Search NASA⌕ Search

SEARCH · Search NASA

Results for “High-throughput sample processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Open Specy 1.0: Automated (Hyper)spectroscopy for Microplastics

Microplastic spectral analysis is one of the most time-consuming processes in studying microplastic pollution, often requiring days per sample. Researchers are transitioning to automated batch and hyperspectral image analysis techniques to enhance efficiency. Open Specy, initially aimed at manual single-spectrum analysis, has now integrated automated methods. This updated version, Open Specy 1.0, introduces several new features, including two algorithms for automated processing (smoothing and particle compression), an extensive library containing over 40,000 open-source Raman and FTIR spectra, and two machine learning classifiers (logistic regression and k medoids) developed from this library. Furthermore, it includes a revamped user interface, an R package, and a benchmark data set for testing future advancements in automated techniques. Researchers evaluated various configurations for hyperspectral smoothing, particle identification, compression, and splitting, to achieve combined recovery rates between 50 and 150% particle counts, identities, and sizes with a coefficient of variation (CV) of less than 40% (the accredited standard). Mean absorbance times the standard deviation provided a consistent particle identification. Hyperspectral smoothing led to a 96% combined recovery rate and reduced variability (CV = 38%) compared to the 86% recovery (CV = 83%) of nonsmoothed controls. Additionally, compressing spectra for particles was significantly faster (>3x) and showed similar accuracy but with reduced variability than processing each pixel individually. Key challenges persist in automating spectral analysis, particularly in refining particle splitting algorithms, and improving identification routines to minimize false positives and negatives. In conclusion, new methods in sample preparation for better stabilization and dispersion of particles could overcome some of these issues.

13 HYDRO ENERGY↗

Rapid Bayesian High Entropy Alloy Designs Fabricated via Wire Arc Additive Manufacturing

