Scenario Generation for Built Environment Decision Support under Uncertainty: Case Studies of Airflow Modeling and Climate-Resilient Infrastructure System Design

When confronted with unforeseen challenges, practicing informed decision making is crucial for enhancing resilience in the built environment. While scan-to-building information modeling (BIM) is a well-established approach for creating detailed digital representations of physical assets, its application in assessing and improving infrastructure resilience remains underexplored. This study addresses this gap by proposing a novel application of scan-to-BIM, namely, scan-to-BIM-to-digital twin (S-BIM-DT) workflow. By integrating reality capture and digital twin technologies, this workflow creates continuously updated and accurate digital representations of physical assets, enabling the generation of various scenarios. Unlike traditional methods, the S BIM-DT workflow facilitates continuous model refinement, supporting informed resilience strategies. By combining these technologies into a cohesive process, the workflow facilitates decision making under uncertainty, enabling stakeholders to evaluate and respond to various scenarios effectively. We demonstrate the implementation of the S-BIM-DT workflow through two use cases that highlight its capability to enhance resilience at different scales. The first use case involves the Combined Transportation, Emergency, and Communications Center (CTECC) in Austin, Texas. BIM-enriched computational fluid dynamics (CFD) modeling simulates airflow and develops alternative scenarios for optimizing the heating, ventilation, and air conditioning (HVAC) systems. This approach enhances resilience against airborne health threats in a postCOVID context. The second use case focuses on designated areas within Beaumont, Texas, as part of the Southeast Texas Urban Integrated Field Laboratory (SETx-UIFL) research. By developing inundation maps to assess extreme weather events, this modeling aids in preparedness efforts and informs the development of climate-resilient infrastructure in vulnerable neighborhoods. Results indicate that the S-BIM-DT workflow effectively generates scenarios that enhance resilience in the built environment by facilitating informed decision making. Furthermore, this study serves as a bridge between advanced scan-to-BIM methodologies and the practical strategies needed to improve built infrastructure resilience.

Built environment↗

Human-in-the-loop Sensing and Control for Commercial Building Energy Efficiency and Occupant Comfort

Most of the existing heating, ventilation and air conditioning (HVAC) systems in commercial buildings operate in a conservative manner by assuming maximum occupancy in each room during pre-specified periods of the week, leading to significant energy being wasted as rooms are over-conditioned compared to the actual requirements of the occupants. Though critical, our understanding of occupancy patterns and thermal comfort needs of the occupants in commercial buildings is lacking and it is well known that both of these quantities are stochastic and time-varying, thus requiring sensing solutions to estimate them. This project had the goal of designing, implementing and evaluating a hardware and software solution to ameliorate this challenge. In particular, a depth camera (one whose pixels reveal distance from the camera as opposed to color values) placed on doorways is used to detect entrance and exit events from thermal zones in the building, and thereby estimate their occupancy levels. This information is then fed to a novel control algorithm that can, through interactions with the HVAC system, learn how to provide control inputs that maximize comfort and minimize energy waste. The resulting system represents a significant improvement over existing controllers for commercial HVAC systems and allowed us to improve our understanding of the design of future human-in-the-loop control solutions. For this solution to be feasible, the project had target metrics for its performance and cost. In particular, entrance and exit events for occupants moving about the building would need to be detected with an accuracy higher than 97%; and the resulting control inputs derived from this information would need to lead to approximately 10% energy savings compared to a schedule-based controller. Furthermore, regarding the final hardware design, the project had a target bill of materials (BOM) cost for the sensing solution of less than US$200 per unit while using less than 25W of power on average. All of these target metrics were met or exceeded by our final proposed solution. We performed evaluations by deploying the system in over 20 rooms of different types across 6 commercial buildings in Pittsburgh, PA over the course of three years, and performing targeted controlled experiments to test its performance along the different metrics. The human-in-the-loop control solutions (both hardware and software) developed through this project are expected to lead to significant improvements in the comfort and energy efficiency of HVAC systems used in commercial buildings. The insights we developed through the project pave the way to HVAC systems that can condition interior spaces according to their real-time utilization and the thermal comfort needs of the occupants, thereby reducing energy use. They also open up a new learning-based way of configuring HVAC controllers without having to manually fine-tune them for each building. These innovations can significantly increase the adoption of novel control solutions by the industry and thereby save resources and reduce costs of operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design Optimization of A-Type Heat Exchangers based on High Performance, Non-Round Tubes

