Search NASA⌕ Search

SEARCH · Search NASA

Results for “The Random Ray Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effect of Ex Vivo Ionizing Radiation on Static and Fatigue Properties of Mouse Vertebral Bodies

For a variety of medical and scientific reasons, human bones can be exposed to a wide range of ionizing radiation levels. In vivo radiation therapy (0.05 kGy) is used in cancer treatment, and ex vivo irradiation (25-35 kGy) is used to sterilize bone allografts. Ionizing radiation in these applications has been shown to increase risk of fracture, decrease bone quality and degrade collagen integrity. Past studies have investigated the deleterious effects of radiation on cortical or trabecular bone specimens individually, but to date no studies have examined whole bones containing both cortical and trabecular tissue. Furthermore, a clear relationship between the dose and the mechanical and biochemical response of bone's extracellular matrix has yet to be established for doses ranging from cancer therapy to allograft sterilization (0.05-35 kGy). To gain insight into these issues, we conducted an ex vivo radiation study to investigate non-cellular (i.e. matrix) effects of ionizing radiation dose on vertebral whole bone mechanical properties, over a range of radiation doses (0.05-35 kGy), with a focus on any radiation-induced changes in collagen. With underlying mechanisms of action in mind, we hypothesized that any induced reductions in mechanical properties would be associated with changes in collagen integrity. METHODS: 20-week old female mice were euthanized and the lumbar spine was dissected using IACUC approved protocols. The lumbar vertebrae (L1- S1) were extracted from the spine via cuts through adjacent intervertebral discs, and the endplates, posterior processes, surrounding musculature, and soft tissues were removed (approx. 1.5mm diameter, approx. 2mm height). Specimens were randomly assigned to one of five groups for ex vivo radiation exposure: x-ray irradiation at 0.05, 1, 17, or 35 kGy, or a 0 kGy control. Following irradiation, the vertebrae were imaged using microcomputed tomography (micro-CT) and then subjected to either monotonic compressive loading to failure or uniform cyclic compressive loading. During cyclic testing, samples were loaded in force control to a force level that corresponded to a strain of 0.46%, as determined in advance by a linearly elastic micro-CT-based finite element analysis for each specimen. Tests were stopped at imminent fracture, defined as a rapid increase in strain. The main outcome for the monotonic test was the strength (maximum force); for cyclic testing it was the fatigue life (log of the number of cycles of loading at imminent failure). A fluorometric assay was used on the S1 vertebrae to measure the number of non-enzymatic collagen crosslinks[4]. A one-way ANOVA was performed on mechanical properties and collagen crosslinks; means were compared with controls using Dunnett's method, with a Tukey-Kramer post-hoc analysis when significance was found (p < or = 0.05). RESULTS: Compared to the unirradiated control group, the concentration of non-enzymatic collagen crosslinks was significantly increased for all irradiated groups (p < 0.0001), and being higher by at least 50% (Figure 1a). By contrast, the radiation effects on the collagen were only evident at the higher doses. For irradiation exposures of 17 kGy or more, strength decreased substantially as the radiation level was increased, but no effect was evident below 17 kGy (Figure 1b). There was no significant change in the stiffness or maximum displacement for any radiation dose (p>0.05). The finite element analysis prescribed force level for cyclic loading exceeded the measured (monotonic) strength of the 17 and 35 kGy irradiated groups (mean +/- SD, 20.6 +/- 5.6 N; 13.2 +/- 3.7 N, respectively) and therefore these groups were eliminated from the fatigue study. The fatigue life for the 0.05 and 1 kGy groups were similar to each other and were not statistically significantly different from the control group (Figure 1c).

radiation↗

Interlaboratory Study of Digital Volume Correlation Error Due to X-Ray Computed Tomography Equipment and Scan Parameters: an Update from the DVC Challenge

