Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beamline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Focusing with saw-tooth refractive lenses at a high-energy X-ray beamline

The Advanced Photon Source 1-ID beamline, operating in the 40–140 keV X-ray energy range, has successfully employed continuously tunable saw-tooth refractive lenses to routinely deliver beams focused in both one and two dimensions to experiments for over 15 years. The practical experience of implementing such lenses, made of silicon and aluminium, is presented, including their properties, control, alignment, and diagnostic methods, achieving ∼1 µm focusing (vertically). Ongoing development and prospects towards submicrometre focusing at these high energies are also mentioned.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser heating system at the Extreme Conditions Beamline, P02.2, $\mathrm{PETRA III}$

A laser heating system for samples confined in diamond anvil cells paired with in situ X-ray diffraction measurements at the Extreme Conditions Beamline of PETRA III is presented. The system features two independent laser configurations (on-axis and off-axis of the X-ray path) allowing for a broad range of experiments using different designs of diamond anvil cells. The power of the continuous laser source can be modulated for use in various pulsed laser heating or flash heating applications. An example of such an application is illustrated here on the melting curve of iron at megabar pressures. The optical path of the spectroradiometry measurements is simulated with ray-tracing methods in order to assess the level of present aberrations in the system and the results are compared with other systems, that are using simpler lens optics. Based on the ray-tracing the choice of the first achromatic lens and other aspects for accurate temperature measurements are evaluated.

47 OTHER INSTRUMENTATION↗

Scanning structural mapping at the Life Science X-ray Scattering Beamline

This work describes the instrumentation and software for microbeam scattering and structural mapping at the Life Science X-ray Scattering (LiX) beamline at NSLS-II. Using a two-stage focusing scheme, an adjustable beam size between a few micrometres and a fraction of a millimetre is produced at the sample position. Scattering data at small and wide angles are collected simultaneously on multiple Pilatus detectors. A recent addition of an in-vacuum Pilatus 900k detector, with the detector modules arranged in a C-shaped configuration, has improved the azimuthal angle coverage in the wide-angle data. As an option, fluorescence data can be collected simultaneously. Fly scans have been implemented to minimize the time interval between scattering patterns and to avoid unnecessary radiation damage to the sample. For weakly scattering samples, an in-vacuum sample environment has been developed here to minimize background scattering. Data processing for these measurements is highly sample-specific. To establish a generalized data process workflow, first the data are reduced to reciprocal coordinates at the time of data collection. The users can then quantify features of their choosing from these intermediate data and construct structural maps. As examples, results from in-vacuum mapping of onion epidermal cell walls and 2D tomographic sectioning of an intact poplar stem are presented.

36 MATERIALS SCIENCE↗

A new Kirkpatrick–Baez-based scanning microscope for the Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II

The development, construction, and first commissioning results of a new scanning microscope installed at the 5-ID Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II are reported. The developed system utilizes Kirkpatrick–Baez mirrors for X-ray focusing. The instrument is designed to enable spectromicroscopy measurements in 2D and 3D with sub-200 nm spatial resolution. The present paper focuses on the design aspects, optical considerations, and specifics of the sample scanning stage, summarizing some of the initial commissioning results.

36 MATERIALS SCIENCE↗

Resonant inelastic X-ray scattering endstation at the 1C beamline of Pohang Light Source II

An endstation for resonant inelastic X-ray scattering (RIXS), dedicated to operations in the hard X-ray regime, has been constructed at the 1C beamline of Pohang Light Source II. At the Ir L 3 -edge, a total energy resolution of 34.2 meV was achieved, close to the theoretical estimation of 34.0 meV, which considers factors such as the incident energy bandpass, intrinsic analyzer resolution, geometrical broadening of the spectrometer, finite beam-size effect and Johann aberration. The performance of the RIXS instrument is demonstrated by measuring the RIXS spectra of Sr 2 IrO 4 . The endstation can be easily reconfigured to measure energy-integrated intensities with very low background for diffuse scattering and diffraction experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Five-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition

Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ALS-ENABLE: creating synergy and opportunity at the Advanced Light Source synchrotron structural biology beamlines

