Search NASASearch

SEARCH · Search NASA

Results for “Distributed Data Parallelism”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

925 records · Page 44

Thermal Neutral Format Based on the Step Technology

The exchange of models is one of the most serious problems currently encountered in the practice of spacecraft thermal analysis. Essentially, the problem originates in the diversity of computing environments that are used across different sites, and the consequent proliferation of native tool formats. Furthermore, increasing pressure to reduce the development's life cycle time has originated a growing interest in the so-called spacecraft concurrent engineering. In this context, the realization of the interdependencies between different disciplines and the proper communication between them become critical issues. The use of a neutral format represents a step forward in addressing these problems. Such a means of communication is adopted by consensus. A neutral format is not directly tied to any specific tool and it is kept under stringent change control. Currently, most of the groups promoting exchange formats are contributing with their experience to STEP, the Standard for Exchange of Product Model Data, which is being developed under the auspices of the International Standards Organization (ISO 10303). This paper presents the different efforts made in Europe to provide the spacecraft thermal analysis community with a Thermal Neutral Format (TNF) based on STEP. Following an introduction with some background information, the paper presents the characteristics of the STEP standard. Later, the first efforts to produce a STEP Spacecraft Thermal Application Protocol are described. Finally, the paper presents the currently harmonized European activities that follow up and extend earlier work on the area.

P Planas Almazan

Technoeconomic Analysis Round Robin of a Retrofit of the Ivanpah Concentrating Solar Plant with a Molten-Salt System with Thermal Energy Storage

While the fidelity of technoeconomic analysis (TEA) models for concentrating solar thermal systems has improved in recent years, there is a lack of consensus on the specific inputs used to forecast performance of a newly built tower system due to a lack of validations and post-mortems available to the public. This effort is a joint initiative between multiple international organizations to validate and compare their TEA models. The specific case study is a proposed retrofit of one unit of the Ivanpah Solar Energy Generating System to include molten-salt storage, replacing the steam generation system with a molten-salt receiver, salt-to-steam heat exchanger train, and new balance of plant while keeping the existing steam turbine, solar field, and interconnection in place, using plant data for calibration. This manuscript discusses several of the agreed-upon assumptions for this study as well as a preliminary analysis from prior work that motivates the study.

14 SOLAR ENERGY

In-Situ Visualization of a Growing Brittle Crack in Aluminum Oxynitride Using Synchrotron X-Rays and the Double-Cleavage Drilled Compression Geometry

Brittle fracture is difficult to study in situ due to the speed of a growing crack and the often-catastrophic nature of failure in brittle materials. As a result, the influence of microstructural considerations, such as orientation, grain boundary locations, and strain field, on the crack path remains poorly understood. Presented in this study is a method addressing this knowledge gap, which utilizes the double-cleavage drilled compression geometry to achieve quasi-stable fracture in aluminum oxynitride (AlON). Synchrotron X-ray micro-computed tomography is used to characterize the crack shape and length, while high-energy diffraction microscopy provides information on the strains, orientations, and shapes of grains in the microstructure surrounding the crack tip. During testing, the crack grew in discrete and irregular jumps while the fracture toughness falls within reported ranges. The crack in AlON is found to have no greater tendency to crack intergranularly as compared to transgranularly, and grains which are cracked transgranularly do not display a trend in orientation or stress when compared to those around which the crack followed a grain boundary. The high resolution of the crack path and microstructural data provides a path forward for modeling and understanding 3D brittle fracture.

Gorske, Sara F.

