral sensitivity for detecting the gamma radiation with an energy of 100 TeV at observation of the source for 300 hours will be approximately 2×5 10{sup –13} TeV cm{sup –2}s{sup –1}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