Purpose: This project seeks to demonstrate a new high-throughput (rapid) alloy design technique applied to creating new high entropy alloys (HEAs) for extreme environments. High entropy alloys shift the design paradigm from being focused on a single principal element (e.g. nickel-based alloys) to target alloys that include high atomic fractions (X >10%) of multiple elements. These HEA materials can exhibit sluggish diffusion and enhanced corrosion resistance, ideal for potential applications in advanced ultra supercritical (A-USC) steam cycles for power generation. Scope: The addition of multiple elements in high atomic fractions creates an enormous design space that cannot easily be investigated by traditional material design strategies such as designed of experiments (DOE). This project utilizes a Bayesian machine learning algorithm that has been modified to work with calculation of phase diagrams (CALPHAD) software. This Bayesian algorithm reduces manual inputs and increase the likelihood of achieving an optimal solution. Compositional inputs to this algorithm will be assessed using existing material property models for high temperature strength and corrosion resistance. The target for alloy performance will be a 15% (~100 ⁰C) increase in allowable service temperature beyond heat-resistant stainless steels while maintaining or improving alloy cost and corrosion resistance. Haynes 230 was selected as a baseline, which is 57 wt% Ni with 22 wt% Cr 14 wt% W, and 2 wt% Mo as solid solution strengtheners. In addition to rapid design via Bayesian machine learning, the alloys were rapidly fabricated using a multi-wire arc additive manufacturing (mWAAM) technique which allows for precise control of alloy composition and assessing of alloy design “windows” to study composition effects. Build speeds for wire-arc additive processes are among the highest for additive technologies enabling rapid and reliable sample fabrication when compared to conventional methods such as arc button melting. The mWAAM samples will be rapidly characterized via instrumented indentation for room temperature modulus and strength and for elevated temperature strength via hot hardness tests. After being screened with hardness testing, potential alloys will be further evaluated with conventional microscopy techniques including scanning electron microscopy (SEM) and transmission electron microscopy (TEM) to assess agreement with modeling results. The most promising compositions will also be evaluated by printing full sized tensile specimens for mechanical behavior tests at elevated temperatures. Results: Bayesian machine learning of a single performance function was initially used to optimize five performance metrics: 1) single phase stability, 2) yield strength, 3) creep resistance (low diffusion coefficient), 4) freezing range (weldability), and 5) material cost. The single performance function was suboptimal as assumptions had to be made about the results while formulating the optimization. A goal-oriented Bayesian optimization strategy (Hanaoka, 2021) was implemented with CALPHAD for use with the five metrics above. This multi-objective Bayesian optimization (MOBO) enabled the design of NiCrCoFe alloys with V and W additions. A base composition of NiCoCr was selected as Ni provides a stable FCC matrix, Cr aids corrosion/oxidation resistance, and Co is a solid-solutions strengthener that also improves creep by increasing the activation energy. Fe helps reduce diffusion coefficients and cost. Finally, V and W were selected for their reasonable solubility and high atomic misfit to aid in solid solution strengthening. Cracking of the mWAAM specimens was an early issue, and the Easton solidification cracking model (Easton et al., 2014a) was selected for addition to the MOBO function. High performing alloys fabricated by mWAAM included Ni 28 Cr 25 Co 26 Fe 15 V 8 and Ni 62 Cr 18 Co 1 Fe 3 W 15 . It was observed that even after adapting the mWAAM process for W, the W did not fully dissolve. To fully evaluate the Ni 62 Cr 18 Co 1 Fe 3 W 15 composition, a cored wire (80-20 NiCr sheath/powder core) was manufactured and printed via WAAM, and HIP’ing was utilized to homogenize and densify the printed alloy. The V and W alloys produced met metrics 1 (solid solution), 4 (solidification cracking), and 5 (cost). However, an unmodeled mechanism of thermal stress cracking was identified in the WAAM produced materials, perhaps exacerbated by the lack of grain boundary strengthening elements (B, C). Conclusions & Recommendations: A high-throughput (rapid) alloy design technique was applied to designing and manufacturing new high entropy alloys (HEAs) for extreme environments utilizing MOBO and mWAAM. The developed process was rapid and effective in addressing the mechanisms included in the model. The lack of grain boundary strengthening element additions (e.g., B, C) was a simplification that likely produced thermal stress cracking that turned into a large part of the investigation. Additions on the order of 0.005 wt% B and 0.05 wt% C likely would have minimized thermal stress grain boundary cracking. Overall, the high throughput design strategy is promising for rapid design of metrics-driven alloys for advanced ultra supercritical (A-USC) steam cycles for power generation. The MOBO and mWAAM process could be commercialized to accelerate metrics-driven alloy design. In addition, the cored-wire process utilized for scale-up is a promising high-volume process for WAAM alloy development and scale-up.

36 MATERIALS SCIENCE↗

Design, Processing, and Properties of WTaCrV-Hf Multi-principal Element Alloys

Refractory multi-principal element alloys are candidates for high-temperature structural components due, in part, to their high strength and high melting points. Single-phase materials are initially preferred for isotropic material properties as a function of time and temperature in service conditions. This work outlines a computational rank-ordering and experimental validation methodology for single-phase body-centered-cubic phase stability in WTaCrV-Hf alloys using order–disorder transition temperature. Eight compositions were fabricated by arc-melting and heat-treated at 1400 °C for 24 hrs. X-ray diffraction, energy-dispersive x-ray spectroscopy, and Vickers hardness testing showed alloys with order–disorder transition temperatures below 600 °C formed a single-phase body-centered-cubic structure during solidification and remained single-phase after heat-treatment. The sample possessing the lowest order–disorder transition temperature exhibited slip traces suggestive of room-temperature plastic deformation under Vickers indentation, with both heat-treated single-phase samples exhibiting hardnesses over 800 HV with little cracking compared to tungsten. These results establish order–disorder transition temperature as a viable predictive parameter for multi-principal element alloy phase stability. The methodology outlined in this work provides a framework for future design, fabrication, and characterization of high-temperature structural multi-principal element alloys.

