Neutron Dosimetry for the University of Central Florida (UCF3) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the University of Central Florida (UCF)-3 third stage experiment which was conducted in position B8 of the ATR. Three other irradiations included in the scope of work are reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the UCF-3 assemblies at INL prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at 8 fluence monitor locations. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Dosimetry for the Boise State University JW 15-8242 Irradiation in ATR (Rev.1)

PNNL project 79550 provides for the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00269673and Statement of Work No. 19704, Rev. 0, PNNL Analysis of NSUF Flux Capsules. This report is for the Boise State University (BSU) JW 15-8242 irradiations which were conducted in positions A6, A7 and A8 of the ATR. We previously reported data for this experiment after about 1 dpa in a report issued in January 2021 (1). This report is for longer irradiations to about 3 dpa. Other experiments included in the statement of work for this project will be reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the BSU assemblies prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma or x-ray analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY21 Progress of the Oak Ridge Health Physics Research Reactor CAAS Benchmark Evaluation [Slides]

The FY21 version of the evaluation, focusing on element 57 dose at 3 meters, was presented at the ICSBEP Technical Review Group meeting in October 2021 and was not accepted for 2022 publication in the handbook. The main issue was identified and replacement of the element 57 neutron dose benchmark metric by neutron fluence (closer to what was measured) is required. A subgroup was formed, confident for the updated neutron fluence evaluation to be accepted in the ICSBEP handbook. The updated evaluation will be presented again at the 2022 ICSBEP TRG for publication in the 2023 handbook.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Apollo 16 neutron stratigraphy.

The Apollo 16 soils have the largest low-energy neutron fluences yet observed in lunar samples. Variations in the isotopic ratios Gd-158/Gd-157 and Sm-150/Sm-149 (up to 1.9 and 2.0%, respectively) indicate that the low-energy neutron fluence in the Apollo 16 drill stem increases with depth throughout the section sampled. Such a variation implies that accretion has been the dominant regolith 'gardening' process at this location. The data may be fit by a model of continuous accretion of pre-irradiated material or by models involving as few as two slabs of material in which the first slab could have been deposited as long as 1 b.y. ago. The ratio of the number of neutrons captured per atom by Sm to the number captured per atom by Gd is lower than in previously measured lunar samples, which implies a lower energy neutron spectrum at this site. The variation of this ratio with chemical composition is qualitatively similar to that predicted by Lingenfelter et al. (1972). Variations are observed in the ratio Gd-152/Gd-160 which are fluence-correlated and probably result from neutron capture by Eu-151.

Russ, G. P., III↗

Materials-of-Construction Radiation Sensitivity for a Fission Surface Power Convertor

A fission reactor combined with a free-piston Stirling convertor is one of many credible approaches for producing electrical power in space applications. This study assumes dual-opposed free-piston Stirling engines/linear alternators that will operate nominally at 825 K hot-end and 425 K cold-end temperatures. The baseline design options, temperature profiles, and materials of construction discussed here are based on historical designs as well as modern convertors operating at lower power levels. This notional design indicates convertors primarily made of metallic components that experience minimal change in mechanical properties for fast neutron fluences less than 10(sup 20) neutrons per square centimeter. However, these radiation effects can impact the magnetic and electrical properties of metals at much lower fluences than are crucial for mechanical property integrity. Moreover, a variety of polymeric materials are also used in common free-piston Stirling designs for bonding, seals, lubrication, insulation and others. Polymers can be affected adversely by radiation doses as low as 10(sup 5) - 10(sup 10) rad. Additionally, the absorbing dose rate, radiation hardness, and the resulting effect (either hardening or softening) varies depending on the nature of the particular polymer. The classes of polymers currently used in convertor fabrication are discussed along possible substitution options. Thus, the materials of construction of prototypic Stirling convertor engines have been considered and the component materials susceptible to damage at the lowest neutron fluences have been identified.

