Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

QuGrav: Bringing gravitational waves to light with qumodes

We propose using qumodes, quantum bosonic modes, for detecting high-frequency gravitational waves via the inverse Gertsenshtein effect, where a gravitational wave resonantly converts into a single photon in a magnetized cavity. For an occupation number n of the photon field in a qumode, the conversion probability is enhanced by a factor of n + 1 due to Bose-Einstein statistics. Unlocking this increased sensitivity entails the ability to continuously prepare the qumode and perform nondemolition measurement on the qumode-qubit system within the qumode coherence time. Our results indicate that, at microwave frequencies and with existing technology, the proposed setup can attain sensitivities within 1.7 orders of magnitude of the cosmological bound. With anticipated near-future improvements, it has the potential to surpass this limit and pave the way for the first exploration of high-frequency cosmological gravitational wave backgrounds. At optical frequencies, it can enhance the sensitivity of current detectors by one order of magnitude. That further enhances their potential in reaching the single-graviton level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-speed fiber-coupled terahertz time-domain spectroscopy system using a bias-free plasmonic source

We demonstrate a high-speed fiber-coupled terahertz time-domain spectroscopy (THz-TDS) system using a bias-free plasmonic terahertz source. The system is powered by a compact, low-power femtosecond fiber laser oscillator that drives a dual-branch fiber amplifier to pump and probe a plasmonic terahertz source and detector, respectively. A polarization-maintaining, fiber-coupled optical delay line is employed to precisely control the temporal offset between the pump and probe beams through a compact, robust platform. Operating in the self-similar amplification regime, the fiber amplifiers are engineered to mitigate nonlinear pulse distortion and dispersion while delivering robust, high-energy pulses at a 1560-nm wavelength, with an output power exceeding 326 mW. In reflection mode, the THz-TDS system achieves a peak dynamic range of 81 dB and a bandwidth greater than 3.5 THz at a scan rate of 3.75 Hz. The utility of the system for rapid sensing is further demonstrated by quantifying the porosity and density of pharmaceutical tablets through measurements of their physical thickness and effective refractive index.

Jiang, Xinghe [University of California, Los Angel↗

Overview of the Optical Design of the CMB-S4 Large Aperture Telescopes and Camera Optics

CMB-S4, the next-generation CMB observatory, will deploy hundreds of thousands of detectors to enable mapping the millimeter-wavelength sky with unprecedented speed. The large aperture telescopes for CMB-S4 consist of six-meter diameter crossed Dragone designs and a five-meter diameter three-mirror anastigmat. The two-mirror crossed Dragone design requires astigmatism corrections in the refractive optics to achieve diffraction-limited performance. We present biconic lens corrections for the CMB-S4 crossed Dragone camera optics and compare these designs to the camera optics for the three mirror anastigmat, as the optical designs of the cameras for these telescopes are being prototyped.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector architecture and data flow of the CMS HGCAL Phase-2 Endcap Calorimeter Upgrade

The CMS High Granularity Calorimeter (HGCAL) is the Phase-2 endcap calorimeter upgrade for the High-Luminosity Large Hadron Collider, designed to provide precise spatial, energy, and timing measurements in a high-radiation, high-pileup environment. This work presents an overview of the HGCAL assembly process, detector architecture, and end-to-end data flow. The data flow goes from signal generation in silicon sensors and scintillator tiles through front-end electronics, optical transmission, and back-end data acquisition. The study highlights how the integrated detector, electronics, and readout systems enable efficient event reconstruction and support the physics objectives of the HL-LHC.

