Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERCONNECTED POWER SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Highly Integrated WBG Power Module for Next Generation Plug-In Vehicles

Current inverter technologies used in electric vehicles (EVs) are bulky, heavy, and expensive. The performance of the inverter is also limited by the traditional Si-based semiconductor and packaging technology. These constraints are responsible for extra weight and volume in the vehicle that reduces the driving range along with usable space within the vehicle. Moreover, operating temperature restrictions, and boundaries on the inverter location within the vehicle drastically reduces the inverter performance. Thus an improved inverter design is required for next generation electric vehicles. The objective of this project was to research, develop and demonstrate a highly integrated WBG power module targeting the next generation of plugin hybrid electric vehicles (PHEVs). This power module needed to be functionally and mechanically optimized for General Motors (GM) traction inverter architecture. General Motors was the prime contractor, led the project, and oversaw the design, build, and test of the integrated power module. Virginia Polytechnic Institute and State University (VT) performed modeling and simulation tasks as well as power module design support. Monolith Semiconductor, Inc provided SiC dies and consulted on devices for the inverter. Oak Ridge National Laboratory (ORNL) performed power module technology evaluations, design evaluations of interconnect options, and performed material analysis and cross-sectioning of die activities.

33 ADVANCED PROPULSION SYSTEMS↗

Local Dynamic Reactive Power for Correction of System Voltage Problems

Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results are also provided and discussed. The simulations and testing show that local voltage control from DER can prevent local voltage collapse. The results also show that the control can be provided so quickly, within 0.5 seconds, that is does not interfere with conventional utility methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating AI Data Centers with the Power Grid

The rapid expansion of artificial intelligence (AI) has triggered an unprecedented surge in electricity demand, with US data center energy use projected to double or triple 2023 levels by 2028. This exponential growth places strain on grid infrastructure, which can hinder timely construction of desired computing capacity. To bridge this supply-demand gap, utilities and AI developers are increasingly turning to demand flexibility, a strategy that incentivizes shifting or reducing power use during peak periods of grid stress. Data centers are uniquely equipped for flexible operations due to their digital workloads, built-in redundancy, and onsite energy assets. This article outlines four primary mechanisms to enable data center flexibility: computational load flexibility (shifting tasks temporally or geographically), flexible use of core facility infrastructure adjustments, energy storage utilization, and onsite electricity generation. To encourage adoption, utilities are deploying new tariff designs, including voluntary interruptible service riders, mandated flexibility requirements, and streamlined interconnection processes for flexible loads. For the highly capitalized and rapidly growing AI industry, the primary motivators for embracing these strategies are expediting facility interconnection, satisfying emerging regulatory mandates, and mitigating community resistance. While demand flexibility cannot substitute the long-term need for new bulk power generation, it serves as an essential, immediate solution for enabling near-term deployment. By transforming data centers from grid stressors into stabilizing assets, flexible operations can ensure reliable grid integration, ease market pressures, and support a resilient power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nuclear power plant instrumentation and control cyber security common vector access leading to relational common cause failures - 340

Nuclear power plants and facilities have been implementing digital system upgrades into their previously analog systems for well over twenty years. New nuclear facilities' control, security, and emergency preparedness systems are almost exclusively built on digital architectures with a high degree of communication between the various systems that are often integrated together into a central control station to aid in operation or security of the facility. As digital systems become more widespread in nuclear facility control system architectures, cyber security related issues have become a significant concern to operators, regulators, governments, and other groups. Among the many concerns related to digital systems and cyber security is the area of common cause and common mode failures. This paper introduces, defines, and discusses some sources of common cause failure from a cyber security perspective: common vector access. This refers to specific access points that an adversary can exploit through a single attack sequence that have the potential to provide relational failures through common cause on multiple components, subsystems, systems, or plants. This paper will further discuss interconnected processes where these access points may exist, the importance of limiting or controlling these pinch points, and some methods of protecting common vector access points. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of Microgrid Algorithms using At-Scale Simulation and Emulation Real-Time (ASSERT) Framework