Bowman, Cheryl L.↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Nuclear fuels for transient test reactors

Transient test reactors with the ability to test fissile specimens under extreme conditions have been crucial tools in the development of nuclear technologies. Less than 10 unique facility designs have ever been constructed, most of which remain operational today and still use the original nuclear fuel constructed for them more than 40 years ago. Historic fuel systems for transient test reactors vary in significant ways which have marked influences on reactor capabilities. Eventually, new fuel will be needed to support the longevity of transient test reactor missions. This paper reviews precedent transient reactor fuel systems in the context of their unique requirements. A few key conclusions are illustrated by comparing and contrasting these transient test reactors. Fuel composites which are mostly graphite can enable transient reactors with very high neutron fluence capability (>2E16 n/cm 2 ) and are amenable to longer “shaped” transients but cannot achieve pulses <10 ms in duration. Reducing the graphite-to-uranium ratio can yield a very narrow pulse capability but delivers less fluence and requires cores with considerably more fissile material. Designs based on uranium dioxide (UO 2 ) make use of readily available materials to create compact cores with narrow pulse width capabilities but with moderate neutron fluence capabilities (~2E15 n/cm 2 ). Uranium zirconium hydride (U-ZrHx) is a well-established fuel system for pulsing reactors which has been intermittently manufactured throughout the decades. U-ZrHx offers similar capabilities to UO 2 designs in terms of nuclear kinetics, but with about half the fluence capability (~1E15 n/cm 2 ). An evolution of the UO 2 system, termed “ternary ceramic” fuel, shows that dispersing UO 2 in zirconium oxide and calcium oxide can increase fluence capability greatly (~7E15 n/cm 2 ), but is not presently a commonly available fuel form. A unique composite of UO 2 and beryllium oxide (UO 2 -BeO) can be used to create a core with similar kinetics and compact core geometry as U-ZrHx designs, but with significantly higher fluence capability (~6E15 n/cm 2 ). Like ternary ceramic fuel, newly fabricated UO 2 -BeO would require reestablishing its historic manufacturing process which would be further complicated by the health hazards associated with beryllium. In conclusion, like most engineering problems, there is no perfect solution, but this paper outlines the advantages and disadvantages of candidate fuel options to help guide detailed evaluations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Irradiation of ultrasonic sensors and adhesive couplants for application in light water reactor primary loop piping and components

The Electric Power Research Institute (EPRI) Nuclear Sector and US Department of Energy Light Water Reactor Sustainability Program are committed to engaging in research and development endeavors to address materials aging issues specific to long term operation of light water power reactors. To this effect, EPRI launched an industry initiative to develop nondestructive evaluation systems for online monitoring of existing cracks in light water reactor primary coolant loop piping and components. One of the goals of this initiative is to develop a sensor system (or systems) that can determine nondestructively if cracks are growing or arrested and, in the case of the former, to characterize their growth rates. A missing component of this initiative is an experimental assessment of how sensors and adhesive couplants will perform in service when exposed to chronic energetic neutron radiation, particularly at the primary coolant loop hot and cold leg dissimilar metal welds, which join the primary loop piping to the reactor pressure vessel and reside in the vicinity of the reactor core. The objective of this experimental study was to determine how ultrasonic transducers and adhesive couplants perform when exposed to irradiation in a test reactor to simulate and accelerate in-service exposure. Further, to achieve this objective, the signal stability of piezoelectric transducers and performance of adhesive couplants as a function of accumulated fast neutron fluence were characterized by collecting ultrasonic data in-situ during irradiation. Of particular interest were the ultrasonic signal quality and time decay of the amplitude of acoustic reflections as a function of fast neutron fluence. The results of the study showed that, of the 8 transducer/substrate sample assemblies tested, only 3 generated usable ultrasonic signals through the conclusion of the irradiation campaign. It was found that high temperature epoxy tends to ultrasonically couple the sensors to the substrates better than three types of refractory ceramic cements studied, as is supported by post irradiation examination. The results obtained through this experimental study will be utilized in the achievement of the overall goal of development of a sensor system to perform online monitoring of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiation-induced alteration of sandstone concrete aggregate

