Search NASA⌕ Search

SEARCH · Search NASA

Results for “computer software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Parametric study of natural circulation flow in molten salt fuel in molten salt reactor

The Molten Salt Reactor (MSR) is one of the most promising system proposed by Generation IV Forum (GIF) for future nuclear reactor systems. Advantages of the MSR are significantly larger compared to other reactor system, and is mainly achieved from its liquid nature of fuel and coolant. Further improvement to this system, which is a natural circulating molten fuel salt inside its tube in the reactor core is proposed, to achieve advantages of reducing and simplifying the MSR design proposed by GIF. Thermal hydraulic analysis on the proposed system was completed using a commercial computation fluid dynamics (CFD) software called FLUENT by ANSYS Inc. An understanding on theory behind this unique natural circulation flow inside the tube caused by fission heat generated in molten fuel salt and tube cooling was briefly introduced. Currently, no commercial CFD software could perfectly simulate natural circulation flow, hence, modeling this flow problem in FLUENT is introduced and analyzed to obtain best simulation results. Results obtained demonstrate the existence of periodical transient nature of flow problem, hence improvements in tube design is proposed based on the analysis on temperature and velocity profile. Results show that the proposed system could operate at up to 750MW core power, given that turbulence are enhanced throughout flow region, and precise molten fuel salt physical properties could be defined. At the request of the authors and the Proceedings Editor the name of the co-author Andrea Cioncolini was corrected from Andrea Coincolini. The same name correction was made in the Acknowledgement section on page 030004-10 and in reference number 4. The updated article was published on 11 May 2015.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of periodically driven systems by x-ray absorption spectroscopy using asynchronous data collection mode

Here, we report the development, testing, and demonstration of a setup for modulation excitation spectroscopy experiments at the Inner Shell Spectroscopy beamline of National Synchrotron Light Source - II. A computer algorithm and dedicated software were developed for asynchronous data processing and analysis. We demonstrate the reconstruction of X-ray absorption spectra for different time points within the modulation pulse using a model system. This setup and the software are intended for a broad range of functional materials which exhibit structural and/or electronic responses to the external stimulation, such as catalysts, energy and battery materials, and electromechanical devices.

36 MATERIALS SCIENCE↗

Four-dimensional calibration turntable of the motional Stark effect diagnostic on EAST

The motional Stark effect (MSE) diagnostic is applied to measure the safety factor q and current density profile of a tokamak device, which are important parameters in realizing the high-performance and long-pulse steady state of a tokamak. A single-channel MSE diagnostic based on dual photoelastic modulators, whose sightline meets with the neutral beam injection at a major radius of R = 2.12 m, has been built for the D window of the Experimental Advanced Superconducting Tokamak (EAST). According to the requirements of MSE diagnostic polarimetric calibration, a high-precision four-dimensional calibration turntable, driven by four stepping motors and controlled by software running on the computer, was designed for EAST. The turntable allows us to rapidly calibrate the MSE diagnostic in a series of positions and angles during EAST maintenance. The turntable can move in four dimensions of translation, yaw, pitch, and roll of the polarizer and can create linearly polarized light at any given angle with accuracy of ~0.05° for the MSE system offline calibration. As a result, the experimental results of the MSE diagnostic calibration in the laboratory show that the turntable has the advantages of high positioning accuracy, flexible spatial movement, and convenient control and fully meets the calibration requirements of an MSE diagnosis system.

47 OTHER INSTRUMENTATION↗

High-resolution climate model datasets for energy infrastructure planning in a renewable-dependent future

Electrification and renewables deployment efforts are amplifying the interdependence of the climate and energy systems. Increases in climate model resolution, which is now approaching that of reanalysis datasets and operational weather forecast models, present a unique opportunity to use future climate projections for energy infrastructure planning. In this Perspective, we review recent developments in high-resolution climate modeling, which have been driven by increased computing power and advanced software tools. We then look ahead to discuss how high-resolution climate data can be used to plan for a renewable-dependent future, and envision a unified climate-energy model framework that captures the two-way feedbacks between these interdependent systems.

climate change↗

Using Amazon's Elastic Compute Cloud to dynamically scale CMS computational resources

Large international scientific collaborations such as the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider have traditionally addressed their data reduction and analysis needs by building and maintaining dedicated computational infrastructure. Emerging cloud computing services such as Amazon's Elastic Compute Cloud (EC2) offer short-term CPU and storage resources with costs based on usage. These services allow experiments to purchase computing resources as needed, without significant prior planning and without long term investments in facilities and their management. We have demonstrated that services such as EC2 can successfully be integrated into the production-computing model of CMS, and find that they work very well as worker nodes. The cost-structure and transient nature of EC2 services makes them inappropriate for some CMS production services and functions. We also found that the resources are not truely 'on-demand' as limits and caps on usage are imposed. Our trial workflows allow us to make a cost comparison between EC2 resources and dedicated CMS resources at a University, and conclude that it is most cost effective to purchase dedicated resources for the 'base-line' needs of experiments such as CMS. However, if the ability to use cloud computing resources is built into an experiment's software framework before demand requires their use, cloud computing resources make sense for bursting during times when spikes in usage are required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy

We describe the development, operation, and application of the 4D Camera—a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at ~480 Gbit/s which is captured by dedicated receiver computers with a parallelized software infrastructure that has been implemented to process the resulting 10–700 Gigabyte-sized raw datasets. The back illuminated detector provides the ability to detect single electron events at accelerating voltages from 30 to 300 kV. Through electron counting, the resulting sparse data sets are reduced in size by 10--300× compared to the raw data, and open-source sparsity-based processing algorithms offer rapid data analysis. The high frame rate allows for large and complex scanning diffraction experiments to be accomplished with typical scanning transmission electron microscopy scanning parameters.

47 OTHER INSTRUMENTATION↗

SYMBIOSYS: A Methodology for Performance Analysis of Composable HPC Data Services

Microservices are a powerful new way of building, customizing, and deploying distributed services owing to their flexibility and maintainability. Several large-scale distributed platforms have emerged to serve the growing needs of data-centric workloads and services in commercial computing. Concurrently, high-performance computing (HPC) systems and software are rapidly evolving to meet the demands of diversified applications and heterogeneity. The interplay of hardware factors, software configuration parameters, and the flexibility offered with a microservice architecture makes it nontrivial to estimate the optimal service instantiation for a given application workload. Further, this problem is exacerbated when considering that these services operate in a dynamic and heterogeneous HPC environment. An optimally integrated service can be vastly more performant than a haphazardly integrated one. Existing performance tools for HPC either fail to understand the request-response model of communication inherent to microservices or they operate within a narrow scope, limiting the insight that can be gleaned from employing them in isolation. We propose a methodology for integrated performance analysis of HPC microservices frameworks and applications called SYMBIOSYS. We describe its design and implementation within the context of the Mochi framework. This integration is achieved by combining distributed callpath profiling and tracing with a performance data exchange strategy that collects fine-grained, low-level metrics from the RPC communication library and network layers. The result is a portable, low-overhead performance analysis setup that provides a holistic profile of the dependencies among microservices and how they interact with the Mochi RPC software stack. Using HEPnOS, a production-quality Mochi data service, we demonstrate the low-overhead operation of SYMBIOSYS at scale and use it to identify the root causes of poorly performing service configurations.

microservices↗

Miniaturized Magnetoelastic Sensor System

This article describes the design, assembly, and implementation of a hand-held, magnetic-field-based sensor system that can be adapted for a variety of sensing applications. The miniaturized system is based on Chemical Identification by Magneto-Elastic Sensing (ChIMES) technology, which uses three concentric solenoid coils to wirelessly interrogate a sensor body comprised of a response material coupled to a magnetoelastic wire. The response material expands when it encounters a target, imposing mechanical stress on the wire and altering its magnetic permeability. The sensor bodies are passive, requiring no external power source, and they are small, measuring about 15 mm in length and 3.0 mm in diameter. Up to four sensor bodies can be configured as an evenly-spaced linear array. The sensor system operates by applying a low-frequency, current-stabilized, filtered triangle wave to a uniform-density excitation coil to switch the magnetic domains within the wire. Further, the responses from the sensors are picked up by a detection coil as stress-induced changes in the Faraday voltage, and the strong magnetic field induced by the excitation coil in the detection coil is nullified by a cancellation coil reverse-wound in series with the detection coil. The responses of the sensors in an array are separated in time by a linear gradient dc biasing coil. The sensors can be interrogated through metallic and nonmetallic barriers. The signals from the detection coil and the excitation coil are digitized by a pair of bipolar analog-to-digital converters (ADCs). A Raspberry Pi single-board computer (SBC) and associated software perform data acquisition and control all aspects of the sensor system hardware. The program allows the user to select the number of sensors in the array, the type of signal that is being collected, and the number of samples to take. The program also allows for signal processing of the sensor data, such as baseline correction. The program can differentiate sensor peaks from each other and calculate the magnitude of each sensor response with less than 1% error. The data are then displayed along with a graph of the signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Silver Lining

Clouds are shareable scientific instruments that create the potential for reproducibility by ensuring that all investigators have access to a common execution platform on which computational experiments can be repeated and compared. By virtue of the interface they present, they also lead to the creation of digital artifacts compatible with the cloud, such as images or orchestration templates, that go a long way-and sometimes all the way-to representing an experiment in a digital, repeatable form. In this article, I describe how we developed these natural advantages of clouds in the Chameleon testbed and argue that we should leverage them to create a digital research marketplace that would make repeating experiments as natural and viable part of research as sharing ideas via reading papers is today.