This paper presents a novel framework for validating microgrid algorithms using a At-Scale Simulation and Emulation Real-Time (ASSERT) setup. The proposed universal microgrid validation framework was developed at Advanced Research on Integrated Energy Systems (ARIES) platform at National Renewable Energy Laboratory in Golden, Colorado, USA. As the number of intercommunicating devices grow in power systems, along with more integration of inverter-based resources, developing and validating microgrid operation and control algorithms is becoming complex and time-consuming task. The ASSERT framework is designed to provide a comprehensive, accurate, and efficient solution for validating microgrid algorithms. It combines at-scale simulations and real-time emulation to create a virtual environment that closely mimics the behavior of a physical microgrids which are characteristic of future smart distribution systems, such as: (1) increasing variability in the physical size of new energy technologies; (2) requiring control large numbers of interconnected devices, and (3) integrating diverse technologies that have not previously worked together. The paper describes the technical details of the ASSERT framework, its validation process, and its benefits over traditional validation methods. The framework's ability to validate the performance of various algorithms is demonstrated through a case study, which shows that it can effectively identify the weaknesses of an algorithm and optimize its performance. Overall, the ASSERT framework is a promising tool that can significantly enhance the development and validation of microgrid algorithms, leading to more reliable and efficient microgrid operation.

at-scale↗

Calculating Individual Resources Variability and Uncertainty Factors Based on Their Contributions to the Overall System Balancing Needs

The variability and uncertainty of wind power production requires increased flexibility in power systems, or more operational reserves to main a satisfactory level of reliability. The incremental increase in reserve requirement caused by wind power is often studied separately from the effects of loads. Accordingly, the cost in procuring reserves is allocated based on this simplification rather than a fair and transparent calculation of the different resources’ contribution to the reserve requirement. This work proposes a new allocation mechanism for intermittency and variability of resources regardless of their type. It is based on a new formula, called grid balancing metric (GBM). The proposed GBM has several distinct features: 1) it is directly linked to the control performance standard (CPS) scores and interconnection frequency performance, 2) it provides scientifically defined allocation factors for individual resources, 3) the sum of allocation factors within any group of resources is equal to the groups’ collective allocation factor (linearity), and 4) it distinguishes helpers and harmers. The paper illustrates and provides results of the new approach based on actual transmission system operator (TSO) data.

Makarov, Yuri V.↗

Introduction: Neuromorphic Materials

The explosive growth in data collection and the need to process it efficiently, as well as the desire to automate increasingly complex tasks in transportation, medical care, manufacturing, security and many other fields have motivated a growing interest in neuromorphic computing. Unlike the binary, transistorbased ON/OFF logic gates and separate logic and memory functionalities employed in digital computing, neuromorphic computing is inspired by animal brains that use interconnected synapses and neurons to perform processing, storage and transmission of information at the same location, while only consuming ~20 W or less of power. Motivated by the brain’s efficiency, adaptability, self-learning and resiliency qualities, neuromorphic computing can be broadly defined as an approach to processing and storing information using hardware and algorithms inspired by models of biological neural systems. Present research in neuromorphic computing encompasses approaches that vary significantly in their degree of neuro-inspiration, from systems that only incorporate features such as asynchronous, event-driven operation or use crossbar arrays of non-volatile memory (NVM) elements to accelerate deep neural networks (DNNs), to designs that embrace the extreme parallelism, sparsity, reconfigurability, adaptability, complexity and stochasticity observed in nervous systems. The term ‘neuromorphic’ computing is often credited to Carver Mead, who in the 1980s investigated Si-based analog electronics to replicate functions of the animal retina. Earlier important advances in this field include the work of Frank Rosenblatt, who proposed the concept of the perceptron, Bernard Widrow, who used this concept to build one of the first analog neural networks, the Adaline and many other researchers (see ref. 6 for an historical perspective on neuromorphic computing). With the recent increase in the use of artificial intelligence and large language models, and rising concerns over the associated energy costs, interest in neuromorphic hardware has expanded rapidly. According to some estimates, driven largely by the drastic growth in the training use of artificial intelligence (AI) models using the current computing architectures, the energy cost of computing is projected to reach the energy supply worldwide by 2045. Furthermore, while this is not a realistic outcome, it means that, if more efficient computing technologies are not developed -- soon -- the world will soon become one where demand for energy and market constraints limit the continued increase of societal access to AI and cloud services from data centers. Data centers used for training and use of these models consume hundreds of terawatt hours of electricity, already past 4% of the US electricity demand.