Erosion Results of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4)

Polymers and other oxidizable materials on the exterior of spacecraft in the low Earth orbit (LEO) space environment can be eroded from reaction with atomic oxygen (AO). Therefore, in order to design durable spacecraft it is important to know the extent of erosion that will occur during a mission. This can be determined by knowing the LEO AO erosion yield, E y (volume loss per incident oxygen atom), of materials susceptible to AO reaction. In addition, recent flight experiments have shown that the AO E y can vary with the AO fluence and/or solar exposure. Therefore, obtaining AO E y data for materials flown on various spaceflight missions is important. NASA Glenn Research Center has flown numerous experiments as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS) to characterize the LEO E y of polymers, composites, protective coatings, and other spacecraft materials. Recently, four Glenn experiments with 365 flight (F) samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Although each experiment had numerous sample objectives, the primary objective was to determine the LEO AO E y of various spacecraft materials as a function of solar irradiation and AO fluence. This paper provides a summary of the erosion data for the PCE 1-4 AO E y samples. The AO E y for 150 samples flown in either the LEO ram, wake, zenith or nadir directions are provided. The AO ram fluence varied from 2.97×10 20 atoms/cm 2 after 0.89 years of direct space exposure (with relatively high levels of Si contamination) on MISSE 12 to 3.93×10 20 atoms/cm 2 after 1.17 years of direct space exposure on MISSE-10. The ram AO E y values for uncoated polymers range from 3.81×10 –25 cm 3 /atom for polytetrafluoroethylene (M9R-C20 F) exposed to an AO fluence of 3.44×10 20 atoms/cm 2 on MISSE-9 to 4.43×10 –23 cm 3 /atom for AO etched low density polyimide aerogel (M12R-C21 F) exposed to an AO fluence of 2.97×10 21 atoms/cm 2 on MISSE-12. Because of the low AO fluence and relatively high Si contamination, a number of PCE-3 wake samples experienced mass gain. Thus, AO E y values are not provided for these samples. Although there are calculated AO E y values for the zenith, wake and nadir samples, the ram AO E y for a particular material is a more reliable value in terms of AO exposure because the zenith, wake and nadir directions were exposed to either no or very little AO fluence and thus other space environmental factors (i.e. vacuum, thermal extremes and thermal cycling, and/or various types of radiation) are responsible for the mass loss.

Erosion yield

ISS Radiator Face Sheet Anomaly Investigation and Return to Function

Maintaining sufficient heat rejection on the International Space Station (ISS) is critical to the function of the Low-Earth Orbit station. The External Active Thermal Control System (EATCS) rejects the excess heat generated by the US On-Orbit Segment (USOS) modules. The system uses single-phase liquid ammonia to collect the heat and reject it to six radiators (three on the Starboard side, three on the Port side). Each radiator is made up of eight panels. In September 2008, imagery of the Starboard radiators was conducted and showed one of the panels’ face sheets had peeled up from the internal honeycomb core structure. Out of an abundance of caution, the radiator was isolated from the rest of the EATCS and the ammonia was vented to space. Since the radiator was vented, periodic imagery of all radiator panels was taken to monitor any changes in the face sheet and inspect for other radiator anomalies. In January 2025, after years of trending and inspections, the radiator was reintegrated into the system to increase heat rejection capabilities. This paper will document the multi-year investigation that took place to determine root cause and mitigations implemented to reduce risk to the system. A summary of the data since the investigation will show rationale for reintegrating the radiator even with the damaged panel. The goal of the paper is to document the investigation for historical purposes and provide future programs with findings discovered during the investigation.

Aaron Rodriguez

ISS Radiator Face Sheet Anomaly Investigation and Return to Function

Maintaining sufficient heat rejection on the International Space Station (ISS) is critical to the function of the Low-Earth Orbit station. The External Active Thermal Control System (EATCS) rejects the excess heat generated by the US On-Orbit Segment (USOS) modules. The system uses single-phase liquid ammonia to collect the heat and reject it to six radiators (three on the Starboard side, three on the Port side). Each radiator is made up of eight panels. In September 2008, imagery of the Starboard radiators was conducted and showed one of the panels’ face sheets had peeled up from the internal honeycomb core structure. Out of an abundance of caution, the radiator was isolated from the rest of the EATCS and the ammonia was vented to space. Since the radiator was vented, periodic imagery of all radiator panels was taken to monitor any changes in the face sheet and inspect for other radiator anomalies. In January 2025, after years of trending and inspections, the radiator was reintegrated into the system to increase heat rejection capabilities. This paper will document the multi-year investigation that took place to determine root cause and mitigations implemented to reduce risk to the system. A summary of the data since the investigation will show rationale for reintegrating the radiator even with the damaged panel. The goal of the paper is to document the investigation for historical purposes and provide future programs with findings discovered during the investigation.