Background: The quality of Digital Volume Correlation (DVC) full-field displacement measurements depends directly on the characteristics of the X-ray Computed Tomography (XCT) equipment, and scan procedures used to acquire the tomographic images. Objective: In this work, we seek to experimentally study the effects of XCT equipment and tomographic scan procedures on the quality of these images for DVC analysis, and to survey the level of DVC error that may be achieved using standard XCT operating procedures. Methods: Six participants in an interlaboratory study acquired high-quality XCT scans of a syntactic foam before and after rigid body motion. The resulting images were correlated using commercial DVC software to quantify error sources due to random image noise, reconstruction artifacts, as well as systematic spatial or temporal distortion. Results: In the absence of rigid body motion, the standard deviation of the displacement measurements ranged from 0.012 to 0.043 voxels using a moderate subvolume size, indicating that subvoxel measurement resolution could readily be achieved with a variety of XCT equipment and scan recipes. Comparison of consecutive scans without rigid body motion showed transient dilatational displacement gradients due to self-heating of the X-ray source and/or thermal expansion of the foam. Evaluation of the scans after rigid body motion showed significant, machine-specific spatial distortion in the displacement fields of up to 0.5 voxels; new approaches to remove this error need to be developed. Conclusions: Analysis of the scan protocols used in the interlaboratory study, as well as a complementary parametric sensitivity study, showed that the DVC error was strongly influenced by the XCT equipment, but could be mitigated by adjusting the total scan duration.

47 OTHER INSTRUMENTATION↗

Using porous random fields to predict the elastic modulus of unoxidized and oxidized superfine graphite

Nuclear graphite is a candidate material for Generation IV nuclear power plants. Porous materials such as graphite can contain complex networks of pores that influence the material's mechanical and irradiation response. A methodology known as the random finite element method (RFEM) was adapted to create synthetic microstructures and predict the influence of porosity on the elastic properties of graphite during oxidation. RFEM combines random field theory and the finite element method in a Monte Carlo framework to estimate the mechanical response of a given grade of graphite. In this research, the random fields were verified through experimental characterization to predict the elastic response of three nuclear graphite grades, ETU-10, IG-110, and 2114. Finite element models (FEM) were generated using segmentations of x-ray computed tomography (XCT) data known as image-based models (IBMs) to validate and compare with the RFEM results and better understand the effects of uniform oxidation in these graphite grades. The RFEM predictions appear to correlate well with the experimental values of the measured Young’s modulus of the three graphite grades and display the same trends as IBMs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Deep-learning-based image registration for nano-resolution tomographic reconstruction

Nano-resolution full-field transmission X-ray microscopy has been successfully applied to a wide range of research fields thanks to its capability of non-destructively reconstructing the 3D structure with high resolution. Due to constraints in the practical implementations, the nano-tomography data is often associated with a random image jitter, resulting from imperfections in the hardware setup. Without a proper image registration process prior to the reconstruction, the quality of the result will be compromised. Here a deep-learning-based image jitter correction method is presented, which registers the projective images with high efficiency and accuracy, facilitating a high-quality tomographic reconstruction. This development is demonstrated and validated using synthetic and experimental datasets. We report the method is effective and readily applicable to a broad range of applications. Together with this paper, the source code is published and adoptions and improvements from our colleagues in this field are welcomed.

deep learning↗

Tortuosity Computations of Porous Materials using the Direct Simulation Monte Carlo

Low-density carbon fiber preforms, used as thermal protection systems (TPS) materials for planetary entry systems, have permeable, highly porous microstructures consisting of interlaced fibers. Internal gas transport in TPS is important in modeling the penetration of hot boundary-layer gases and the in-depth transport of pyrolysis and ablation products. The gas effective diffusion coefficient of a porous material must be known before the gas transport can be modeled in material response solvers; however, there are very little available data for rigid fibrous insulators used in heritage TPS.The tortuosity factor, which reflects the efficiency of the percolation paths, can be computed from the effective diffusion coefficient of a gas inside a porous material and is based on the micro-structure of the material. It is well known, that the tortuosity factor is a strong function of the Knudsen number. Due to the small characteristic scales of porous media used in TPS applications (typical pore size of the order of 50 micron), the transport of gases can occur in the rarefied and transitional regimes, at Knudsen numbers above 1. A proper way to model the gas dynamics at these conditions consists in solving the Boltzmann equation using particle-based methods that account for movement and collisions of atoms and molecules.In this work we adopt, for the first time, the Direct Simulation Monte Carlo (DSMC) method to compute the tortuosity factor of fibrous media in the rarefied regime. To enable realistic simulations of the actual transport of gases in the porous medium, digitized computational grids are obtained from X-ray micro-tomography imaging of real TPS materials. The SPARTA DSMC solver is used for simulations. Effective diffusion coefficients and tortuosity factors are obtained by computing the mean-square displacement of diffusing particles.We first apply the method to compute the tortuosity factors as a function of the Knudsen number for computationally designed materials such as random cylindrical fibers and packed bed of spheres with prescribed porosity. Results are compared to literature values obtained using random walk methods in the rarefied and transitional regime and a finite-volume method for the continuum regime. We then compute tortuosity factors for a real carbon fiber material with a transverse isotropic structure (FiberForm), quantifying differences between through-thickness and in-plain tortuosities at various Knudsen regimes.