Circuits↗

Low thermal budget photonic processing of highly conductive Cu interconnects based on CuO nanoinks. Potential for flexible printed electronics

The developing field of printed electronics nanoparticle based inks such as CuO show great promise as a low-cost alternative to other metal-based counterparts (e.g., silver). In particular, CuO inks significantly eliminate the issue of particle oxidation, before and during the sintering process, that is prevalent in Cu-based formulations. We report here the scalable and low-thermal budget photonic fabrication of Cu interconnects employing a roll-to-roll compatible pulse-thermal-processing (PTP) technique that enables phase reduction and subsequent sintering of inkjet-printed CuO patterns onto flexible polymer templates. Detailed investigations of curing and sintering conditions were performed to understand the impact of PTP system conditions on the electrical performance of the Cu patterns. Specifically, the impact of energy and power of photonic pulses on print conductivity was systematically studied by varying the following key processing parameters: pulse intensity, duration and sequence. Through optimization of such parameters, highly conductive prints in < 1 s with resistivity values as low as 100 n m has been achieved. We also observed that the introduction of an initial ink-drying step in ambient atmosphere, after the printing and before sintering, leads to significant improvements in mechanical integrity and electrical performance of the printed Cu patterns. Moreover, the viability of CuO reactive inks, coupled with the PTP technology and pre ink-drying protocols, has also been demonstrated for the additive integration of a low-cost Cu temperature sensor onto a flexible polymer substrate.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Utility-Scale Solar, 2021 Edition: Empirical Trends in Deployment, Technology, Cost, Performance, PPA Pricing, and Value in the United States [Slides]

Berkeley Lab’s “Utility-Scale Solar, 2021 Edition” provides an overview of key trends in the U.S. market, with a focus on 2020. Highlights of this year’s update include: A record of nearly 9.6 GWAC of new utility-scale PV capacity came online in 2020, bringing cumulative installed capacity to more than 38.7 GWAC across 43 states. 89% of all new utility-scale PV capacity added in 2020 uses single-axis tracking. Median installed project costs declined to $\$$1.4/WAC (or $\$$1.1/WDC) in 2020. Project-level capacity factors vary widely, from 9% to 36% (on an AC basis), with a sample median of 24%. The report explores drivers of this variation. Utility-scale PV’s LCOE fell to $\$$34/MWh in 2020 ($\$$28/MWh if factoring in the federal investment tax credit, or ITC). PPA prices have largely followed the decline in solar’s LCOE over time, but have stagnated more recently. Prices from a sample of recent contracts average just above $\$$20/MWh (levelized). In 2020, solar’s average market value (defined in the report to include only energy and capacity value) exceeded average wholesale prices in 12 of the 17 balancing authorities analyzed (including 4 of the 7 independent system operators across the United States). Adding battery storage is one way to increase the value of solar. Our public data file tracks metadata for more than 150 PV+battery hybrid projects that are already online or that have secured offtake arrangements. At the end of 2020, there were at least 460 GW of utility-scale solar power capacity within the interconnection queues across the nation, 160 GW of which include batteries. For more information, and to explore related interactive data visualizations, go to utilityscalesolar.lbl.gov.

14 SOLAR ENERGY↗

Hydropower Black Start: A Guidebook for Retrofitting Grid Dependent Hydropower

Not all United States (US) hydropower plants were designed to provide black start, but they are increasingly needed to uphold resilience in the evolving electric grid. This guidance is designed to help understand the minimal retrofits required for grid dependent hydropower (GDH) plants behind the point of interconnection (POI). For distribution connected hydropower plants or those with dedicated cranking paths, such upgrades can be sufficient for the plant to provide black start. For others, more coordination with the transmission system operator will be needed. This guidebook answers a number of questions relevant to retrofitting hydropower plants with black start capabilities. For example, the guidebook answers: • How flexible do the wicket gate controls need to be? • Who needs to do hydro governor model validation, why, and how? • How robust and flexible do the excitation and AVR controls need to be? • What protection settings need to be adjusted? • What relay(s) will need to be bypassed or overridden and at what risk? • What is the electrical energy demand of the station load or auxiliary power systems? • What should the strategy to energize transformer(s) along cranking path to address inrush currents be? • How should the critical load restoration be sequenced? In addition to outlining the specifications that hydropower plants need to meet for each component to be able to perform black start, this guidebook provides a set of case studies for specific upgrades needed at actual plants. Between the case studies of plants that have already performed black start retrofits and the examples of how this guidebook can be applied to scope future retrofits, five key themes have been identified for retrofit needs. 1. Protection needs “black start” mode: hydropower plants that are not designed with black start capabilities will have protections that prevent them from interconnecting to a “dead bus.” These protections will need to be overridden in every retrofit case and a separate black start mode should be established so that operators can safely switch between black start and grid connected modes, minimizing the risk to the plant. 2. Wicket gates need modern controls: digital governors accelerate the parameter tuning process and gate position sensors improve controllability, so plants with mechanical governors should be upgraded. Furthermore, a black start and islanding mode should be established for controls to maximize plant performance. 3. Robust excitation support: the DC system or excitation generator needs to be reliable enough to form and sustain the rotor electromagnetic field. These systems are typically undersized in plants that were not designed for black start, so they will need to be upgraded. 4. Turbine-governor model validation and operator training: validation of a standard hydro governor model is needed to characterize the dynamic response (i.e., inertial and primary frequency response) of the GDH. This is required for control development and old hydropower plants often have outdated or incorrect models. Operator training is also typically required to ensure the hardware retrofits are utilized correctly during the black start process. 5. Transformer and cranking path energization: any upgradation and control adjustment in front of the POI will depend upon the existing interconnection. Coordination with the transmission or distribution operator may be required.

