Systems improved numerical differencing analyzer

Analyzer is software system that possesses capabilities which make it well suited for solving lumped-parameter representations of physical problems governed by diffusion-type equations, such as Fourier, Poisson, or La Place.

Fink, L. C.↗

Moving particle composition analyzer

A mass spectrometry apparatus for analyzing the composition of moving microscopic particles is introduced. The apparatus includes a capacitor with a front electrode upon which the particles impinge, a back electrode, and a solid dielectric sandwiched between the front and back electrodes. In one embodiment, the electrodes and dielectric are arcuately shaped as concentric peripheral segments of different spheres having a common center and different radii. The front electrode and dielectric together have a thickness such that an impinging particle can penetrate them. In a second embodiment, the capacitor has planar, parallel electrodes, in which case the ejected positive ions are deflected downstream of a planar grid by a pair of spaced, arcuate capacitor plates having a region between them through which the ejected ions travel.

Auer, S. O.↗

COREST: A FORTRAN computer program to analyze paralinear oxidation behavior and its application to chromic oxide forming alloys

A FORTRAN computer program (COREST) was developed to analyze the high-temperature paralinear oxidation behavior of metals. It is based on a mass-balance approach and uses typical gravimetric input data. COREST was applied to predominantly Cr2O3-forming alloys tested isothermally for long times. These alloys behaved paralinearly above 1100 C as a result of simultaneous scale formation and scale vaporization. Output includes the pertinent formation and vaporization constants and kinetic values of interest. COREST also estimates specific sample weight and specific scale weight as a function of time. Most importantly, from a corrosion standpoint, it estimates specific metal loss.

Barrett, C. E.↗

Composition analyzer for microparticles using a spark ion source

Iron microparticles were fired onto a capacitor-type microparticle detector which responded to an impact with a spark discharge. Ion currents were extracted from the spark and analyzed in a time-of-flight mass spectrometer. The mass spectra showed the elements of both detector and particle materials. The total extracted ion current was typically 10 A within a period of 100 nsec, indicating very efficient vaporization of the particle and ionization of the vapor. Potential applications include research on cosmic dust, atmospheric aerosols and cloud droplets, particles ejected by rocket or jet engines, by machining processes or by nuclear bomb explosions.

Auer, S.↗

Space Shuttle Trace Gas Analyzer

A Trace Gas Analyzer (TGA) with the ability to detect the presence of toxic contaminants in the Space Shuttle atmosphere within the subparts-per-million range is under development. The design is a modification of the miniaturized Gas Chromatograph-Mass Spectrometer (GCMS) developed for the Viking Mars Lander. An ambient air sample is injected onto the GC column from a constant volume sample loop and separated into individual compounds for identification by the MS. The GC-MS interface consists of an effluent divider and a silver-paladium separator, an electrochemical cell which removes more than 99.99% of the hydrogen carrier gas. The hydrogen is reclaimed and repressurized without affecting the separator efficiency, a feature which enables a considerable weight reduction in the carrier gas supply system.

Dencker, W.↗

Satellite-based interference analyzer

System identifies terrestrial sources of radiofrequency interference and measures their frequency spectra and amplitudes. Designed to protect satellite communication networks, system measures entire noise spectrum over selected frequency band and can raster-scan geographical region to locate noise sources. Once interference is analyzed, realistic interference protection ratios are determined and mathematical models for predicting ratio-frequency noise spectra are established. This enhances signal-detection and locates optimum geographical positions and frequency bands for communication equipment.

Varice, H.↗

Utility of a scanning densitometer in analyzing remotely sensed imagery

The utility of a scanning densitometer for analyzing imagery in the NASA Lewis Research Center's regional remote sensing program was evaluated. Uses studied include: (1) quick-look screening of imagery by means of density slicing, magnification, color coding, and edge enhancement; (2) preliminary category classification of both low- and high-resolution data bases; and (3) quantitative measurement of the extent of features within selected areas. The densitometer was capable of providing fast, convenient, and relatively inexpensive preliminary analysis of aerial and satellite photography and scanner imagery involving land cover, water quality, strip mining, and energy conservation.

Dooley, J. T.↗

The GSFC NASTRAN thermal analyzer new capabilities

An overview of four analysis capabilities, which developed and integrated into the NASTRAN Thermal Analyzer, is given. To broaden the scope of applications, these additions provide the NTA users with the following capabilities: (1) simulating a thermal louver as a means of the passive thermal control, (2) simulating a fluid loop for transporting energy as a means of the active thermal control, (3) condensing a large sized finite element model for an efficient transient thermal analysis, and (4) entering multiple boundary condition sets in a single submission for execution in steady state thermal analyses.

Lee, H. P.↗

Trace Gas Analyzer (TGA) program

The design, fabrication, and test of a breadboard trace gas analyzer (TGA) is documented. The TGA is a gas chromatograph/mass spectrometer system. The gas chromatograph subsystem employs a recirculating hydrogen carrier gas. The recirculation feature minimizes the requirement for transport and storage of large volumes of carrier gas during a mission. The silver-palladium hydrogen separator which permits the removal of the carrier gas and its reuse also decreases vacuum requirements for the mass spectrometer since the mass spectrometer vacuum system need handle only the very low sample pressure, not sample plus carrier. System performance was evaluated with a representative group of compounds.

