Search NASA⌕ Search

SEARCH · Search NASA

Results for “total dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Radioidone Event of March 2023

Internal Dosimetry (RP-SVS) will send each affected employee a dose assessment based on their thyroid measurement results. Affected employees will be kept apprised of their dose assessment with an issued progress report. Included in the progress report is an upper limit on the committed effective dose (total dose incurred before the radioiodine leaves the body). Final dose results are expected to be reported within about two weeks of the initial thyroid measurement. You can contact Deepesh Poudel (505-665-1798), John Klumpp (505-667-0325), or Sara Dumit (505-665-4095) if you have any questions about the status of your dose assessment

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Recovery of damage in rad-hard MOS devices during and after irradiation by electrons, protons, alphas, and gamma rays

This paper reports on the recovery properties of rad-hard MOS devices during and after irradiation by electrons, protons, alphas, and gamma rays. The results indicated that complex recovery properties controlled the damage sensitivities of the tested parts. The results also indicated that damage sensitivities depended on dose rate, total dose, supply bias, gate bias, transistor type, radiation source, and particle energy. The complex nature of these dependencies make interpretation of LSI device performance in space (exposure to entire electron and proton spectra) difficult, if not impossible, without respective ground tests and analyses. Complete recovery of n-channel shifts was observed, in some cases within hours after irradiation, with equilibrium values of threshold voltages greater than their pre-irradiation values. This effect depended on total dose, radiation source, and gate bias during exposure. In contrast, the p-channel shifts recovered only 20 percent within 30 days after irradiation.

Brucker, G. J.↗

A review of dose rate dependent effects of total ionizing dose /TID/ irradiations

The basic effects of ionizing radiation are summarized. The problem of the existence of a true dose rate effect is examined. Consideration is given to the nature of long term annealing, which is sometimes manifested as an 'apparent' dose rate effect. Both analytical and experimental work is considered and the results are related to practical testing requirements.

Nichols, D. K.↗

Radiation response issues for infrared detectors

Researchers describe the most important radiation response issues for infrared detectors. In general, the two key degradation mechanisms in infrared detectors are the noise produced by exposure to a flux of ionizing particles (e.g.; trapped electronics and protons, debris gammas and electrons, radioactive decay of neutron-activated materials) and permanent damage produced by exposure to total dose. Total-dose-induced damage is most often the result of charge trapping in insulators or at interfaces. Exposure to short pulses of ionization (e.g.; prompt x rays or gammas, delayed gammas) will cause detector upset. However, this upset is not important to a sensor unless the recovery time is too long. A few detector technologies are vulnerable to neutron-induced displacement damage, but fortunately most are not. Researchers compare the responses of the new technologies with those of the mainstream technologies of PV HgCdTe and IBC Si:As. One important reason for this comparison is to note where some of the newer technologies have the potential to provide significantly improved radiation hardness compared with that of the mainstream technologies, and thus to provide greater motivation for the pursuit of these technologies.

Kalma, Arne H.↗

Total Ionizing Dose Effects on High Resolution (12-/14-bit) Analog-to-Digital Converters

This paper reports total dose radiation test results for high resolution 12-/14-bit A/D converters. Small changes in internal components can cause these devices to fail their specifications at relatively low total dose levels. Degradation of signal-to-noise ratio becomes increasingly importamt for high accuracy converters. Rebound effects in the thick-oxide MOS devices causes these responses to be different at low and high dose rates, which is a major concern for space applications.

radiation ionizing analog-to-digital converters MO↗

AD8065 Voltage Feedback Amplifier’s Total Ionizing Dose Characterization Report

The purpose of this testing was to characterize Analog Devices’ AD8065 FastFET amplifier for low-dose rate (LDR) total ionizing dose (TID) response based on the Lucy project requirements and will be used on the L’ORRI instrument being built by Johns Hopkins University Applied Physics Lab. The AD8065 is a voltage feedback amplifier with FET inputs developed with the proprietary eXtra Fast Complementary Bipolar (XFCB) process. The amplifier boasts low noise operation and very high input impedance with a wide supply voltage range.

Megan Casey↗

LTC1877 High Efficiency Regulator Total Ionizing Dose Test Report

This report presents total ionizing dose evaluation data for the Linear Technology Corporation LTC1877 high efficiency monolithic synchronous step-down regulator. Data sheet parameters were tracked as a function of ionizing dose up to a total of 20 krad(SiO2). Control devices were also used.

total ionizing dose (TID)↗

Second Target Station (STS) Project: Analysis of Bunker Shielding–Preliminary Design

At the Department of Energy’s Oak Ridge National Laboratory, the Second Target Station (STS) beamline sources for preliminary design have been used to perform a shielding analysis of the bunker. The simulations in this report used the ST11 beamline source, primarily the ST11 neutron source, because that source provides conservative prompt total dose rate estimates for all beamlines. Prompt total dose rates (i.e., neutron plus photon dose rates when the beam is on) were calculated on top of the bunker roof, outside the bunker wall, and in the basement below the bunker and instrument floor. Design changes were made to ensure the prompt total dose rate in these areas does not exceed 0.25 mrem/h. This report documents the required shielding thicknesses to meet this dose rate limit. There is one exception to this: for a combination of open and closed beamlines, the prompt total dose rate outside the bunker across from the closed beamline, where there is less shielding due to the lack of beamline shielding, slightly exceeds 0.25 mrem/h. A future analysis will document the shielding modifications required to reduce the calculated prompt total dose rates for this configuration to less than 0.25 mrem/h once more details regarding the STS high density concrete density and composition are known. Finally, prompt total dose rates inside the bunker were simulated. The results of this simulation show that the majority of prompt total dose rate in the bunker is due to neutrons, and a few percent of the total is caused by secondary photons created by the neutrons. The contribution to prompt total dose rate inside the bunker by the primary photons that enter each beamline from the target/moderator area is at least two orders of magnitude less than the neutron contribution. This means prompt total dose rate contributions due to primary photons inside and outside the bunker can be neglected.

42 ENGINEERING↗

U309 N-Channel Silicon Junction Field Effect Transistor Total Ionizing Dose Characterization Report

The purpose of this testing was to characterize the InterFET Corporation U309 for total dose response. This test shall serve as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. The U309 is a discrete Junction Field Effect Transistor (JFET). High dose rate (HDR) irradiations were performed in this test so that the device susceptibility to Total Ionizing Dose (TID) could be determined.

Total Ionizing Dose (TID)↗

Total Ionizing Dose Effects on Voltage-to-Frequency Converters

This paper discusses total dose effects on voltage-to-frequency converters which impose different requirements on internal circuitry, and are also very high-precision devices (for example, linearity is typically specified between 0.002 and 0.05%).

low dose rate (LDR) Voltage-to-Frequency Converter↗

Avalanche ASV016204 (Pre-Production Samples) 40nm MRAM Total Ionizing Dose Test Report

The purpose of this test was to characterize the Avalanche Technology ASV016204’s total dose response. In the test, the device was exposed to high dose rate (HDR) irradiations using gamma radiation. Device functionality (in terms of memory cell upsets and read/write ability) as well as power supply currents during various modes of operations were recorded.

Total Ionizing Dose (TID)↗