Aaron Rodriguez

Predicting Atomistic Transitions with Transformers

Accurate knowledge of the atomistic transition pathways in materials and material surfaces is crucial for many material science problems. However, conventional simulation techniques used to find these transitions are extremely computationally intensive. Even with large-scale, accelerated material simulations, the computational cost constrains the applicable domain in practice. Machine learning models, with the potential to learn the complex emergent behaviors governing atomistic transitions as a fast surrogate model, have great promise to predict transitions with a vastly reduced computational cost. Here, we demonstrate how transformers can be trained to predict atomistic transitions in nano-clusters. We show how we evaluate physical validity of the predictions and how a multitude of additional, different microstates can be generated by slightly varying the data provided to the model.

36 MATERIALS SCIENCE

Elastic-plastic models for multi-site damage

This paper presents recent developments in advanced analysis methods for the computation of stress site damage. The method of solution is based on the p-version of the finite element method. Its implementation was designed to permit extraction of linear stress intensity factors using a superconvergent extraction method (known as the contour integral method) and evaluation of the J-integral following an elastic-plastic analysis. Coarse meshes are adequate for obtaining accurate results supported by p-convergence data. The elastic-plastic analysis is based on the deformation theory of plasticity and the von Mises yield criterion. The model problem consists of an aluminum plate with six equally spaced holes and a crack emanating from each hole. The cracks are of different sizes. The panel is subjected to a remote tensile load. Experimental results are available for the panel. The plasticity analysis provided the same limit load as the experimentally determined load. The results of elastic-plastic analysis were compared with the results of linear elastic analysis in an effort to evaluate how plastic zone sizes influence the crack growth rates. The onset of net-section yielding was determined also. The results show that crack growth rate is accelerated by the presence of adjacent damage, and the critical crack size is shorter when the effects of plasticity are taken into consideration. This work also addresses the effects of alternative stress-strain laws: The elastic-ideally-plastic material model is compared against the Ramberg-Osgood model.

Actis, Ricardo L.

Robust Biaxial Anisotropy and Switchable Néel Vectors in LaFeO 3 Epitaxial Films

Antiferromagnets with highly stable but switchable Néel vectors are desired for antiferromagnetic spintronics with ultrafast speed and terahertz frequencies. Electrical switching of antiferromagnetic insulators has been demonstrated using binary antiferromagnets, while large families of complex antiferromagnets such as perovskites are largely unexplored. Here, we show that epitaxial LaFeO 3 thin films on SrTiO 3 (001) exhibit clear, robust biaxial anisotropy with a spin-flop field of a few tesla. Angular-dependent spin-Hall magnetoresistance (SMR) characterizations of Pt/LaFeO 3 bilayers with the current channel along SrTiO 3 [100] and [110] reveal distinct, intriguing shapes and field dependence. Simulations using a macrospin model accurately describe the main behavior and fine features of the SMR data from which key antiferromagnetic parameters are extracted. Furthermore, remanent SMR measurement confirms the high fidelity of the Néel vector along either easy axis of the biaxial anisotropy, indicating that epitaxial films of LaFeO 3 and potentially other perovskite antiferromagnets offer an attractive platform for antiferromagnetic spintronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Collective excitations and low-energy ionization signatures of relativistic particles in silicon detectors