This study investigates the alteration of felsic sandstone-type rock, which is used as a coarse aggregate in concrete, subject to the effects of gamma-ray and neutron irradiation. The effects of three gamma-ray doses (27, 55, and 108 MGy) and four neutron fluence levels (1.22, 2.19, 6.99, and 14.30 × 10 19 n/cm 2 , $E$ ≥ 0.01 MeV) were investigated. Quartz and albite were found to be the major rock-forming minerals, with microcline intermediates, chlorite, and muscovite as the minors. Gamma rays caused no significant changes to the physical properties of the sandstone aggregates, even at high doses (108 MGy). In contrast, neutron irradiation caused alterations that became more pronounced at higher neutron fluences. The solid was confirmed to expand through metamictization of the rock-forming minerals. Quartz and muscovite were the most affected phases, whereas albite and microcline intermediates were only slightly affected, and chlorite was almost unaffected. The decrease in density was measured by He and water pycnometry, and this value was almost reproduced by calculations using the rock-forming mineral composition of the pristine sample measured using X-ray powder diffraction/Rietveld analysis and the cell volume change of the major forming minerals. In addition, light optical microscopy and scanning electron microscopy images confirmed the presence of intergranular and intragranular cracks. Intergranular cracks appeared to have initiated from the quartz grains, which expanded significantly. The intragranular cracks were frequently observed in the albite and microcline intermediates. These cracks can be described as radial cracks starting from the expanding quartz, caused by enforced displacement for deformation consistency with quartz expansion. The crack area ratio quantified by SEM image analysis corresponds to the discrepancy of the volume expansion difference calculated by He or water pycnometry and dimensional change measurements. In conclusion, an evaluation of solid expansion and crack openings in aggregates is important to estimate concrete degradation.

36 MATERIALS SCIENCE↗

Optical transmission and dimensional stability of single-crystal sapphire after high-dose neutron irradiation at various temperatures up to 688 °C

The use of single-crystal sapphire optical fibers has been considered to extend fiber-optic sensing to the extreme temperature (>1000 °C) environments encountered in nuclear applications. However, before these sapphire fiber–based sensors can be deployed, their optical transmission and dimensional stability (which impacts drift of some sensors) must be characterized under representative testing conditions. Data regarding the optical transmission of sapphire following high-dose neutron irradiation at temperatures >100 °C is extremely limited. This work provides measurements of optical density (i.e., attenuation) and directional dimensional changes in bulk single-crystal sapphire materials irradiated to a fast neutron fluence of 2.4 × 10 21 n/cm 2 (3.5 displacements per atom) at temperatures ranging from 95 to 688 °C. Optical density measured after irradiation at 95 and 298 °C showed ultraviolet and visible absorption bands corresponding to known defect centers and temperature trends that were generally consistent with previous ex situ and in situ measurements made at much lower neutron fluence. However, optical density measured after irradiation at 688 °C was as much as two orders of magnitude higher, indicating that the fundamental mechanism for radiation-induced attenuation changes at this irradiation temperature. Additional analysis and comparison with previous works suggest that the attenuation may result from void formation, leading to increased Rayleigh scattering losses in the material and increased swelling that would also result in drift of Bragg grating-based sensors in sapphire fibers. These results pose serious questions regarding the feasibility of sapphire fiber–based sensors for high-temperature nuclear applications.

36 MATERIALS SCIENCE↗

14 MeV DT Neutron Test Facility at the Sandia Ion Beam Laboratory

A recently completed LDRD project has provided a new facility at Sandia for testing effects of energetic neutrons on electronic components. 14 MeV neutrons are produced with a deuterium ion beam onto a thin-film tritide target. The goal of the project was to increase the neutron fluence to levels needed for radiation effects testing and qualification. This goal was achieved through two technical advances. First, a new multi-layer target concept was developed to reduce the rate of tritium loss from the target by isotope exchange, thereby reducing tritium usage and increasing target lifetime. The second advance was the construction of a new test chamber designed to maximize neutron flux at test locations. Together, these increased the available neutron fluence by several orders of magnitude. This new capability is being used in tests for Sandia nuclear weapon programs, evaluation of commercial parts such as highly-scaled CMOS SRAM lCs, and tests of new devices under development at Sandia such as lll-V HBTs, gallium nitride high-voltage diodes, and for fundamental studies of physical mechanisms of device failure.