Air-to-refrigerant heat exchangers (HXs) have been the topic of considerable research as they are the fundamental heat transfer components of HVAC&R systems. For residential and commercial applications, indoor heat exchangers are often in A-type configurations to reduce air-conditioner system footprint while still delivering the required cooling or heating. Classical HX design practices typically assume a uniform frontal air velocity profile to facilitate the use of conventional tube-fin airside heat transfer and pressure drop correlations for performance prediction. However, it is well-reported throughout the literature that A-type HXs experience significant airflow maldistribution which can severely degrade HX performance. Additionally, recent advancements in simulation software such as Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA) and optimization algorithms have led researchers to consider primary heat transfer surface optimization to achieve highly compact HXs which do not require fins. In this paper, an A-type HX which utilizes shape-optimized non-round tubes is optimized for minimum duct size and airside pressure drop. This is achieved through coupling of an experimentally validated finite volume HX model with automated 2D CFD simulations of airflow through the HX for airside thermal-hydraulic performance evaluation. Preliminary results show that the optimal designs deliver similar capacity while achieving 20% reductions in airside pressure drop and duct cross-section area. Additionally, the optimal design apex angles in this study were similar to those from previous A-Type HX optimization studies for conventional tube-fin HX geometries, suggesting that the apex angle for optimal A-Type configuration performance may be independent of tube geometry.

42 ENGINEERING↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

An overview of data tools for representing and managing building information and performance data

Building information modeling (BIM) has been widely adopted for representing and exchanging building data across disciplines during building design and construction. However, BIM's use in the building operation phase is limited. With the increasing deployment of low-cost sensors and meters, as well as affordable digital storage and computing technologies, growing volumes of data have been collected from buildings, their energy services systems, and occupants. Such data are crucial to help decision makers understand what, how, and when energy is consumed in buildings—a critical step to improving building performance for energy efficiency, demand flexibility, and resilience. However, practical analyses and use of the collected data are very limited due to various reasons, including poor data quality, ad-hoc representation of data, and lack of data science skills. To unlock value from building data, there is a strong need for a toolchain to curate and represent building information and performance data in common standardized terminologies and schemas, to enable interoperability between tools and applications. This study selected and reviewed 24 data tools based on common use cases of data across the building life cycle, from design to construction, commissioning, operation, and retrofits. The selected data tools are grouped into three categories: (1) data dictionary or terminology, (2) data ontology and schemas, and (3) data platforms. The data are grouped into ten typologies covering most types of data collected in buildings. This study resulted in five main findings: (1) most data representation tools can represent their intended data typologies well, such as Green Button for smart meter data and Brick schema for metadata of sensors in buildings and HVAC systems, but none of the tools cover all ten types of data; (2) there is a need for data schemas to represent the basis of design data and metadata of occupant data; (3) standard terminologies such as those defined in BEDES are only adopted in a few data tools; (4) integrating data across various stages in the building life cycle remains a challenge; and (5) most data tools were developed and maintained by different parties for different purposes, their flexibility and interoperability can be improved to support broader use cases. Finally, recommendations for future research on building data tools are provided for the data and buildings community based on the FAIR principles to make data Findable, Accessible, Interoperable, and Reusable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Integrated Mechanical Pods

