Search NASASearch

SEARCH · Search NASA

Results for “in situ XAFS spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,765 records · Page 44

Photosynthetic capacity is reduced by warming but unaffected by elevated CO2 in seedlings of five boreal tree species

Abstract Increasing atmospheric CO2 concentrations fuel global warming, with boreal regions warming at a faster rate than many other areas. Boreal forests are an important component of the global carbon cycle, yet we have little data on photosynthetic responses of boreal trees to elevated CO2 (EC) and warming. We grew seedlings of 5 widespread North American boreal tree species (from Betula, Larix, Picea, and Pinus) under current (410 ppm) or elevated (750 ppm) CO2 and either ambient (+0 °C) or increased (+4 °C or +8 °C) temperature, then measured photosynthetic traits over a range of leaf temperatures. Our results were generally consistent across species: photosynthetic capacity (maximum rates of Rubisco carboxylation, Vcmax, and electron transport, Jmax) was unaffected by EC but decreased under +8 °C warming. Accordingly, net photosynthesis measured at the growth CO2 concentration (Agrowth) was reduced under warming and increased under EC. The thermal optimum for Agrowth (ToptA) increased by ∼1.8 °C with EC but increased with warming in only two species. In contrast, the activation energies and thermal optima for Vcmax and Jmax, which are used to estimate photosynthesis in Earth System Models, were unaffected by growth environment. There were a few interactions between growth, CO2, and warming. These results suggest increased photosynthesis of widespread boreal tree species under EC may be offset by future reductions in photosynthetic capacity related to warming. We also show that the temperature sensitivities of parameters used to estimate global photosynthesis in large-scale models are generally unaffected by simulated climate change in these species.

Plant Sciences

Optimizing Deep Geothermal Drilling for Energy Sustainability in the Appalachian Basin

This study investigates the geological and geomechanical characteristics of the MIP 1S geothermal well in the Appalachian Basin to optimize drilling and address the wellbore stability issues encountered. Data from well logs, sidewall core analysis, and injection tests were used to derive elastic and rock strength properties, as well as stress and pore pressure profiles. A robust 1D-geomechanical model was developed and validated, correlating strongly with wellbore instability observations. This revealed significant wellbore breakout, widening the diameter from 12 ¼ inches to over 16 inches. Advanced technologies like Cerebro Force™ In-Bit Sensing were used to monitor drilling performance with high accuracy. This technology tracks critical metrics such as bit acceleration, vibration in the x, y, and z directions, Gyro RPM, stick-slip indicators, and bending on the bit. Cerebro Force™ readings identified hole drag caused by poor hole conditions, including friction between the drill string and wellbore walls and the presence of cuttings or debris. This led to higher torque and weight on bit (WOB) readings at the surface compared to downhole measurements, affecting drilling efficiency and wellbore stability. Optimal drilling parameters for future deep geothermal wells were determined based on these findings.

Environmental Sciences & Ecology

A Machine Learning Framework for Error Compensation in Radiative Transfer Calculations

Radiative heat transfer influences the amount of heat flux transferred to the surface of the hypersonic vehicle, which is essential to evaluate the performance of thermal protection systems. The radiative heat flux is found to be computationally prohibitive while accounting for the variation in spatial, angular, and spectral domains. A new methodology has been recently developed to alleviate the cost of computation in the spectral domain by constructing flow-agnostic reduced-order models (ROMs). The developed spectral ROM databases provide grouping strategies that account for non-equilibrium absorption and emission as well as interaction between disparate species due to spectral overlap in associated radiative processes. However, the developed ROMs need to be optimized for a specific combination of interacting gas species and would need to re-calibrated in case individual species are added/omitted. In this work, we use various machine learning (ML) techniques to approximate the radiative intensities determined by a ROM optimized for a specific gas mixture. The ML model relies on the ROM databases developed for a single species which ignores any spectral overlap. Thus, radiation evaluation starts with a simple summation of radiative intensities predicted using these non-calibrated ROMs for the contributing species. The ML framework then provides a correction to account for the interplay in the frequency, i.e., emission of photons by one species and absorption by another, and yields mixture-specific radiation fields. Once trained on the individual ROM databases, the ML framework offers instantaneous corrections that serves as a time/cost effective alternative to the optimization of ROMs for a specific gas mixture. The ML framework is trained on both the high fidelity and ROM evaluated line of sight (LOS) data from Orion, Stardust, and FIRE II cases to obtain a general purpose correction model for earth re-entry scenarios when radiation contributions from both atomic nitrogen and atomic oxygen are considered. A geometric length scale parameter is used in the training process to account for errors introduced in the ROM databases as a consequence of high optical thickness. The efficacy of the ML framework is underscored through extensive analysis of train and test errors with respect to all the re-entry scenarios. The applicability of such an ML framework was further corroborated by embedding it in a state-of-the-art US3D - NERO system for determining the radiative heat flux transferred to the hypersonic vehicle surface.

