Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Thermal imaging of graphite/epoxy composite samples with fabricated defects

Consideration is given to a thermal inspection system for quickly inspecting large area composites for increased reliability and maintainability of helicopters resulting from improved quality assurance manufacturing. The infrared camera/image processor-based inspection system was used to image defects in composites. Noncontacting and single-sided measurements were performed on graphite/epoxy samples with fiber volume fraction variations, fabricated porosity, impact damage, and inclusions in incurred lay ups. These defects were imaged by determining the variations in the cooling rates caused by differences in through ply thermal diffusivity. Attention is also given to the system's sensitivity to measuring the defects due to sample thickness.

Zalameda, Joseph N.↗

Application of Perona Malik anisotropic diffusion on digital radiographic image

Perona Malik Anisotropic Diffusion (PMAD) is a very useful and efficient denoising technique if the parameters are properly selected. Overestimating the parameters may cause oversmoothed and underestimating it may leave unfiltered noise. This makes the selection of parameters a crucial process. In this paper the PMAD model is solved using a finite difference scheme The discretized model is evaluated using different diffusion coefficient of exponential and quadratic on defective radiographic images in terms of quality and efficiency. In the application of the PMAD model on image data, a set of defective radiographic images of welding is used as input data. Peak Signal to Noise Ratio (PSNR), Structural Similarity Measure (SSIM) and temporal time are used to evaluate the performance of the model. The implementation of the experiment has been carried out using MATLAB R2009a. In terms of quality, results show that the Quadratic Diffusion Coefficient Function (QDCF) provides better results compared with the Exponential Diffusion Coefficient Function (EDCF). In conclusion, the denoising effect using PMAD model based on finite difference scheme shows able to improve image quality by removing noise in the defective radiographic image.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electroluminescence Imaging: A Study in the Impact of Microscopic Surface Defects

Electroluminescence (EL) imaging can be used as a quantitative characterization method for solar cell performance when combined with image processing, allowing for the impact of dust grain size on electroluminescence imaging characteristics to be investigated. Simulating these results via modelling can help to predict what dust grain sizes, if any, will have a greater impact on performance.

photovoltaics↗

Identifying Defects with Guided Algorithms in Bragg Coherent Diffractive Imaging

In this study, crystallographic defects such as dislocations can significantly alter material properties and functionality. However, imaging these imperfections during operation remains challenging due to the short length scales involved and the reactive environments of interest. Bragg coherent diffractive imaging (BCDI) has emerged as a powerful tool capable of identifying dislocations, twin domains, and other defects in 3D detail with nanometer spatial resolution within nanocrystals and grains in reactive environments. However, BCDI relies on phase retrieval algorithms that can fail to accurately reconstruct the defect network. Here, we use numerical simulations to explore different guided phase retrieval algorithms for imaging defective crystals using BCDI. We explore different defect types, defect densities, Bragg peaks, and guided algorithm fitness metrics as a function of signal-to-noise ratio. Based on these results, we offer a general prescription for phasing of defective crystals with no a prior knowledge.

36 MATERIALS SCIENCE↗

Multi-Task Learning of Scanning Electron Microscopy and Synthetic Thermal Tomography Images for Detection of Defects in Additively Manufactured Metals

One of the key challenges in laser powder bed fusion (LPBF) additive manufacturing of metals is the appearance of microscopic pores in 3D-printed metallic structures. Quality control in LPBF can be accomplished with non-destructive imaging of the actual 3D-printed structures. Thermal tomography (TT) is a promising non-contact, non-destructive imaging method, which allows for the visualization of subsurface defects in arbitrary-sized metallic structures. However, because imaging is based on heat diffusion, TT images suffer from blurring, which increases with depth. We have been investigating the enhancement of TT imaging capability using machine learning. In this work, we introduce a novel multi-task learning (MTL) approach, which simultaneously performs the classification of synthetic TT images, and segmentation of experimental scanning electron microscopy (SEM) images. Synthetic TT images are obtained from computer simulations of metallic structures with subsurface elliptical-shaped defects, while experimental SEM images are obtained from imaging of LPBF-printed stainless-steel coupons. MTL network is implemented as a shared U-net encoder between the classification and the segmentation tasks. Results of this study show that the MTL network performs better in both the classification of synthetic TT images and the segmentation of SEM images tasks, as compared to the conventional approach when the individual tasks are performed independently of each other.