Cloud computing↗

The Open Science Cyber Risk Profile: The Rosetta Stone for Open Science and Cybersecurity

The Open Science Cyber Risk Profile (OSCRP) working group has created a document that motivates scientists by demonstrating how improving their security posture reduces the risks to their science. This effort aims to both bridge the communication gap between scientists and IT security professionals and allows for the effective management of risks to open science caused by IT security threats.

97 MATHEMATICS AND COMPUTING↗

Performance Testing and Assessment of Protection Scheme Using Real-Time Hardware-in-the-Loop and IEC 61850 Standard

The main challenge of the microgrid is to design a suitable protection scheme due to the complexity of the architecture of the microgrid. The importance of the proposed protection technique is threefold. First, it presents a co-simulation platform to integrate between a simulated model on power system computer aided design (PSCAD)/real time digital simulator computer aided design (RSCAD) software’s and physical devices schweitzer engineering laboratories (SEL) 421-7 relays to protect the microgrid that includes different resources connected based on inverter interface. Second, it presents a comprehensive hardware/software setup to test the protective relays in a closed loop system and shows how to configure the protective relay’s International Electrotechnical Commission 61850 communications. Third, IEEE 1588 standard is used to provide sub nanoseconds latency between the simulated model that emulated on real time digital simulator (RTDS) and the external devices. Also, the measurement signals are synchronized between RTDS and the external devices using giga-transceiver synchronization card (GTSYNC) interface card and SEL-2488 satellite-synchronized network clock. The results showed that the co-simulation infrastructure introduces a highly dependable design, analysis, and testing environment for cyber and physical data flow in the system. Besides that, the voltages at ac/dc sides and frequency at fault condition were maintained due to the energy storage device contributions at different modes of operation.

42 ENGINEERING↗

Pulse Pileup Analysis for a Double-Sided Silicon Strip Detector Using Variable Pulse Shapes

On account of pulse pileup, photon counting detectors (PCDs) suffer from count loss and energy distortion when operating in high count rate environments. Here, we researched the pulse pileup of a double-sided silicon strip detector (DSSSD) to evaluate its potential application in a mammography system. We analyzed the pulse pileup using pulses of varied shapes, where the shape of the pulse depends on the location of photon interaction within the detector. To obtain the shaped pulses, first, transient currents for photons interacting at different locations were simulated using a Technology Computer-Aided Design (TCAD) software. Next, the currents were shaped by a CR- RC 2 shaping circuit, calculated using Simulink. After obtaining these pulses, both the different orders of pileup and the energy spectrum were calculated by taking into account the following two factors: 1) spatial distribution of photon interactions within the detector and 2) time interval distribution between successive photons under a given photon flux. We found that for a DSSSD with a thickness of 300 μm, a pitch of 25 μm, and a strip length of 1 cm, under a bias voltage of 50 V, the variable pulse shape model predicts that the fraction free of pileup can be >90% under a photon flux of 3.75 Mcps/mm 2 (million counts per second per square mm). The DSSSD is a promising candidate for digital mammography applications.

47 OTHER INSTRUMENTATION↗

Utilization of Hydroturbines in Wastewater Treatment Plants

Wastewater treatment plants (WWTPs) are a significant energy consumer, yet there are several opportunities for implementing on-site power generation systems. Within the treatment process, the high flow rate of effluent is produced and discharged to a nearby water body by gravity. Thus, hydroturbines can be utilized to generate power in such an application due to a difference in elevation and high flow rate. This paper presents a case study of introducing a hydroturbine in a WWTP in Wisconsin and evaluating the power output in addition to determining the energy savings. The WWTP considered in this study has an effluent flow rate of 190 MGD (million gallons per day) and elevation difference of 3 m (10 ft) between the final stage of treatment and the discharge point. Based on the parameters above; hubless rim-drive Kaplan type hydroturbine (RDT) is the optimal choice to be used in such an application. The RDT is designed and optimized by using in-house code. A computational fluid dynamics (CFD) software is applied to evaluate the performance of the proposed model, and the system is simulated through homer software to validate the results generated by the CFD. The expected savings is estimated to be 1564 MWh/yr.