36 MATERIALS SCIENCE↗

The new ITER baseline, research plan and open R&D issues

A new baseline (NB) has been proposed by the ITER Project to ensure a robust achievement of the Projects’ goals, in view of past challenges including delays incurred due to the Covid-19 pandemic, technical challenges in completing first-of-a-kind components and in nuclear licensing. The NB includes modifications to the configuration of the ITER device and its ancillaries (e.g. change from beryllium to tungsten as first wall material, modification of the heating and current drive mix, etc.) as well as additional testing of components (e.g. toroidal field coils) or phased installation (start with inertially cooled first wall before later installation of the final actively water-cooled components) to minimise operational risks. In the NB, the ITER research plan (IRP) will be divided into three main phases: (a) start of research operation, with 40 MW of ECH and 10 MW of ICH, which will focus on the demonstration of 15 MA operation in L-mode, commissioning of all required systems, including disruption mitigation, and the demonstration of H-mode plasma operation in deuterium; (b) DT-1, with 60–67 MW of ECH, 33 MW of neutral beam injection (NBI) and 10–20 MW of ICH, which will demonstrate robust operation in high confinement H-mode plasmas in DT up to Q ⩾ 10 and for burn durations of 300–500 s within an accumulated neutron fluence of ∼1% of the ITER machine’s lifetime total, and; (c) DT-2, with up to 67 MW of ECH, up to 49.5 MW of NBI and up to 20 MW of ICH, with the ITER tokamak and ancillaries in their final configuration to demonstrate routine operation in DT plasmas at high Q and the Q ⩾ 5 long-pulse and steady-state scenarios to the final neutron fluence and to perform R&D on nuclear fusion reactor issues. The logic, physics basis, modelling and experimental evaluations carried out to support the NB and the associated IRP are described. These include the impact of the tungsten wall on plasma scenarios and associated risk mitigation measures, as well as the optimisation of the tokamak components and ancillaries to minimise Project risks. Open R&D issues related to these evaluations and mitigation measures are also described together with experimental, modelling and validation activities required to address them.

ITER↗

Enhanced backscatter and unsaturated blue wavelength shifts in F-doped fused silica optical fibers exposed to extreme neutron radiation damage

Amorphous fused silica (a-SiO 2 ) optical fibers, with and without inscribed Bragg gratings, were interrogated using infrared (~1550 nm) optical backscatter reflectometry during ~25 days of intense neutron irradiation to a fast (energy > 0.1 MeV) neutron fluence of ~10 21 n/cm 2 , or ~1.5 atomic displacements per atom. The reflected light amplitudes in Ge-doped core telecommunications fiber dropped below detection limits (>15 dB attenuation) within 3 days of irradiation (~10 20 fast n/cm 2 ). Here, amplitudes from a pure silica core, F-doped silica cladding fiber reached equilibrium levels ~1.5–2 dB higher than pre-irradiation values, whereas Bragg gratings inscribed in the same fiber using a femtosecond laser (point-by-point method) suffered > 45 dB attenuation. Blue wavelength shifts were initially consistent with previous radiation-induced compaction models but increased linearly with increasing neutron fluence (no evidence of saturation) beyond 10 20 n/cm 2 and exceeded 0.6%, which corresponds to >1,000 °C drift if used to measure temperature changes.

36 MATERIALS SCIENCE↗

An Integral Experiment on Polyethylene Using Radiative Capture in Indium Foils in a High Flux D-D Neutron Generator

In this work, we report here the results of a measurement of the scattered versus unscattered neutron fluence on polyethylene determined via neutron activation of multiple natural indium foils from a deuterium-deuterium (D-D) neutron generator. The neutrons were produced by the High Flux Neutron Generator (HFNG) at the University of California, Berkeley, a specially designed source to maximize neutron flux on a sample while minimizing the total neutron yield. During the experiment, approximately 10 8 n/s were produced with the energies at the indium foils ranging from 2.2 to 2.8 MeV. Both the angle-integrated and the partial angle differential results are consistent with the predictions of the Monte Carlo N-Particle Transport (MCNP) code, using ENDF/B-VII.1. This supports shielding calculations in the fast energy region with high-density polyethylene.

42 ENGINEERING↗

Hadron-Induced Radiation Damage in Fast Heavy Inorganic Scintillators

Fast and heavy inorganic scintillators with suitable radiation tolerance are required to face the challenges presented at future hadron colliders of high energy and intensity. Up to 5 GGy and 5 × 1018 neq/cm2 of one-MeV-equivalent neutron fluence is expected by the forward calorimeter at the Future Hadron Circular Collider. This paper reports the results of an investigation of proton- and neutron-induced radiation damage in various fast and heavy inorganic scintillators, such as LYSO:Ce crystals, LuAG:Ce ceramics, and BaF2 crystals. The experiments were carried out at the Blue Room with 800 MeV proton fluence up to 3.0 × 1015 p/cm2 and at the East Port with one MeV equivalent neutron fluence up to 9.2 × 1015 neq/cm2, respectively, at the Los Alamos Neutron Science Center. Experiments were also carried out at the CERN PS-IRRAD proton facility with 24 GeV proton fluence up to 8.2 × 1015 p/cm2. Research and development will continue to develop LuAG:Ce ceramics and BaF2:Y crystals with improved optical quality, F/T ratio, and radiation hardness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