36 MATERIALS SCIENCE↗

Real-Time Defect Correction in Large-Scale Polymer Additive Manufacturing via Thermal Imaging and Laser Profilometer

Defects can result in a failed part and are costly in terms of time and material. This cost is even greater in the context of large-scale additive manufacturing where the objects can be very large. As a result, a great deal of research has focused on defect identification and mitigation. To address defects during object construction, researchers at Oak Ridge National Laboratory’s Manufacturing Demonstration Facility investigated an in-situ control system comprised of two sensors: a thermal camera and laser profilometer. This control system adjusted material flow and build speed to mitigate three types of defects: low layer times, underfill, and overfill. Several test objects were constructed. The control system was found to adjust build parameters to handle low layer times of approximately 15 seconds and height deviations from -100% underfill (the absence of a layer) to 50% overfill. Within two layers, height deviations could be returned to within 10% of the expected layer height. Further, preliminary results suggest the system can compensate for uneven build surfaces.

Borish, Michael↗

Defect Detection of Industrial Radiography Images of Ammonia Pipes by a Sparse Coding Model

Pipeline transportation systems for liquid anhydrous ammonia require periodic inspections for pipe defects. Defects such as crack-like flaws, including those due to stress corrosion and fatigue crack growth and fatigue of welded joints, can be tested by in situ radiography testing (RT). It is required that the detection technique should reveal the defect region without any significant distortion. Imaging noise such as that due to radiation scattering reduces contrast over the whole or part of the image, causing a reduction in image quality. Various image processing methods can be utilized to improve the outcome of RT of pipes. The sparse coding model is a powerful contrast improvement algorithm, but it tends to eliminate imaging details, passing them off as noise. We present a novel implementation of the sparse coding model based on a probabilistic interpretation to improve defect detection in ammonia pipelines radiography images. The performance of this procedure was evaluated in radiographic images of defect and corrosion regions for different pipe types. For ammonia pipes, the technique was found to offer a significant improvement in defect detection while preserving imaging details.

42 ENGINEERING↗

3D Bragg Coherent Diffraction Imaging of Extended Nanowires: Defect Formation in Highly Strained InGaAs Quantum Wells

InGaAs quantum wells embedded in GaAs nanowires can serve as compact near-infrared emitters for direct integration onto Si complementary metal oxide semiconductor technology. While the core–shell geometry in principle allows for a greater tuning of composition and emission, especially farther into the infrared, the practical limits of elastic strain accommodation in quantum wells on multifaceted nanowires have not been established. One barrier to progress is the difficulty of directly comparing the emission characteristics and the precise microstructure of a single nanowire. Here, in this study, we report an approach to correlating quantum well morphology, strain, defects, and emission to understand the limits of elastic strain accommodation in nanowire quantum wells specific to their geometry. We realize full 3D Bragg coherent diffraction imaging (BCDI) of intact quantum wells on vertically oriented epitaxial nanowires, which enables direct correlation with single-nanowire photoluminescence. By growing In 0.2 Ga 0.8 As quantum wells of distinct thicknesses on different facets of the same nanowire, we identified the critical thickness at which defects are nucleated. A correlation with a traditional transmission electron microscopy analysis confirms that BCDI can image the extended structure of defects. Finite element simulations of electron and hole states explain the emission characteristics arising from strained and partially relaxed regions. This approach, imaging the 3D strain and microstructure of intact nanowire core–shell structures with application-relevant dimensions, can aid the development of predictive models that enable the design of new compact infrared emitters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Defect detection in atomic-resolution images via unsupervised learning with translational invariance

Abstract Crystallographic defects can now be routinely imaged at atomic resolution with aberration-corrected scanning transmission electron microscopy (STEM) at high speed, with the potential for vast volumes of data to be acquired in relatively short times or through autonomous experiments that can continue over very long periods. Automatic detection and classification of defects in the STEM images are needed in order to handle the data in an efficient way. However, like many other tasks related to object detection and identification in artificial intelligence, it is challenging to detect and identify defects from STEM images. Furthermore, it is difficult to deal with crystal structures that have many atoms and low symmetries. Previous methods used for defect detection and classification were based on supervised learning, which requires human-labeled data. In this work, we develop an approach for defect detection with unsupervised machine learning based on a one-class support vector machine (OCSVM). We introduce two schemes of image segmentation and data preprocessing, both of which involve taking the Patterson function of each segment as inputs. We demonstrate that this method can be applied to various defects, such as point and line defects in 2D materials and twin boundaries in 3D nanocrystals.

