Search NASA⌕ Search

SEARCH · Search NASA

Results for “low background”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 uBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

First 3D vector tracking of helium recoils for fast neutron measurements at Super$\mathrm{KEKB}$

Here we present results from the first deployment of novel, high definition, compact gas Time Projection Chambers (TPCs) with pixel chip readout as part of the BEAST II beam background measurement project at SuperKEKB. The TPCs provide detailed 3D imaging of ionization from neutron-induced nuclear recoils in a helium and carbon dioxide target gas mixture at standard temperature and pressure. We present the TPC performance and the neutron backgrounds observed during the initial stage of collider commissioning. We find excellent electron background rejection, leading to background-free nuclear recoil measurements above 50 keV ee , despite the extreme high-background environment. We measure an angular resolution better than 20° for recoil tracks longer than 1.7 mm, corresponding to an average ionization energy of approximately 100 keV ee . We also obtain the full 3D vector direction of helium recoils by utilizing charge profile measurements along the recoil axis, with a correct head/tail assignment efficiency of approximately 80%. With this performance, we present comparisons between measured and simulated event rates, recoil energy spectra, and directional distributions originating from beam–gas and Touschek beam losses at SuperKEKB. We utilize head/tail recognition to distinguish neutron components traveling with positive radial velocity in the Belle II coordinate system from those traveling in the opposite direction. Finally, we present a novel method of discriminating beam–gas interactions from Touschek beam losses that can eliminate the need for dedicated accelerator runs for background measurements. This method is still statistics-limited. However, future studies should be able to verify this method, which in turn could lead to neutron background analysis runs symbiotic with normal Belle II operation. The capabilities demonstrated here also suggest that high definition recoil imaging in gas TPCs is applicable to low energy, low-background experiments, such as directional dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of background limitations to ultra-sensitive $\mathrm{LSC}$ counting through $\mathrm{ICP}$-$\mathrm{MS}$ assay of $\mathrm{LSC}$ cocktails

We report the performance of LSC cocktails in ultra-sensitive applications was evaluated. Backgrounds from radioactive contaminations in commercially available and in-house developed liquid scintillation cocktails were measured and compared to the predicted background levels of the ultra-low background liquid scintillation counter. Through the ICP-MS assay of the cocktails and their constituents, potassium impurities in the surfactant component were identified as a significant source of background, potentially limiting the use of LSC counting in ultra-sensitive applications. This work lays the groundwork for future research towards ultrapure LSC cocktails for ultrasensitive LSC counting

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence for ground-state electron capture of K 40

Potassium-40 is a widespread, naturally occurring isotope whose radioactivity impacts estimated geological ages spanning billions of years, nuclear structure theory, and subatomic rare-event searches—including those for dark matter and neutrinoless double-beta decay. The decays of this long-lived isotope must be precisely known for its use as a geochronometer, and to account for its presence in low-background experiments. There are several known decay modes for potassium-40, but a predicted electron-capture decay directly to the ground state of argon-40 has never been observed. The existence of this decay mode impacts several fields, while theoretical predictions span an order of magnitude. Here we report on the first, successful observation of this rare decay mode, obtained by the KDK (potassium decay) Collaboration using a novel combination of a low-threshold x-ray detector surrounded by a tonne-scale, high-efficiency γ -ray tagger at Oak Ridge National Laboratory. A blinded analysis reveals a distinctly nonzero ratio of intensities of ground-state electron-captures ( I EC 0 ) over excited-state ones ( I EC * ) of I EC 0 / I EC * = 0.0095 ± stat 0.0022 ± sys 0.0010 (68% CL), with the null hypothesis rejected at 4 σ [Stukel et al. , Phys. Rev. Lett. 131 , 052503 (2023) ]. In terms of branching ratio, this unambiguous signal yields I EC 0 = 0.098 % ± stat 0.023 % ± sys 0.010 % , roughly half of the commonly used prediction. This first observation of a third-forbidden unique electron capture improves our understanding of low-energy backgrounds in dark-matter searches and has implications for nuclear-structure calculations. For example, a shell-model based theoretical estimate for the neutrinoless double-beta decay half-life of calcium-48 is increased by a factor of 7 - 2 + 3 . Our nonzero measurement shifts geochronological ages by up to a percent; implications are illustrated for Earth and solar system chronologies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Artificial neural network based isotopic analysis of airborne radioactivity measurement for radiological incident detection

