Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerated aging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Assessment of AFM - KPFM and SSRM for Measuring and Characterizing Materials Aging Processes

Atomic Force Microscopy (AFM), in conjunction with Peak Force Kelvin Probe Force Microscopy (PF-KPFM) and Peak Force Scanning Spreading Resistance Microscopy (PF-SSRM), was used to assess changes on thin metal films that underwent accelerated aging. The AFM technique provides a relatively easy, non-destructive methodology that does not require high-vacuum facilities to obtain nanometer-scale spatial resolution of surface chemistry changes. Surface morphology, roughness, contact potential difference, and spreading resistance were monitored to qualitatively identify effects of aging-morphology changes and oxidation of Au, Al, Cu thin film standards as well as diffusion of CuAu and AlAu thin film stacks at 65C under dried nitrogen flow conditions. AFM PF-KPFM and PF-SSRM modes have been exercised, refined and have proven to be viable and necessary early aging detection tools.

36 MATERIALS SCIENCE↗

Exploring Electrode-Level State-of-Charge and State-of-Health Dynamics in Lithium-Ion Battery Cells: Modeling and Experimental Identification

A computationally efficient model serves as a critical prerequisite for battery performance analysis and advanced battery management algorithm design. Although battery models that capture cell-level behavior have been widely explored in existing literature, electrode-level battery models have received much lesser attention till to date. However, such electrode-level models can significantly increase battery performance and life by enabling electrode-level health-conscious control. Such electrode-level control can effectively expand usable energy and power limits of the battery cells by utilizing the knowledge of individual electrodes' charge and health. In this context, this paper presents a comprehensive battery model developed with a reference electrode insertion that captures (i) electrode-level charge/discharge dynamics, (ii) stoichiometric and temporal dependencies of electrode-level resistances, (iii) solid electrolyte interface (SEI) layer growth as key degradation phenomenon, and (iv) capacity fade and resistance rise in each electrode due to nominal battery aging. The proposed model is identified, and a preliminary validation is performed utilizing terminal voltage and negative electrode potential data collected from a pouch cell under one continuous cycling and accelerated aging conditions where the cell experienced 14% capacity loss.

aging↗

Water Contamination Impacts on Biodiesel Antioxidants and Storage Stability

Biodiesel (fatty acid methyl esters) can oxidize in storage to form acids and gums that negatively impact engine performance and durability. Antioxidant additives are used to increase biodiesel storage stability, and previous studies that evaluated the effectiveness of antioxidants demonstrated that more polar antioxidants tend to be the most effective (provide the largest improvement in stability per unit of antioxidant added). However, polar antioxidants have significant water solubility, and diesel fuel storage tanks are commonly contaminated with water (forming a layer of water under the fuel). This study investigates whether nonpolar antioxidants, which are less effective in dry environments, might be more effective under wet conditions simulating real-world storage. Biodiesel blends treated with polar and nonpolar antioxidants were subjected to accelerated aging using the ASTM D4625 protocol (storage at 43 °C, open to air, for up to 24 weeks) both with and without added water. Fuels treated with polar/higher-effectiveness compounds and stored in contact with water (simulating water in a storage tank) or high humidity showed accelerated loss of stability compared to dry storage. The same fuel treated with a nonpolar antioxidant and stored in the same conditions did not exhibit accelerated stability loss and thus had higher storage stability over the long term despite treatment with an initially less effective additive. Analysis of the fuels during aging showed that this loss of stability was not due to oxidation but rather extraction of the polar antioxidant into the water layer. Antioxidant additives that are incompatible with wet or humid storage conditions were found to cause faster-than-anticipated loss of stability, which was preventable with use of nonpolar additives.