CALPHAD↗

High-Throughput Microstructural Characterization and Process Correlation Using Automated Electron Backscatter Diffraction

The need to optimize the processing conditions of additively manufactured (AM) metals and alloys has driven advances in throughput capabilities for material property measurements such as tensile strength or hardness. High-throughput (HT) characterization of AM metal microstructure has fallen significantly behind the pace of property measurements due to intrinsic bottlenecks associated with the artisan and labor-intensive preparation methods required to produce highly polished surfaces. This inequality in data throughput has led to a reliance on heuristics to connect process to structure or structure to properties for AM structural materials. In this study, we show a transformative approach to achieve laser powder bed fusion (LPBF) printing, HT preparation using dry electropolishing and HT electron backscatter diffraction (EBSD). This approach was used to construct a library of > 600 experimental EBSD sample sets spanning a diverse range of LPBF process conditions for AM Kovar. This vast library is far more expansive in parameter space than most state-of-the-art studies, yet it required only approximately 10 labor hours to acquire. Build geometries, surface preparation methods, and microscopy details, as well as the entire library of >600 EBSD data sets over the two sample design versions, have been shared with intent for the materials community to leverage the data and further advance the approach. Using this library, we investigated process–structure relationships and uncovered an unexpected, strong dependence of microstructure on location within the build, when varied, using otherwise identical laser parameters.

Characterization and Analytical Technique↗

Machine learning with knowledge constraints for process optimization of open-air perovskite solar cell manufacturing

Perovskite photovoltaics (PV) have achieved rapid development in the past decade in terms of power conversion efficiency of small-area lab-scale devices; however, successful commercialization still requires further development of low-cost, scalable, and high-throughput manufacturing techniques. One of the critical challenges of developing a new fabrication technique is the high-dimensional parameter space for optimization, but machine learning (ML) can readily be used to accelerate perovskite PV scaling. Herein, we present an ML-guided framework of sequential learning for manufacturing process optimization. We apply our methodology to the Rapid Spray Plasma Processing (RSPP) technique for perovskite thin films in ambient conditions. With a limited experimental budget of screening 100 process conditions, we demonstrated an efficiency improvement to 18.5% as the best-in-our-lab device fabricated by RSPP, and we also experimentally found 10 unique process conditions to produce the top-performing devices of more than 17% efficiency, which is 5 times higher rate of success than the control experiments with pseudo-random Latin hypercube sampling. Our model is enabled by three innovations: (a) flexible knowledge transfer between experimental processes by incorporating data from prior experimental data as a probabilistic constraint; (b) incorporation of both subjective human observations and ML insights when selecting next experiments; (c) adaptive strategy of locating the region of interest using Bayesian optimization first, and then conducting local exploration for high-efficiency devices. Furthermore, in virtual benchmarking, our framework achieves faster improvements with limited experimental budgets than traditional design-of-experiments methods (e.g., one-variable-at-a-time sampling). This framework shows the capability of incorporating researchers’ domain knowledge into the ML-guided optimization loop; therefore, it has the potential to facilitate the wider adoption of ML in scaling to perovskite PV manufacturing.

14 SOLAR ENERGY↗

A dual dynamic shutter system for accelerating ion irradiation sample throughput via lateral gas implantation gradients

Ion irradiation for material performance testing is limited due to its serial nature, which allows for only one value of the implantation (appm) versus dose (dpa) parameter space to be explored for each ion and experiment at a time. While ion irradiation can accelerate the process by up to three orders of magnitude compared to neutron irradiation experiments, the sample throughput for ion irradiation remains relatively low. To address these limitations, a novel capability has been developed at the Michigan Ion Beam Laboratory (MIBL), enabling for the creation of single- and two-dimensional lateral ion implantation gradients using recently installed motorized-controlled ion-beam shutters. This advancement can generate a wide scope of the two-dimensional (H+, He2+) implantation parameter space within a single sample. Integration of this new capability now allows for dual- and triple-ion beam experiments to be performed with full user control over not only the ion implantation depth, but also laterally across the sample by imposing ion implantation concentration gradients, thus providing researchers with a high-throughput means for material testing under various irradiation conditions. Furthermore, recent improvements in MIBL's microbeam ion-beam analysis (IBA) target station now allow for probing these concentration gradients in irradiated alloys with exceptional spatial resolution, down to 10 µm. These two approaches promise to significantly improve ion irradiation capabilities and increase the sample throughput by several orders of magnitude. The application of the shutter technique plus the subsequent microbeam characterization of the imposed implantation gradients are showcased by two proof-of-principle ion-irradiated experiments, one performed on single-crystal Si and the other on the fusion-candidate alloy F82H-IEA. These advancements mark a substantial leap in ion-beam technology, offering researchers a robust, high-throughput method to efficiently investigate candidate alloys with high technological readiness for both advanced fission and fusion reactor applications, in a time- and cost-effective manner.