This presentation highlights early wins, updated progress, and upcoming developments on ‘national-scale shared development platform’ for rapid prototyping, testing and validation of various integrated Mechanical Pod solutions and form factors. Such pod solutions consist of a set of all-electric heat pump mechanical equipment that have integrated functionalities through built-in controls, with heating, cooling, hot water, ventilation (including energy recovery), electrical management, and battery storage within a single package. The presentation draws inspiration from the success of bathroom pods in the US modular construction industry, UK’s efforts with unitizing mechanical systems as ‘utility cupboards’, and VEIC’s early wins in design-build of all-electric Mechanical Pod solutions in Vermont. The presentation includes researchers and partners involved with NREL in Design for Manufacturing and Assembly (DfMA), Virtual Design and Construction (VDC), and digital twin based process optimization modeling of integrated Mechanical Pod solutions. The presentation aims to highlight early wins from such a platform and how various physical and virtual tools are currently being employed as part of NREL’s ongoing multi-year project funded by US DOE. Streamlined procurement, coordination, installation, and O&M of Mechanical Pods such that the majority of work is delegated to the off-site modular factory implies monetary savings. Such a seemingly basic shift in location of the construction process leads to great reduction in complexity, first cost, lead time, and waste, and greater opportunities for innovative compartmentalization and integration of mechanical systems appropriately sized for each apartment or hotel guest room. However, past studies on unitized combination systems show that high installation costs, maintenance issues, challenges with system integration, limitations in existing electrical infrastructure, and lack of architecturally appealing solutions are key barriers. NREL and partners aim to address key barriers through DfMA approach, rapid prototyping and testing, and digital twin process optimization modeling. The presentation is also a call for interested entities to partner with NREL as part of the national-scale development platform, help drive both product and process innovation, and encourage open source sharing of learnings. Learning objectives include (1) learn about the vision of national-scale shared development platform for process-product innovation on integrated mechanical pod solutions and how to get involved, (2) gain an understanding of the components of an all-electric, high performance home, design characteristics and equipment included in an all-electric mechanical pod, integration of mechanical systems within a modular factories’ assembly line, and the system’s commissioning, operation and maintenance. The pre-planning and coordination with the factory and sub-contractors are also highlighted, (3) gain an understanding of using process modeling tools to quantify resource-constrained performance of operations (such as integration of energy efficiency strategies) to manufacture modules of varying design, (4) gain insights on virtual design, rapid prototyping, and emulated testing of various form factors across different climatic conditions. The need for such preliminary testing with open source sharing of learnings will also be highlighted.

30 DIRECT ENERGY CONVERSION↗

Designing reinforcement learning algorithms for building HVAC control: From experimental observation to simulation comparisons

Advanced supervisory-level control with reinforcement learning (RL) is regarded as a promising solution for HVAC systems to minimize energy consumption while maintaining thermal comfort and indoor air quality. However, most RL applications were conducted in the simulation environment rather than real-world HVAC systems. This paper developed a value-based RL controller termed Deep Q-Network (DQN) for a typical central HVAC system and evaluated its performance in a building test facility. By comparing DQN with a rule-based controller, the study not only demonstrated the cases where DQN could properly maintain indoor comfort but also discussed possible reasons why DQN failed in some other situations. Recognizing the limitations of value-based RL algorithms from the experimental tests, a simulation study was conducted to compare DQN with an alternative RL approach, an actor–critic algorithm termed Deep Deterministic Policy Gradient (DDPG). In scenarios with a relatively large action space, DDPG outperformed DQN by requiring fewer computational resources and achieving better thermal comfort, lower energy consumption, and more stable control actions. The findings suggest that the ability of DDPG to handle continuous control variables more effectively allows for faster convergence in training and more precise control in practice, which enhances the overall efficiency and reliability of the HVAC system.

Guo, Fangzhou↗

Model-based Design Optimization to Achieve the Performance Goals (16.0 SEER/9.5 HSPF), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Usage of low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Our research in previous milestone report has shown that using heat exchangers with 5 mm diameter tubes instead of 9 mm diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants. In addition, the 5mm tube heat exchangers can lead to lower system refrigerant charge and as a result, reduce environmental impact further. However, shifting to small tube diameters requires in-depth heat exchanger design optimization to adapt to the transition to low-GWP refrigerants. In the 2nd quarter of FY21, we conducted multi-objective optimizations using Particle Swarm Optimization algorithm on a residential 5-ton air source heat pump to investigate the potential system performance improvements and material savings. 4 low-GWP refrigerants, ARM20A, ARM20B, R454A and R454C are investigated in this study. The objectives of the optimization are to minimize the heat pump material cost and to maximize the system performance simultaneously. As a result, the HXs material cost is reduced by up to 77% according to the copper and aluminum material price in current market. Under heating mode operation, the smart 4-way valve guarantees that the optimal low-GWP systems maintain or outperform the heating performance of the R410A baseline system. The model-based design optimization yields 18.3-18.9 SEER and 10.6-11.9 HSPF for optimal systems using different low-GWP refrigerants. The initial performance goals (16.0 SEER/9.5 HSPF) are achieved. Furthermore, up to 50% system refrigerant charge reduction is possible in the optimized low-GWP heat pump system using ARM20B. And 91%-95% predicted life-time direct CO 2 emission reduction is achieved by using the optimal 5mm tube low-GWP heat pumps. The significant material saving, charge reduction and direct CO 2 emission reduction help in reducing the environmental impacts of heat pump systems. The optimal heat exchangers resulting from this research can fit into the original baseline indoor and outdoor fan-coil unit. This can reduce the retrofitting effort by minimizing the change in manufacturing and installation of the heat pumps and guarantee the compatibility with end-users’ house structure. Finally, the new products can be easily accepted by manufacturers and end-users.