09 BIOMASS FUELS↗

A Modified Network Alteration Model to Predict Quasi-Static Behavior of the Cross-Linked Polymers During Hydrolytic Aging

Abstract The network alteration theory is utilized to capture the effects of hydrolytic aging on the mechanical integrity of the polymer matrix. Hydrolytic degradation generally considered as a result of two simultaneous chemical phenomena; (i) reduction of the cross-links, and (ii) active chain loss. Assuming the alteration of the chain density is identical to the change of the number average molecular weight along the aging trajectory, the strain energy of polymer matrix can be rewritten as a function of deformation, deformation history, storage time, and aging temperature. The proposed model includes only five physically inspired material parameters. Thus, while it is computationally efficient, it shows good agreement with own experimental data, which performed on various range of accelerated aging temperatures and times. With respect to its computational efficiency, simplicity, accuracy, and interpret-ability, the model is a good choice for advanced implementations in FE programs.

Bahrololoumi, Amir↗

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed↗

Storage Stability of 50% Biodiesel Blends and Neat Biodiesel Produced in North America

This study investigated aging of two petroleum diesel, seven B100, three B20 blends, and 14 B50 blends representing the full range of fuels in the North American market for 12-weeks at 43 degrees Celsius under the ASTM D4625 accelerated aging protocol. Twelve-weeks under D4625 aging represents approximately 12 months of storage time in clean, dry conditions. Samples were taken every two weeks for measurement of Rancimat induction period (IP), peroxide content, and TAN; and total insoluble were measured at the end of the 12-week test.

09 BIOMASS FUELS↗

Quantifying the effects of artificial aging on the ignition and self-propagating reactions of Ni(V)/Al multilayers

Bimetallic, reactive multilayers are uniformly structured materials composed of alternating nanoscale layers that may be ignited to produce self-propagating intermetallic-formation reactions. When reactive multilayers age, there is a change in local composition and loss of stored chemical energy due to mass transport and rearrangement at the interfaces. Here, to quantify the long-term reliability of commercial Ni(V)/Al multilayers, the effects of accelerated aging on both ignition sensitivity and self-propagating reactions have been examined. Thermally aged samples were characterized using transmission electron microscopy, differential scanning calorimetry, and laser ignition combined with high-speed videography. The analytically quantifiable nature of both continuous wave laser ignition and reactive wave propagation enabled calculations of Arrhenius rate constants for as-received and various heat-treated multilayers. With heat treatment, there is a change in the intermixed thickness and interfacial chemistry that decreases the activation energy for point ignition but increases it for self-propagating reactions. This finding implies that with increased thermal aging, the reaction becomes easier to facilitate in the solid state but harder in the liquid phase.

Energetic material↗

Degradation and Modeling of Large-Format Commercial Lithium-Ion Cells as a Function of Chemistry, Design, and Aging Conditions

Demand for large-format (>10 Ah) lithium-ion batteries has increased substantially in recent years, due to the growth of both electric vehicle and stationary energy storage markets. The economics of these applications is sensitive to the lifetime of the batteries, and end-of-life can either be due to energy or power limitations. Despite this, there is little information from cell manufacturers on the sensitivity of cell degradation to environmental conditions or battery use. This work reports accelerated aging test data from four commercial large-format lithium-ion batteries from three manufacturers, with varying design (thickness, casings, ...), chemistry (lithium-iron-phosphate (LFP) or lithium-nickel-manganese-cobalt-oxide positive electrodes (NMC), with graphite (Gr) negative electrodes), and capacity (50 to 250 Amp hours). The tested LFP|Gr cell is found to be relatively insensitive to cycling conditions like temperature or voltage window, while NMC|Gr cells have varying sensitivity. Degradation trends are further investigated by training predictive models: simple polynomial trend lines, a semi-empirical reduced-order model, and an empirical reduced-order model identified using machine-learning based on symbolic regression. Calendar and cycle life are simulated over a variety of conditions to directly compare the various batteries. Cell size and thickness are found to substantially impact sensitivity to temperature during cycle aging, while electrode chemistry impacts depth-of-discharge sensitivity. Real-world battery lifetime is evaluated by simulating residential energy storage and commercial frequency containment reserve systems in several U.S. climate regions. Predicted lifetime across cell types varies from 7 years to 20+ years, though all cells are predicted to have at least 10 year life in certain conditions.