Source record↗

NASTRAN thermal analyzer: Theory and application including a guide to modeling engineering problems, volume 2

A sample problem library containing 20 problems covering most facets of Nastran Thermal Analyzer modeling is presented. Areas discussed include radiative interchange, arbitrary nonlinear loads, transient temperature and steady-state structural plots, temperature-dependent conductivities, simulated multi-layer insulation, and constraint techniques. The use of the major control options and important DMAP alters is demonstrated.

Jackson, C. E., Jr.↗

Market study: Whole blood analyzer

A market survey was conducted to develop findings relative to the commercialization potential and key market factors of the whole blood analyzer which is being developed in conjunction with NASA's Space Shuttle Medical System.

Source record↗

Speech analyzer

A speech signal is analyzed by applying the signal to formant filters which derive first, second and third signals respectively representing the frequency of the speech waveform in the first, second and third formants. A first pulse train having approximately a pulse rate representing the average frequency of the first formant is derived; second and third pulse trains having pulse rates respectively representing zero crossings of the second and third formants are derived. The first formant pulse train is derived by establishing N signal level bands, where N is an integer at least equal to two. Adjacent ones of the signal bands have common boundaries, each of which is a predetermined percentage of the peak level of a complete cycle of the speech waveform.

Lokerson, D. C.↗

Metabolic analyzer

The metabolic analyzer was designed to support experiment M171. It operates on the so-called open circuit method to measure a subject's metabolic activity in terms of oxygen consumed, carbon dioxide produced, minute volume, respiratory exchange ratio, and tidal volume or vital capacity. The system operates in either of two modes. (1) In Mode I, inhaled respiratory volumes are actually measured by a piston spirometer. (2) In Mode II, inhaled volumes are calculated from the exhaled volume and the measured inhaled and exhaled nitrogen concentrations. This second mode was the prime mode for Skylab. Following is a brief description of the various subsystems and their operation.

Lem, J. D.↗

Results of the plasma analyzer experiment on Pioneers 10 and 11

The plasma-analyzer experiments on Pioneers 10 and 11 have determined that the characteristics of the solar-wind interaction with the Jovian magnetosphere are basically similar to those observed for the solar-wind interaction of earth and differ mainly in terms of the scale size of the interaction. The Jovian magnetosheath flow field and the calculated normals to the Jovian magnetosphere indicate that the Jovian magnetosphere is extremely thick and blunt in shape. The size of the Jovian magnetosphere in the sunward (dayside) direction can change by as much as a factor of two in response to relatively minor changes in solar-wind dynamic pressure. The outer dayside Jovian magnetosphere is inflated with a high-beta thermal plasma.

Intriligator, D. S.↗

Temperature, density, and composition in the disturbed thermosphere from Esro 4 gas analyzer measurements - A global model

An analysis of density measurements of Ar, N2, O, and He made at 280 km with the gas analyzer aboard the polar-orbiting satellite Esro 4 has yielded a global model of the variations in temperature, density, and composition that occur in the disturbed thermosphere. In the model the increase of temperature over quiet conditions is a nonlinear function of the planetary geomagnetic index, its latitude profile being approximated by a fourth-power sin phi law, where phi is the 'invariant' magnetic latitude. A density wave proceeding from high latitudes is approximated by a fourth power cos phi law. A strong nonlinearity in the relation between the temperature variations and the variations in the height of the homopause explains a previously found behavioral difference in the variation of atomic oxygen during magnetic storms and during periods of sustained geomagnetic activity.

Jacchia, L. G.↗

Adsorption of argon on sintered tin dioxide analyzed by several methods

Argon adsorption measurements are presented over a wide range of temperature and coverage on a series of three progressively sintered SnO2 surfaces. These data are analyzed by mercury porosimetry, the BET method, the CAEDMON distribution analysis, and the Singleton-Halsey equation. Isosteric heats are computed, and the high-temperature virial expansion of the data presented. The advantages and disadvantages of each method are discussed with particular attention to the ability of physical adsorption to discriminate among surfaces beyond the measurement of surface area.

Hinman, D. C.↗

Single particle aerodynamic relaxation time analyzer

An instrument employing a laser Doppler velocimeter and a microphone to measure the phase lag of the motion of aerosol particulates relative to the motion of the fluid medium within an acoustic field is described. The relaxation times and aerodynamic diameters of the particles or droplets are determined in real time from the measured values of phase lag; thus, the size analysis is independent of the electrostatic charges and refractive indices of the particulates. The instrument is suitable for analyzing the aerodynamic size spectrum of atmospheric particulate pollutants with aerodynamic diameters ranging from 0.1 to 10.0 microns.

Mazumder, M. K.↗