42 ENGINEERING↗

Review of Variable Geometry Air-to-Refrigerant Heat Exchangers

Air-to-refrigerant heat exchangers (HXs) are fundamental components to HVAC&R systems and as a result there is an ever-increasing need for performance and packaging improvements. Typically, HX’s are designed in uniform arrangements with the goal of providing the necessary heat transfer for minimal material costs. Recent research on fin tube heat exchangers (FTHX) with variation in one or more key parameters has shown significant potential for increasing heat transfer, reducing pressure losses, and making HXs more resilient to environmental externalities like airflow maldistribution and frost accumulation. In particular, researchers have increased heat transfer by 7.6% and j/f by 16% via non-uniform tube and winglet shapes. Additionally, multiple cases have shown that variable geometry heat exchangers (VGHX) are able to match the performance of conventional HXs with reductions in material mass and envelope volume of up to 33% and 40%, respectively. This paper presents a literature review of VGHXs specifically with regards to non-uniform FTHX’s.

42 ENGINEERING↗

Infrared-Fused Vision-Based Thermoregulation Performance Estimation for Personal Thermal Comfort-Driven HVAC System Controls

Thermal comfort is one of the primary factors influencing occupant health, well-being, and productivity in buildings. Existing thermal comfort systems require occupants to frequently communicate their comfort vote via a survey which is impractical as a long-term solution. Here, we present a novel thermal infrared-fused computer vision sensing method to capture thermoregulation performance in a non-intrusive and non-invasive manner. In this method, we align thermal and visible images, detect facial segments (i.e., nose, eyes, face boundary), and accordingly read the temperatures from the appropriate coordinates in the thermal image. We focus on the human face since it is often clearly visible to cameras and is not merged into a hot background (unlike hands). We use a regularized Gaussian Mixture model to track the thermoregulation changes over time and apply a heuristic algorithm to extract hot and cold indices. We present a personalized and a generalized comfort modeling method, selected based on the availability of the occupant historical indices measurements in a neutral environment, and use the time-series of the hot and cold indices to define corrections to HVAC system operations in the form of setpoint constraints. To evaluate the efficacy of our proposed approach in responding to thermal stimuli, we designed a series of controlled experiments to simulate exposure to cold and hot environments. While applying personalized modeling showed an acceptable average accuracy of 91.3%, the generalized model’s average accuracy was only 65.2%. This shows the importance of having access to physiological records in modeling and assessing comfort. We also found that individual differences should be considered in selecting the cooling and heating rates when some knowledge of the occupant’s overall thermal preference is available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Detritiation Strategies for Mitigating Tritium Releases