13 HYDRO ENERGY↗

Semiconductor Laser Diode Pumps for Inertial Fusion Energy Lasers

Solid-state lasers have been demonstrated as attractive drivers for inertial confinement fusion on the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) and at the Omega Facility at the Laboratory for Laser Energetics (LLE) in Rochester, NY. For power plant applications, these lasers must be pumped by semiconductor diode lasers to achieve the required laser system efficiency, repetition rate, and lifetime. Inertial fusion energy (IFE) power plants will require approximately 40-to-80 GW of peak pump power, and must operate efficiently and with high system availability for decades. These considerations lead to requirements on the efficiency, price, and production capacity of the semiconductor pump sources. This document provides a brief summary of these requirements, and how they can be met by a natural evolution of the current semiconductor laser industry. The detailed technical requirements described in this document flow down from a laser ampl9ifier design described elsewhere. In brief, laser amplifiers comprising multiple Nd:glass gain slabs are face-pumped by two planar diode arrays, each delivering 30 to 40 MW of peak power at 872 nm during a {approx} 200 {micro}s quasi-CW (QCW) pulse with a repetition rate in the range of 10 to 20 Hz. The baseline design of the diode array employs a 2D mosaic of submodules to facilitate manufacturing. As a baseline, they envision that each submodule is an array of vertically stacked, 1 cm wide, edge-emitting diode bars, an industry standard form factor. These stacks are mounted on a common backplane providing cooling and current drive. Stacks are conductively cooled to the backplane, to minimize both diode package cost and the number of fluid interconnects for improved reliability. While the baseline assessment in this document is based on edge-emitting devices, the amplifier design does not preclude future use of surface emitting diodes, which may offer appreciable future cost reductions and increased reliability. The high-level requirements on the semiconductor lasers involve reliability, price points on a price-per-Watt basis, and a set of technical requirements. The technical requirements for the amplifier design in reference 1 are discussed in detail and are summarized in Table 1. These values are still subject to changes as the overall laser system continues to be optimized. Since pump costs can be a significant fraction of the overall laser system cost, it is important to achieve sufficiently low price points for these components. At this time, the price target for tenth-of-akind IFE plant is $0.007/Watt for packaged devices. At this target level, the pumps account for approximately one third of the laser cost. The pump lasers should last for the life of the power plant, leading to a target component lifetime requirement of roughly 14 Ghosts, corresponding to a 30 year plant life and 15 Hz repetition rate. An attractive path forward involes pump operation at high output power levels, on a Watts-per-bar (Watts/chip) basis. This reduces the cost of pump power (price-per-Watt), since to first order the unit price does not increase with power/bar. The industry has seen a continual improvement in power output, with current 1 cm-wide bars emitting up to 500 W QCW (quasi-continuous wave). Increased power/bar also facilitates achieving high irradiance in the array plane. On the other hand, increased power implies greater heat loads and (possibly) higher current drive, which will require increased attention to thermal management and parasitic series resistance. Diode chips containing multiple p-n junctions and quantum wells (also called nanostack structures) may provide an additional approach to reduce the peak current.

42 ENGINEERING↗

Experimental Evaluation of Load Rejection Over-Voltage from Grid-Tied Solar Inverters

This paper investigates the impact of load rejection over-voltage (LRO) from commercially available grid-tied photovoltaic (PV) solar inverters. LRO can occur when a local feeder or breaker opens and the power output from a distributed energy resource exceeds the load power. Simplified models of current controlled inverters can over-predict over-voltage magnitudes, thus it is useful to quantify testing. The load rejection event was replicated using a hardware testbed at the National Renewable Energy Laboratory (NREL), and a set of commercially available PV inverters was tested to quantify the impact of LRO for a range of generation-to-load ratios. The magnitude and duration of the over-voltage events are reported in this paper along with a discussion of characteristic inverter output behavior. The results for the inverters under test showed that maximum over-voltage magnitudes were less than 200 percent of nominal voltage, and much lower in many test cases. These research results are important because utilities that interconnect inverter-based DER need to understand their characteristics under abnormal grid conditions.