Energy & Fuels↗

Determination of the optimal tolerance for MLC positioning in sliding window and VMAT techniques

Purpose: Several authors have recommended a 2 mm tolerance for multileaf collimator (MLC) positioning in sliding window treatments. In volumetric modulated arc therapy (VMAT) treatments, however, the optimal tolerance for MLC positioning remains unknown. In this paper, the authors present the results of a multicenter study to determine the optimal tolerance for both techniques. Methods: The procedure used is based on dynalog file analysis. The study was carried out using seven Varian linear accelerators from five different centers. Dynalogs were collected from over 100 000 clinical treatments and in-house software was used to compute the number of tolerance faults as a function of the user-defined tolerance. Thus, the optimal value for this tolerance, defined as the lowest achievable value, was investigated. Results: Dynalog files accurately predict the number of tolerance faults as a function of the tolerance value, especially for low fault incidences. All MLCs behaved similarly and the Millennium120 and the HD120 models yielded comparable results. In sliding window techniques, the number of beams with an incidence of hold-offs >1% rapidly decreases for a tolerance of 1.5 mm. In VMAT techniques, the number of tolerance faults sharply drops for tolerances around 2 mm. For a tolerance of 2.5 mm, less than 0.1% of the VMAT arcs presented tolerance faults. Conclusions: Dynalog analysis provides a feasible method for investigating the optimal tolerance for MLC positioning in dynamic fields. In sliding window treatments, the tolerance of 2 mm was found to be adequate, although it can be reduced to 1.5 mm. In VMAT treatments, the typically used 5 mm tolerance is excessively high. Instead, a tolerance of 2.5 mm is recommended.

07 ISOTOPE AND RADIATION SOURCES↗

MO-FG-BRA-07: Intrafractional Motion Effect Can Be Minimized in Tomotherapy Stereotactic Body Radiotherapy (SBRT)

Purpose: Tomotherapy has unique challenges in handling intrafractional motion compared to conventional LINAC. In this study, we analyzed the impact of intrafractional motion on cumulative dosimetry using actual patient motion data and investigated real time jaw/MLC compensation approaches to minimize the motion-induced dose discrepancy in Tomotherapy SBRT treatment. Methods: Intrafractional motion data recorded in two CyberKnife lung treatment cases through fiducial tracking and two LINAC prostate cases through Calypso tracking were used in this study. For each treatment site, one representative case has an average motion (6mm) and one has a large motion (10mm for lung and 15mm for prostate). The cases were re-planned on Tomotherapy for SBRT. Each case was planned with 3 different jaw settings: 1cm static, 2.5cm dynamic, and 5cm dynamic. 4D dose accumulation software was developed to compute dose with the recorded motions and theoretically compensate motions by modifying original jaw and MLC to track the trajectory of the tumor. Results: PTV coverage in Tomotherapy SBRT for patients with intrafractional motion depends on motion type, amplitude and plan settings. For the prostate patient with large motion, PTV coverage changed from 97.2% (motion-free) to 47.1% (target motion-included), 96.6% to 58.5% and 96.3% to 97.8% for the 1cm static jaw, 2.5cm dynamic jaw and 5cm dynamic jaw setting, respectively. For the lung patient with large motion, PTV coverage discrepancies showed a similar trend of change. When the jaw and MLC compensation program was engaged, the motion compromised PTV coverage was recovered back to >95% for all cases and plans. All organs at risk (OAR) were spared with < 5% increase from original motion-free plans. Conclusion: Tomotherapy SBRT is less motion-impacted when 5cm dynamic jaw is used. Once the motion pattern is known, the jaw and MLC compensation program can largely minimize the compromised target coverage and OAR sparing.

60 APPLIED LIFE SCIENCES↗

A Simple, Scalable Large Deformation Solid Mechanics Implementation in the MOOSE Framework

This article describes a large deformation solid mechanics solver implemented as part of the freely available and open source MOOSE finite element simulation framework. The article documents the choices made in developing the solid mechanics framework and describes novel formulations for the gradient operator and constitutive modeling framework made to simplify implementations of different coordinate systems, stabilized gradient operators, and different constitutive model inputs and outputs. In the process, the article describes a new formulation that casts objective integration of the Cauchy stress as a linear transformation of the small stress rate. Finally, the article presents key implementation details and examines the parallel efficiency of the solid mechanics solver implemented in MOOSE. The implementation retains a good weak scaling efficiency beyond 1,000 parallel processes. The article includes a discussion of the factors limiting the parallel efficiency of implicit, large deformation solid mechanics codes on current high-performance computers, with the main current limitation being the scalability of the algebraic multigrid methods used to solve the linearized equilibrium equations.

Applied computing → Computer-aided design↗

Towards Seamless Interoperability of MPI-OpenMP Applications

A chasm exists between mathematical software libraries written for MPI-based applications and those written for OpenMP applications. Recently, however, PETSc enables the simple use of its MPI-based linear solvers from OpenMP applications. Separately, the MPICH MPI development team has started a new project to allow almost seamless MPI use in OpenMP applications. Both proposed approaches would result in a similar user experience. Here, we discuss the reasons for these projects and their potential for providing more numerical library choices for OpenMP applications, including the unlimited assortment of linear solvers available in PETSc. In addition, we present the performance of an application using the first approach, demonstrating its efficacy.

MPI↗