battery lifetime↗

Lifelong cytomegalovirus and early‐LIFE irradiation synergistically potentiate age‐related defects in response to vaccination and infection

Abstract While whole‐body irradiation (WBI) can induce some hallmarks of immune aging, (re)activation of persistent microbial infection also occurs following WBI and may contribute to immune effects of WBI over the lifespan. To test this hypothesis in a model relevant to human immune aging, we examined separate and joint effects of lifelong latent murine cytomegalovirus (MCMV) and of early‐life WBI over the course of the lifespan. In late life, we then measured the response to a West Nile virus (WNV) live attenuated vaccine, and lethal WNV challenge subsequent to vaccination. We recently published that a single dose of non‐lethal WBI in youth, on its own, was not sufficient to accelerate aging of the murine immune system, despite widespread DNA damage and repopulation stress in hematopoietic cells. However, 4Gy sub‐lethal WBI caused manifest reactivation of MCMV. Following vaccination and challenge with WNV in the old age, MCMV‐infected animals experiencing 4Gy, but not lower, dose of sub‐lethal WBI in youth had reduced survival. By contrast, old irradiated mice lacking MCMV and MCMV‐infected, but not irradiated, mice were both protected to the same high level as the old non‐irradiated, uninfected controls. Analysis of the quality and quantity of anti‐WNV immunity showed that higher mortality in MCMV‐positive WBI mice correlated with increased levels of MCMV‐specific immune activation during WNV challenge. Moreover, we demonstrate that infection, including that by WNV, led to MCMV reactivation. Our data suggest that MCMV reactivation may be an important determinant of increased late‐life mortality following early‐life irradiation and late‐life acute infection.

59 BASIC BIOLOGICAL SCIENCES↗

A Physically-Based Model for Thermo-Oxidative and Hydrolytic Aging of Elastomers

A computationally efficient model is proposed to capture the loss of mechanical performance due to chemical aging that are formed as the competition of chain scission and cross-link formation/dissolution, such as thermo-oxidative aging or hydrolytic aging. The model should be considered an extension of our recent models [1, 2, 3] which further simplifies the matrix behavior based on the assumption of independence of environmental and mechanical damage. The model uses this assumption to reduce the necessary material parameters needed to model constitutive and inelastic behavior of elastomers during aging. To this end, the model can provide accurate predictions of the material performance with the significantly fewer number of fitting parameters. The model is relevant for all decay mechanisms formed by the occurrence of two simultaneous micro-mechanisms; (i) formation/reduction of the cross-links, and (ii) chain scission, both of which are present in thermo-oxidation and hydrolytic aging. Assuming the alteration of the chain density along the aging trajectory is identical to the peroxide cross-link density for thermo-oxidation, and the change of the average molecular weight for hydrolysis, the strain energy of polymer matrix can be rewritten as a function of deformation, deformation history, storage time and aging temperature. Next, the modified network alteration model is formulated for implementation into Finite Element (FE) simulations. The model is built on the presumption of homogeneous and consistent oxygen/water absorption and thus is mainly relevant for relatively thin samples exposed to environmental loads for a long time. The proposed model includes only six physically inspired material parameters. Therefore, while it is computationally efficient, it shows good agreement with own experimental data, which performed on various range of accelerated aging temperatures and times. With respect to its computational efficiency, simplicity, accuracy, and interpret-ability, the model is the right choice for advanced implementations in FE programs.