Tortuosity↗

Texture Evolution of Plated Lithium in Anode-Free Solid-State Batteries

Here, this study investigates lithium plating texture in anode-free solid-state batteries using synchrotron-based X-ray diffraction. Conventional methods are limited by lithium’s low electron density and softness, which hinders direct interrogation in anode-free solid-state batteries. Results reveal that lithium plating texture is influenced by temperature and current density. Under mild conditions, lithium exhibited a ⟨110⟩ fiber texture. However, higher current densities and elevated temperatures led to a more randomized orientation, suggesting a dependence on plating conditions. The results highlight how the operating and processing conditions for lithium metal can influence the texture of lithium metal and reversible operation.

36 MATERIALS SCIENCE↗

Efficient reconstruction and validation of heterogeneous microstructures for energy applications

The digital reconstruction of microstructures is necessary for simulations in fields ranging from geology to electrochemistry, but the state-of-the-art digital reconstruction techniques often compromise between resolution and field of view. It is challenging to retain detailed microstructure information in large-scale reconstructions. Here, this study investigates different aspects of the Yeong-Torquato algorithm based on correlation functions to make it more efficient. We achieve this goal by reducing the computational complexity of the chord-length distribution function and the two-point correlation function, applying the random sphere-packing method as the initial condition, and restricting potential voxel swaps to interfaces. In addition, a novel superposition parallel scheme is introduced to aid in searching for potential voxel swaps. The algorithm proposed is validated by comparing the pore-size distributions of reconstructed 3D custom battery electrodes from a sample dataset obtained from transmission X-ray microscopy. From a sample image with 200 x 200 pixels, the code can reconstruct a 300 x 300 x 300 structure in under 22 h and reconstruct a 400 x 400 x 400 structure in 43 h with eight cores.

42 ENGINEERING↗

Linear polarization sensitivity specifications for space-borne instruments

The radiometric accuracy of space-borne instruments such as radiometers and spectroradiometers which make measurements of the earth and other celestial objects can be compromised by the linear polarization sensitivity (LPS) induced by the optical system. Most of these optical systems contain optical elements whose reflectance or transmission is polarization dependent, such as diffraction gratings, folding and scanning mirrors, dichroic filters, and optical fibers. Optical system incorporating such elements generally display linear polarization sensitivity; different linear polarization states incident with equal radiometric power will be measured as different power levels. If the incident polarization state is unknown, the linear polarization sensitivity cannot be compensated during the data reduction. The light reflected from the earth and other planets and moons is usually partially linearly polarized, but in a random distribution. Thus, to make accurate radiometric measurements of these bodies, a radiometer or spectrometer should have a low level of linear polarization sensitivity. This paper contains a mathematical description of LPS, contains references to systems which have imposed a LPS specification, describes some of the sources of LPS, describes how to model LPS by polarization ray tracing, and discusses methods to reduce the LPS of an optical system.

Maymon, Peter W.↗

A new approach to cosmic ray diffusion theory

An approach is presented for deriving a diffusion equation for charged particles in a static, random magnetic field. The approach differs from the usual, quasi-linear one, in that particle orbits in the average field are replaced by particle orbits in a partially averaged field. In this way the fluctuating component of the field significantly modifies the particle orbits in those cases where the orbits in the average field are unrealistic. The method permits the calculation of a finite value for the pitch angle diffusion coefficient for particles with a pitch angle of 90 rather than the divergent or ambiguous results obtained by quasi-linear theories. Results of the approach are compared with results of computer simulations using Monte Carlo techniques.