36 - MATERIALS SCIENCE↗

A Six-Membered Concerted Mechanism for CO 2 Capture by Amines Studied under Charged Microdroplet Reaction Conditions

Carbon dioxide (CO 2 ) capture and storage represents an important technological challenge. A mechanistic understanding of interactions involved in the capture process is necessary not only for technological development but also for efficient conversion of captured CO 2 into value-added materials. Herein, we present a novel contained secondary electrospray ionization platform for studying the interactions of gaseous amines and CO 2 gas under microdroplet reaction conditions, which enables mass spectrometry (MS) characterization of CO 2 capture products and intermediates in real time. We detected [2 M + CO 2 + H] + species, which corresponds to a six-membered intermediate. DFT calculations confirmed the high stability of the protonated six-membered ring intermediate. This finding provides a plausible concerted mechanism in the microdroplet environment that excludes the involvement of thermodynamically disfavored ionic species. The carbamic acid counterpart of the final product/salt was readily characterized by tandem MS. The carbamic acid/amine salt was also isolated and characterized by Fourier transform infrared spectroscopy. By virtue of the fact that headspace vapors of amines are sampled, we were able to establish a high-throughput platform that enabled the CO 2 capture capacity of five different amines to be studied in under 2 min. The same device also enabled the absolute quantification of capture capacity.

Amines↗

Uncertainty-Aware Machine Learning for Small-Angle X-ray Scattering Analysis in Autonomous Experimentation

Small-angle X-ray scattering (SAXS) is a powerful high-throughput characterization tool for probing nanoscale structure in native sample environments, providing real-time morphological information such as nanoparticle size and shape during synthesis. However, automated SAXS data analysis for extracting meaningful structural parameters is non-trivial and remains a bottleneck in closed-loop experimentation towards autonomous materials discovery, which demands fast, reliable, and uncertainty-aware data analysis. Here, we develop a machine-learning approach for automated SAXS analysis tailored to closed-loop nanoparticle synthesis. A Random Forest (RF) regression model is trained on 100,000 synthetic SAXS curves generated from polydisperse spherical nanoparticles with realistic background contributions. Using normalized one-dimensional SAXS intensity profiles as input, the RF model directly predicts nanoparticle radius, size polydispersity, and background parameters, while the ensemble standard deviation across trees provides built-in uncertainty quantification (UQ). On synthetic data, we show that combining fit-quality metrics (R 2 , MAE) with thresholds on prediction uncertainty reliably identifies accurate parameter estimates without access to ground truth. We then apply the trained model to 365 experimental SAXS profiles of citrate-reduced gold nanoparticles synthesized using an automated droplet-flow microreactor with in situ SAXS at a synchrotron beamline, classifying the results into high- and low-confidence subsets based on UQ metrics. Finally, we integrate RF-based SAXS analysis into a simulated closed-loop optimization campaign using Gaussian process Bayesian optimization to minimize nanoparticle polydispersity, benchmarking against conventional automated Levenberg–Marquardt fitting. The RF-guided campaign exhibits substantially faster convergence and lower relative opportunity cost (∼0.07 vs ∼0.3), demonstrating that uncertainty-aware machine-learning SAXS analysis significantly enhances the efficiency and robustness of autonomous nanomaterials synthesis workflows.

