Search NASA⌕ Search

SEARCH · Search NASA

Results for “component reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2012

This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2012 for the component reliability as reported in the Equipment Performance and Information Exchange (EPIX). The TDP failure modes considered are failure to start, failure to run less than or equal to 1 hour, failure to run more than 1 hour, and (for normally running systems) failure to run. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. No statistically significant increasing trends were identified in the TDP results. Statistically significant decreasing trends were identified for TDP run hours per reactor critical year and start demands.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hydrogen Equipment Enclosure Risk Reduction through Earlier Detection of Component Failures

Hydrogen component reliability and the hazard associated with failure rates is a critical area of research for the successful implementation and growth of hydrogen technology across the globe. The research team has partnered to quantify system risk reduction through earlier detection of hydrogen component failures. A model of hydrogen dispersion in a hydrogen equipment enclosure has been developed utilizing experimentally quantified hydrogen component leak rates as inputs. This model provides insight into the impact of hydrogen safety sensors and ventilation on the flammable mass within a hydrogen equipment enclosure. This model also demonstrates the change in safety sensor response time due to detector placement under various leak scenarios. The team looks to improve overall hydrogen system safety through an improved understanding of hydrogen component reliability and risk mitigation methods. This collaboration fits under the work program of IEA Hydrogen Task 43 Subtask E Hydrogen System Safety.

CFD↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998–2016

This report presents an enhanced performance evaluation of motor-driven pumps (MDP) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2016 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The motor-driven pump failure modes considered for standby systems are failure to start, failure to run less than or equal to one hour, and failure to run more than one hour; for normally running systems, the failure modes considered are failure to start and failure to run. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Highly statistically significant increasing trend was identified in normally running MDP run hours per reactor year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2013

This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2013 for the component reliability as reported in the Institute of Nuclear Power Operations Consolidated Events Database. The TDP failure modes considered are failure to start, failure to run less than or equal to 1 hour, failure to run more than 1 hour, and (for normally running systems) failure to run. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Statistically significant increasing trends were identified for TDP unavailability, for frequency of start demands for standby TDPs, and for run hours in the first hour after start. Statistically significant decreasing trends were identified for start demands for normally running TDPs, and for run hours per reactor critical year for normally running TDPs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhanced Component Performance Study: Air-Operated Valves 1998–2012

This report presents an enhanced performance evaluation of air-operated valves (AOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2012 for the component reliability as reported in the Equipment Performance and Information Exchange (EPIX). Results (beta distributions for failure probabilities upon demand and gamma distributions for rates) are used as inputs to the U.S. Nuclear Regulatory Commission standardized plant analysis risk models of U.S. commercial nuclear power plants. The AOV failure modes considered are failure-to-open/close, failure to operate or control, and spurious operation. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. No statistically significant increasing trends were identified in the AOV results. Statistically significant decreasing trends were identified in two areas: AOV operation demands less than or equal to 20 demands per year and greater than 20 demands.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2014

This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2014 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The TDP failure modes considered are failure to start (FTS), failure to run less than or equal to one hour (FTR=1H), failure to run more than one hour (FTR>1H), and normally running systems FTS and failure to run (FTR). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Statistically significant increasing trends were identified for TDP unavailability, for frequency of start demands for standby TDPs, and for run hours in the first hour after start. Statistically significant decreasing trends were identified for start demands for normally running TDPs, and for run hours per reactor critical year for normally running TDPs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998–2013

This report presents an enhanced performance evaluation of motor-driven pumps at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2013 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The motor-driven pump failure modes considered for standby systems are failure to start, failure to run less than or equal to 1 hour, and failure to run more than 1 hour; for normally running systems, the failure modes considered are failure to start and failure to run. An 8 hr unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. One statistically significant increasing trend was identified in the standby pump run hours per reactor year. Statistically significant decreasing trends were identified for standby systems industry-wide frequency of start demands, run hours per reactor year for runs of less than or equal to 1 hour, and frequency of fail to start events per reactor year.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998–2012

This report presents an enhanced performance evaluation of motor-driven valves (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2012 for the component reliability as reported in the Equipment Performance and Information Exchange (EPIX). The MDP failure modes considered for standby systems are failure to start, failure to run less than or equal to 1 hour, and failure to run more than 1 hour; for normally running systems, the failure modes considered are failure to start and failure to run. An 8 hr unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. One statistically significant increasing trend was identified in the MDP results for standby MDP run hours per reactor critical year. Statistically significant decreasing trends were identified for unreliability (for standby and normally running systems) frequency of failure-to-start events for standby systems and failure probability for standby systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Beyond a series of security nets: Applying STAMP & STPA to port security