Jones, F. C.↗

Turbulent and directed plasma motions in solar flares

An improved method for fitting asymmetric soft X-ray line profiles from solar flares is presented. A two-component model is used where one component represents the total emission from directed upflow plasma and the other the emission from the plasma at rest. Unlike previous methods, the width of the moving component is independent from that of the stationary component. Time variations of flare plasma characteristics (i.e., temperature, emission measure of moving and stationary plasma, upflow and turbulent velocities) are derived from the Ca XIX and Fe XXV spectra recorded by the Bent Crystal Spectrometer on the Solar Maximum Mission. The fitting technique provides a statistical estimation for the uncertainties in the fitting parameters. The relationship between the directed and turbulent motions has been studied, and a correlation of the random and directed motions has been found in some flares with intensive plasma upflows. Mean temperatures of the upflowing and stationary plasmas are compared for the first time from ratios of calcium to iron X-ray line intensities. Finally, evidence for turbulent motions and the possibility of plasma upflow late into the decay phase is presented and discussed.

Fludra, A.↗

High pressure chemical reactivity and structural study of the Na–P and Li–P systems

In this work, the Na–P and Li–P chemical systems were studied under pressure using synchrotron X-ray diffraction in a diamond anvil cell up to 20 GPa, combined with the AIRSS ab initio random structure searching technique. The results reveal an enhanced reactivity of both alkali metals with phosphorous at slightly elevated pressures. This enables the synthesis of Li 3 P and Na 3 P at room temperature (RT) starting from element precursors, bypassing the established chemical synthesis methods. Both compounds undergo a pressure-induced phase transition from the hexagonal Na 3 As-type structure (stable at ambient conditions) towards a Fm m (FCC) structure that remains stable up to 20 GPa. Attempts to synthesize compounds with higher alkali metal content (such as Li 5 P) using high-temperature and -pressure conditions (up to 2000+ K and 30 GPa), inspired by recent theoretical predictions, were not successful.

25 ENERGY STORAGE↗

Survey of Image Denoising Methods for Medical Image Classification

Medical imaging devices, such as X-ray machines, inherently produce images that suffer from visual noise. Our objectives were to (i.) determine the effect of image denoising on a medical image classification task, and (ii.) determine if there exists a correlation between image denoising performance and medical image classification performance. We performed the medical image classification task on chest X-rays using the DenseNet-121 convolutional neural network (CNN) and used the peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) metrics as the image denoising performance measures. We first found that different denoising methods can make a statistically significant difference in classification performance for select labels. We also found that denoising methods affect fine-tuned models more than randomly-initialized models and that fine-tuned models have significantly higher and more uniform performance than randomly-initialized models. Lastly, we found that there is no significant correlation between PSNR and SSIM values and classification performance for our task.

Michael, Peter↗

Single-frame far-field diffractive imaging with randomized illumination

We introduce a single-frame diffractive imaging method called randomized probe imaging (RPI). In RPI, a sample is illuminated by a structured probe field containing speckles smaller than the sample’s typical feature size. Quantitative amplitude and phase images are then reconstructed from the resulting far-field diffraction pattern. The experimental geometry of RPI is straightforward to implement, requires no near-field optics, and is applicable to extended samples. When the resulting data are analyzed with a complimentary algorithm, reliable reconstructions which are robust to missing data are achieved. To realize these benefits, a resolution limit associated with the numerical aperture of the probe-forming optics is imposed. RPI therefore offers an attractive modality for quantitative X-ray phase imaging when temporal resolution and reliability are critical but spatial resolution in the tens of nanometers is sufficient. We discuss the method, introduce a reconstruction algorithm, and present two proof-of-concept experiments: one using visible light, and one using soft X-rays.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Updates to the Regional Seismic Travel Time (RSTT) Model: 2. Path-dependent Travel-time Uncertainty

Abstract The regional seismic travel time (RSTT) model and software were developed to improve travel-time prediction accuracy by accounting for three-dimensional crust and upper mantle structure. Travel-time uncertainty estimates are used in the process of associating seismic phases to events and to accurately calculate location uncertainty bounds (i.e. event location error ellipses). We improve on the current distance-dependent uncertainty parameterization for RSTT using a random effects model to estimate slowness (inverse velocity) uncertainty as a mean squared error for each model parameter. The random effects model separates the error between observed slowness and model predicted slowness into bias and random components. The path-specific travel-time uncertainty is calculated by integrating these mean squared errors along a seismic-phase ray path. We demonstrate that event location error ellipses computed for a 90% coverage ellipse metric (used by the Comprehensive Nuclear-Test-Ban Treaty Organization International Data Centre (IDC)), and using the path-specific travel-time uncertainty approach, are more representative (median 82.5% ellipse percentage) of true location error than error ellipses computed using distance-dependent travel-time uncertainties (median 70.1%). We also demonstrate measurable improvement in location uncertainties using the RSTT method compared to the current station correction approach used at the IDC (median 74.3% coverage ellipse).