Bayesian optimization↗

High-throughput and high-efficiency sample preparation for single-cell proteomics using a nested nanowell chip

Abstract Global quantification of protein abundances in single cells could provide direct information on cellular phenotypes and complement transcriptomics measurements. However, single-cell proteomics is still immature and confronts many technical challenges. Herein we describe a nested nanoPOTS (N2) chip to improve protein recovery, operation robustness, and processing throughput for isobaric-labeling-based scProteomics workflow. The N2 chip reduces reaction volume to <30 nL and increases capacity to >240 single cells on a single microchip. The tandem mass tag (TMT) pooling step is simplified by adding a microliter droplet on the nested nanowells to combine labeled single-cell samples. In the analysis of ~100 individual cells from three different cell lines, we demonstrate that the N2 chip-based scProteomics platform can robustly quantify ~1500 proteins and reveal membrane protein markers. Our analyses also reveal low protein abundance variations, suggesting the single-cell proteome profiles are highly stable for the cells cultured under identical conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Inverse design of photonic surfaces via multi fidelity ensemble framework and femtosecond laser processing

We demonstrate a multi-fidelity (MF) machine learning ensemble framework for the inverse design of photonic surfaces, trained on a dataset of 11,759 samples that we fabricate using high throughput femtosecond laser processing. The MF ensemble combines an initial low fidelity model for generating design solutions, with a high fidelity model that refines these solutions through local optimization. The combined MF ensemble can generate multiple disparate sets of laser-processing parameters that can each produce the same target input spectral emissivity with high accuracy (root mean squared errors < 2%). SHapley Additive exPlanations analysis shows transparent model interpretability of the complex relationship between laser parameters and spectral emissivity. Finally, the MF ensemble is experimentally validated by fabricating and evaluating photonic surface designs that it generates for improved efficiency energy harvesting devices. Our approach provides a powerful tool for advancing the inverse design of photonic surfaces in energy harvesting applications.

97 MATHEMATICS AND COMPUTING↗

The evolution of analytical techniques for multiplex analysis of protein biomarkers

Introduction: The landscape of biomarker development has evolved with advanced analytical technologies, particularly affinity- and mass spectrometry-based techniques. These advancements have deepened our understanding of disease mechanisms, enabling the development of precise diagnostic tools and personalized medicine. Protein biomarkers, which play pivotal roles in biological processes, have become invaluable in diagnosing and monitoring diseases, aided by their presence in various biological samples and the availability of established detection methods. Areas covered: This review covers the role of protein biomarkers in clinical practice, the development and dimensionality of protein biomarkers, advancements in detection technologies, a comparison of these technologies, and future directions in biomarker discovery and disease mechanism elucidation. Expert opinion: Advances in biomarker technologies have the potential to transform diagnostics and personalized treatment but face challenges such as high costs and technical complexity. Enhancing reproducibility and integrating multi-omics approaches may offer better insights. In conclusion, the field should evolve toward high-throughput, automated methods, continuously adapting research, and clinical practices.

59 BASIC BIOLOGICAL SCIENCES↗

Genomic reconstruction of Bacillus anthracis from complex environmental samples enables high-throughput identification and lineage assignment in Pakistan

Bacillus anthracis, the causative agent of anthrax, is a highly virulent zoonotic pathogen primarily affecting domesticated and wild herbivores. Human exposure to B. anthracis is primarily through contact with infected animals or contaminated animal products. In Pakistan, where livestock vaccines are largely unavailable and infected carcasses are often disposed of improperly, the risk to humans, wildlife and livestock is significant. Currently, the diagnosis of anthrax infections and outbreak tracing necessitates the isolation and culturing of B. anthracis, a process that requires BSL-3 facilities. In this study, we show that positive identification, genome reconstruction and lineage assignment can be accomplished using bioinformatic analysis of DNA extracted directly from environmental samples that would otherwise provide the starting material for isolation and culturing. This approach does not require laboratory target enrichment as is necessary for other pathogens, due in part to the extremely high bacterial load in the bloodstream in the deceased animals. Using these methods, we greatly expand the knowledge of endemic B. anthracis in Pakistan. We provide the first reference B. anthracis genomes from Pakistan since the 1970s and identify A.Br.014 Aust94 as a minor circulating sublineage alongside the dominant A.Br.047 Vollum. Future work will focus on the limits of detection and will determine if this bioinformatic method can be expanded more broadly for B. anthracis or other pathogens to replace typical culture-based methods.