Abstract Solid-state detectors with a low energy threshold have several applications, including searches of non-relativistic halo dark-matter particles with sub-GeV masses. When searching for relativistic, beyond-the-Standard-Model particles with enhanced cross sections for small energy transfers, a small detector with a low energy threshold may have better sensitivity than a larger detector with a higher energy threshold. In this paper, we calculate the low-energy ionization spectrum from high-velocity particles scattering in a dielectric material. We consider the full material response including the excitation of bulk plasmons. We generalize the energy-loss function to relativistic kinematics, and benchmark existing tools used for halo dark-matter scattering against electron energy-loss spectroscopy data. Compared to calculations commonly used in the literature, such as the Photo-Absorption-Ionization model or the free-electron model, including collective effects shifts the recoil ionization spectrum towards higher energies, typically peaking around 4–6 electron-hole pairs. We apply our results to the three benchmark examples: millicharged particles produced in a beam, neutrinos with a magnetic dipole moment produced in a reactor, and upscattered dark-matter particles. Our results show that the proper inclusion of collective effects typically enhances a detector’s sensitivity to these particles, since detector backgrounds, such as dark counts, peak at lower energies.

Physics

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

Carbon Utilization and Storage Partnership of the Western United States

This technical report documents research conducted under DOE Award No. DE-FE0031837 focused on evaluating the feasibility of carbon capture, utilization, and storage (CCUS) systems in the central and western United States. The project integrated geologic characterization, reservoir simulation, infrastructure modeling, and economic analysis to assess CO₂ storage potential near industrial sources and develop strategies for transport and sequestration. The work included subsurface modeling, risk assessment, monitoring and verification (MRV) planning, and evaluation of regulatory pathways such as EPA Underground Injection Control (UIC) Class VI permitting and IRS 45Q tax credit eligibility. Results demonstrate the viability of multiple storage approaches, including saline formations, enhanced coalbed methane recovery, and basalt mineralization, supported by data-driven workflows and regional analyses. The project also produced permitting templates, technology transfer activities, and stakeholder engagement efforts to support deployment readiness. These findings contribute to the development of scalable, economically viable CCUS systems and provide a repeatable framework for future carbon management projects.

20 FOSSIL-FUELED POWER PLANTS

Reduced Order Models for Liquid Hydrogen Pooling and Vaporization Supported by Experiments

In the event of a leak of liquid hydrogen, a pool can form that vaporizes, disperses, and eventually dilutes to a non-flammable mixture. In this work, we describe fast-running models for the pooling and vaporization of liquid hydrogen in a steady cross-wind. Several pooling models from the literature are compared to solve for the flow and extent of the pool. The size of the pool can serve as the source for a separate dispersion model, which builds upon the existing one-dimensional Gaussian plume model in HyRAM+. Additional terms for the effects of a cross-wind on momentum and entrainment were added so that the model could handle the effects of a cross-wind on a low-speed flow. The models are compared to experimental data on pooling extent and downwind dispersion for steady flow rates of liquid hydrogen in a steady cross-wind. In the two compared experiments, liquid flow rates of 15 and 45 g/s were spilled onto concrete in cross-winds of approximately 1.8 m/s. The rate of growth of the pool and the downwind concentration boundaries are compared to the models, showing good agreement, although additional tuning is needed. These models can contribute to the advancement of codes and standards for liquid hydrogen systems.

dispersion

Insights into the thermo-hydraulic properties of compacted MX80 bentonite during hydration under elevated temperature

In high-level radioactive waste geological repositories, compacted bentonite undergoes coupled thermo-hydraulic processes due to heat released from a central waste canister and groundwater imbibition from the surrounding host rock. An understanding of these processes is essential for long-term simulations of radionuclide migration and canister corrosion, which requires an understanding of temperature effects on the coupled thermo-hydraulic properties governing these processes. In this study, a tank-scale radial infiltration test was used to investigate water imbibition processes in compacted bentonite under a central heater temperature of 200 °C that simulates high thermal gradients in a repository. Interpretation of this test focuses on evaluation of the liquid water wetting front during hydration and the interpretation of the temperature-dependent transient soil water retention curve (SWRC), thermal conductivity function (TCF), and hydraulic conductivity function (HCF). The SWRC during imbibition follows a temperature-dependent wetting path. Temperature effects on the hydraulic conductivity of bentonite in saturated conditions had the greatest effect on the shape of the HCF, with minimal temperature effects at higher suctions. The transient thermal conductivity data matched well with a new TCF linked with the SWRC shape. Although the bentonite layer was restrained, local deformations during hydration may have affected the shapes of the TCF and HCF.