58 GEOSCIENCES↗

A new approach to cosmic ray diffusion theory

We have investigated a new approach to deriving a diffusion equation for charged particles in a static, random magnetic field. Our approach differs from the usual, quasi-linear one, in that we replace particle orbits in the average field by particle orbits in a partially averaged field. In this way, the fluctuating component of the field significantly modifies the particle orbits in those cases where the orbits in the average field are unrealistic. This method allows us to calculate a finite value for the pitch angle diffusion coefficient for particles with a pitch angle of 90 deg rather than the divergent or ambiguous results obtained by quasi-linear theories.

Jones, F. C.↗

DEM Modeling and Validation of Pebble Bed Packing Using Chrono::GPU

Accurate prediction of pebble packing structure is important for pebble bed reactors because the spatial distribution of void fraction directly affects coolant flow, pressure drop, heat transfer, and neutronic behavior. However, experimentally validated DEM studies that directly evaluate local void-fraction structure in reactor-relevant pebble beds remain limited. In this work, the pebble bed experiment conducted at Missouri University of Science and Technology is simulated using the graphics processing unit (GPU)-based discrete element method (DEM) code Chrono::GPU. The study focuses on evaluating the ability of Chrono::GPU to reproduce the packing arrangement and void-fraction distribution of a randomly packed spherical pebble bed. The DEM results are first verified against established radial void-fraction correlations, including the Mueller and Vortmeyer-Schuster models, to assess the predicted bulk porosity, near-wall behavior, and oscillatory packing structure. The simulation is then verified against reference DEM data and validated against gamma-ray computed tomography (CT) experimental data at three axial locations. The Chrono::GPU results reproduce the main features of the experimental packing, including the high void fraction near the wall, the first near-wall trough, and the damped oscillatory radial profile caused by wall-induced ordering. Quantitative comparison with DEM data and the CT-based radial profiles shows good agreement, with mean absolute errors on the order of 0.07 and root-mean-square errors below 0.09 for the averaged profiles. These results demonstrate that Chrono::GPU can accurately capture the void-fraction structure of spherical pebble beds and provides a reliable DEM framework for future pebble bed reactor packing, recycling, and thermal-hydraulic studies.

97 - MATHEMATICS AND COMPUTING↗

Radiation Test Challenges for Scaled Commerical Memories

As sub-100nm CMOS technologies gather interest, the radiation effects performance of these technologies provide a significant challenge. In this talk, we shall discuss the radiation testing challenges as related to commercial memory devices. The focus will be on complex test and failure modes emerging in state-of-the-art Flash non-volatile memories (NVMs) and synchronous dynamic random access memories (SDRAMs), which are volatile. Due to their very high bit density, these device types are highly desirable for use in the natural space environment. In this presentation, we shall discuss these devices with emphasis on considerations for test and qualification methods required.

LaBel, Kenneth A.↗

Study of cosmic ray scintillations from 5-minute data of the scintillations telescope Izmran and world-wide network stations

During cosmic ray propagation in interplanetary space there appear characteristic cosmic-ray intensity scintillations which are due to charged particle scattering on random inhomogeneities of the interplanetary magnetic field. The power spectra of cosmic ray scintillations on the Earth during some intervals from 1977 to 1982 (for quiet periods, for solar flares and Forbush decreases due to power shock waves) have been calculated from five-minute, one and two-hour values of the cosmic-ray intensity measured by the scintillator supertelescope IZMIRAN. The spectra were estimated by the methods of spectral analysis and by autoregressive methods which mutually control each other and make it possible not only to analyze scintillation powers at distinguished frequencies, but also to determine the behavior of spectrum slopes in some frequency ranges.

Gulinsky, O. V.↗