14 SOLAR ENERGY↗

FNETVision: A WAMS Big Data Knowledge Discovery System

With the growing awareness of the power system stability, wide area measurement system (WAMS) has been widely studied and deployed. In WAMS, a phasor data concentrator (PDC) collects and persists the GPS-time-synchronized phasor data from hundreds of phasor measurement units (PMU). Due to the size and complexity of the modern power systems, the number of deployed PMUs has been increasing and their data size becomes increasingly large. The large data volume challenges the analysis, and the knowledge discovery of the measurement data. This paper takes the pioneering distribution level WAMS- the frequency monitoring network FNET/GridEye as an example. It develops an adaptive visualization system- FNETVision to visualize the large-volume WAMS data by interconnection. The case studies suggest, based on the FNETVision system, the system administrator can quickly dig out issues of the FNET system and accordingly pinpoint the cause of these issues.

Wang, Weikang↗

Energy Systems Integration Facility (ESIF): World-Class Systems Integration Capabilities and Research

The Energy Systems Integration Facility (ESIF), located at the National Renewable Energy Laboratory (NREL) South Table Mountain campus, is a world-renowned user facility for research and development of modern, advanced, and clean energy technologies. ESIF is distinguished by its continuously evolving, highly integrated systems that span throughout the building, connecting research capabilities across multiple laboratories and test areas. The primary ESIF research systems include: [1] data, cyber, and control networks, [2] research electrical distribution buses (REDB), [3] thermal integration infrastructure, and [4] hydrogen systems. The data, cyber, and control networks provide monitoring, control, communication, automation, visualization, and time series data storage and tagging capabilities for research projects and ESIF systems, including facility safety functions. The REDB system consists of four dedicated AC and DC electrical power networks that can connect devices located across the facility through versatile, automatic circuit configuration to support complex power electronics experiments up to the megawatt-scale. The thermal integration infrastructure consists of three temperature-conditioned water loops that provide heating and cooling interfaces and capabilities for thermal energy research. The hydrogen systems provide megawatt-scale hydrogen production, drying, compression, high-pressure storage, and delivery to laboratory end uses, including hydrogen fuel cell vehicle fueling. The ESIF research systems interconnect and extend throughout the various lab areas of the facility to create elaborate networks composed of diverse technologies for cutting-edge research. The ESIF capabilities are operated and stewarded by the ESIF Research Operations group, who also actively upgrade and advance the systems to ensure they remain ahead of anticipated research - enabling the success of many pioneering energy integration projects. The poster, created by members of the ESIF Research Operations team, highlights and summarizes the four core integrated systems at ESIF. The poster was first presented at the internal NREL Energize Forum on May 13th, 2024, and received the "Best Poster" award.

capabilities↗

Status and Trend of Automotive Power Packaging

Comprehensive requirements in aspects of cost, reliability, efficiency, form factor, weight, and volume for power electronics modules in modern electric drive vehicles have driven the development of automotive power packaging technology intensively. Innovation in materials, interconnections, and processing techniques is leading to enormous improvements in power modules. In this paper, the technical development of and trends in power module packaging are evaluated by examining technical details with examples of industrial products. The issues and development directions for future automotive power module packaging are also discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Guest Editorial: Special issue on flexible and resilient urban energy systems

This guest editorial summarizes the topics and the papers selected for the Special Issue on Flexible and Resilient Urban Energy Systems. After rigorous reviewing process, 21 papers are accepted for publication. These 21 accepted papers cover various aspects of urban energy systems and are distributed as following: situational awareness of urban energy systems (2 papers), quantification metrics of flexibility and resilience of urban energy systems (3 papers), vulnerability modeling of urban energy systems under various extreme events (3 papers), planning of flexible and resilient urban energy systems (4 papers), robust and resilient operation and control of urban energy systems (4 papers), recovery and restoration strategy of urban energy systems (2 papers), and coordination and interoperability of interconnected energy systems (3 papers). The Guest Editorial Board hopes this Special Issue can provide a valuable information for future research and advancements in the field of flexible and resilient urban energy systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