A.Br.047 Vollum↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

NACHOS, a CubeSat-based high-resolution UV-Visible hyperspectral imager for remote sensing of trace gases: system overview and science objectives

Here, the Nano-satellite Atmospheric Chemistry Hyperspectral Observation System (NACHOS) is a high-throughput (f/2.9), high spectral resolution (~1.3 nm optical resolution, 0.6 nm sampling) Offner-design hyperspectral imager operating in the 300-500 nm spectral region. The 1.5U instrument payload (1U optical system, 0.5U electronics module) is hosted by a 1.5U LANL-designed CubeSat bus to comprise a 3U complete satellite. Spectroscopically similar to NASA’s Ozone Monitoring Instrument (OMI), which provides wide-field global mapping of ozone and other gases at coarse spatial resolution, NACHOS fills the complementary niche of targeted measurements at much higher spatial resolution. With 350 across-track spatial pixels and a 15-degree across-track field of view, NACHOS will provide spectral imaging at roughly 0.4 km per pixel from 500 km altitude. NACHOS incorporates highly streamlined gas-retrieval algorithms for rapid onboard processing, alleviating the need to routinely downlink massive hyperspectral data cubes. We will discuss the instrument design, challenges in achieving mechanical robustness to launch vibration in such a compact instrument, the onboard calibration system, and gas-retrieval data downlink strategy. We will also discuss potential science missions, including monitoring of NO 2 as an easily detected proxy for anthropogenic fossil-fuel greenhouse gases, monitoring lowlevel SO 2 degassing at pre-eruptive volcanoes, H 2 CO from wildfires, and characterization of aerosols. The long-term vision is for a many-satellite constellation that could provide both high spatial resolution and frequent revisits for selected targets of interest. As an initial technology demonstration of this vision, the NACHOS project is currently slated to launch two CubeSats in early 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fine-scale evaluation of two standard 16S rRNA gene amplicon primer pairs for analysis of total prokaryotes and archaeal nitrifiers in differently managed soils

The advance of high-throughput molecular biology tools allows in-depth profiling of microbial communities in soils, which possess a high diversity of prokaryotic microorganisms. Amplicon-based sequencing of 16S rRNA genes is the most common approach to studying the richness and composition of soil prokaryotes. To reliably detect different taxonomic lineages of microorganisms in a single soil sample, an adequate pipeline including DNA isolation, primer selection, PCR amplification, library preparation, DNA sequencing, and bioinformatic post-processing is required. Besides DNA sequencing quality and depth, the selection of PCR primers and PCR amplification reactions arguably have the largest influence on the results. This study tested the performance and potential bias of two primer pairs, i.e., 515F (Parada)-806R (Apprill) and 515F (Parada)-926R (Quince) in the standard pipelines of 16S rRNA gene Illumina amplicon sequencing protocol developed by the Earth Microbiome Project (EMP), against shotgun metagenome-based 16S rRNA gene reads. The evaluation was conducted using five differently managed soils. We observed a higher richness of soil total prokaryotes by using reverse primer 806R compared to 926R, contradicting to in silico evaluation results. Both primer pairs revealed various degrees of taxon-specific bias compared to metagenome-derived 16S rRNA gene reads. Nonetheless, we found consistent patterns of microbial community variation associated with different land uses, irrespective of primers used. Total microbial communities, as well as ammonia oxidizing archaea (AOA), the predominant ammonia oxidizers in these soils, shifted along with increased soil pH due to agricultural management. In the unmanaged low pH plot abundance of AOA was dominated by the acid-tolerant NS-Gamma clade, whereas limed agricultural plots were dominated by neutral-alkaliphilic NS-Delta/NS-Alpha clades. This study stresses how primer selection influences community composition and highlights the importance of primer selection for comparative and integrative studies, and that conclusions must be drawn with caution if data from different sequencing pipelines are to be compared.