36 MATERIALS SCIENCE↗

Detection of defects in atomic-resolution images of materials using cycle analysis

The automated detection of defects in high-angle annular dark-field Z-contrast (HAADF) scanning-transmission-electron microscopy (STEM) images has been a major challenge. Here, we report an approach for the automated detection and categorization of structural defects based on changes in the material’s local atomic geometry. The approach applies geometric graph theory to the already-found positions of atomic-column centers and is capable of detecting and categorizing any defect in thin diperiodic structures (i.e., “2D materials”) and a large subset of defects in thick diperiodic structures (i.e., 3D or bulk-like materials). Despite the somewhat limited applicability of the approach in detecting and categorizing defects in thicker bulk-like materials, it provides potentially informative insights into the presence of defects. The categorization of defects can be used to screen large quantities of data and to provide statistical data about the distribution of defects within a material. This methodology is applicable to atomic column locations extracted from any type of high-resolution image, but here we demonstrate it for HAADF STEM images.

36 MATERIALS SCIENCE↗

Deterministic nanoscale quantum spin-defect implantation and diffraction strain imaging

Abstract Local crystallographic features negatively affect quantum spin defects by changing the local electrostatic environment, often resulting in degraded or varied qubit optical and coherence properties. Few tools exist that enable the deterministic synthesis and study of such intricate systems on the nano-scale, making defect-to-defect strain environment quantification difficult. In this paper, we highlight state-of-the-art capabilities from the U.S. Department of Energy’s Nanoscale Science Research Centers that directly address these shortcomings. Specifically, we demonstrate how complementary capabilities of nano-implantation and nano-diffraction can be used to demonstrate the quantum relevant, spatially deterministic creation of neutral divacancy centers in 4H silicon carbide, while investigating and characterizing these systems on the ≤ 25 nm scale with strain sensitivities on the order of 1 × 10 − 6 , relevant to defect formation dynamics. This work lays the foundation for ongoing studies into the dynamics and deterministic formation of low strain homogeneous quantum relevant spin defects in the solid state.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterizing Dislocation Defects in Dark Field X-ray Microscopy Images of Bulk Aluminum

Material defects play a large role in material response under shock loading, yet the process of how these defects initiate, propagate, and annihilate is not well understood. Using a newly developed diagnostic, dark field X-ray microscopy (DFXM), we can now visualize the behavior of dislocation defects in materials at the mesoscale under varying conditions. Using data from the European Synchrotron Radiation Facility, we apply a variety of image processing techniques to capture relevant features to locate and characterize size and orientation of dislocation defects in bulk aluminum DFXM images. Beyond simple visualization, this analysis drives statistical characterization of the defects and their dynamic response to further improve the relevant physics models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Eliminating "Hotspots" in Digital Image Processing

Signals from defective picture elements rejected. Image processing program for use with charge-coupled device (CCD) or other mosaic imager augmented with algorithm that compensates for common type of electronic defect. Algorithm prevents false interpretation of "hotspots". Used for robotics, image enhancement, image analysis and digital television.

Salomon, P. M.↗

Influence of structural defects on charge density waves in 1T-TaS2

Abstract The influence of intrinsic defects of 1T-TaS 2 on charge density waves (CDWs) is studied using scanning tunneling microscopy and spectroscopy (STM, STS), angle-resolved photoelectron spectroscopy (ARPES), and density functional theory (DFT). We identify several types of structural defects and find that most have a local character limited to a single CDW site, with a single exception which effectively behaves as a dopant, leading to band-bending and affecting multiple neighboring sites. While only one type of defect can be observed by STM topographic imaging, all defects are easily resolved in STS mapping. Our results indicate modulation of the Mott band gap commensurate with the CDW and breaking of the three-fold symmetry of electronic states. DFT calculations (with included Coulomb interactions) are used to investigate the electronic structure, focusing on both sulfur vacancy and oxygen-sulfur substitution. The sulfur vacancy system, characterized with a metallic behavior, is identified as the origin of one of the experimentally observed defects. Additionally, the effect of oxidation of 1T-TaS 2 depends on the substitution site, leading to the heterogeneity of electronic properties.