Responders need tools to rapidly detect and identify airborne alpha radioactivity during consequence management scenarios. Traditional continuous air monitor systems used for this purpose compute the net counts in various energy windows to determine the presence of specified isotopes, such as 235U, 239Pu, and 241Am. These calculations rely on having a well-calibrated detector, which is challenging in low-background environments. Here an alternative approach of using artificial neural networks to classify alpha spectra is presented. Two network architectures, fully connected and convolutional networks, were trained to classify alpha spectra into four categories: background and background plus the three isotopes above. Sources were injected into measured background at various fractions of the derived response level (DRL) corresponding to early-phase Protective Action Guides. The convolutional network identifies all sources at 1% of the DRL with average probability of detection of 95% and false alarm probability of 1%. Further, the network identifies sources ranging between 0.25% and 1% of the DRL with higher than 80% probability of detection and lower than 7% false alarm probability. Most significantly, the network performance improves in low-count background conditions, increasing its minimum probability of detection to 93% and reducing the false alarm probabilities to lower than 0.25%. These results show that, once trained on datasets representing a range of detection scenarios, artificial neural networks can accurately identify alpha isotopes of interest without the need for detector calibration.

Woldegiorgis, Surafel F.↗

An integrated online radioassay data storage and analytics tool for nEXO

Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. Furthermore, this paper describes this database application, explains how it functions, and discusses how it streamlines the design of the experiment.

47 OTHER INSTRUMENTATION↗

Underground Experiments [Slides]

The aim of the Low Background Radiation Experiment (LBRE) has been to clarify the effects that low levels of radiation have on biological systems. Experiments started in 2009 and continue each summer. Research for the potential performance of a repository for heat-generating waste in bedded salt. A full-scale prototype heater canister was designed and fabricated in fiscal year 2014 to demonstrate the ability of the prototype canister-heater to operate under realistic conditions for performance and reliability. Testing in the underground started in September 2017 and is ongoing. Currently, there is no power to this experiment due to maintenance in the underground.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Gamma Spectrometry Code Rodeo for Uranium Enrichment—FY 2022 Report