16S rRNA gene amplicon Illumina sequencing↗

A novel statistical methodology for quantifying the spatial arrangements of axons in peripheral nerves

A thorough understanding of the neuroanatomy of peripheral nerves is required for a better insight into their function and the development of neuromodulation tools and strategies. In biophysical modeling, it is commonly assumed that the complex spatial arrangement of myelinated and unmyelinated axons in peripheral nerves is random, however, in reality the axonal organization is inhomogeneous and anisotropic. Present quantitative neuroanatomy methods analyze peripheral nerves in terms of the number of axons and the morphometric characteristics of the axons, such as area and diameter. In this study, we employed spatial statistics and point process models to describe the spatial arrangement of axons and Sinkhorn distances to compute the similarities between these arrangements (in terms of first- and second-order statistics) in various vagus and pelvic nerve cross-sections. We utilized high-resolution transmission electron microscopy (TEM) images that have been segmented using a custom-built high-throughput deep learning system based on a highly modified U-Net architecture. Our findings show a novel and innovative approach to quantifying similarities between spatial point patterns using metrics derived from the solution to the optimal transport problem. We also present a generalizable pipeline for quantitative analysis of peripheral nerve architecture. Our data demonstrate differences between male- and female-originating samples and similarities between the pelvic and abdominal vagus nerves.

59 BASIC BIOLOGICAL SCIENCES↗

A Portable Miniature Cryogenic Environment for In Situ Neutron Diffraction

Neutron diffraction instruments offer a platform for materials science and engineering studies at extended temperature ranges far from ambient. As one of the widely used neutron sample environment types, cryogenic furnaces are usually bulky and complex, and they may need hours of beamtime overhead for installation, configuration, cooling, and sample change, etc. To reduce the overhead time and expedite experiments at the state-of-the-art high-flux neutron source, we developed a low-cost, miniature, and easy-to-use cryogenic environment (77–473 K) for in situ neutron diffraction. A travel-size mug serves for the environment where the samples sit inside. Immediate cooling and an isothermal dwell at 77 K are realized on the sample by direct contact with liquid N 2 in the mug. The designed Al inserts serve as the holder of samples and heating elements, alleviate the thermal gradient, and clear neutron pathways. Both a single-sample continuous measurement and multi-sample high-throughput measurements are demonstrated in this environment. High-quality and refinable in situ neutron diffraction patterns are acquired on model materials. The results quantify the orthorhombic-to-cubic phase transformation process in LiMn 2 O 4 and differentiate the anisotropic lattice thermal expansions and bond length evolutions between rhombohedral perovskite oxides with composition variation.

47 OTHER INSTRUMENTATION↗

Large-scale continuous carbon/glass fiber additive-compression molded composites

Additive Manufacturing (AM) or 3-D printing has advanced from small-scale desktop printers to large-scale printers. Most of the present large-scale printers utilize feedstock materials in the form of pellets to create composite structures. To create structurally robust composite parts, reinforcements in the form of short fibers (carbon or glass) are often used to impart mechanical properties to the printed parts. However, poor mechanical properties in Z-direction and high porosity of pellets-based printed composites compared to composite manufactured using traditional methods are serious concerns. The authors report a combined approach in the present work, where fiber reinforced composites are printed with a high-throughput continuous fiber deposition method followed by a secondary compression molding process. A specially designed end-effector mounted on a robotic arm is used to print composite preforms. Continuous comingled fibers (Thermofiber 12K CF-PA12, Thermofiber 12K S2-PA12, and Hybrid Thermofiber 12K CF-PA12+PEEK PA6) embedded in the thermoplastic nylon matrix are printed to create composite preform plaques. The printed preforms were further compression molded (CM) using a hydraulic hot-press to create highly consolidated composite parts. The mechanical properties of the continuous fiber composites produced by this combined approach are improved significantly due to the highly aligned continuous fibers and reduced porosity. Flexural strength, flexural modulus, and tensile modulus of AM-CM Thermofiber 12K CF-PA12 UD sample were 615.37 MPa, 75.65 GPa, and 122.23 GPa, respectively.

Kumar, Vipin↗