Port security is an increasing concern considering the significant role of ports in global commerce and today’s increasingly complex threat environment. Current approaches to port security mirror traditional models of accident causality -- ‘a series of security nets’ based on component reliability and probabilistic assumptions. Traditional port security frameworks result in isolated and inconsistent improvement strategies. Recent work in engineered safety combines the ideas of hierarchy, emergence, control and communication into a new paradigm for understanding port security as an emergent complex system property. The ‘System-Theoretic Accident Model and Process (STAMP)’ is a new model of causality based on systems and control theory. The associated analysis process -- System Theoretic Process Analysis (STPA) -- identifies specific technical or procedural security requirements designed to work in coordination with (and be traceable to) overall port objectives. This process yields port security design specifications that can mitigate (if not eliminate) port security vulnerabilities related to an emphasis on component reliability, lack of coordination between port security stakeholders or economic pressures endemic in the maritime industry. As a result, this article aims to demonstrate how STAMP’s broader view of causality and complexity can better address the dynamic and interactive behaviors of social, organizational and technical components of port security.

97 MATHEMATICS AND COMPUTING↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998–2014

This report presents an enhanced performance evaluation of motor-driven pumps at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2014 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The motor-driven pump failure modes considered for standby systems are failure to start, failure to run less than or equal to one hour, and failure to run more than one hour; for normally running systems, the failure modes considered are failure to start and failure to run. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Statistically significant increasing trends were identified in pump run hours per reactor year. Statistically significant decreasing trends were identified for standby systems industry-wide frequency of start demands, and run hours per reactor year for runs of less than or equal to one hour.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Fidelity Simulation of Flow-Induced Vibrations in Helical Steam Generators for Small Modular Reactors

Flow-induced vibration (FIV) is a widespread problem in energy systems as they rely on fluid movement for energy conversion. Vibrating structures may be damaged as fatigue or wear occur. Given the importance of reliable components in the nuclear industry, FIV has long been a major concern in the safety and operation of nuclear reactors. In particular, nuclear fuel rods and steam generators have been known to suffer from FIV and related failures. In this paper we discuss the use of the computational fluid dynamics code Nek5000 coupled to the structural code Diablo to simulate the flow in helical coil heat exchangers and associated FIV. In particular, one-way coupled calculations are performed, where pressure and tractions data are loaded into the structural model. The main focus of this paper is on validation of this capability. Fluid-only Nek5000 large eddy simulations are first compared against dedicated high-resolution experiments. Then, one-way coupled calculations are performed with Nek5000 and Diablo for two data sets that provide FIV data for validation. These calculations were aimed at simulating available legacy FIV experiments in helical steam generators in the turbulent buffeting regime. In this regime one-way coupling is judged sufficient since the pressure loads do not cause substantial displacements. It is also the most common source of vibration in helical steam generators at the low flows expected in integral pressurized water reactors. We discuss validation of two-way coupled experiments and benchmarks toward the simulation of fluid elastic instability. We briefly discuss the application of these methods to grid-to-rod fretting.

Flow-Induced Vibration↗

Reliability Effects of Surge Current Testing of Solid Tantalum Capacitors

Solid tantalum capacitors are widely used in space applications to filter low-frequency ripple currents in power supply circuits and stabilize DC voltages in the system. Tantalum capacitors manufactured per military specifications (MIL-PRF-55365) are established reliability components and have less than 0.001% of failures per 1000 hours (the failure rate is less than 10 FIT) for grades D or S, thus positioning these parts among electronic components with the highest reliability characteristics. Still, failures of tantalum capacitors do happen and when it occurs it might have catastrophic consequences for the system. This is due to a short-circuit failure mode, which might be damaging to a power supply, and also to the capability of tantalum capacitors with manganese cathodes to self-ignite when a failure occurs in low-impedance applications. During such a failure, a substantial amount of energy is released by exothermic reaction of the tantalum pellet with oxygen generated by the overheated manganese oxide cathode, resulting not only in destruction of the part, but also in damage of the board and surrounding components. A specific feature of tantalum capacitors, compared to ceramic parts, is a relatively large value of capacitance, which in contemporary low-size chip capacitors reaches dozens and hundreds of microfarads. This might result in so-called surge current or turn-on failures in the parts when the board is first powered up. Such a failure, which is considered as the most prevalent type of failures in tantalum capacitors [I], is due to fast changes of the voltage in the circuit, dV/dt, producing high surge current spikes, I(sub sp) = Cx(dV/dt), when current in the circuit is unrestricted. These spikes can reach hundreds of amperes and cause catastrophic failures in the system. The mechanism of surge current failures has not been understood completely yet, and different hypotheses were discussed in relevant literature. These include a sustained scintillation breakdown model [1-3]; electrical oscillations in circuits with a relatively high inductance [4-6]; local overheating of the cathode [5,7, 8]; mechanical damage to tantalum pentoxide dielectric caused by the impact of MnO2 crystals [2,9, 10]; or stress-induced-generation of electron traps caused by electromagnetic forces developed during current spikes [11]. A commonly accepted explanation of the surge current failures is that at unlimited current supply during surge current conditions, the self-healing mechanism in tantalum capacitors does not work, and what would be a minor scintillation spike if the current were limited, becomes a catastrophic failure of the part [l, 12]. However, our data show that the scintillation breakdown voltages are significantly greater that the surge current breakdown voltages, so it is still not clear why the part, which has no scintillations, would fail at the same voltage during surge current testing (SCT).