42 ENGINEERING↗

Helium bubble formation in aged plutonium metal at ambient conditions

A model of helium bubble formation is developed that assumes the initial nascent bubbles are generated when two diffusing helium atoms come within a distance of about the interatomic spacing of the plutonium atoms. These nascent bubbles are assumed to be locked in place and grow as additional helium atoms diffuse across their surfaces. Calculations of the helium-bubble number density and sizes as a function of age are compared to experiment. This leads to an inferred helium diffusion coefficient of-the-order of 10 -20 m 2 /s, supports the idea that most of the helium from alpha-decay end up in bubbles, and that previous transmission electron microscopy size estimates are biased low. The energy that helium can transfer to 40-year-old plutonium, upon expansion, is determined to be <0.1 Joules per gram of metal. The model predicts differences between the bubble properties in naturally and accelerated aged plutonium.

36 MATERIALS SCIENCE↗

Collaborative Approach to Identify Degradation Mechanisms and Validate Aging Protocols for a Diverse Set of DAC Materials (TCF Base Technology-Specific Final Report)

This work supports the mission of the U.S. Department of Energy to promote American energy leadership, technological innovation, and economic growth through the development of technologies for cost effective carbon capture. While capture technologies can provide carbon dioxide for enhanced oil recovery, many capture materials suffer from oxidative, hydrolytic and/or thermal degradation which leads to capacity loss and unwanted emissions such as ammonia. Short lifetimes increase operational costs and cost studies suffer from uncertainty because the true lifetimes of many capture materials are unknown. In this study, a suite of capture materials were studied to quantify their degradation, provide insight into the mechanisms that lead to their uptake loss and provide validated accelerated aging protocols for industry.

36 MATERIALS SCIENCE↗

Survey of Aging and Monitoring Concerns for Cables and Splices Due to Cable Repair and Replacement

The purpose of this report is to survey aging and monitoring concerns for electrical cable splices in nuclear power plants (NPPs) in long term operation. As portions of existing electrical cable runs in nuclear are replaced over time due to localized events, the total number of splices in NPPs is expected to increase. Relative to cables, the body of knowledge regarding aging of splices and splices in combination with aging cables in nuclear service environments in long-term operations is low. A few reports have considered the aging of cable system components other than cables (Jacobus 1990; Nelson 1998; Villaran and Lofaro 2002), but the nuclear industry has two decades of operating experience since these were published to further enlighten this issue. Herein we discuss electrical cables and splices commonly found in U.S. nuclear power plants, their qualification in safety-related application, and methods for monitoring their health condition. Common environmental stresses that can give rise to cable and splice failure are discussed. The Nuclear Regulatory Commission (NRC) Licensee Event Reports (LER) database was used to identify documented issues of cable and splice failure. The trend in the resultant data over time is considered to see if failures are increasing as plants age. Observations and conclusions of this work include: 1. Cables and splices are highly reliable components. Occurrence rates for events of interest were low and nearly constant over the last 20 years. 2. Common-cause failure for evaluated cable events of interest was observed to primarily be associated with loose connections, which may manifest associated with workmanship issues, thermal cycling, and/or vibration. 3. Replacement of cables is more common than repair, leading to an increase in proportion of new generation cables in the plant over time. 4. Splices on degraded cables have been observed to be problematic. Due to aging NPP infrastructure, including electrical cables, it is expected that such issues will continue to increase. 5. Condition monitoring approaches, while shown to be fruitful for cables, have been shown to be insensitive to degradation of splice sleeves, which are critical to the continued performance of splices. Additional condition monitoring (CM) work is needed to evaluate methods which are sensitive to the degradation of splice components. 6. Extended Material Degradation Assessment (EMDA) knowledge gaps for electrical cables (Bernstein et al. 2014) have not been investigated for splices but may represent similar concerns such as for the accelerated aging process historically used in environmental qualification.

42 ENGINEERING↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2020 Status Report)

Leak testing experiments to monitor the aging performance of Viton GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. In addition, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 °F for 12 to 14 years or aging at 270 °F for 8.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 10 to 10.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O Ring Fixture LongTerm Leak Performance (FY2021 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 19 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 9.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 11.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 26 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