Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase contrast.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Contrasting phase changes of precipitation annual cycle between land and ocean under global warming

The annual cycle of precipitation is a fundamental aspect of the water cycle with global ramification. Climate warming induces a robust phase delay1-5 in zonal mean tropical precipitation concomitant with an amplitude enhancement6-8. Here, we find a large land ocean contrast in the phase response of precipitation annual cycle, with a phase delay over land and a phase advance over ocean as climate warms. The phase delay over land is mainly attributed to the increase in the effective heat capacity of the atmosphere, while the phase advance over ocean is associated with a precipitation shift from land to ocean during the peak rainy season. Through the energetic constraint, this precipitation shift is closely related to the opposite changes in the amplitude of surface temperature annual cycle between land and ocean, both as consequences of basic climate feedback processes under global warming: weakening of the summer trade wind over the tropical ocean increases the surface temperature seasonal amplitude through evaporation, while an increase of the atmospheric effective heat capacity and surface cooling feedback induces opposite temperature amplitude changes over the tropical land. The opposite precipitation phase changes between land and ocean will have myriad implications for terrestrial/marine ecosystems and human activities.

Song, Fengfei↗

Ball Motion and Near-Field Spray Characteristics of a Gasoline Direct Injection Injector using an X-ray Phase-Contrast Imaging Technique under High-Injection Pressures

Here, the purpose of this study is to visualize the ball (needle) motion and near-field spray characteristics of a gasoline direct injection injector under different injection conditions and analyze the effect of the internal structure of the injector on the ball motion, near-field spray velocity, and post-injection process. The injection pressure is set to 10MPa, 20 MPa, and 30 MPa, and the energization duration is fixed at 1.5 ms. An advanced X-ray technique with high transmittance and low scattering, is used to visualize the internal structure and near-field spray characteristics of the injector, which is impossible with general light sources. The ball is found to tilt to the right in the Y-axial direction during stable motion because the driving force of fuel on the ball is larger on the left side owing to the larger distance of the ball from the left wall. In addition, during stable motion, the near-field velocity of a hole with a smaller inlet angle is significantly higher than that of a hole with a larger inlet angle. The hole with a smaller inlet angle display better atomization characteristics during the post-injection process under all values of injection pressure.

47 OTHER INSTRUMENTATION↗

Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources

With its ability to efficiently probe low-Z materials, X-ray phase imaging methods have recently raised high interest in multiple fields from biology and medical applications to high energy density (HED) physics. Initially developed with synchrotron light and X-ray tubes, we present a novel grating based Talbot X-ray deflectometer (TXD) diagnostic that was coupled with laser-generated K-α X-ray sources. The multi-terawatt laser (I > 1 × 10 14 W cm -2 ) was used as a testbed for diagnostic development. It was found that X-ray source chromaticity plays an important role in TXD. Indeed, the broadband spectrum of laser-generated X-ray sources may strongly impact image quality and thus diagnostic performance. We qualified X-ray emission from different laser-produced sources and determined laser, target, and deflectometer parameters that optimize TXD performance. We present the first results of referenceless grating-based X-ray imaging at high-power laser facilities and discuss the implications of this new development in HED research.

47 OTHER INSTRUMENTATION↗

Design considerations for an ultrahigh-bandwidth Phase Contrast Imaging system applied to fusion grade devices

Abstract The PCI diagnostic is an internal reference interferometer that creates an image of absolutely calibrated electron density fluctuations integrated along the line of sight of the probing light beam. While conventional PCI diagnostics installed on fusion experiments worldwide employ light of wavelength equal to 10.59 μm, the same system using light at 1.55 μm wavelength would extend the spectral response in wave-number and frequency by factors of seven and over one hundred, respectively, thereby potentially providing quantitative measurements of the internal structure of density perturbations induced by either turbulent or radio-frequency waves, simultaneously covering ion to electron gyro-radius scales up to the GHz frequency region. Based on a previously developed 1.55 μm PCI prototype system, constraints to the design for such a diagnostic in fusion grade devices are presented and compared to those faced with the conventional method.

Instruments & Instrumentation↗

Neutron Imaging Using Grating Interferometry: Exploiting phase contrast and dark-field imaging for <1μm feature detection in bulk materials (Summary Report)

Radiography is an important non-destructive characterization tool for many LANL missions. Contrast in conventional radiography results from attenuation of the incoming x-ray or neutron beam by the object. Neutrons have a great benefit in detecting light elements (e.g. hydrogen) in the presence of heavier elements and penetrate deeper than X-rays into many materials, but neutron radiography resolution is typically limited to ~50 μm. Cracks, voids, pores and a variety of other features smaller than this resolution are therefore undetectable in attenuation based neutron imaging. However, novel neutron imaging modalities leveraging off of interferometric methods, so-called neutron grating interferometry (NGI), are able to spatially map sub-micron features and interfacial features while also exploiting the neutron’s sensitivity to light elements and isotope specific contrast to enable material characterization otherwise impossible.

36 MATERIALS SCIENCE↗

Electron Energy-Loss Spectroscopy and Differential Phase Contrast Imaging with Active Decision in Multimodal Electron Microscopy: Isotopic detection at the atomic scale

Isotopic engineering provides a powerful route to control phonon behavior in crystalline solids, enabling fundamental studies of lattice dynamics and heat transport at the atomic scale. Here, we directly visualize isotope-dependent phonon propagation in epitaxial Cr 2 O 3 using aberration-corrected scanning transmission electron microscopy (STEM) combined with monochromated, high-energy-resolution electron energy-loss spectroscopy (EELS). Guided by ab initio phonon calculations, we demonstrate that optical phonon modes above 70 meV are predominantly oxygen-derived and exhibit measurable redshifts upon substitution of natural 16 O by enriched 18 O. Spatially resolved vibrational spectrum imaging reveals isotope-enriched tracer layers within Cr 2 O 3 thin films, correlating isotope concentration with phonon intensity variations and vibrational energy shifts. At the nanometer and atomic scales, vibrational EELS mapping uncovers coherent phonon propagation across isotopic interfaces, consistent with theoretical phonon density of states and dispersion relations. These results establish vibrational EELS as a quantitative probe for isotope-dependent phonon transport in materials, opening new possibilities for studying energy dissipation and lattice dynamics.

36 MATERIALS SCIENCE↗