Teverovsky, Alexander↗

A Bayesian inferencing framework for ultrasound wave speed measurements in metal additive manufacturing

Process-related changes during metal additive manufacturing introduce microstructural variability in the material properties of printed parts, directly affecting component reliability. Accurate estimation of these property variations with part performance are essential for quality assurance. Ultrasound testing offers a non-destructive means to estimate mechanical properties and detect defects; however, conventional analysis methods often neglect the influence of microstructural variability, limiting their effectiveness. Here, this research presents a Bayesian inference technique for quantifying wave speed uncertainty from ultrasound measurements of metal additive manufactured parts. By integrating prior ultrasound data with a Bayesian model, the proposed approach generates posterior density estimates of wave speed that systematically account for manufacturing-induced variability and uncertainty. The novelty of this research lies in applying a Bayesian framework to analyze experimental ultrasound measurements within the context of metal additive manufacturing variability. The method enhances the accuracy of wave speed estimation by 64%, defect position by 50% and increases confidence associated with wave speed variance by 30% across different porosity levels, thereby providing a robust foundation for improved decision-making and increased reliability in additively manufactured components.

Additive manufacturing↗

Development of Agile and Cost Effective Routes for Manufacturing Reliable Ceramic Components for SOFC Systems

Additive manufacturing routes were explored and developed to enable the low to medium volume manufacturing of ceramic components with a short lead time, flexibility for iterative design, and without the high CAPEX and tooling costs associated with green machining or injection molding. Agile manufacturing route of gelcasting and 3D printing were selected and work focused on the production of ceramic manifold components utilized in the balance of plant for Saint-Gobain’s all ceramic SOFC stack. This work showed that both gelcasting and a specific version of 3D printing were able to create parts with the proper fidelity and at lower cost than traditional powder processing followed by green machining.

36 MATERIALS SCIENCE↗

Development of Agile and Cost Effective Routes for Manufacturing Reliable Ceramic Components for SOFC Systems (Final Report)

Additive manufacturing routes were explored and developed to enable the low to medium volume manufacturing of ceramic components with a short lead time, flexibility for iterative design, and without the high CAPEX and tooling costs associated with green machining or injection molding. Agile manufacturing route of gelcasting and 3D printing were selected and work focused on the production of ceramic manifold components utilized in the balance of plant for Saint-Gobain’s all-ceramic SOFC stack. This work showed that both gelcasting and a specific version of 3D printing were able to create parts with the proper fidelity and at lower cost than traditional powder processing followed by green machining.

03 NATURAL GAS↗

Development of Agile and Cost Effective Routes for Manufacturing Reliable Ceramic Components for SOFC Systems (Final Scientific Report Updated)

Additive manufacturing routes were explored and developed to enable the low to medium volume manufacturing of ceramic components with a short lead time, flexibility for iterative design, and without the high CAPEX and tooling costs associated with green machining or injection molding. Agile manufacturing route of gelcasting and 3D printing were selected and work focused on the production of ceramic manifold components utilized in the balance of plant for Saint-Gobain’s all-ceramic SOFC stack. This work showed that both gelcasting and a specific version of 3D printing were able to create parts with the proper fidelity and at lower cost than traditional powder processing followed by green machining.

36 MATERIALS SCIENCE↗

Future challenges in V/STOL flight propulsion control integration

A survey of propulsion control requirements forming part of an advanced V/STOL control requirements study has to date determined, among other findings: (1) that the dependence of V/STOL flying qualities on propulsive lift makes it necessary to identify propulsion control requirements early in a development program; (2) that V/STOL controls of the future should relieve the pilot of control functions and elevate him to the position of a flight operations manager, with substantial gains in capability and/or safety; and (3) that research is required to define the V/STOL control system reliability requirements and specific component reliability allocations. An interactive, integrated design process for the realization of these objectives is also described.

Roth, S. P.↗

Design and dynamic testing of an instrumented spacecraft component

Details relating to the design and subsequent vibration and shock tests of a spacecraft component for a severe vibration and shock environment are presented. The design process and analysis method involve the use of finite element analysis coupled with the Modal Strain Energy method with risk graphs to determine the adequacy of the design. The vibration levels experienced by box parts are reduced by the application of passive constrained layer viscoelastic treatments that significantly improve component reliability. All significant internal components were fully instrumented in both the random vibration and shock tests, the latter being done on a mechanical impact pyro simulator. Correlation between analysis and test data is good, validating the modeling and analysis techniques.

Dwyer, Thomas J.↗