Osei Boakye, Prince [Grambling State U.]↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Redefining precision interferometry and spectroscopy with high-performance optical interference coatings

High-performance optical interference coatings have transformed precision interferometry and spectroscopy by enabling unparalleled control over light–matter interactions. This review explores recent innovations in ion-beam sputtered amorphous dielectric, as well as substrate-transferred crystalline coatings, and their impact on systems at the forefront of precision metrology. These state-of-the-art coating techniques generate multilayers with ultralow optical losses, yielding mirrors with exceptional reflectivity. Refinements in their noise performance push the ultimate limits of sensitivity, resolution, and stability in demanding laser-based metrology applications. These technologies underpin the most advanced timekeeping and spatial measurement tools, enabling high-finesse reference cavities for the world’s most precise optical atomic clocks and low-noise reflective test masses for km-baseline gravitational-wave detectors. Emerging hybrid designs combining these techniques expand access to the mid-infrared spectral region, enabling the first ultralow-optical-loss coatings in the 3000–5000 nm wavelength range for enhanced spectroscopy and trace-gas detection. We highlight how these technologies redefine coating performance metrics and set new benchmarks in quantum science, fundamental physics, and precision optical sensing.

Cole, Garrett D. [University of Arizona, Tucson, A↗

The Simons Observatory: Design, Optimization, and Performance of Low-Frequency Detectors

The Simons Observatory (SO) is a cosmic microwave background (CMB) experiment located in the Atacama Desert in Chile that will make precise temperature and polarization measurements over six spectral bands ranging from 27 to 285 GHz. Three small aperture telescopes (SATs) and one large aperture telescope (LAT) will house ~60,000 detectors and cover angular scales between one arcminute and tens of degrees. We present the performance of the dichroic, low-frequency (LF) lenslet-coupled sinuous antenna transition-edge sensor (TES) bolometer arrays with bands centered at 27 and 39 GHz. The LF focal plane will primarily characterize Galactic synchrotron emission as a critical part of foreground subtraction from CMB data. We will discuss the design, optimization, and current testing status of these pixels.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvements to the characterization of Agfa x-ray film for use on opacity spectroscopy diagnostics

The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. In conclusion, when the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.

47 OTHER INSTRUMENTATION↗

Calibration of a broadband x-ray crystal spectrometer using a continuum x-ray source and photon-counting detectors

We report measurements of sensitivity of a broadband (≃20–30 keV) x-ray crystal spectrometer using a bremsstrahlung continuum x-ray source and several detectors, including an energy-discriminating photon-counting point detector (Si drift diode, Amptek Inc.), imaging hybrid photon-counting detectors (Eiger2-Si and Eiger2-CdTe, DECTRIS Ltd.), and image plates (SR type). Sensitivity is defined as a ratio of the crystal-reflected energy-position-dispersed spectrum measured by a given detector to the incident non-dispersed spectrum measured using the energy-discriminating point detector. The sensitivity derived from data measured exclusively by the point detector is considered detector-independent and serves as a reference. The sensitivities derived from data collected with the hybrid photon-counting detectors were matched to the reference using a scale factor of 1.05. The image plate-derived sensitivities required a scale factor of 1.16 to match the reference. Furthermore, the resulting mismatch in the shapes of all measured scaled sensitivities in the range of the spectrometer was ≲±10%, while the mismatch between the shapes of the sensitivities corresponding to the Si-based detectors was ≲±2.5%.

Crystal optics↗

Broadband optical modulation and control at millikelvin temperatures

A universal experimental challenge in studying radiation effects on cryogenic devices is precisely and accurately characterizing the position-dependent device response near the energy detection threshold. Here, we have developed a compact cryogenic optical beam steering system that can be used to generate O (μs) pulses of small numbers of photons over the energy range of 1.3–3.4 eV at room temperature, and deliver those photons via fiber optic to any specified location on the surface of a detector operating at cryogenic temperatures. This new system will allow for robust calibration of any photon-sensitive detector, including superconducting devices. The system can be used efficiently to explore the physics of target materials, quantify the position sensitivity of different sensor designs, measure phonon transport, and study the effects of quasiparticle poisoning on detector operation. We describe the design of this pulsed calibration method and present first results obtained with a second-generation system operated at room temperature and sub-Kelvin temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deployment of POLARBEAR-2b