ALS-ENABLE is an integrated NIH P30 resource at the Advanced Light Source synchrotron at Lawrence Berkeley National Laboratory in Berkeley, California, USA. The resource provides a single portal to the combined mature structural biology technologies of macromolecular crystallography, small-angle X-ray scattering and X-ray footprinting mass spectrometry, and includes beamlines 2.0.1, 3.3.1, 4.2.2, 5.0.1, 5.0.2, 5.0.3, 8.2.1, 8.2.2, 8.3.1 and 12.3.1. This paper describes the organizational structure and the technologies of ALS-ENABLE. A case study showcasing the main technologies of the resource applied to the characterization of the SpyCatcher-SpyTag protein system is presented.

Ralston, Corie Y↗

Phasing Magnet for CSX-2 Beamline at NSLS-II

A phasing magnet has been developed at National Synchrotron Light Source II (NSLS-II) for the Coherent Soft X-ray Scattering (CSX) beamline. The phasing magnet will be located at the center of the straight section in between two identical and independent variably polarized APPLE-II devices. Based on Permanent Magnet technology, the phasing magnet has been designed to achieve the required electron beam delay to properly adjust the phase matching of these two consecutive EPUs (Elliptically Polarizing Undulators) and ensure a positive interference between the photon beam emitted in each device. Also this paper will describe the mechanical and magnetic design together with the final field measurements and magnetic tuning results. Also, the spectral performance of the two EPUs and the method used to properly set the field strength of the phasing magnet for any given radiation wavelength and polarization mode will be presented as well.

36 MATERIALS SCIENCE↗

Jupyter notebooks for analyzing transmission SAXS/WAXS from beamline 7.3.3 during operando membrane fouling experiments v1.0

This software consists of python-based Jupyter Notebooks for processing transmission x-ray scattering images collected at beamline 7.3.3 at the Advanced Light Source. The measurements considered in these analyses are collected during membrane fouling experiments, where contaminants in the water deposit on/attach to the membrane surface. This software is used to elucidate the mechanisms of membrane fouling that occur during these operando membrane fouling experiments, but the analyses provided in these scripts can be extended to other scientific cases.

Landsman, Matthew [Lawrence Berkeley National Labo↗

The study of high-frequency pick-ups for electron beam position measurements in the AWAKE common beamline

The common beamline of the AWAKE experiment at CERN involves the co-propagation of two particle beams: protons with 48 nC bunch charge and 250 ps bunch length, and electrons with up to 600 pC bunch charge and approximately 4 ps bunch length. The existing operational beam position monitors at AWAKE cannot measure the electron bunches whilst the more-intense proton bunches are present, due to their low operating frequency. In order to try to address this challenge, two different types of high-frequency pick-ups were studied, a conical-shaped button pick-up and a Cherenkov diffraction radiation-based pick-up designed to operate at around 30 GHz. Both devices were installed at AWAKE and were connected to two identical read-out systems designed by TRIUMF. This contribution presents and discusses the results obtained from beam-based measurements during the current experimental year.

43 PARTICLE ACCELERATORS↗

Design of a 10 MeV beamline at the Upgraded Injector Test Facility for e-beam irradiation

Electron beam irradiation near 10 MeV is suitable for wastewater treatment. The Upgraded Injector Test Facility (UITF) at Jefferson Lab is a CW superconducting linear accelerator capable of providing an electron beam of energy up to 10 MeV and up to 100 µA current. This contribution presents the beam transport simulations for a beamline to be used for the irradiation of wastewater samples at the UITF. The simulations were done using the code General Particle Tracer with the goal of obtaining an 8 MeV electron beam of radius (3-σ) of ~2.4 cm. The achieved energy spread is ~74.5 keV. The space charge effects were investigated when the bunch charge is varied to be up to 1000 times and the results showed that they do not affect the beam quality significantly.

