Search NASASearch

SEARCH · Search NASA

Results for “WATER CHEMISTRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

461 records · Page 6

The impact of chemistry on anion migration in bixbyite-structured lanthanide oxides

This manuscript describes atomistic calculations of oxygen vacancy and interstitial migration in bixbyite structured lanthanide oxides. We examine two types of compounds, one in which only one type of lanthanide cation is present and a second class in which two lanthanides are present in a 3:1 ratio as dictated by the symmetry of the bixbyite crystal structure. Using temperature accelerated dynamics and the nudged elastic band method, we quantify the role of chemistry on the energy barriers for the most important pathways for both vacancy and interstitial migration. We then analyze the impact of these variations on the overall diffusivity of each defect, quantifying the contribution of each pathway using the theory of kinosons. We find that vacancy mobility can vary by as much as three orders of magnitude through changes in chemistry at 500 K. Changes in interstitial mobility are more modest but can still vary by an order of magnitude. This points to the ability to tune the mass transport characteristics of these compounds through appropriate choices in chemistry. We have also included supplementary information containing the atomic structures of the relevant pathways.

36 MATERIALS SCIENCE

Dynamic Diketoenamine Crosslinking Unlocks Vinyl Polymer Vitrimers From β ‐Triketone Chemistry

Covalent adaptable networks (CANs) offer a compelling strategy to unite the mechanical robustness of thermosets with the reprocessability of thermoplastics, yet achieving simultaneous durability, processability, and true recyclability remains challenging. We introduce diketoenamine (DKE) vitrimers derived from β-triketone methacrylate monomers and demonstrate how rational monomer design dictates network processability, viscoelasticity, and recyclability. By systematically varying the spacer length between the β-triketone (TK) moiety and the polymer backbone, we identify a key structure–property relationship that dictates vitrimer behavior. Networks bearing TK pendants minimally displaced from the backbone suppress creep but exhibit limited stress relaxation, whereas extended spacers yield lower glass transition temperatures, higher effective crosslink densities, and efficient stress dissipation, enabling optical transparency and reprocessability. Extending this platform to ultra-high molecular-weight prepolymers introduces physical entanglements as secondary crosslinks, further enhancing dimensional stability without compromising processability. Both mechanical and chemical recycling validate the closed-loop circularity of these materials. Furthermore, these results establish TK methacrylates as a versatile platform for designing high-performance vitrimers that integrate durability, reprocessability, and true closed-loop recyclability.

closed-loop recyclability

Surface analysis insight note: Illustrating the effect of adventitious contamination on Pt photoemission peak intensities

Adventitious carbon contaminations are not only omnipresent and used for charge referencing of XPS spectra but also can alter the apparent presence of the element peaks that span over the large spectral window of binding energies. This Insight note describes the effect of an adventitious contamination layer on Pt and presents, in brief, the approach whereby the component spectra are derived for ion beam cleaned Pt samples that can then utilize linear mathematics to peak fit said spectra thus quantifying the amount of each component including that assigned to the contamination itself of Pt metal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)