Radiation

Developing affordable and efficient heating devices for enhanced live cell imaging in confocal microscopy

Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.

Plant Sciences

MRV Challenge 3: velocity and passive scalar comparison in a 3D turbulent flow

The third iteration of a magnetic resonance velocimetry (MRV) challenge comparison activity consisting of 3D flow measurements for a turbulent flow in a water channel moving past centrally positioned cubic obstacles is reported. In this challenge iteration, MRV measurements are coupled with either temperature or concentration measurements to extend the diagnostic utility. Five research teams from around the world conducted the measurements on a single shared apparatus. The water channel included partial elements along the channel sidewalls that varied in height and precluded easy optical accessibility. In addition to a turbulent mainstream flow, a secondary flow entered the channel between the second and third cubic elements from a square injector hole at the channel bottom wall. The injector jet interacts with the mainstream flow and mixes turbulently as it advects downstream. For the selected flow regime and water solutions used as working fluids, the mixing of the higher temperature or concentration through the secondary flow with the mainstream flow satisfies the same dynamics so that both temperature and concentration fields behave as passive scalars and can be directly compared. The measurements are explained in detail by each participating team, and the results are interpolated onto a common grid and compared using line profiles, contour plots, and isosurfaces.

Benson, Mike [ORNL] (ORCID:000000023210116X)

Compatibility of Type 304H Stainless Steel in Static Molten FLiBe for Inertial Confinement Fusion Reactors: Role of Impurities and Redox Control

Molten fluoride salts, such as FLiBe (LiF-BeF2), are promising candidates for tritium breeding and heat transfer in fusion reactors, but corrosion of structural materials remains a major challenge. This study investigates the corrosion behavior of austenitic stainless steel 304H in purified and NiF2-containing FLiBe at 500°C and 600°C, focusing on the effects of impurities and redox control. Exposure to purified FLiBe resulted in the concurrent depletion of Cr, Mn, and Fe, with corrosion at 500 °C dominated by the combined oxide formation and elemental dissolution, while at 600°C elemental depletion was predominant. The addition of a controlled NiF2 impurity significantly accelerated corrosion at both temperatures, demonstrating the sensitivity of 304H to the salt redox state. Beryllium additions were effective in mitigating corrosion for both baseline and NiF2-containing FLiBe; minimal depletion of Cr, Mn, and Fe occurred with Be additions as low as 2.5 mg (147 wppm), and no NiBe intermetallics formed at 5 mg (294 wppm), indicating that small Be inventories can provide substantial protection without deleterious phase formation. Thermodynamic equilibrium and coupled thermodynamic-kinetic analyses at the salt-alloy interface suggested low corrosion rates in systems with limited hydrogen fluoride (HF) generation, highlighting the importance of salt redox control. Estimates for a Be addition rate were calculated for the HYLIFE-II fusion reactor that can mitigate corrosion-induced degradation, assuming complete conversion of tritium to tritium fluoride (TF). Overall, 304H shows reasonable compatibility with FLiBe under optimized redox conditions. These results provide quantitative guidance for material selection and salt management in fusion blanket and heat exchanger systems and motivate validation under flowing, nonisothermal, and irradiated conditions.