Engineering

Generalizable Web User Interface for Scalable and Streamlined Deployment of Building Energy Management Systems in Small and Medium-Sized Commercial Buildings

Small and medium-sized commercial buildings (SMCBs) comprise 94% of US commercial buildings yet face significant barriers to implementing building energy management systems despite advances in smart device technology. Existing solutions present critical limitations: cloud-based API solutions simplify deployment but create vendor lock-in constraints; commercial integrated software solutions ensure compatibility via standardized protocols but require substantial cost and technical expertise; open-source IoT platforms offer cost-effective vendor independence but provide insufficient standardized protocol support for commercial building automation. This research presents a generalizable web user interface framework that bridges the gap between evolving smart device capabilities and lagging software infrastructure for SMCBs. The proposed system integrates VOLTTRON open-source middleware with an automated configuration converter that transforms unified specifications written in YAML, a human-readable data-serialization format, into system-specific files, streamlining manual setup processes. The vendor-agnostic architecture supports industry-standard protocols (BACnet and Modbus) and semantic building models while providing adaptive web interfaces that dynamically adjust to various building configurations. Demonstrations through simulation-based testing and a field deployment show automatic interface adaptation across heterogeneous HVAC systems and multizone monitoring. The automated configuration converter also substantially reduces labor-intensive setup.

Chung, Jihoon [ORNL] (ORCID:0000000184880815)

Comparison Testing and Analysis of Braided Cords Constructed from Varying Kevlar Fiber Types

Material advancements move quickly, resulting in material obsolescence issues that require parachute engineers to understand how the material properties change with a material upgrade and if there are expected impacts to overall performance of the parachute. The objective of this test was to measure the elongation of different Kevlar types at both the cord-level and at the yarn-level to determine if a change in Kevlar type impacted parachute performance. An Instron machine with a pin-to-pin connection was used to measure load and displacement time histories for various Kevlar cord and yarn samples in a cyclic load profile. Twenty-four cord samples and twenty-four yarn samples were tested; each sample was cycled five times to the relevant maximum load (either to breaking strength or to the 30% peak load expected in flight). In addition to the Instron measurements, a photogrammetric technique was also implemented to measure elongation of the samples using button targets. Modulus test data shows approximately a 10% difference in elongation between Kevlar 29AP and Kevlar 129, and another 10% difference in elongation between Kevlar 29 and Kevlar 29AP. Although this is a measurable change in modulus, the effect on parachute performance is likely small, particularly for non-primary structure elements of relatively small length. This test campaign provides an example of the type of testing and analysis that parachute engineers could do to understand how material upgrades affect performance of their systems.

Modulus Testing

Prime Time for Model-Predictive Control? Assessing the Technical and Market Readiness of Advanced Controls in Buildings

Despite three decades of extensive research and field testing that have consistently validated the benefits of Model Predictive Control (MPC) in building applications, the technology has seen limited market adoption. This paper evaluates the readiness of MPC for widespread deployment, showcases recent demonstrations and field tests across diverse building types, including residential, small commercial, large commercial, and campus settings. Our results demonstrate that MPC can optimize system operations to achieve load shifting, minimize curtailment of on-site generation, and reduce energy costs by up to 80 %, while maintaining or improving occupant comfort. We also show that MPC can effectively control large assets, such as MW-sized thermal storage systems, and respond to dynamic pricing signals. However, achieving scale remains difficult due to labor-intensive workflows, reliance on a “PhD-in-the-loop” for MPC design and maintenance, susceptibility to fragile data infrastructure, and persistent workforce education and acceptance barriers. To bridge this gap, we outline a transition from bespoke, labor intensive prototypes toward streamlined, segment-targeted deployment strategies that leverage model templates, semantic tools, and generative AI. By automating control configuration and reducing engineering effort, these recommendations provide a pathway for transforming successful research demonstrations into scalable, market ready solutions for MPC-based controls.

Pritoni, Marco