As-Run Physics Analysis for the AGC-4 Experiment Irradiated in the ATR

This Engineering Calculations Analysis Report (ECAR) documents the results of the Advanced Test Reactor (ATR) detailed physics analyses performed to calculate the displacements per atom (DPA) and the fast neutron fluence (E > 0.1 MeV) of the Advanced Graphite Creep (AGC) experiment, AGC-4, irradiated in the ATR East Flux Trap (EFT) (see Figure 1) during ATR Cycle 157D, 158A, 162A, 162B, 164A, 164B, 166A, and Cycle 166B. This ECAR also reports the neutron and photon heat rates for the materials of the AGC-4 experiment for ATR Cycle 158A (timestep 19), which provides to the maximum heating. The results for these evaluations and analysis are reported herein. The AGC-4 as-run specimen neutron fast fluence (E > 0.1 MeV), DPA, and material heat rate calculations were performed using a general-purpose Monte Carlo N-Particle (MCNP) code. All calculated results are tabulated herein.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of fluence-rate determination techniques for the Advanced Test Reactor-Critical Facility

A technique using small, enriched uranium-aluminum alloy monitors to measure fission rates in fuel plate assembly reactors was developed at the Idaho National Laboratory Radiation Measurements Laboratory in support of Advanced Test Reactor Critical (ATR-C) Facility irradiations. Previous measurements were performed to determine the correlation between the beta-particle activity and the fission rate in the U-Al monitors following irradiation. The American Society for Testing and Materials (ASTM) has established a standard practice E704 for determining neutron fluence rate by radioactivation of depleted uranium by measuring the concentration of fission-products in irradiated uranium monitors. Rather than measuring the beta-particle decay from fission-products, the decay rate of fission-products is determined by gamma-ray spectroscopy. The feasibility of using a method adapted from the ASTM standard practice E704 was investigated for ATR-C irradiations and compared to the present method by analyzing a subset of 21 monitor wires using both methods. The resulting calculated fission rates agreed with an average standard deviation of 7.45%, within the average combined measurement error of 9.05%. Practical considerations such as expected fluence-rates, sample activity, and counting-time were compared between the two methods and the sources of error for each method were investigated. Quality assurance measurements utilizing the modified ASTM standard method are recommended for future test irradiation, but gross-beta-particle counting remains the most practical solution for ATR-C fluence-rate determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment (Final Report)

This report documents the FY25 Theory and Simulation Performance Target (TSPT) of developing an integrated modeling framework for fusion reactor design and assessment (FREDA). Over Q1-Q4, new capabilities were developed across both plasma and engineering domains and demonstrated on an example representation of a Compact Advanced Tokamak with a Dual Cooled Lead Lithium blanket. This represents a first-of-a-kind demonstration of coupled core-to-wall-to-engineering for a reactor. Self-consistent CESOL workflows were applied to provide core, pedestal, and SOL prediction; new modules were developed for energetic particle stability (FAR3D) and transport (TGLF-EP) analysis; and boundary plasma modeling (SOLPS-ITER, BOUT++/Hermes-3) was expanded to evaluate wall and divertor heat fluxes and interface with engineering thermal analysis. A parameterized CAD tool, TRACER, was expanded to generate medium-fidelity divertor, blanket, and coil geometries; OpenFOAM and Diablo workflows were applied for first-wall and divertor thermal analyses with helium cooling; and reduced-order models were created for high-mass-flux divertor cooling. Magnet multiphysics capabilities were verified between Elmer, Diablo, and a new MFEM-based solver, and workflows enable stress, thermal, and neutron-fluence analysis of TF coils with neutronics-driven heating. Nuclear and blanket analysis workflows were demonstrated, including tritium breeding, transport, and CFD-informed thermo-mechanical assessment. Preliminary multi-fidelity uncertainty quantification workflows were applied to boundary modeling codes and shown to achieve variance reductions with fewer high-fidelity boundary simulations. Key findings highlight the challenges of resolving the ITEP gap to find suitable balance between wall and divertor loads, neutron heating, and practical limits of PFC cooling. Next step priorities are to develop automated workflows to check boundary code convergence and detachment, implement tighter physics-engineering CAD provenance tracking, and inclusion of plasma-material interface models for SLAG and tungsten cracking behavior. Collectively, these developments establish sophisticated capabilities for predictive, multi-fidelity, whole-device modeling that integrates plasma physics, materials, magnets, and nuclear engineering to guide pathways to viable Fusion Pilot Plant design points.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