Tritium confinement is performed using different barriers to minimize releases to the environment. Primary confinement is usually performed by process piping and components, secondary confinement typically by inerted gloveboxes connected to a continuously operating tritium stripper system. Some facility designs employ tertiary tritium confinement by using process room confinement with a tritium stripper system activated after an accident to further mitigate tritium releases to the environment. Secondary confinement of some tritium systems such as radiation-hardened or shielded-cell enclosures are not easily achieved using designs for inerted glovebox. These enclosures can be challenging to seal for secondary tritium confinement due to heating, ventilation, and air conditioning (HVAC) needs for temperature control, as well as feedthroughs for equipment and instrumentation, are potential pathways for tritium leaks or loses. Additional tritium leak paths can be created in secondary confinement enclosures due to a Design Basis Accident (DBA) seismic event. These new, larger tritium leak rates from the DBA event are usually not part of the stripper system design basis so all tritium released to the secondary confinement enclosure is assumed released to the environment. Detritiation strategies for shielded enclosures and/or gloveboxes with significant leak rates are necessary to minimize off-site radiological dose consequences. To address this, the relationship between the confinement system leak rate and stripper system (recirculating) flow rate was evaluated to meet prescribed maximum allowable environmental tritium emissions from the event. The simple analysis described assumes a constant leak rate from the confinement system (i.e. shielded enclosure or glovebox) while a recirculating stripper system strips tritium from the system– a competition between tritium release and tritium recovery. At a high level, the resulting expression summarizes the relationship between system leak rate (F L ) and stripper flow rate (F S ) relative to allowable tritium release (Q A ) and initial tritium release (Q 0 ): $\frac{F_L}{F_s}$ ≈ $\frac{Q_A}{Q_0}$. This report derives the relationship between these parameters, examines the impact of finite stripping times followed by purging of the stripped volume. The analysis provides example results for up to 30 gram tritium releases: the maximum tritium inventory of a Hazard Category III (Department of Energy) Nuclear Facility. The detritiation model presented represents a high-level analysis of tritium recovery versus losses for “leaky” confinement enclosures such as shielded cells after large tritium releases. Key parameters for doing the analyses are the system leak rate, stripper flow rate, initial tritium release, and allowable tritium release values. The analyses show a proportional decrease in releases with reduction in initial tritium release but a non-linear increase in tritium recovery with increased stripper flow rate or reduced leak-rate. The analyses also apply to glovebox confinement systems which could have significant increases in leak rates after a DBA. The analysis recognizes but does not include tritium absorption followed by re-emission from the walls of the confinement volume – an analysis which could be pursued in future studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Automated Control of Transactive HVACs in Energy Distribution Systems

Heating, Ventilation, and Air Conditioning (HVAC) systems contribute significantly to a building’s energy consumption. In the recent years, there is an increased interest in developing transactive approaches which could enable automated and flexible scheduling of HVAC systems based on the customer demand and the electricity prices decided by the suppliers. Flexible and automated scheduling of the HVAC systems make it a prime source for participation in residential demand response or transactive energy systems. Therefore, it is of significant interest to identify an optimal strategy to control the HVAC systems. Here, reducing the energy cost while keeping the comfort level acceptable to the users, we argue that such a control strategy should consider both the energy cost and user comfort simultaneously. Accordingly, we develop the control strategy through the solution of an optimization problem that balances between the energy cost and consumer’s dissatisfaction. This optimization enables us to solve a decision-making problem through first price prediction and then choosing HVAC temperature settings throughout the day based on the predicted price, history of the price and HVAC settings, and outside temperature. More specifically, we formulate the control design as a Markov decision process (MDP) using deep neural networks and use Deep Deterministic Policy Gradients (DDPG)-based deep reinforcement learning algorithm to find the optimal control strategy for HVAC systems that balances between electricity cost and user comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES)

The C2SAGES project evaluated the feasibility of a community geothermal system for the planned Windy Ridge affordable housing development in Hinesburg, Vermont. Led by GTI Energy with Vermont Gas Systems, LN Consulting, NREL, and Frontier Energy, the work assessed technical design, energy performance, costs, business models, community engagement, maintenance, workforce development, and permitting. The proposed system was designed to serve 100% of the development’s heating, cooling, and domestic hot water loads. Compared with a baseline using air-source heat pumps and natural gas water heating, the geothermal system was estimated to reduce HVAC and domestic hot water energy use by about 45% to 48%, lower operating and maintenance costs, and reduce 30-year life-cycle costs by 37% for Phase 1 and 10% for Phase 2. Technical testing and modeling indicated that the Windy Ridge site is suitable for a community-scale geothermal system. The project also developed borehole field layouts, piping concepts, pump house designs, controls, maintenance plans, and supporting engineering drawings. The business model analysis found that first cost, ownership structure, and customer affordability remain major deployment challenges. Utility-led maintenance and operation were viewed favorably, but traditional utility cost-recovery models may require subsidy or revised financing structures to be practical for affordable housing. Community engagement highlighted the need for clear public education, transparent financing, reliable long-term maintenance, trained technicians, and the potential to pair geothermal systems with weatherization. Overall, the report concludes that community geothermal is technically feasible and offers meaningful energy, emissions, and life-cycle cost benefits, but broader deployment will depend on workable financing models and workforce readiness.