In the first two quarters of FY22, data acquisition continued at ORNL and LLNL using uranium sources of known enrichments. This was an FY21 task which could not be completed in FY21 because of problems encountered with the ORNL M400 CZT in Q4 of FY21, and the subsequent repairs. The detector was received back from H3D in the first of September 2021 , and the measurements resumed . Measurements using the repaired detector were completed in Q1 of FY22. The spectra were distributed by ORNL to the analyzing labs. Analysis results were received in Q2 of FY2022. The results from the various codes were intercompared and an ANOVA analysis was performed. Random and systematic uncertainties were established for each code. The ANOVA results and discussions were included in a revised version of FY21Annual Report issued in March 2022. A paper was presented at the INMM 2022Annual Conference, with the analysis results from the various isotopic codes, and the ANOVA table with random and systematic uncertainties. The Project Work Plan (PWP) for FY22 included a task to perform field testing of the M400 CZT and the analysis codes using UF 6 cylinder measurements at the Framatome Fuel Fabrication Facility in Richland, WA. PNNL was the lead for the field testing task. PNNL drafted a Field Test Plan, and refined it based on comments received from the team. PNNL coordinated with Framatome facility, the logistics of carrying out the field testing . A collimator and shield made out of TFlex (tungsten impregnated polymer) was designed and professionally manufactured. The collimators were used in the field test measurements. The measurements at Framatome were completed on April 21, 2022. A total of 34 Type 30B cylinders were measured using three M400 detectors (PNNL, LLNL, and ORNL detectors). Measurements using M400 were taken at two locations on the side of each cylinder and from the end-on bottom location. Additionally, HPGe measurements were taken at the end-on location to establish ground truth. Cylinder wall thickness measurements were also made at all three locations. To gain a better understanding of the effect of background from surrounding cylinders, the same five cylinders measured individually in low background locations were measured again in the cylinder storage yards. Due to inclement weather, manufacturer delays, shipping delays, and equipment failure, the measurement campaign spanned twice as long compared to the original timeline. Gamma-ray spectra from M400 and HPGe detectors, along with the cylinder data and photographs were organized and shared with the collaborators for further analysis. Spectra were analyzed by the participating laboratories. FY22 PWP also consists of tasks related to plutonium source measurements, adapting the codes to analyze plutonium spectra, and inter-comparison of the results from various codes. Plutonium spectra are being acquired at LANL, ORNL, and LLNL. LANL, SNL and LLNL are in the process of modifying FRAM, GADRAS, and CZTU, respectively. The plutonium related tasks will be completed in Q2 of FY23.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UNESE Argon-39 Measurement Techniques: Developing an above-ground Argon-39 Measurement Capability

The Underground Nuclear Explosion Signatures Experiment (UNESE) sought to use 37 Ar as a tracer for measuring noble-gas migration in the soil surrounding historic Underground Nuclear Explosions (UNE). One unexpected observation was the presence of the much longer-lived isotope 39 Ar from historic UNEs. Quantifying the activity of 39 Ar proved difficult due to the lack of capability to measure significantly-above-background levels of 39 Ar and a general discomfort to repeatedly expose Ultra-Low-Background Proportional Counters (ULBPCs) to significant radioactivity. Because the whole-air samples collected for the 37 Ar tracer measurement were already being measured on the above-ground argon capability, it was decided to expand that capability to include 39 Ar. This document describes the efforts required to achieve quantitative reporting of the 39 Ar backgrounds measured during experiments at the sites of the historic Barnwell and Disko Elm UNEs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Project 8: Measuring the tritium beta-decay spectrum using Cyclotron Radiation Emission Spectroscopy

Abstract. The goal of the Project 8 experiment is to measure the absolute neutrino mass using tritium beta decays and a new spectroscopic technique, Cyclotron Radiation Emission Spectroscopy (CRES). The first phase of Project 8 demonstrated that CRES could be used to detect single-electron cyclotron radiation and perform precision electron spectroscopy. We are in Phase II of the experiment, performing a 100-day measurement of the endpoint of the tritium spectrum. We will demonstrate the ability to measure the last ~2 keV of the beta-decay spectrum and explore the background rate at energies just above the endpoint; CRES has the potential for extremely low backgrounds. In Phase III we will demonstrate the ability to scale up the volume of the experiment. In Phase IV we will switch the source from molecular tritium to atomic tritium, which will avoid systematic uncertainties from the final states of the molecule. I will present the current status of Project 8 Phase II and the plans for Phases III and IV.

Oblath, Noah↗

Background identification in cryogenic calorimeters through $\alpha -\alpha$ delayed coincidences

Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $\alpha -\alpha$ delayed coincidences in 232 Th and 238 U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the $\alpha$ decay position.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Maximizing quantum enhancement in axion dark matter experiments

We provide a comprehensive comparison of linear amplifiers and microwave photon counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1 and 30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies (𝜈 >5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the overcoupling regime, up to 𝛽 ∼10; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Perspectives of lowering CUORE thresholds with Optimum Trigger

