Search NASASearch

SEARCH · Search NASA

Results for “47 OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

710 records · Page 40

Constraining primordial non-Gaussianity from DESI DR1 quasars and Planck PR4 CMB lensing

We present the first measurement of local-type primordial non-Gaussianity from the cross-correlation between 1.2 million spectroscopically confirmed quasars from the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI) and the Planck PR4 CMB lensing reconstructions. The analysis is performed in three tomographic redshift bins covering 0.8 < z < 3.5, covering a sky fraction of ∼20%. We adopt a catalog-based pseudo-C ℓ estimator and apply linear imaging weights validated on noiseless mocks. Compared to previous analyses using photometric quasar samples, our results benefit from the high purity of the DESI spectroscopic sample, the reduced noise of PR4 lensing, and the absence of excess large-scale power in the spectroscopic quasar auto-correlation. Fitting simultaneously for the non-Gaussianity parameter f NL and the linear bias amplitude in each redshift bin, we obtain f NL = 2 +28 -34 for a response parameter p = 1.6, and f NL = 6 +20 -24 for p = 1.0. These results improve the constraints on f NL by ∼35% compared to the previous analysis based on the Legacy Imaging Survey DR9. Additionally, we derive an optimal weighting scheme to maximize the constraining power. In this case, and assuming p = 1.6, we obtain f NL = 19 +25 -31 . Our results demonstrate the statistical power of DESI quasars for probing inflationary physics, and highlight the promise of future DESI data releases.

cosmological parameters from CMBR

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics

Search for New Physics via Low-Energy Electron Recoils with a 4.2 Tonne-Year Exposure from the LZ Experiment

We report results from searches for new physics models through electron recoils using data collected by the LUX-ZEPLIN experiment during its first two science runs, with a total exposure of 4.2 tonne−years. The observed data are consistent with a background-only hypothesis. Constraints are derived for electromagnetic interactions of solar neutrinos, solar axionlike particles (ALPs), mirror dark matter, and the absorption of bosonic dark matter candidates. The inverse Primakoff process for 57 Fe deexcitation solar ALPs is considered for the first time. These results represent the most stringent constraints to date on keV-scale Primakoff and 57 Fe solar ALPs, bosonic dark matter, mirror dark matter, and neutrino millicharge, while remaining competitive for the other signal models investigated.

Axion-like particles

Weak Lensing Mass Calibration of the ACT DR5 Galaxy Clusters with the DES Year 3 Weak Lensing Data

We use weak gravitational lensing measurements from Year 3 Dark Energy Survey data to calibrate the masses of 443 galaxy clusters selected via the Sunyaev-Zel'dovich effect from Atacama Cosmology Telescope Data Release 5 maps of the cosmic microwave background. We incorporate redshift and SZ measurements for individual clusters into a hierarchical model for the stacked lensing signals and perform Bayesian analyses to constrain the hydrostatic mass bias of the clusters. Our treatment of systematic uncertainties includes a prescription for measuring and accounting for the weak lensing boost factor, consideration of a miscentering effect, as well as marginalization over uncertainties in the source galaxy photometric redshift distributions and shear calibration. The resultant constraints on the normalization of the mass-observable relation have a precision of approximately 7%, with the mean WL halo mass of M $_{500c}$ = 5.4 × 10$^{14}$ M $_{⊙}$. We measure the bias between the true cluster mass and the mass estimated from the SZ signal based on an X-ray-calibrated scaling relation assuming hydrostatic equilibrium, to be 1 - b = 0.74$^{+0.06}$ $_{-0.05}$ over the full sample. When splitting the clusters into high (z = 0.43-0.70) and low (z = 0.15-0.43) redshift bins, we measure 1 - b = 0.58$^{+0.06}$ $_{-0.05}$ and 0.81$^{+0.08}$ $_{-0.06}$, respectively. When introducing additional freedom in redshift and mass to the hydrostatic bias model, we find that 1 - b decreases with redshift (with the power law of -1.8$^{+0.5}$ $_{-0.6}$, 99.95% confidence), consistent with findings from other recent studies, while we do not find any significant trend in mass. We also demonstrate that our result is robust against various systematics such as a scale cut, priors on baryonic and miscentering parameters, and degree of scatter in mass-observable relation. The weak-lensing mass calibration presented in this study will be a useful tool for using the ACT clusters as probes of astrophysics, and as a step towards using their abundance as a cosmological probe.