Pillai, Rishi [ORNL] (ORCID:0000000243688197)

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD

Tailoring Ion Transport in Li 3‐3y Ho 1+y Cl 6‐x Br x via Transition‐Metal Free Structural Planes and Charge Carrier Distribution

Abstract Localized atomistic disorder in halide‐based solid electrolytes (SEs) can be leveraged to boost Li + mobility. In this study, Li + transport in structurally modified Li 3 HoCl 6 , via Br − introduction and Li + deficiency, is explored. The optimized Li 3‐3 y Ho 1+ y Cl 6‐ x Br x achieves an ionic conductivity of 3.8 mS cm −1 at 25 °C, the highest reported for holmium halide materials. 6,7 Li nuclear magnetic resonance and relaxometry investigations unveil enhanced ion dynamics with bromination, attaining a Li + motional rate neighboring 116 MHz. X‐ray diffraction analyses reveal mixed‐anion‐induced phase transitions with disproportionate octahedral expansions and distortions, creating Ho‐free planes with favorable energetics for Li + migration. Bond valence site energy analysis highlights preferred Li + transport pathways, particularly in structural planes devoid of Ho 3+ blocking effects. Molecular dynamics simulations corroborate enhanced Li + diffusion with Br − introduction into Li 3 HoCl 6 . Li‐Ho electrostatic repulsions in the (001) plane presumably drive Li + diffusion into the Ho‐free (002) layer, enabling rapid intraplanar Li + motion and exchange between the 2d and 4h sites. Li 3‐3 y Ho 1+ y Cl 6‐ x Br x also demonstrates good battery cycling stability. These findings offer valuable insights into the intricate correlations between structure and ion transport and will help guide the design of high‐performance fast ion conductors for all‐solid‐state batteries.

Chemistry

Selective ion transport through hydrated micropores in polymer membranes

Abstract Ion-conducting polymer membranes are essential in many separation processes and electrochemical devices, including electrodialysis 1 , redox flow batteries 2 , fuel cells 3 and electrolysers 4,5 . Controlling ion transport and selectivity in these membranes largely hinges on the manipulation of pore size. Although membrane pore structures can be designed in the dry state 6 , they are redefined upon hydration owing to swelling in electrolyte solutions. Strategies to control pore hydration and a deeper understanding of pore structure evolution are vital for accurate pore size tuning. Here we report polymer membranes containing pendant groups of varying hydrophobicity, strategically positioned near charged groups to regulate their hydration capacity and pore swelling. Modulation of the hydrated micropore size (less than two nanometres) enables direct control over water and ion transport across broad length scales, as quantified by spectroscopic and computational methods. Ion selectivity improves in hydration-restrained pores created by more hydrophobic pendant groups. These highly interconnected ion transport channels, with tuned pore gate sizes, show higher ionic conductivity and orders-of-magnitude lower permeation rates of redox-active species compared with conventional membranes, enabling stable cycling of energy-dense aqueous organic redox flow batteries. This pore size tailoring approach provides a promising avenue to membranes with precisely controlled ionic and molecular transport functions.

Science & Technology - Other Topics

Heat exposure and maternal stress: evidence from the GRAPHS pregnancy cohort in Ghana

Heat exposure has been linked to psychosocial stress, an established antecedent of perinatal depression; however, evidence on heat-related stress during pregnancy in sub-Saharan Africa remains limited. We analyzed psychosocial stress scores and covariate data from the Ghana Randomized Air Pollution and Health Study, linking daily maximum and minimum shaded wet bulb globe temperature (WBGT) metrics to participants’ stress scores derived from the Crisis in Family Systems-Revised Life Events Questionnaire. We evaluated associations using ordinal logistic regression of pregnancy-average and trimester-average exposures and distributed lag non-linear models (DLNMs) to assess time-varying associations across gestation. Higher average maximum WBGT exposure across pregnancy was associated with increased odds of higher psychosocial stress; each 1 °C increase in maximum WBGT was associated with 64% higher odds of belonging to a higher stress category (OR = 1.64; 95% CI = 1.17–2.31; p = 0.0040). In trimester-average models, higher first-trimester maximum WBGT was also associated with higher stress (OR = 1.44; 95% CI = 1.15–1.81; p = 0.0014). DLNMs suggested that relatively cooler daily maximum WBGT values (25th percentile) were associated with decreased odds of stress in early pregnancy, whereas extreme daily maximum WBGT values (99th percentile) showed a pattern consistent with increased odds of stress in mid-to-late gestation. These findings highlight gestational windows in which heat exposure may influence stress, emphasizing the need for further research into underlying mechanisms and effective interventions to protect maternal mental health in heat-vulnerable settings.