CUORE is a cryogenic experiment that focuses on the search of neutrinoless double beta decay in 130Te and it is located at the Gran Sasso National Laboratories. Its detector consists of 988 TeO 2 crystals operating at a base temperature of ~10 mK. It is the first ton-scale bolometric experiment ever realized for this purpose. Thanks to its large target mass and ultra-low background, the CUORE detector is also suitable for the search of other rare phenomena. In particular the low energy part of the spectra is interesting for the detection of WIMP-nuclei scattering reactions. One of the most important requirements to perform these studies is represented by the achievement of a stable energy threshold lower than 10 keV. Here, the CUORE capability to accomplish this purpose using a low energy software trigger will be presented and described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multielectrode electrochemical cell for in situ structural characterization of amorphous thin-film catalysts using high-energy X-ray scattering

A multielectrode-based electrochemical cell allows the structural characterization of an amorphous thin-film water oxidation catalyst under various electrochemical potentials using high-energy X-ray scattering and atomic pair distribution function (PDF) techniques. A multielectrode with five electrodes provides a sufficiently low background signal to enable high-energy X-ray scattering (HEXS) measurements and amplifies the extremely low HEXS signals from samples for high-resolution PDF analysis of in situ data from thin-film catalysts. Glassy carbon (GC) creates a relatively low intensity HEXS pattern and is used as a working electrode. Instead of a three-dimensional (3D) porous electrode architecture, the flat geometry of the electrode enables various deposition techniques to be used for the preparation of a highly conductive metal oxide layer. PDF analysis demonstrates high spatial resolution for a 230 nm thick amorphous iridium oxide film deposited on two roughened 60 µm thick GC electrodes. The PDF analysis resolves the domain size and distinguishes changes in fine structure which are directly correlated with the structure and function of the catalysts. In conclusion, the results bring the opportunity to analyze the structure of nanometre-scale amorphous thin-film catalysts in an electrolyte-compatible and compact 3D-printed electrochemical cell in a three-electrode configuration.

36 MATERIALS SCIENCE↗

Indium as a surfactant: Effects on growth morphology and background impurity in GaN films grown by ammonia-assisted molecular beam epitaxy

We report on the improvement of the surface morphology of c-plane GaN films grown at high growth rates (~1 µm/h) using ammonia molecular beam epitaxy through a series of growth optimizations as well as the introduction of indium as a surfactant. The indium surfactant was expected to help with the adatom mobility and, thus, provide smoother growth surfaces. Through a combination of varying V/III ratios, In flux, and growth temperatures, an optimal condition for surface morphology, characterized by atomic force microscopy, was achieved. At higher Ga fluxes for fast growth rates (~1 µm/h and beam equivalent pressures of ~5 × 10 –7 Torr), higher ammonia flows were necessary to preserve the surface morphology. In addition, indium was an effective surfactant—reducing the roughness and improving the overall surface morphology. However, excessive indium causes the surface morphology to degrade, potentially due to the enhancement of the Ga desorption from the surface as a result of the reaction of indium with ammonia for high indium fluxes. The indium surfactant also resulted in a reduction of background Si impurity concentrations in the film. These effects allow for the growth of thick drift layers with low background dopant concentrations for vertical GaN power devices.

36 MATERIALS SCIENCE↗

Search for Fractionally Charged Particles with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5 cm × 5 cm × 5 cm TeO 2 crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in 130 Te. Unprecedented in size among cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic throughgoing particles. Using the first tonne year of CUORE’s exposure, we perform a search for hypothesized fractionally charged particles (FCPs), which are well-motivated by various standard model extensions and would have suppressed interactions with matter. Across the searched range of charges 𝑒/24−𝑒/2 no excess of FCP candidate tracks is observed over background, setting leading limits on the underground FCP flux with charges 𝑒/24 −𝑒/5 at 90% confidence level. Using the low background environment and segmented geometry of CUORE, we establish the sensitivity of tonne-scale subkelvin detectors to diverse signatures of new physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