Shin, T. [Carnegie Mellon U.] (ORCID:0000000263895

Reconstruction of cosmic-ray muon events with CUORE

We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta (0vββ) decay, leveraging the segmentation of the detector. Due to the slow time response of the detector, time-of-flight estimation is not feasible. Therefore, the track reconstruction is performed using a multi-objective optimization algorithm that relies on geometrical information from the detector as a whole. We measure the integral flux of cosmic-ray muons underground at the Laboratori Nazionali del Gran Sasso, and find our value to be in good agreement with other experiments that have performed a similar measurement. To our knowledge, this work represents the first demonstration of 3D particle tracking and reconstruction of through-going muons with per-event angular determination in a millikelvin cryogenic detector array. The analysis performed for this work will be critical for validating the muon-related background in CUPID, a next-generation 0vββ experiment, and for follow-up studies on detector response and on delayed products induced by cosmic-ray muons.

Adams, D. Q. [University of South Carolina]

Dark Energy Survey Year 6 results: Clustering redshifts and importance sampling of self-organized-maps 𝑛⁡(𝑧) realizations for 3 × 2 ⁢pt samples

This work is part of a series establishing the redshift framework for the 3 × 2 ⁢pt analysis of the Dark Energy Survey Year 6 (DES Y6). For DES Y6, photometric redshift distributions are estimated using self-organizing maps (SOMs), calibrated with spectroscopic and many-band photometric data. To overcome limitations from color-redshift degeneracies and incomplete spectroscopic coverage, we enhance this approach by incorporating clustering-based redshift constraints (clustering-z, or WZ) from angular cross-correlations with BOSS and eBOSS galaxies and eBOSS quasar samples. We define a WZ likelihood and apply importance sampling to a large ensemble of SOM-derived 𝑛⁡(𝑧) realizations, selecting those consistent with the clustering measurements to produce a posterior sample for each lens and source bin. The analysis uses angular scales corresponding to 1.5–5 Mpc to optimize signal-to-noise ratio while mitigating modeling uncertainties and marginalizes over redshift-dependent galaxy bias and other systematics informed by the N-body simulation CARDINAL . While a sparser spectroscopic reference sample limits WZ constraining power at 𝑧 >1.1, particularly for source bins, we demonstrate that combining SOM with WZ improves redshift accuracy and enhances the overall cosmological constraining power of DES Y6. As a result, we estimate an improvement in 𝑆 8 of approximately 10% for cosmic shear and 3 ×2⁢pt analysis, primarily due to the WZ calibration of the source samples.

Cosmological parameters

The Dark Energy Survey supernova program: a reanalysis of cosmology results and evidence for evolving dark energy with an updated Type Ia supernova calibration

We present improved cosmological constraints from a re-analysis of the Dark Energy Survey (DES) 5-year sample of Type Ia supernovae (DES-SN5YR). This re-analysis includes an improved photometric cross-calibration, recent white dwarf observations to cross-calibrate between DES and low-redshift surveys, retraining the salt3 light-curve model and fixing a numerical approximation in the host-galaxy colour law. Our fully recalibrated sample, which we call DES-Dovekie, comprises ~1600 likely Type Ia SNe from DES and ~200 low-redshift SNe from other surveys. With DES-Dovekie, we obtain Ω m = 0.330 ± 0.015 in flat Lambda-cold dark matter (⁠ΛCDM) which changes Ω m by –0.022 compared to DES-SN5YR. Combining DES-Dovekie with cosmic microwave background data from Planck, Atacama Cosmology Telescope, and South Pole Telescope and the DESI DR2 measurements in a flat CDM cosmology, we find ω 0 = –0.803 ± 0.054 and ω a = –0.72 ± 0.21⁠. Our results hold a significance of 3.2σ, reduced from 4.2σ for DES-SN5YR, to reject the null hypothesis that the data are compatible with the cosmological constant. This significance is equivalent to a Bayesian model preference odds of approximately 5:1 in favour of the flat ω 0 ω a CDM model. Using generally accepted thresholds for model preference, our updated data exhibits only a weak preference for evolving dark energy.

dark energy