Chemistry↗

Path-Integrated X-Ray Digital Image Correlation using Synthetic Reference Images

X-rays can provide images when an object is visibly obstructed, allowing for motion measurements via x-ray digital image correlation (DIC). However, x-ray images are path-integrated and contain data for all objects between the source and detector. If multiple objects are present in the x-ray path, conventional DIC algorithms may fail to correlate the x-ray images. A new DIC algorithm called path-integrated (PI)-DIC addresses this issue by reformulating the matching criterion for DIC to account for multiple, independently-moving objects. PI-DIC requires a set of reference x-ray images of each independent object. However, due to experimental constraints, such reference images might not be obtainable from the experiment. Here, this work focuses on the reliability of synthetically-generated reference images, in such cases. A simplified exemplar is used for demonstration purposes, consisting of two aluminum plates with tantalum x-ray DIC patterns undergoing independent rigid translations. Synthetic reference images based on the “as-designed” DIC patterns were generated. However, PI-DIC with the synthetic images suffered some biases due to manufacturing defects of the patterns. A systematic study of seven identified defect types found that an incorrect feature diameter was the most influential defect. Synthetic images were re-generated with the corrected feature diameter, and PI-DIC errors were improved by a factor of 3-4. Final biases ranged from 0.00-0.04 px, and standard uncertainties ranged from 0.06-0.11 px. In conclusion, PI-DIC accurately measured the independent displacement of two plates from a single series of path-integrated x-ray images using synthetically-generated reference images, and the methods and conclusions derived here can be extended to more generalized cases involving stereo PI-DIC for arbitrary specimen geometry and motion. This work thus extends the application space of x-ray imaging for full-field DIC measurements of multiple surfaces or objects in extreme environments where optical DIC is not possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Effect of Penetration Depth on Thermal Contrast of NDT by Thermography

Nondestructive evaluation by Thermography (TNDE) is generally classified into two categories, the passive approach and the active approach. The passive approach is usually performed by measuring the natural temperature difference between the ambient and the material or structure to be tested. The active approach, on the other hand, requires the application of an external energy source to stimulate the material for inspection. A laser, a heater, a hot air blower, a high power thermal pulse, mechanical, or electromagnetic energy may provide the energy sources. For the external heating method to inspect materials for defects and imperfection at ambient temperature, a very short burst of heat can be introduced to one of the surfaces or slow heating of the side opposite to the side being observed. Due to the interruption of the heat flow through the defects, the thermal images will reveal the defective area by contrasting against the surrounding good materials. This technique is called transient Thermography, pulse video Thermography, or thermal wave imaging. As an empirical rule, the radius of the smallest defect should be at least one to two times larger than its depth under the surface. Thermography is being used to inspect void, debond, impact damage, and porosity in composite materials. It has been shown that most of the defects and imperfection can be detected. However, the current method of inspection using thermographic technique is more of an art than a practical scientific and engineering approach. The success rate of determining the defect location and defect type is largely depend on the experience of the person who operates thermography system and performs the inspection. The operator has to try different type of heat source, different duration of its application time, as well as experimenting with the thermal image acquisition time and interval during the inspection process. Further-more, the complexity of the lay-up and structure of composites makes it more difficult to determine the optimal operating condition for revealing the defects. In order to develop an optimal thermography inspection procedure, we must understand the thermal behavior inside the material subjected to transient heat in order to interpret the thermal images correctly. Fabrication of finite element models of characteristic defects in composite materials subjected to transient heat will enable the development of appropriate procedure for thermography inspection. Design of phantom defects could be modeled and behavior characterized prior to physically building these test parts. Since production of phantom test parts can be very time consuming and laborious, it is important to design good representative defects.

Chu, Tsuchin Philip↗

Initial Assessment of X-Ray Computer Tomography image analysis for material defect microstructure

The original development work leading to this report was focused on the non destructive three-dimensional (3-D) characterization of nuclear graphite as a means to better understand the nature of the inherent pore structure. The pore structure of graphite and its evolution under various environmental factors such as irradiation, mechanical stress, and oxidation plays an important role in their observed properties and characteristics. If we are to transition from an empirical understanding of graphite behavior to a truly predictive mechanistic understanding the pore structure must be well characterized and understood. As the pore structure within nuclear graphite is highly interconnected and truly 3-D in nature, 3-D characterization techniques are critical. While 3-D characterization has been an excellent tool for graphite pore characterization, it is applicable to a broad number of materials systems over many length scales. Given the wide range of applications and the highly quantitative nature of the tool, it is quite surprising to discover how few materials researchers understand and how valuable of a tool 3-D image processing and analysis can be. Ultimately, this report is intended to encourage broader use of 3 D image processing and analysis in materials science and engineering applications, more specifically nuclear-related materials applications, by providing interested readers with enough familiarity to explore its vast potential in identifying microstructure changes. To encourage this broader use, the report is divided into two main sections. Section 2 provides an overview of some of the key principals and concepts needed to extract a wide variety of quantitative metrics from a 3-D representation of a material microstructure. The discussion includes a brief overview of segmentation methods, connective components, morphological operations, distance transforms, and skeletonization. Section 3 focuses on the application of concepts from Section 2 to relevant materials at Idaho National Laboratory. In this section, image analysis examples featuring nuclear graphite will be discussed in detail. Additionally, example analyses from Transient Reactor Test Facility low-enriched uranium conversion, Advanced Gas Reactor like compacts, and tristructural isotopic particles are shown to give a broader perspective of the applicability to relevant materials of interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P less than 0.00l). Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

Source record↗