Li, X.↗

EXPERIMENTAL DEMONSTRATION OF A STRAIGHT-MERGER BEAMLINE

Beamlines capable of merging beams with different energies are critical to many applications related to advanced accelerator concepts and energy recovery linacs (ERLs). A straight merger system composed of a transverse deflecting cavity with a superimposed dipole magnet was proposed and recently tested at the Argonne Wakefield Accelerator. This paper reports on the experimental demonstration of the concept along with detailed beam dynamics investigations of the merger concept and its ability to conserve the beam brightness associated with the fresh bunch. Possible applications to ERL and beam-driven wakefield accelerators are also discussed.

Phillips, C.↗

Computational simulations and beamline optimizations for an electron beam degrader at CEBAF

An electron beam degrader is under development with the objective of measuring the transverse and longitudinal acceptance of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This project is in support of the CE+BAF positron capability. Computational simulations of beam-target interactions and particle tracking were performed integrating the GEANT4 and Elegant toolkits. A solenoid was added to the setup to control the beam's divergence. Parameter optimization of the solenoid field and magnetic quadrupoles gradient was also performed to further reduce particle loss through the rest of the injector beamline.

Lizárraga-Rubio, V.↗

Second Generation Fermilab Main Injector 8 GeV Beamline Collimation Preliminary Design

The current Fermilab Main Injector 8 GeV beamline transverse collimation system was installed in 2006. Since then, proton beam intensities and rates have increased significantly. With the promise of even greater beam intensities and a faster repetition rate when the PIP-II upgrade completes later this decade, the current collimation system will be insufficient. Over the past 18 months, multiple collimation designs have been investigated, some more traditional and others novel. A preliminary design review was conducted and a design chosen. Work is underway to finalize the chosen design, prototype some of its novel components and procure parts for installation Summer 2023.

43 PARTICLE ACCELERATORS↗

Preliminary Tests and Beam Dynamics Simulations of a Straight-Merger Beamline

Beamlines capable of merging beams with different energies are critical to many applications related to advanced accelerator concepts and energy-recovery linacs (ERLs). In an ERL, a low-energy "fresh" bright bunch is generally injected into a superconducting linac for acceleration using the fields established by a decelerated "spent" beam traveling on the same axis. A straight-merger system composed of a selecting cavity with a superimposed dipole magnet was proposed and recently test at AWA. This paper reports on the experimental results obtained so far along with detailed beam dynamics investigations of the merger concept and its ability to conserve the beam brightness associated with the fresh bunch.

Al Marzouk, A. A.↗

An e-beam irradiation beamline at Jefferson Lab for 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) remediation in wastewater

The Upgraded Injector Test Facility (UITF) at Jefferson Lab, providing a beam energy up to 10 MeV, is suitable for wastewater remediation research. To investigate the degradation of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS), widespread in wastewater and potential to be regulated in near future, a beamline for electron-beam irradiation has been designed, installed and successfully commissioned at the UITF. A solenoid with a peak axial magnetic field of up to 0.28 T and a raster were used to obtain a Gaussian beam profile with a transverse standard deviation of 15 mm. It was applied to irradiate 1,4-dioxane sample filled in the target cell that was designed to let the entire sample receive significant irradiation doses. The dose distribution and absorbed dose, few studied in the current publications, are necessary measures for the degradation mechanism investigation and have been innovatively achieved in this work using simulations which were calibrated with opti-chromic dosimeter rods directly exposed to the electron beam. This approach provides an important way for investigating the environmental remediation impact of electron-beam irradiation.

Li, Xi↗

USING E-BEAM IRRADIATION BEAMLINE AT JEFFERSON LAB TO REMOVE 1,4-DIOXANE AND PFAS IN WASTEWATER

The designed e-beam irradiation beamline [1] at Jefferson Lab has been commissioned and applied to study the degradation removal of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) in wastewater by collaborating with Hampton Roads Sanitation District (HRSD), treating wastewater in southeast Virginia. The absorbed dose and dose distribution in the entire sample were achieved innovatively using Monte-Carlo simulations that were calibrated with opti-chromic dosimeter rods directly exposed to the e-beam. This research could be a stepstone to the future MW compact SRF accelerator [2] for wastewater remediation.

Li, X.↗