White, Lewis [Columbia University] (ORCID:00090005

Thermal Performance of Common Bulk-Fill Cryogenic Insulation Materials in Helium and Hydrogen Background Gases

Maritime shipping of vast quantities of liquid hydrogen (LH 2 ) will be necessary to facilitate a global hydrogen ecosystem; with some studies estimating volumes up to 172,000 m 3 for individual tanker ships, and requiring stationary storage tanks at terminals of 50,000 m 3 to 100,000 m 3 —ten to fifteen times larger than the current largest tank, located at launch pad B at NASA Kennedy Space Center (KSC). Such a radical scale-up will push the boundary of traditional, vacuum-insulated tank designs. Hence, a potential need exists for non-vacuum solutions, which necessitates exploring the thermal performance of insulation materials in non-condensable background gasses at LH 2 temperatures, namely helium and hydrogen. Testing of two bulk-fill insulation materials common to large LH 2 storage tanks, perlite and glass bubbles, in helium and hydrogen was recently conducted by the Cryogenics Test Laboratory at KSC using the Cryostat-100 liquid nitrogen boiloff calorimeter per the ASTM C1774 standard methodology. Effective thermal conductivity (k e ) and heat flux (q) results for each insulation/gas combination are presented across the full vacuum range, as well as thermal profiles through the insulation thickness between 78 K and 293 K.

A M Swanger

Structure of Self-Generated Magnetic Fields in Laser-Solid Interaction from Proton Tomography

Self-generated magnetic fields in laser-solid interactions are experimentally characterized to reveal the 3D location and local field strength, rather than path-integrated quantities, using multi-view proton radiography and tomographic inversion. We infer magnetic fields that extend several millimeters off the target into the hot, rarefied corona, sufficient to strongly magnetize the plasma (Ω e τ e ≫ 1). The data are compared to MHD simulations incorporating recent improvements in modeling magnetic field generation and transport; the volume-averaged coronal field strength and magnetic flux agree to within 25% using a model with magnetic re-localization of transport, although the near-target morphology is not reproduced. This work demonstrates tomographic proton radiography as a valuable tool for investigating magnetic fields in laser-produced plasmas.

High-energy-density plasmas

Ion Transport in Concentrated Crosslinked Solid Polymer Electrolytes

Crosslinking polymers is a common approach to create mechanically stable solid materials such as polymer electrolytes for lithium batteries. In conventional liquid electrolytes, the solvent molecules move freely to accommodate the field-induced motion of ions. However, in crosslinked polymer electrolytes, the rearrangement of polymer segments is constrained by the deformation limits of the network. Herein, we develop a new transport model that accounts for both the formation of concentration gradients and the elasticity of the electrolyte. The elasticity is incorporated by adding an additional term related to the entropy of crosslinked strands to the electrochemical potential of the salt. The resulting Crosslink Model contains two adjustable parameters: $\mathcal{N}$, the average number of monomers in a strand, and λ crit , the maximum strain the network can sustain. These solid-like constraints produce singularities in the governing transport equations, fundamentally altering the concentration profiles. Plateaus in salt concentrations emerge near the electrodes, and network elasticity introduces a strain overpotential. When compared to a Baseline Model ($\mathcal{N}$ → ∞, equivalent to concentrated solution theory), which predicts steepest gradients near the electrodes, both models yield similar current–voltage relationships. Model predictions are compared to electrochemical data for a poly(ethylene oxide)-based crosslinked polymer electrolyte.