15 GEOTHERMAL ENERGY↗

Innovative approach to counterfeit and noncompliant refrigerant detection: A cost-effective, portable solution

The increasing prevalence of counterfeit and incompatible refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems, including compromised equipment performance, safety hazards, and non-compliance. This article details the development of a novel, cost-effective, and portable detection device designed to accurately verify refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing feedback within a 2-minute duration. Laboratory validation demonstrated the device’s high accuracy (>95 % based on correct identification of compliant vs. non-compliant blends) in detecting unauthorized refrigerant blends. The projected cost of the product stands at ∼ $150, based on the retail pricing of individual components. Laboratory validation demonstrated the device’s high accuracy (>95 % for composition identification, 100 % rejection of tested counterfeit/incorrect blends) in detecting unauthorized refrigerant blends with a response time <2 min. The device correctly identified authentic R-454A/B/C blends and reliably rejected R-407F and closely related counterfeit mixtures. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks, enhances safety in HVAC&R operations, and mitigates the risks associated with counterfeit refrigerants.

Counterfeit refrigerants↗

STRESS AND FATIGUE ANALYSIS OF AIR-TO-REFRIGERANT HEAT EXCHANGERS WITH NON-ROUND TUBE SHAPES

Air-to-refrigerant heat exchangers are fundamental components in Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems. Recent research has shown that heat exchangers utilizing small hydraulic diameter, non-round, shape-optimized tubes to be promising next design update. Such tubes can improve performance, reduce material and lower refrigerant charge. However, such tube designs may be more susceptible to fatigue issues. Therefore, stress and fatigue analyses of such heat exchangers are critical to ensure structural integrity, reliability, and manufacturability. In the present work, a mechanical model is developed to obtain the stress distributions in heat exchangers with round, ellipse, and airfoil-shaped tubes. The results indicate that under 3.45 MPa internal pressure, the maximum stresses don't surpass 190 MPa.

Zhang, Mingkan↗

A review of future weather data for assessing climate change impacts on buildings and energy systems

The effectiveness of climate change impact assessments and the development of adaptation strategies depend on the availability of high-quality future weather data. However, significant gaps exist between the needs of the energy research community and the focus of the climate modeling community, primarily due to a historical lack of communication and collaboration between the two groups. Here, to address this issue, this work provides a comprehensive overview of the critical aspects involved in creating future weather data for building and energy system modeling, including emissions scenarios, general circulation models, downscaling methods, categories of future weather data, and uncertainties in climate simulations. Moreover, it critically evaluates the applicability and suitability of various types of future weather data in five key application scenarios: energy use analysis, resilience analysis, HVAC design, utility-scale analysis, and renewable energy analysis. Finally, this work presents recommendations for high-level actions and research directions to foster collaboration between the energy research and climate modeling communities and to promote the integration of future weather data into energy codes and the design practices of buildings and energy systems.

Climate change↗

Empower Wall: Active insulation system leveraging additive manufacturing and model predictive control

Buildings are one of the largest energy consumers worldwide, using large amounts of energy during their construction and for climate control during operation. Active insulation systems (AIS) have been shown to reduce the energy needed for climate control in buildings by dynamically regulating the heat transferred between a building’s interior and exterior. Infrastructure-scale additive manufacturing (AM) has the potential to reduce the resources needed for building construction. Combining these two technologies into a single building envelope would create a path towards more sustainable buildings. A test was conducted for the Federal Energy Management Program (FEMP) Energy Exchange training and trade show, in August 2021, to investigate a new building envelope design, termed the Empower Wall, that utilized an AIS and was constructed using AM. Model predictive control was implemented to manage operation of the Empower Wall in concert with the existing HVAC system. Finally, the prototype system demonstrated that the Empower Wall lowered total energy consumption and reduced the cost of energy used.

36 MATERIALS SCIENCE↗

Decarbonizing HVAC and Water Heating in Commercial Buildings

This report is intended to provide building owners and facilities engineers with heating electrification options and design considerations, as well as additional resources on key topics. The document focuses on the electrification of space heating and water heating loads using electric heat pump systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