POLARBEAR-2b (PB-2b) is the second receiver in the Simons Array, a cosmic microwave background (CMB) polarization experiment. The Simons Array uses dichroic polarization sensitive lenslet-coupled sinuous antennas and transition-edge sensor (TES) bolometers made of superconducting films. These bolometers are read out with frequency multiplexing electronics. PB-2b contains ~7500 detectors in two bands at 90 and 150 GHz with arcminute resolution. The polarization of these detectors is modulated by a cryogenic continuously rotating half-wave plate. PB-2b was installed on its telescope in 2022 in the Atacama Desert at an altitude of 5.2 km. This paper will detail initial readout commissioning, test of a new loopgain monitoring method, and focusing the optics. Work is ongoing to commission the remaining ambient temperature readout electronics, measure detector time constants, and observe with the cryogenic half-wave plate spinning.

47 OTHER INSTRUMENTATION↗

TTDAQ: A Continuous Flow, Timing and Trigger DAQ System

Final Scientific/Technical Report for DOE Award DE-SC0019581, “TTDAQ: A Continuous Flow, Timing and Trigger DAQ System.” The report summarizes Telluric Labs’ Phase II STTR work developing silicon-photonic building blocks for a software-defined, continuous-flow, trigger-less data acquisition system for next-generation high-energy and nuclear-physics detectors. The project focused on radiation-hard photonic integrated circuits, remote optical illumination, dense wavelength-division multiplexing, and a differential microring-resonator transceiver architecture designed to improve high-speed optical link stability and bandwidth. The report describes project objectives, technical accomplishments, AIM Photonics tape-outs, bench characterization, radiation-hardness testing, deferred integration work, and potential applications beyond physics readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light detection and cosmic rejection in the ICARUS LArTPC at Fermilab

Abstract The ICARUS-T600 detector is a 760-ton Liquid Argon Time Projection Chamber (LArTPC) currently operating at Fermilab as the Far Detector in the Short Baseline Neutrino (SBN) program. The SBN program is composed of three LArTPCs with a central goal of testing the sterile neutrino hypothesis. After operating for 3-years in the Gran Sasso Underground Laboratory, the ICARUS detector was shipped to CERN where it was outfitted with 360 8” Photomultiplier Tubes (PMTs) for a new optical detection system. The PMT system detects fast scintillation light from charged particles interacting in the Liquid Argon, generating the trigger signal for the full detector and allows 3D reconstruction of events. Now operating at shallow depth, the detector is exposed to a high flux of cosmic rays that can fake neutrino interactions. To mitigate this effect a Cosmic Ray Tagger (CRT) and a 3-meter-thick concrete were installed. Precise timing information from both the PMT and CRT subsystems can help to identify whether an interaction originated from inside or outside of the ICARUS cryostat. This paper reviews a method for cosmogenic background reduction and timing calibration of the CRT and PMT light detection systems in ICARUS.

Instruments & Instrumentation↗

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

FOS: Physical sciences↗

Refinement and Modeling of a Blackbody-Based Calibration Method in the InfraBREAD Detector

The Broadband Reflector Experiment for Axion Detection (BREAD) is an ongoing experiment searching for the conversion of yet undiscovered axion-like dark matter particles to photons in the presence of a magnetic field. InfraBREAD, a sub-experiment of BREAD, uses a superconducting nanowire single photon detector (SNSPD), a high-efficiency and low-noise device, to specifically detect infrared-range photons produced by $\mathcal{O}$(eV) axion-like particles. The unique BREAD reflector setup allows for the focusing of all converted signal photons to a 1mm $\times$ 1mm SNSPD. However, when the detector is cooled to cryogenic temperatures during operation, uneven thermal contraction of reflector components may lead to a small shift in the location of the focal spot. A novel calibration method using blackbody radiation is proposed to locate the true focal spot of the detector \textit{in situ}. Through ray tracing simulations done in FRED Optical Engineering Software, this method is demonstrated to locate the focus to within 50 $\mu$m in three dimensions.