Patel, Vivaan [University of California, Berkeley,

Anomalous lattice expansion of bcc Ta in helium-loaded diamond anvil cells

Anomalous lattice expansion of bcc Ta is observed in helium-loaded diamond anvil cell (DAC) experiments near 6 GPa and above 400 K, while co-loaded W, Mo, and Au exhibit normal thermal expansion. The Ta volume expansion increases with temperature, reaching ~14% near 650 K before plateauing, and is largely retained after recovery to ambient conditions. Time-resolved measurements at 500 K reveal progressive expansion over several hours, consistent with gradual, thermally activated He incorporation. The largely retained expansion during subsequent cooling and holding at 400 K indicates that the incorporated He is predominantly kinetically trapped. The data reveal two distinct regimes: below ~550 K, modest and spatially uniform expansion consistent with interstitial He trapping at isolated, randomly distributed vacancies; above ~550 K, He-vacancy cluster growth producing dramatically larger expansion, peak broadening, and a core–shell microstructure revealed by micron-resolution X-ray diffraction mapping. These results demonstrate that He is not always a passive pressure medium in DAC experiments and reveal a previously unrecognized regime of He-mediated lattice modification in Ta, complementing conventional ion-implantation studies relevant to nuclear and fusion structural materials.

Diamond anvil cell

Off‑World Additive Manufacturing - Augmenting NASA‑STD‑6030

This slide presents a summary for a soon to be released white paper on augmenting NASA-STD-6030 for off-world manufacturing. It examines the driving need for in-space manufacturing and its corresponding risks, challenges, potential solutions, and technology development needed to qualify a process.

NASA-STD-6030

Modeling Large Dust Aerosols in the Community Earth System Model Version 2 (CESM2)

Dust aerosols have a wide size distribution from less than 0.1 to over 100 μm and dominate Earth's atmospheric aerosol mass. However, most Earth system models (ESMs) inadequately represent dust aerosols larger than 10 μm in diameter, limiting the accuracy of the simulated dust cycle and climate impacts. Here, we introduce a new modeling framework that captures the full observed size distribution of dust aerosols, incorporating recent advances into a mineral-resolved version of the Community ESM, while addressing known issues in previous versions. Comprehensive evaluation against diverse observations of bulk dust and component minerals demonstrates that the model reproduces the observed dust cycle across particle sizes. Incorporating the previously unrepresented large-dust fractions substantially alters dust budget estimates, highlighting potential changes in simulated climate impacts and underscoring the importance of comprehensive size-resolved dust modeling. Despite these advancements, uncertainties persist. Our results indicate that a size-dependent reduction in settling velocity is required to reproduce the observed dust size distribution downwind of source regions. Specifically, in the new model, the gravitational settling velocity of dust particles larger than 10 μm in diameter must be reduced by as much as 85% to achieve agreement with observations. This empirical reduction serves as a constraint on physics-based models of dust settling. Future developments should address misrepresented physical processes that hinder accurate modeling of the large dust aerosol transport. Expanding observational data sets covering the full-size distribution is also essential to better constrain the dust cycle and improve the representation of dust optical properties and climate effects.

mineral dust

Theory of the thermionic current beyond the traditional space charge limit enabled by trapped ions in the virtual cathode

We show that trapped ions in virtual cathode potential wells can raise the transmitted current of emitted electrons into a plasma much closer to the full emission than is predicted by cathode sheath theories without trapped ions. The transmitted current is controlled by the well barrier voltage, which must adjust to balance the creation of low-energy ions within the well, and their loss. Our model considers the case of a plasma-facing cathode where trapped ions are created passively via charge-exchange collisions and lost passively via thermal leakage over the well. We quantify these rates and estimate the current in terms of system parameters for thermionic emission into a plasma with several cathode geometries. A general prediction is that the current as a function of emitted flux does not saturate at the traditional space charge limit (the onset of a well) but can reach far higher values until the trapped ion balance breaks down, causing instability. The maximum stable current depends on parameters but in principle can be arbitrarily high if active techniques are used to manipulate the trapped ion balance. We conclude that major improvements in plasma technologies with hot cathodes might be achieved by optimizing the current enhancement enabled by trapped ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY